Search for the Exclusive W Boson Hadronic Decays W ± → π ± γ, W ± → K ± γ and W ± → ρ ± γ with the ATLAS Detector

A search for the exclusive hadronic decays W ± → π ± γ, W ± → K ± γ, and W ± → ρ ± γ is performed using up to 140 fb -1 of proton-proton collisions recorded with the ATLAS detector at a center-of-mass energy of $\sqrt{s} =$ 13 TeV. If observed, these rare processes would provide a unique test bench for the quantum chromodynamics factorization formalism used to calculate cross sections at colliders. Additionally, at future colliders, these decays could offer a new way to measure the W boson mass through fully reconstructed decay products. The search results in the most stringent upper limits to date on the branching fractions B(W ± → π ± γ) < 1.9 × 10 -6 , B(W ± → K ± γ) < 1.7 × 10 -6 , B(W ± → ρ ± γ) < 5.2 × 10 -6 at 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lessons Learned: Summary of Insights From the HERO WEC and Waves to Water Deployments Between 2022 and 2024

In 2020, a team from the National Renewable Energy Laboratory (NREL) partnered with the East Carolina University Coastal Studies Institute to develop a small, modular, wave-powered point absorber desalination prototype. That prototype, known as the hydraulic and electric reverse osmosis wave energy converter (HERO WEC), was intended to de-risk the installation activities planned for the Waves to Water Prize sponsored by the Water Power Technologies Office. The NREL team was given approximately 18 months to design, build, bench test, and deploy the HERO WEC prototype. Since the initial HERO WEC development, it has been used for two in-lab test programs and three ocean deployments. The first in-lab test program focused on ensuring that the overall operation of the device occurred as expected and on validating the operation of safety systems such as pressure relief valves or electrical breakers for load mitigation. The second in-lab test program was the first time the NREL team leveraged NREL’s large-amplitude motion platform to characterize the performance of the HERO WEC. Of the three in-water deployments, the first deployment was effectively an installation and recovery practice with no meaningful wave activity during the time that it was installed. The second deployment was a 2-week effort that enabled both the electric and hydraulic configurations of the device to be in the water for approximately 5 days each. This deployment was also the first time that the team had the opportunity to perform a drivetrain swap on the Coastal Studies Institute research vessel. The third deployment had to be split into two separate installations due to minor damage incurred from the WEC spinning during the initial installation. This report summarizes the deployments, the challenges encountered with each deployment, and the lessons learned for future work.

16 TIDAL AND WAVE POWER↗

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

A Dedicated Muon EDM Experiment in the `g-2 Storage Ring

Spin precession experiments offer exciting motivations to search for new physics. We propose here an idea of using a modified version of the Muon g-2 storage ring for a potential new scientific program to search for a non-zero muon electric dipole moment (EDM). Using both electric and magnetic dipole fields to produce a "frozen spin" condition for the MDM (all the while enhancing the EDM spin precession), the storage ring would operate at a lower central muon momentum than for the present Muon g-2 measurement. The incident proton beam on target for the muon production can be obtained from the PIP-II high intensity proton beam. Preliminary calculations and simulation results of muon production at 800 MeV PoT, along with the determination of the closed orbit inside the hybrid 'g-2' storage ring configuration, shall be presented. Possibilities of using the 'g-2' storage ring as a test bench to demonstrate the freezing of the MDM spin precession shall be discussed. The operational range of the muon's momentum and energy, and their respective window of electric and magnetic field values to establish the frozen spin condition, shall be presented. We shall also briefly discuss the physics prospects and improvements in muon EDM bounds upon using Fermilab's PIP-II beam.

Narayanan, Aakaash [Fermilab] (ORCID:0000000157944↗

A Dedicated Muon EDM Experiment in the `g-2 Storage Ring

Spin precession experiments offer exciting motivations to search for new physics. We propose here an idea of using a modified version of the Muon g-2 storage ring for a potential new scientific program to search for a non-zero muon electric dipole moment (EDM). Using both electric and magnetic dipole fields to produce a "frozen spin" condition for the MDM (all the while enhancing the EDM spin precession), the storage ring would operate at a lower central muon momentum than for the present Muon g-2 measurement. The incident proton beam on target for the muon production can be obtained from the PIP-II high intensity proton beam. Preliminary calculations and simulation results of muon production at 800 MeV PoT, along with the determination of the closed orbit inside the hybrid 'g-2' storage ring configuration, shall be presented. Possibilities of using the 'g-2' storage ring as a test bench to demonstrate the freezing of the MDM spin precession shall be discussed. The operational range of the muon's momentum and energy, and their respective window of electric and magnetic field values to establish the frozen spin condition, shall be presented. We shall also briefly discuss the physics prospects and improvements in muon EDM bounds upon using Fermilab's PIP-II beam.

Narayanan, Aakaash [Fermilab] (ORCID:0000000157944↗

Modeling of H2 Dispersion at ARIES

Hydrogen is a versatile and clean energy carrier that can be produced from various renewable sources such as wind, solar, and hydropower and help decarbonize electricity grids, industry, and transportation. Using the Hydrogen Research Facility under Advanced Research on Integrated Energy Systems (ARIES) at the National Renewable Energy Laboratory's (NREL) Flatirons campus as a test bench, the study examines the feasibility, useability, and value of using computational fluid dynamics (CFD) techniques to model hydrogen dispersion. The ARIES facility was chosen because controlled hydrogen releases can be performed at a rate of 27 kg-H2/hr. Site-specific atmospheric and weather condition data such as wind speed and temperature were used as inputs to the model. The results show statistical distributions and ranges of hydrogen concentrations at locations throughout the domain. Wind conditions are found to significantly impact the release behavior, including the hydrogen cloud's direction and concentrations. At low wind speeds (below 1 mph), hydrogen forms a cloud and at higher wind speeds (> 2-4 mph) hydrogen plume stretches in the direction of wind momentum. From >100 simulations for ARIES site-specific conditions, statistical quantities combined with a clustering algorithm were used to propose sensor location at various elevations from ground.

dispersion↗

Novel Design and Fabrication of a High Frequency Transient Heat Flux Sensor for Use in an RDE

Rotating detonation engine (RDE) combustion systems have been a topic of interest in the pressure gain combustion community for their benefits over traditional gas turbine engine combustors. However, cooling requirements for these engines are significantly higher and less predictable than non-detonating engines. To understand the high-speed heat transfer dynamics inside an RDE, a novel, high-frequency heat flux gage is presented. This study aims to design a robust, single-sided sensor that can withstand the high temperature and harsh environment of an RDE for extended durations. Sensor bench testing is performed using a hot plate as a heat source, and the sensor response is compared to a finite-element analysis (FEA) model. The sensor response is then tested inside a water-cooled RDE and the wall heat flux is compared to calorimetry data.

rotating detonation engines↗

Theory, analysis, and testing of an angular resonator for wave energy generation

This article describes the theory, analysis, and initial bench-top testing of a minimally invasive, rotational resonator designed to produce small amounts of electrical energy for use in oceanic observation buoys. Here, this work details the systems of equations that govern such a resonator, its potential power production, and its predicted effects on the modified motion of the buoy. Finally, a bench-top test apparatus is designed and experimented upon to identify the system and verify the system of equations empirically.

16 TIDAL AND WAVE POWER↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 1. Characterizing Thermal–Hydrological–Mechanical Processes

Abstract Bentonite clay is widely used in engineered barrier systems for the permanent disposal of high‐level radioactive waste due to its low permeability, high swelling capacity, and thermal stability. However, the complex thermal‐hydrological‐mechanical (THM) processes induced by heating from decaying radioactive waste and hydration from surrounding rock can lead to heterogeneous changes that are difficult to measure and predict. This study develops an Electrical Resistivity Tomography (ERT)‐based framework for monitoring THM processes, progressing from sample‐scale to bench‐scale tests, to inform field‐scale applications. Sample‐scale tests analyzed small bentonite samples under controlled variations in water content, temperature, and porosity to establish fundamental resistivity relationships. Bench‐scale tests involved larger bentonite columns subjected to heating (up to 200°C) and hydration under controlled pressure, simulating repository conditions. ERT measurements, complemented by X‐ray CT imaging, temperature monitoring, and tracing sensors, revealed coupled THM processes, such as hydration‐induced compression, swelling, and thermal gradients, leading to complex resistivity patterns. The results demonstrate the potential of ERT for capturing THM‐induced resistivity changes, though challenges remain in upscaling and quantitative analysis. This study evaluates laboratory test capabilities and proposes future improvements for understanding THM‐induced resistivity responses. A conceptual framework for ERT implementation in field‐scale monitoring is presented, synthesizing findings from both scales and exploring how ERT data can inform long‐term modeling and reduce prediction uncertainties. Overall, this ERT‐based framework offers a robust method for monitoring bentonite buffers, aiding in early issue detection and supporting the safe long‐term disposal of radioactive waste in geological repositories, while highlighting the need for future development. Plain Language Summary Bentonite clay is crucial in engineered barrier systems (EBS) for containing high‐level radioactive waste due to its ability to absorb water, swell, seal and remain stable under high temperatures. When bentonite absorbs water and heats up from radioactive decay, it experiences complex changes in its physical and mechanical properties. Understanding these changes is important for ensuring the long‐term safety and effectiveness of EBS. This study used Electrical Resistivity Tomography (ERT), a non‐invasive method that measures electrical conductivity to monitor these changes during laboratory experiments. The ERT data revealed significant variations in resistivity corresponding to changes in water content, temperature, and density, providing detailed spatial and temporal insights into the behavior of bentonite. These findings enhance our ability to predict the long‐term performance of bentonite barriers, ensuring the safe containment of radioactive waste. By improving our understanding of bentonite's behavior, this research supports the development of more reliable and effective barrier systems for radioactive waste disposal, protecting the environment and public health. Key Points ERT monitoring was employed to capture resistivity changes in bentonite during controlled heating and hydration experiments, providing insights into THM processes ERT data reveal significant resistivity changes correlated with water content, temperature, and mechanical effects, enhancing the understanding of THM dynamics in bentonite This study explores the potential of the framework for application in field‐scale EBS monitoring, emphasizing the need for integrating additional geophysical methods for comprehensive subsurface imaging

Chen, Hang↗

Location-Specific Microstructure Characterization Within AM Bench 2022 Nickel Alloy 718 3D Builds

Abstract The Additive Manufacturing Benchmark Test Series (AM Bench) is a broad effort to produce rigorous measurement datasets for validating AM computer simulations across the range of processing, structure, and properties, for many additive manufacturing (AM) build methods and material classes. Here, the microstructures of nickel alloy 718 AM Bench 2022 test artifacts produced using laser-based powder bed fusion (PBF-LB), in both as-built and fully heat-treated conditions, are examined. Cross sections are primarily characterized using large area scanning electron microscopy (SEM) electron backscatter diffraction (EBSD) and example analyses of the crystallographic textures are described. These data are part of a large set of in situ and ex situ measurements from both three-dimensional builds and laser tracks on bare plates. All the measurement data are available online with download links at www.nist.gov/ambench .

Levine, L. E. (ORCID:0000000334484229)↗

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of Anoxic Iron Corrosion on WIPP Brine Geochemistry FY23 Final Report (U)

A 280-day study was completed to evaluate the effect of zero-valent iron (Fe 0 ) on the Waste Isolation Pilot Plant (WIPP) brine geochemistry under anticipated reducing conditions. Hydrogen (H 2 ) gas is expected to be present in the repository after closure due to the anoxic corrosion of a vast quantity of iron contained in the waste forms disposed at WIPP; therefore, a background argon atmosphere containing H 2 was chosen for this study. WIPP groundwater brine pH and E h will impact the mobility and fate of plutonium within the repository. Modeling and laboratory results for Castile WIPP brine indicate that equilibrium fa values relative to the standard hydrogen electrode (SHE) are 40 mV more reducing (i.e., more negative) than those for Salado WIPP brine (-480 mV vs. -440 mV, respectively) because of the higher pH of the Castile brine (pH 9 .3 for Castile vs. pH 8.8 for Salado). The E h and pH data were corrected for the effects of high ionic strength. The experimental results for both brines are consistent with thermodynamic predictions using OLI Systems' Mixed Solvent Electrolyte chemical equilibrium model. The measured and corrected pH and E h data from this study are provided in Table ES-I and Table ES-2, respectively. The experimental study, with four test conditions in triplicate, was performed in a dual glovebox with a nominally 3 vol.% H 2 in argon atmosphere (target H 2 range: 3 ± I vol.%). Simulants containing MgO only ( experimental control) and MgO+Fe 0 (WIPP base case) were prepared for both the Salado and Castile brines. MgO was included in all simulants to account for the use of bulk magnesium oxide in the WIPP repository. Fe 0 was included in some simulants to incorporate the effects of the anoxic corrosion of iron and in-situ hydrogen generation in the study. The brine compositions were developed by Sandia National Laboratory (SNL; Xiong, 2008) and have been used in previous WIPP evaluations. The test method (agitation, etc.) is partially based on ASTM D3987-12. Twelve rounds of periodic measurements of pH and E h were performed over the course of the study. Chemical analysis results for liquids and solids (ICP-MS, ICP-ES, IC Anion, TIC, SEM-EDX) are consistent with the pH, E h , and thermodynamic modeling results. This study included the following conditions that deviate from anticipated post-closure conditions following brine intrusion, but were selected to facilitate bench-scale testing to validate modeling of pH and E h for the post-closure WIP P repository: an anoxic glove box atmosphere containing ≤ 4 vol. % H 2 vs. substantially higher H 2 gas concentrations assumed in the WIPP Performance Assessment (PA); a significantly higher liquid-to-solid test ratio compared to the much lower phase ratio anticipated in the WIP P repository; agitation of the simulant bottles to maximize mass transfer; and finally the use of Fe 0 reagents having a much greater surface area than expected in the WIP P repository. Non-representative conditions were chosen for various reasons such as: to provide bounding conservative results, to provide a margin of safety for testing, or to facilitate simulant sub-sampling and analysis. In a parallel effort, aqueous electrolyte thermodynamic models were developed for the synthetic Salado and Castile brines to inform the experimental design, facilitate laboratory data interpretation, and allow extension of evaluations beyond the parameters tested. Thermodynamic modeling simulations including the MgO and Fe 0 additives that are directly relevant to the experimental measurements (e.g., pH calibration curve, ORP corrections) are included in this report. The measured fa of the simulants was close to the OLI model predictions for both brines and was largely controlled by the background H 2 partial pressure in the vapor phase as well as H 2 generated in situ in the aqueous phase by the Fe 0 corrosion. The H 2 gas-phase concentration tested and thermodynamically evaluated was much lower than is assumed in the WIPP PA; however, H 2 (g) concentrations significantly below this level are still predicted to result in very reducing conditions. In conclusion: • The experimental results are consistent with thermodynamic model predictions for fa, pH, and the effects of high ionic strength. • Evidence to date suggests that the H2 concentration in the glovebox atmosphere ultimately determined the final E h values of the simulants and resulted in highly reducing conditions. As a result, little difference was observed between the control simulants containing only MgO and the WIPP base-case simulants that contained MgO and Fe 0 . • This test methodology is recommended for future studies evaluating WIPP repository conditions. The methodology includes: (1) background H 2 in argon with agitation ( or could alternatively include in-situ-generated H 2 in sealed bottles); (2) carefully measured and corrected ORP data ( with much effort focused on allowing the probes to fully stabilize); and (3) ionic-strength-corrected pH data. Other best practices, such as simulant sparging/handling, ORP probe replacement, etc., should also be considered. • The coupling of experimental studies and thermodynamic modeling is also highly recommended because these methods inform and direct one another leading to greater confidence in and understanding of the results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rejection of low-molecular weight neutral organics is highly sensitive to reverse osmosis system design and operation

A computational model was developed to investigate the significance of system design and operating conditions on the rejection of neutral, low-MW organics by reverse osmosis for potable reuse. Here, the model demonstrated that the decrease in local rejection as net driving pressure decreases is substantially greater for moderately rejected compounds than for highly rejected compounds. At recovery values less than 70%, the local permeate concentration can exceed the pressure vessel feed concentration for moderately rejected compounds. System-level rejection of moderately rejected compounds is likewise substantially more sensitive to operating conditions than highly rejected compounds. The findings highlight a drawback of relying on rejection results from bench-scale testing that operates at low recovery, which invariably has higher rejection than full-scale systems operating at similar pressure. The analysis demonstrates a trade-off in which the low-pressure, high-recovery operation desired for potable reuse systems can be detrimental to the removal of low-MW neutral organics. The removal of low-MW neutral organics can be improved if organics rejection is explicitly evaluated during the design process.

42 ENGINEERING↗

Performance and economic viability assessment of a novel CO 2 adsorbent for manufacturing and integration with coal power plants

Here, this study assesses the performance and economic feasibility of a novel CO 2 adsorbent for post-combustion capture in DOE/NETL’s 650 MWnet SubC PC power plant (case B11B). Bench-scale tests showed an initial adsorption capacity of 16.3 wt%, which decreased to 12.1 wt% after 41 adsorption–desorption cycles due to induced particle aggregation by over-humidification. With a conservative adsorption capacity of 8.8 wt% and 695 adsorption–desorption cycles, an adsorbent replenishment rate of 10 tonnes/h is necessary to capture 90% of CO 2 . The breakeven sale price of the adsorbent produced at this rate is $\$$1,293/tonne, which is 40 to 80 times lower than prices for K 2 CO 3 adsorbents reported in the literature (e.g., K 2 CO 3 /TiO 2 , K 2 CO 3 /ZrO 2 ) while providing better capture performances. Sensitivity analysis reveals that increasing the plant production rate from 10 to 40 tonnes/h reduces the sale price by 8%. The study also compares the CO 2 capture cost to Cansolv, an integrated solvent-based technology. The novel adsorbent requires 2.4 GJ/tonne of CO 2 for regeneration, lower than Cansolv’s 2.7 GJ/tonne. With conservative performance estimates, the capture cost is $\$$54/tonne of CO 2 , slightly higher than Cansolv’s $\$$45/tonne. To achieve lower or comparable capture costs to Cansolv, the adsorbent should meet one of the following conditions at a commercial scale: minimum 950 cycles, 16 wt% capture capacity, 50% of the adsorbent recovery, or a reduced cost to $\$$646/tonne by upscaling the manufactury to 75 tonnes/h.

01 COAL, LIGNITE, AND PEAT↗

Node-red Software Architecture For Soec System Control

The software workflows that have been developed are open-source and therefore can be accessed and utilized by researchers and students all around the world for free of cost. The software is flexible and easily modifiable to suit the needs for testing bench-scale to system-level setups, and is not limited to just hydrogen generation facilities. The web-interface of the code allows for easy remote access and management, which is especially useful for distributed systems. This is more challenging with traditional PLCs, which often require direct connections or specialized software, making remote troubleshooting more cumbersome. Additionally, since the underlying interface is open-source, with an active community contributing to its development, regular updates, new features, and a wealth of community support and shared solutions will keep improving the overall architecture without excessive fees for upgrades.

Shigrekar, Amey [Idaho National Laboratory (INL), ↗

Compact Absorber Technology Leads to Significant Reduction in the Cost of Point Source CO 2 Capture

The size of columns in traditional absorption-based processes for CO 2 capture contributes significantly to the overall capital cost. A demonstrated method to reduce the cost of point source CO 2 capture, focusing on reducing the absorber height by increasing the liquid-to-gas reaction contact area and decreasing the CO 2 diffusion resistance without increasing gas-side pressure drop is presented along with techno-economic analysis results. Bench-scale tests on the unique Compact Absorber showed overall CO 2 mass transfer enhancement of varying degrees compared to a traditional packed column for similar process conditions, demonstrating that a 60+% reduction in size of a typical post-combustion absorber with a packing height of 70-100 ft and total height of 150-180 ft can be achieved. The techno-economic analysis showed significant cost reductions when the Compact Absorber is combined with other transformative aspects of the University of Kentucky Institute for Decarbonization and Energy Advancement point source CO 2 capture process compared to the U.S. Department of Energy National Energy Technology Laboratory pertinent reference case for pulverized coal plants with CO 2 capture. Here, a levelized cost of electricity excluding CO 2 transportation and storage of $\$95.6$/MWh was estimated, which is a 9% reduction, with a total capital cost contribution of $45/MWh, which is a 12% reduction. Additionally, a breakeven CO 2 sales price also referred to as the cost of CO 2 capture, of $36.70/tonne was estimated when the UK hindered primary amine solvent is used, which is a 20% reduction compared to the reference case.

CO2 capture↗

Reducing Methane Emissions with an Engine Fuel Reformer

Southwest Research Institute (SwRI) designed and demonstrated a compact, plasma-based fuel reformer designed to reduce methane leaks from natural-gas engines used in pipeline compression and industrial power applications. The system uses pulsed electrical discharges to convert a small portion of methane (CH4) into hydrogen (H2) and light hydrocarbons, promoting more complete combustion and reducing unburned methane in the exhaust. The reformer was evaluated through bench-scale testing, high-flow facility testing, and engine-integration testing on representative low-speed and high-speed natural-gas engines. Measured methane-leak reductions ranged from 1 to 27 percent, depending on engine type and operating condition, while reformer energy consumption remained below one percent of total engine output. Design refinements addressed thermal and electrical challenges, resulting in reliable operation with minimal impact on engine control systems. The project achieved all performance objectives within budget and schedule, produced a patentable pulsed-power system design, and established a scalable, energy-efficient pathway for mitigating methane leaks from existing natural-gas engine infrastructure.

03 NATURAL GAS↗

Advancing a Low-Temperature, Low-Cost Direct Air Capture System Based on Organic Chemistry

Holocene Climate Corporation (Holocene) partnered with Oak Ridge National Laboratory (ORNL) to conduct bench-scale testing of a new optimized Direct Air Capture (DAC) process to assist the U.S. Department of Energy (DOE) in achieving the Carbon Negative Shot target of under $\$$100/net tonne CO₂ removed by 2031. Holocene’s DAC process for carbon dioxide (CO₂) removal uses amino acids and guanidine compounds, an ORNL-invented chemical process and licensed by Holocene. Holocene will use this novel chemistry to develop a new process and deploy the technology commercially.

36 MATERIALS SCIENCE↗