At least 37 records · Page 2

Utah FORGE: Wells 16A(78)-32 and 16B(78)-32 Extended Circulation Test Data - August and September 2024

The dataset includes data collected during an extended circulation test conducted at the Utah FORGE site between August 8 and September 5, 2024. It provides uncorrected, raw digital data from the test, along with calibration information and a final report detailing the test procedures and corrections. The data is bundled in a single .zip file containing both field calibration and test data. Files include manual calibration data for temperature, pressure, and flow meters, as well as uncorrected, time-stamped measurements recorded in 30-second intervals, such as wellhead pressures, flow rates, and temperatures for wells 16A(78)-32 and 16B(78)-32. Additionally, the final report offers insights into the test methodology and provides guidelines on how to apply field calibrations to correct the raw Pason data.

15 GEOTHERMAL ENERGY↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Radiolysis Data for Hydrogen Gas Generation During Gamma Irradiation of Pre-Corroded and Pristine Aluminum Samples - An Aluminum SNF Dry Storage Study Interim Report

Information and data from radiolysis testing to measure hydrogen (H₂) generated from hydrated oxides on aluminum exposed to ⁶⁰Co radiation were reviewed to evaluate hydrogen generation with radiation dose. Hydrogen generation rate is a primary input to the coupled thermal-chemical system model of the performance of aluminum-clad spent nuclear fuel in a dry storage canister (ASNF-in-canister) over its storage life. Hydrogen generation data and hydrogen generation rate (hydrogen generated per absorbed radiation dose, $\Delta$(H₂)/$\Delta$(dose)) were reported in two reports for radiolysis testing [1, 2]. The testing involved first-time data¹ for radiolytic yield of hydrogen from hydrated-oxides-on-aluminum substrates, and from pristine (non-corroded) aluminum substrates. The laboratory-grown hydrated-oxides-on-aluminum substrates contained a ~ 5 μm film consisting of the trihydroxide bayerite (Al(OH)₃) with amounts of the oxyhydroxide boehmite (AlOOH). These specimens were assumed to also contain physisorbed water (unquantified). The pristine substrates were flat coupons of aluminum that were ground to a 600-grit finish but were not immersed in water to grow a hydrated oxide. The pristine substrates were tested as companion specimens to provide information on hydrogen generation from material without chemisorbed water and were assumed to contain physisorbed water (unquantified).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Summary of Savannah River Site FY23 Salt Waste Qualification Data

The Savannah River National Laboratory (SRNL) analyzed samples from Savannah River Site (SRS) Waste Tanks 41H and 21H to support qualification of Salt Waste Processing Facility (SWPF) Waste Batches 8 and 9 for processing (the FY23 Salt Batch Qualification samples). These Tanks (i.e. 41H and 21H) are blend tanks for feed to SWPF. None of the samples displayed any unusual or unexpected characteristics such as large amounts of solids, floating solids, or unusual color. Characterization of these samples confirmed similar chemical composition and characteristics to previous salt waste batches. The results for Batches 8 and 9 were provided by SRNL to Savannah River Mission Completion (SRMC), the Liquid Waste Operations subcontractor at SRS, as External Sample Results (Laboratory Information Management System (LIMS)) Reports. Additionally, a separate technical memo was issued by SRNL to report re-test data for Batch 8 for Cs-137 for filtered samples only which were run at the request of SWPF. For Batch 9, a set of samples was also analyzed in parallel by the SWPF-Analytical Laboratory (SWPF-AL). The SWPF-AL data is included herein for comparison with the SRNL data where applicable. The analytical results (both rapid, typically 4 weeks, and long term, typically 8 weeks) for Batches 8 and 9 are now summarized and discussed in this technical report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CalWave - TEAMER UMaine 2021 Tank Testing

This is the data submission to the teamer report for RFTS1 during which tank testing at UMaine W2 tank occurred. This submission includes the relevant information and recorded data of CalWave's UMaine wave tank testing conducted under TEAMER Request for Support Round 1. During the testing CalWave assessed an autonomous control approach for changing PTO gain parameters based on "on board" sea state detection. The data submitted includes an overview of normalized PTO gains based on sea state values and for a set of 8 relevant sea states the WEC motion. All data was collected on CalWave's SCADA system and UMaine's motion tracking system. The data submitted suffices the creation of figures as shown in the PDF report submitted alongside the data and the submission includes excel sheets (parameter gains), MATLAB structures (absorber motion), and the mentioned PDF report.

16 TIDAL AND WAVE POWER↗

Quantitative Prediction of Perovskite Stability Using Accelerated Testing and Machine Learning

PV technologies based on hybrid perovskites offer the potential for reducing solar cell costs, but they are particularly vulnerable to degradation by environmental factors such as moisture, oxygen, and illumination. Commercialization will require not only stable materials and device architectures but also accelerated testing protocols and models that can predict degradation from the accelerated testing data. Here, we report results from in situ photoluminescence (PL) and photoconductivity (PC) measurements during perovskite degradation with simultaneous optical transmittance (Tr) measurements or reflected dark field (DF) imaging. From PL, PC, Tr, and DF, we determine (respectively) the steady-state quasi-Fermi level splitting, the mean effective carrier diffusion length, the extent of conversion of perovskite to higher bandgap degradation products, and the extent of scattering from domains with different orientation or composition, all as a function of time during degradation. Simultaneous measurement of PL-PC-Tr or PL-PC-DF on perovskite absorbers in an environmental chamber over a wide range of humidity, oxygen, temperature, and illumination levels yields a rich data set. We use machine learning to develop a model that accurately predicts (within 10%) the time for the diffusion length to decrease to 85% of its initial value. The model takes the environmental conditions and the first few measurements from the PL-PC-Tr or PL-PC-DF experiment as input. Thus, the model provides a framework to interpret the results of accelerated testing of absorber materials. One of the dominant features in the model of degradation for CH 3 NH 3 PbI 3 is the initial rate at which transmittance increase. For devices with opaque contacts, the pixel-averaged rate of change of the intensity in dark-field images can be used in place of transmittance. Results are also presented on full PV devices with in-situ current-voltage (JV) measurements. Here, the data from simultaneous PL-DF-JV under environmental stresses reveal intimate connection between degradation and shunts and provide a framework to extend accelerated testing to devices. Further, the presentation reveals underlying universal behavior in degradation pathways over a broad range of environmental stresses and perovskite compositions.

14 SOLAR ENERGY↗

Degradation and Modeling of Large-Format Commercial Lithium-Ion Cells as a Function of Chemistry, Design, and Aging Conditions

Demand for large-format (>10 Ah) lithium-ion batteries has increased substantially in recent years, due to the growth of both electric vehicle and stationary energy storage markets. The economics of these applications is sensitive to the lifetime of the batteries, and end-of-life can either be due to energy or power limitations. Despite this, there is little information from cell manufacturers on the sensitivity of cell degradation to environmental conditions or battery use. This work reports accelerated aging test data from four commercial large-format lithium-ion batteries from three manufacturers, with varying design (thickness, casings, ...), chemistry (lithium-iron-phosphate (LFP) or lithium-nickel-manganese-cobalt-oxide positive electrodes (NMC), with graphite (Gr) negative electrodes), and capacity (50 to 250 Amp hours). The tested LFP|Gr cell is found to be relatively insensitive to cycling conditions like temperature or voltage window, while NMC|Gr cells have varying sensitivity. Degradation trends are further investigated by training predictive models: simple polynomial trend lines, a semi-empirical reduced-order model, and an empirical reduced-order model identified using machine-learning based on symbolic regression. Calendar and cycle life are simulated over a variety of conditions to directly compare the various batteries. Cell size and thickness are found to substantially impact sensitivity to temperature during cycle aging, while electrode chemistry impacts depth-of-discharge sensitivity. Real-world battery lifetime is evaluated by simulating residential energy storage and commercial frequency containment reserve systems in several U.S. climate regions. Predicted lifetime across cell types varies from 7 years to 20+ years, though all cells are predicted to have at least 10 year life in certain conditions.

battery lifetime↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attenuator, PC-2.92mm, Fixed (Proficiency Test Report: Document # 6679664_11752120)

The PSL has reviewed the documentation and data provided by NNSS–Livermore Operations with respect to this proficiency test. This proficiency test was performed to assess NNSS–Livermore Operations’ ability to perform scattering parameter calibrations. The level of documentation was satisfactory. On 5/19/2020, NNSS–Livermore Operations reported the data for the proficiency test conducted on the attenuator. NNSS–Livermore Operations performed this proficiency test using an Anritsu vector network analyzer, an electronic calibration module, and verification kit. The PSL used a Keysight vector network analyzer and mechanical calibration kit. The PSL results included in this proficiency test report were taken on June 23, 2020.

47 OTHER INSTRUMENTATION↗

Utah FORGE: Well 16A(78)-32/Well16B(78)-32 Circulation Test Data

This dataset encompasses the collected data and associated reports from the low-rate injection circulation test conducted on wells 16A(78)-32 and 16B(78)-32 in July 2023 at Utah FORGE. It includes comprehensive raw circulation data, captured by Pason and Schlumberger (SLB). The dataset details various parameters recorded during circulation testing such as produced fluid, injection pressure, injection rate, produced rate, temperature, downhole pressure difference, bottom hole pressure in the well, and surface treating pressure. Note that the Pason data is presented in Mountain Time, whereas the SLB data is in Pacific Time.

15 GEOTHERMAL ENERGY↗

Attenuator, PC-2.92mm, Fixed (Proficiency Test Report; PT ID Number 6679665)

The PSL has reviewed the documentation and data provided by NNSS–Livermore Operations with respect to this proficiency test. This proficiency test was performed to assess NNSS–Livermore Operations’ ability to perform scattering parameter calibrations. The level of documentation was satisfactory. On 12/28/2021, NNSS–Livermore Operations reported the data for the proficiency test conducted on the attenuator. NNSS–Livermore Operations performed this proficiency test using an Anritsu vector network analyzer, an electronic calibration module, and verification kit. The PSL used a Keysight vector network analyzer and mechanical calibration kit. The PSL results included in this proficiency test report were taken on June 23, 2020.

42 ENGINEERING↗

Sister Rod Destructive Examinations (FY23)

As a part of DOE NE High Burnup Spent Fuel Data Project, Oak Ridge National Laboratory (ORNL) is performing destructive examinations (DEs) of high burnup (HBU) (>45 GWd/MTU) spent nuclear fuel (SNF) rods from the North Anna Nuclear Power Station operated by Dominion Energy. The SNF rods, called sister rods or sibling rods, are all HBU and include four different kinds of fuel rod cladding: standard Zircaloy-4 (Zirc-4), low-tin (LT) Zirc-4, ZIRLO, and M5. The DEs are being conducted to obtain a baseline of the HBU rod’s condition before dry storage and are focused on understanding overall SNF rod strength and durability. Composite fuel and defueled cladding will be tested to derive material properties. Although the data generated can be used for multiple purposes, one primary goal for obtaining the post-irradiation examination data and the associated measured mechanical properties is to support SNF dry storage licensing and relicensing activities by (1) addressing identified knowledge gaps and (2) enhancing the technical basis for post-storage transportation, handling, and subsequent disposition. This report provides a cumulative status report of the testing progress, data accumulated, and conclusions reached as a part of the program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interim Creep, Fatigue and Creep-Fatigue Data from FY 2022 INL Testing of A709 with Precipitation Treatment for ASME Code Case Data Package

This report provides the status of creep, fatigue, and creep-fatigue testing that transpired in fiscal year 2022 at Idaho National Laboratory (INL). This testing is being conducted to develop the data package to qualify A709 in Section III, Division 5 of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC). This would permit the use of A709 for elevated temperature nuclear construction. Preliminary results continue to demonstrate the improved creep and fatigue resistance of A709 compared to 316H stainless steel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automated qualification data tool for high temperature metallic materials

This report describes a framework for storing, processing, and displaying qualification data for high temperature mechanical properties. The framework automates the process of generating design data from mechanical test results, for example for a data qualification report for the ASME Boiler \& Pressure Vessel Code. The framework has three parts: a data storage model with common formats for several types of typical mechanical property tests, a backend based on the \pycreep Python library for correlating and extrapolating the data to generate design material properties and allowable stresses, and a demonstration user interface for displaying, sorting, and filtering the data and exploring different options for modeling the design mechanical properties. The report discusses the options available for data processing, with illustrations from real test data on Alloy 617, Alloy 709, Alloy 740H, and Laser-Powder Bed Fusion 316H. The framework is complete for ASME type data analysis and will be used to store test data generated by the Department of Energy, Office of Nuclear Energy, Advanced Materials and Manufacturing Technologies sponsored qualification programs. Future work could extend the tool to other types of material properties and/or expand the demo user interface to make it accessible across the AMMT program.

36 MATERIALS SCIENCE↗

Small-Scale Drying: FY2020 Interim Report

This report documents the interim experimental status of small-scale drying tests currently being performed at Pacific Northwest National Laboratory. These small-scale drying tests are to develop the technical bases for sensors, techniques, and approaches that will be used to address the challenges faced when determining moisture content from gas samples taken at the North Anna Nuclear Generating Station for the High Burnup Demonstration Project. Specifically, the purpose of these tests is to support Sandia National Laboratories gas sample methods and analyses through a series of small-scale experiments. Key focus areas include performing tests to: • Correlate sample bottle measurements to in-cask conditions • Estimate the amount of trapped and absorbed water on cask features and surfaces that can contribute to water vapor • Assess the accuracy of the hygrometer used in the measurements under similar conditions • Identify additional methods for measuring humidity in casks easily and accurately using lessons-learned from Sandia National Laboratories, including direct gravimetric and isotopic tracer techniques. To address these topics this report outlines a series of five tests and any data collected to date that were planned for FY 2020 that include 1) humidity measurement method development, 2) gas bottle sampling tests, 3) surface drying tests on cladding, 4) small-scale drying of cladding, and 5) small-scale drying of guide-tube/dashpots. This interim report documents the experimental background, design and progress of these small-scale drying tests. Further data gathered will be summarized in the FY 2021 report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗