Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature boosting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Magnetic dilution effect and topological phase transitions in (Mn 1- x Pb x )Bi 2 Te 4

We report, as the first intrinsic antiferromagnetic topological insulator, MnBi 2 Te 4 has provided a material platform to realize various emergent phenomena arising from the interplay of magnetism and band topology. Here, by investigating (Mn 1-x Pb x )Bi 2 Te 4 (0 ≤ x ≤ 0.82) single crystals via the x-ray, electrical transport, magnetometry and neutron measurements, chemical analysis, external pressure, and first-principles calculations, we reveal the magnetic dilution effect on the magnetism and band topology in MnBi 2 Te 4 . With increasing x, both lattice parameters a and c expand linearly by around 2%. All samples undergo the paramagnetic to A-type antiferromagnetic transition with the Néel temperature decreasing lineally from 24 K at x = 0 to 2 K at x = 0.82. Our neutron data refinement of the x = 0.37 sample indicates that the ordered moment is 4.3(1)μ B /Mn at 4.85 K and the amount of the Mn Bi antisites is negligible within the error bars. Isothermal magnetization data reveal a slight decrease of the interlayer plane-plane antiferromagnetic exchange interaction and a monotonic decrease of the magnetic anisotropy due to diluting magnetic ions and enlarging the unit cell. For x = 0.37, the application of external pressures enhances the interlayer antiferromagnetic coupling, boosting the Néel temperature at a rate of 1.4 K/GPa and the saturation field at a rate of 1.8 T/GPa. Furthermore, our first-principles calculations reveal that the band inversion in the two end materials, MnBi 2 Te 4 and PbBi 2 Te 4 , occurs at the Γ and Z point, respectively, while two gapless points appear at x = 0.44 and x = 0.66, suggesting possible topological phase transitions with doping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation: Preprint

Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamics of heavy quarks in strongly coupled $\mathcal{N}$ = 4 SYM plasma

We calculate the probability distribution P(k) for a heavy quark with velocity v propagating through strongly coupled N = 4 SYM plasma in the ’t Hooft limit (N c → ∞, λ = g 2 N c → ∞) at a temperature T to acquire a momentum k due to interactions with the plasma. This distribution encodes the well-known drag coefficient η D and the transverse and longitudinal momentum diffusion coefficients κ T and κ L . The jet quenching parameter $\hat{q}$ can be extracted from P(k) for v = 1. Going beyond these known Gaussian characteristics of P(k), our calculation determines all of the higher order and mixed moments to leading order in 1/$\sqrt{λ}$ for the first time. These non-Gaussian features of P(k) include qualitatively novel correlations between longitudinal energy loss and transverse momentum broadening at nonzero v. We show that all higher moments scale characteristically with an effective temperature of the boosted plasma in the heavy quark rest frame, and we demonstrate that these non-Gaussian characteristics can be sizable in magnitude and even dominant in physically relevant situations. We use these results to derive a Kolmogorov equation for the evolution of the probability distribution for the total momentum of a heavy quark that propagates through strongly coupled plasma. This evolution equation accounts for all higher order correlations between transverse momentum broadening and longitudinal energy loss, which we have calculated from first principles. It reduces to a Fokker-Planck equation when truncated to only include the effects of η D , κ T and κ L . Remarkably, while heavy quarks do not reach kinetic equilibrium with the plasma if evolved with this Fokker-Planck equation, by showing that the Boltzmann distribution is a static solution of the all-order Kolmogorov equation that we have derived we demonstrate that heavy quarks do reach kinetic equilibrium if evolved with this equation. Our results thus provide a dynamically complete framework for understanding the thermalization of a heavy quark that may be initially far from equilibrium in the strongly coupled N = 4 SYM plasma — as well as new insight into heavy quark transport and equilibration in quark-gluon plasma.

Holography and Hydrodynamics↗

Utilizing GEOPHIRES-X Beyond Electricity

The GEOPHIRES tool is a techno-economic simulator for evaluating the thermal performance and cost-competitiveness of geothermal plants for electricity, heating, and/or cooling. The tool combines reservoir, wellbore, and surface plant cost and performance models to estimate overall techno-economic metrics such as net present value or levelized cost of electricity, heating, or cooling. We recently upgraded the tool to an object-oriented Python framework, presented in an accompanying paper. As part of the upgrade, we enhanced the capability to simulate the performance of geothermal plants for heating and cooling, which is the topic of this paper. Specifically, we (1) integrated absorption chillers to investigate the performance of utilizing geothermal heat for cooling, (2) integrated a heat pump module to boost the geothermal temperature and thermal output, (3) integrated a district heating module to estimate heating demand for a district based on local weather data, and simulated heat supply with geothermal energy and peaking boilers, and (4) integrated GEOPHIRES as an engine in the dGeo simulator to perform a geospatial analysis of geothermal district heating feasibility across a large region (e.g., a state or the entire United States) utilizing resource and thermal demand maps. This paper presents background information and case studies for several of these heating and cooling end-use options in GEOPHIRES.

absorption chiller↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation

Advanced district thermal energy systems, also known as thermal microgrids, can meet the energy needs of urban districts in a highly efficient way, but adoption of such systems, especially in the United States, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degrees F; 15-25 degrees C) temperatures, and water-source heat pumps at connected buildings are used to boost or lower the temperature for space conditioning and service hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to accelerating their adoption. This paper aims to contribute to that by reporting preliminary results from a feasibility study of a thermal microgrid at a U.S. Department of Defense installation and illustrating the process of conceptual design to seek the best possible performance within the many constraints of existing buildings. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for resilience and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Three-Dimensional CFD Investigation of Pre-Spark Heat Release in a Boosted SI Engine

Low-temperature heat release (LTHR) in spark-ignited internal combustion engines is a critical step toward the occurrence of auto-ignition, which can lead to an undesirable phenomenon known as engine knock. As such, correct predictions of LTHR are of utmost importance to improve the understanding of knock and enable techniques aimed at controlling it. While LTHR is typically obscured by the deflagration following the spark ignition, extremely late ignition timings can lead to LTHR occurrence prior to the spark, i.e., pre-spark heat release (PSHR). In this research, PSHR in a boosted direct-injection SI engine was numerically investigated using three-dimensional computational fluid dynamics (CFD). A hybrid approach was used, based on the G-equation model for representing the turbulent flame front and the multi-zone well-stirred reactor model for tracking the chemical reactions within the unburnt region. A recently developed best practice was also employed which keeps the well-stirred reactor model active throughout the entire simulation. This allowed for correct predictions of the previous cycle trapped residuals which have a considerable effect on the onset of LTHR. Multi-cycle simulations were conducted using Co-Optima alkylate and E30 fuels. The predicted in-cylinder pressure and heat release rate agreed well with the experimental data and served as validation for the CFD model. Following the initial validation, the dynamics of PSHR was discussed and a series of parameters of interest were assessed. First, the effect of exhaust valve temperature was investigated, qualitatively highlighting the importance of boundary conditions uncertainty. Further analyses were carried out on the effects of fuel properties, including laminar flame speed (LFS) and heat of vaporization (HOV). The results indicate that PSHR phasing is slightly advanced with lower LFS as more trapped unburnt fuel is made available for the next cycle. A similar trend was observed with lower HOV as less intense spray cooling led to higher mixture temperatures, i.e., higher mixture reactivity. Finally, a comparison of Co-Optima alkylate and E30 fuels was made using the pressure-temperature trajectory framework. It was shown that the differences between Co-Optima alkylate and E30 in PSHR tendency are correlated with both HOV and chemical effects.

33 ADVANCED PROPULSION SYSTEMS↗

New insights into fuel blending effects: Intermolecular chemical kinetic interactions affecting autoignition times and intermediate-temperature heat release

Fuel blending effects on chemically-dominated fuel properties, such as gasoline anti-knock quality, are influenced by fundamental chemical kinetic interactions between the blending agent and the base fuel. Historically, quantification of such interactions has focused on changes to the radical pool, including $\dot{O}$H and HO 2 , while intermolecular interactions pertaining to carbonated, non-fuel-specific intermediates are typically overlooked. In this regard, this work aims to derive new insight into intermolecular chemical kinetic interactions that are intrinsic to fuel blending effects via a case study on blends of 0–30% ethanol (by volume) into FGF-LLNL (a multi-component gasoline surrogate for FACE-F research gasoline) using a rapid compression machine at a diluted/stoichiometric fuel loading, compressed pressure of 40 bar and low- to intermediate-temperature regimes that are representative of boosted SI engine operation. Ethanol blending effects on the intermediate temperature heat release (ITHR) of FGF-LLNL are characterized using experimental measurements, where ethanol is found to promote the extent of ITHR and suppress the transition from ITHR to main ignition. Chemical kinetic modeling is undertaken using a recently updated gasoline surrogate model. Sensitivity analyses on ITHR characteristics further corroborate the ethanol blending effects, and highlight the significant dependence of ITHR on both fuel-specific and non-fuel-specific reactions. An approach allowing comprehensive characterization of the complex intermolecular chemical kinetic interactions between constitutes in a fuel blend is then proposed. Application of the approach to FGF-LLNL/E0–E30 reveals that ethanol perturbs the heat release and autoignition characteristics of FGF-LLNL not only by directly changing the $\dot{O}$H and HO 2 radical pools via fuel-specific reactions, but also through intermolecular interactions where participating intermediates can be produced and consumed by various sub-chemistries. Disabling the intermolecular interactions in carbonated species between ethanol and FGF-LLNL sub-chemistries leads to somewhat slower ITHR evolution and lower ignition reactivity. The role of the individual intermolecular interaction is also characterized using the proposed approach. Lastly, implications of intermolecular interactions for future studies that aim to improve model performance are highlighted, where it is found that further investigations on the core C0-C4 chemistry are needed for developing highly accurate chemistry models for complex fuel blends.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Additive-Mixing Fuel Injection (AMFI): A device for robust control and improved performance of high-efficiency LTGC engines

Low-temperature gasoline combustion (LTGC) engines can provide high efficiencies with very low NOx and particulate emissions. Despite these major advantages, methods for controlling LTGC combustion timing, achieving robust autoignition, and good low-load performance have challenged the development of practical LTGC engines. A key reason is that the ideal reactivity of the fuel varies with operating conditions, with low-reactivity fuels working well at high loads and higher-reactivity fuels working better at low loads. This article introduces a new technique called Additive Mixing Fuel Injection (AMFI) that adjusts the reactivity of the gasoline to obtain good performance over the operating map. Moreover, AMFI can provide robust combustion-timing control because it precisely meters very small amounts (0.01–0.6 mm 3 ) of an ignition-enhancing additive into the fuel each engine cycle. The additive used was 2-ethylhexyl nitrate (EHN), a common, inexpensive diesel-fuel ignition improver, but other additives could be used. Because additive amounts are so small, a 2-gal reservoir would be sufficient for medium-duty applications with refilling only at service intervals of about 8000 mi. The AMFI system has been installed on a single-cylinder LTGC research engine and demonstrated to provide robust combustion-timing control over wide ranges of combustion phasing, fueling rate, intake boost, engine speed, and intake temperature. AMFI also increases the fuel’s reactivity sufficiently to greatly reduce or eliminate the need for charge heating, simplifying engine design and significantly increasing thermal efficiency and the maximum load at low-boost conditions. The nitrogen in the EHN produced a modest increase in NOx, but it was mitigated by lower intake temperatures, and NOx emissions remained very low. Finally, the additive increases the sensitivity of autoignition reactions to variations in the local fuel/air mixture within the charge. This allows the use of controlled fuel stratification for improved LTGC-engine performance, and its potential to improve low-load operation was demonstrated.

Dec, John E.↗

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ecosystem and soil respiration radiocarbon detects old carbon release as a fingerprint of warming and permafrost destabilization with climate change

The permafrost region has accumulated organic carbon in cold and waterlogged soils over thousands of years and now contains three times as much carbon as the atmosphere. Global warming is degrading permafrost with the potential to accelerate climate change as increased microbial decomposition releases soil carbon as greenhouse gases. A 19-year time series of soil and ecosystem respiration radiocarbon from Alaska provides long-term insight into changing permafrost soil carbon dynamics in a warmer world. Nine per cent of ecosystem respiration and 23% of soil respiration observations had radiocarbon values more than 50‰ lower than the atmospheric value. Furthermore, the overall trend of ecosystem and soil respiration radiocarbon values through time decreased more than atmospheric radiocarbon values did, indicating that old carbon degradation was enhanced. Boosted regression tree analyses showed that temperature and moisture environmental variables had the largest relative influence on lower radiocarbon values. This suggested that old carbon degradation was controlled by warming/permafrost thaw and soil drying together, as waterlogged soil conditions could protect soil carbon from microbial decomposition even when thawed. Overall, changing conditions increasingly favoured the release of old carbon, which is a definitive fingerprint of an accelerating feedback to climate change as a consequence of warming and permafrost destabilization.

54 ENVIRONMENTAL SCIENCES↗

Synergistic promotion of transition metal ion-exchange in TiO 2 nanoarray-based monolithic catalysts for the selective catalytic reduction of NO x with NH 3

TiO 2 supported catalysts have been widely studied for the selective catalytic reduction (SCR) of NO x ; however, comprehensive understanding of synergistic interactions in multi-component SCR catalysts is still lacking. For this work, transition metal elements (V, Cr, Mn, Fe, Co, Ni, Cu, La, and Ce) were loaded onto TiO 2 nanoarrays via ion-exchange using protonated titanate precursors. Amongst these catalysts, Mn-doped catalysts outperform the others with satisfactory NO conversion and N 2 selectivity. Cu co-doping into the Mn-based catalysts promotes their low-temperature activity by improving reducibility, enhancing surface Mn 4+ species and chemisorbed labile oxygen, and elevating the adsorption capacity of NH 3 and NO x species. While Ce co-doping with Mn prohibits the surface adsorption and formation of NH 3 and NO x derived species, it boosts the N 2 selectivity at high temperatures. By combining Cu and Ce as doping elements in the Mn-based catalysts, both the low-temperature activity and the high-temperature N 2 selectivity are enhanced, and the Langmuir–Hinshelwood reaction mechanism was proved to dominate in the trimetallic Cu–Ce–5Mn/TiO 2 catalysts due to the low energy barrier.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Replicating HCCI-like autoignition behavior: What gasoline surrogate fidelity is needed?

This work seeks to characterize the fidelity needed in a gasoline surrogate with the intent to replicate the complex autoignition behavior exhibited within advanced combustion engines, and specifically Homogeneous Charge Compression Ignition (HCCI). A low-temperature gasoline combustion (LGTC) engine operating in HCCI mode and a rapid compression machine (RCM) are utilized to experimentally quantify fuel reactivity, through autoignition and preliminary heat release characteristics. Fuels considered include a research grade E10 U.S. gasoline (RD5-87), three multi-component surrogates (PACE-1, PACE-8, PACE-20), and a binary surrogate (PRF88.4). Each fuel was studied at lean/HCCI-like conditions covering a wide range of temperatures and pressures that are representative of naturally aspirated to high boost engine operation. Detailed chemical kinetic modeling is also undertaken using a recently updated gasoline surrogate kinetic model to simulate the RCM experiments and to provide chemical insight into surrogate-to-surrogate differences. The LGTC engine experiments demonstrate nearly identical reactivity between PACE-20 and RD5-87 across studied conditions, while faster phasing is seen for both PACE-1 and PACE-8 due to their stronger intermediate- and low-temperature heat release (ITHR/LTHR) at naturally aspirated and boosted conditions, respectively. The RCM experiments reveal typical low-temperature, negative temperature coefficient (NTC) and intermediate-temperature autoignition behaviors at all pressure conditions for RD5-87, which are qualitatively reproduced by all surrogates. Quantitative discrepancies in both autoignition and preliminary heat release are observed for all surrogates, while their ability to replicate RD5-87 autoignition behavior follows the order of PACE-20 > PACE-1 > PACE-8 > PRF88.4. Excellent mapping is obtained between the LGTC engine and the RCM, where the engine pressure-time trajectories can be characterized by the regimes represented by the RCM autoignition isopleths. The kinetic model performs commendably when simulating both autoignition and preliminary heat release of PACE-20, while typically overpredicting ignition delay times for PACE-1, PACE-8 and PRF88.4 at high-pressure and low-temperature/NTC conditions. Sensitivity and rate of production (ROP) analyses highlight surrogate-to-surrogate differences in the governing chemical kinetics where n-pentane initiates rapid OH branching at a faster rate and an earlier timing for PACE-20 than iso-pentane does for PACE-1 and PACE-8, making it computationally more reactive than the other surrogates. The current study highlights the need to include non-standardized properties, such as the lean/HCCI-like autoignition characteristics, in addition to ASTM properties (e.g., RON, MON) as metrics of fuel reactivity and targets to be matched when formulating high-fidelity surrogates that fully capture gasoline advanced combustion behavior such as HCCI-like autoignition.

42 ENGINEERING↗

Experimental and modeling study of C2–C4 alcohol autoignition at intermediate temperature conditions

C2–C4 alcohols are advantageous blendstocks identified by many research groups, including the U.S. Department of Energy Co-Optima Initiative, towards enabling efficient, boosted Spark-Ignition (SI) engines. Their use in advanced engine applications requires a comprehensive understanding of their intermediate-temperature autoignition behavior. This work reports an experimental and modeling study covering their fundamental autoignition characteristics in a twin-piston rapid compression machine at pressures of 20 and 40 bar, intermediate temperatures from 750 to 980 K, and two fuel loading conditions representative of boosted SI engines. Direct comparison between these alcohols is made, where the order of reactivity is established across different thermodynamic and fuel loading conditions. Changes in preliminary exothermicity (or intermediate-temperature heat release) displayed in single-stage autoignition across different alcohols and conditions are also quantified. This provides insight into fuel-to-fuel differences, and how these could affect advanced combustion concepts such as spark-assisted compression ignition. Kinetic models are used to simulate the experiments, and reasonable agreement is obtained. Furthermore, the sensitivity analysis results demonstrate the importance of accurately capturing the autoignition kinetics, particularly H-abstraction reactions on the parent fuels by OH and HO 2 , and the branching ratio associated with these.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗