Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TUBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Novel Capsule Fill Tube Assemblies for the Hydrodynamic Growth Radiography Targets

Capsule Fill Tube Assemblies (CFTAs) consist of an ablator capsule and fill tube via a laser drilled funnel hole. This hole then tapers from 17 μm diameter at the outer surface of the ablator capsule to less than 5 μm diameter on the inside of the capsule over approximately 200 μm of wall thickness. Demand for better understanding of the fill tube perturbation during the capsule implosion has driven advancements in the fill tube design. Engineering efforts have been made on Hydrodynamic Growth Radiography Assemblies (HGRs) using multiple tube design variations, including alternative angles, depths, sizes, and location with engineered defects to showcase fill tube effects during an implosion. Furthermore, testing has shown that these CFTAs and HGRs have survived all fabrication and transport to from General Atomics to Lawrence Livermore National Laboratory. These assemblies have also passed cryogenic testing at General Atomics. An overview of alternative CFTA designs, fabrication methods and developments will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Penetration of Ar and He RF-driven plasma jets into micrometer-sized capillary tubes

The penetration and propagation of cold atmospheric pressure plasmas into volumes having sub-millimeter to micrometer sizes with large aspect ratios is required for enabling an effective disinfection of the inside of catheter tubes, tooth cavities, skin pores and enhance plasma catalysis in porous catalysts. Here, we report on a study using a low voltage RF driven argon and helium plasma jets with the plasma generation outside a capillary tube with a large aspect ratio followed by its penetration and propagation inside the capillary. We present the experimental determination of the limitations on the penetration diameter, and the underpinning mechanisms of the plasma propagation and penetration process. Experimental results include time resolved imaging of plasma propagation and penetration in capillaries with different internal diameter and surface electric field measurements. We found that the time between the plasma jet in first contact with the capillary tube surface and the subsequent penetration into the capillary tube spans several RF cycles due to electric fields at the plasma-tube interface below 4 kV cm –1 . These low electric fields require Penning ionization and/or stepwise ionization and hence a buildup of the metastable and electron density is required to achieve a sufficiently large ionization rate near the capillary tube inlet to enable penetration and propagation. Furthermore, it is found that the propagation of the argon jet into the capillary occurs during the positive half cycle of the RF waveform and is very similar to the propagation of the jet in surrounding air.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Siphon flows in isolated magnetic flux tubes. IV - Critical flows with standing tube shocks

Critical siphon flows in arched, isolated magnetic flux tubes are studied within the thin flux tube approximation, with a view toward applications to intense magnetic flux concentrations in the solar photosphere. The results of calculations of the strength and position of the standing tube shock in the supercritical downstream branch of a critical siphon flow are presented, as are calculations of the flow variables all along the flux tube and the equilibrium path of the flux tube in the surrounding atmosphere. It is suggested that arched magnetic flux tubes, with magnetic field strength increased by a siphon flow, may be associated with some of the intense, discrete magnetic elements observed in the solar photosphere.

Thomas, John H.↗

Heat Transfer from High-Temperature Surfaces to Fluids. III - Correlation of Heat-Transfer Data for Air Flowing in Silicon Carbide Tube with Rounded Entrance, Inside Diameter of 3/4 Inch, and Effective Length of 12 Inches: Correlation of Heat-Transfer Data for Air Flowing in Silicon Carbide Tube with Rounded Entrance, Inside Diameter of 3/4 Inch, and Effective Length of 12 Inches - Part 3

A heat-transfer investigation was conducted with air flowing through an electrically heated silicon carbide tube with a rounded entrance, an inside diameter of 3/4 inch, and an effective heat-transfer length of 12 inches over a range of Reynolds numbers up to 300,000 and a range of average inside-tube-wall temperature up to 2500 R. The highest corresponding local outside-tube-wall temperature was 3010 R. Correlation of the heat-transfer data using the conventional Nueselt relation wherein physical properties of the fluid were evaluated at average bulk temperature resulted in a separation of data with tube-wall-temperature level. A satisfactory correlation of the heat-transfer data was obtained, however, by the use of modified correlation parameters wherein the mass velocity G (or product of average air density and velocity evaluated at bulk temperature P(sub b)V(sub b)) in the Reynolds number was replaced by the product of average air velocity evaluated at the bulk temperature and density evaluated at either the average inside-tube-wall temperature or the average film temperature; in addition, all the physical properties of air were correspondingly evaluated at either the average inside-tube-wall temperature or the average film temperature.

Sams, Eldon W.↗

The Effect of Antiphase Boundary Tubes on the Hardness of FeAl

The high work hardening rate unique to ordered intermetallic alloys has long been attributed to antiphase boundary (APB) tubes. In this work, APB tubes are introduced in Fe–40 at. pct Al and Fe–43 at. pct Al by cold-rolling and then removed by annealing. The presence and absence of APB tubes is verified with magnetic measurements. When APB tubes are annealed out the hardness does not change, thus indicating that APB tubes do not contribute to strengthening.

36 MATERIALS SCIENCE↗

Orbital tube flare for tubing connectors

Marshall engineering personnel have developed and are now refining a new and unique method of mechanically flaring tubing. The system eliminates the use of the conventional split backing die which is used with most tube-flaring equipment. The Marshall-developed tool is adapted for use on standard Leonard 3-CP-HD flaring machines. The stationary split backing die is replaced in function with a die ring, whose i.d.-surface rolls or orbits around the o.d. of the tube flare zone. An i.d.-flaring cone moves axially and forces the metal against the rolling die to form the flare. Major advantages of this system are the elimination of flash, or split die marks, on the back angle of the flare, and improved flare-surface finishes, permitting more uniform sealing characteristics and improvements of the total geometric configuration of the flare as required by the MSFC specification MC-146. The Orbital Adapter system of tooling is currently being used to manufacture flared tube hardware for the Saturn V S-IO space launch vehicle at MSFC, for the Agena space launch vehicle (used for the Gemini project) at Lockheed, Sunnyvale, for LEM checkout equipment for Grumman, and for the Saturn S-IV-B space launch vehicle by Douglas Aircraft Company. Several other aerospace firms are evaluating the system for possible incorporation on their tube flaring requirements. Marshall engineers are now concentrating their efforts on refining and reducing the total cost of the overall system.

Tubing↗

Manipulation of mass transport rates using bead-in-a-tube method

In ultralow Pu analyses, the gold standard is thermal ionization mass spectrometry (TIMS), which requires pure sources to achieve its performance. This purity is achieved through step-wise purifications. In this work single anion-exchange beads were trapped in tubing to allow for dynamic solution cycling over the surface of the beads to improve the rates of metal complex uptake. Rates of Pu sorption on single ~900 µm SIR-1200 and ~620 µm Reillex-HPQ beads were determined for single beads trapped in a tube with syringe pump driven dynamic solution cycling over the bead, improving sorption and desorption rates. A static control was used as a comparison. Using 238Pu to enable facile activity-based measurements, rates were determined by measuring the residual Pu after contact with beads using liquid scintillation analysis (LSA) for fixed periods of time. Syringe pump driven dynamic solution cycling results in ~5 and ~15-fold improvements in the sorption rates for SIR-1200 and Reillex-HPQ. Impacts on desorption were also examined.

Bead-in-a-tube, Mass Transport Rates↗

In tube condensation of low global warming potential refrigerants in an axial micro-fin aluminum tube

Environmental regulations have driven the development of refrigerants with low global warming potential (GWP). To design heat exchangers using these new refrigerants, data are needed concerning the heat transfer coefficient and pressure drop in two-phase flow. Another change is the increasing use of aluminum tubes rather than copper tubes to reduce heat exchanger cost. Hence, this study presents an experimental investigation of flow condensation using an expanded axial micro-fin aluminum tube with a fin-tip diameter of 5.96 mm. Here, the experiments included single compounds R-32, R-1234yf, and R-1234ze(E), zeotropic mixtures with low glide (R-454B), and zeotropic mixtures with high-glide (R-454C and R-455A). Experiments were conducted at condensation temperatures ranging from 40 °C to 50 °C, reduced pressures ranging from 0.21 to 0.55, and mass fluxes ranging from 150 to 350 kg/(m 2 s). Data obtained for these refrigerants constitute one of the first reports for high-glide refrigerants using axial micro-fin aluminum tubes. An evaluation of heat transfer degradation of zeotropic mixtures due to mass transfer resistance at the liquid/vapor interface is presented. This information can be used to design heat exchangers for next generation air conditioning and refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The effect of voltage waveform and tube diameter on transporting cold plasma strings through a flexible dielectric tube

In this work, we developed transporting atmospheric pressure cold plasma using single electrode configuration through a sub-millimetre flexible dielectric tube beyond 100 cm. It was shown that the waveform of the applied high voltage is essential for controlling upstream and downstream plasma inside the tube. In this regard, sawtooth waveform enabled the transport of plasma with less applied high voltage compared to sinusoidal and pulsed form voltages. A cold plasma string as long as 130 cm was obtained by only 4 kV peak-to-peak sawtooth high voltage waveform. Optical emission spectroscopy revealed that reactive chemical species, such as atomic oxygen and hydroxyl, are generated at the tube exit. The effect of tube diameter on the transported plasma was also examined: the smaller the diameter, the higher the applied voltage. The device is likely to be used for sterilization, decontamination, and therapeutic endoscopy as already suggested by other groups in recent past years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Practical acoustic thermometry with twin-tube and single-tube sensors

Accurate measurement of high temperatures in a nuclear environment presents unique challenges. All secondary techniques inevitably drift because the thermometric materials in thermocouples and resistance sensors are sensitive not just to temperature, but also their own chemical and physical composition. The solution is to use primary methods that rely on fundamental links between measurable physical properties and temperature. In the nuclear field the best known technique is the measurement of Johnson Noise in a resistor (See Paper 80 at this conference). In this paper we describe the measurement of temperature in terms of the speed of sound in a gas confined in a tube - an acoustic waveguide. Acoustic thermometry is the most accurate technique of primary thermometry ever devised with the best uncertainty of measurement below 0.001 C. In contrast, the acoustic technique described in this work has a much larger uncertainty, approximately 1 deg. C. But the cost and ease of use are improved by several orders of magnitude, making implementation eminently practical. We first describe the basic construction and method of operation of thermometers using twin-tubes and single tubes. We then present results using a twin-tube design showing that showing long term stability (i.e. no detectable drift) at 700 deg. C over periods of several weeks. We then outline how the technique may be developed for different nuclear applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sunspots and the physics of magnetic flux tubes. V - Mutual hydrodynamic forces between neighboring tubes

The mutual hydrodynamic forces between parallel cylinders in a moving fluid are illustrated through several formal examples. Parallel tubes in a uniform flow are attracted or repelled depending on whether they are side by side or one ahead of the other, respectively. A pulsating or undulating tube attracts all other neighboring tubes toward itself. These hydrodynamic effects suggest that the separate flux tubes beneath the sunspots exert significant attractive forces on each other.

Parker, E. N.↗

On the generation of flux tube waves in stellar convection zones. I - Longitudinal tube waves driven by external turbulence

The source functions and the energy fluxes for wave generation in magnetic flux tubes embedded in an otherwise magnetic field-free, turbulent, and compressible fluid are derived. The calculations presented here assume that the tube interior is not itself turbulent, e.g., that motions within the flux tube are due simply to external excitation. Specific results for the generation of longitudinal tube waves are presented.

Musielak, Z. E.↗

Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2

The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas facility. The algorithm output consists of a pair of correction constants per chamber which are applied to baseline calibrations, and determined to be valid for the entire ATLAS Run 2. The final single-hit spatial resolution, averaged over 1172 monitored drift tube chambers, is $81.7 \pm 2.2 \mu$m.

47 OTHER INSTRUMENTATION↗

Which G-Tube to Use in Pullers: Assessment of Pull Pressures on Skin Models to Determine Optimal Catheter Choice in Patients with Recurrent Pulled Gastrostomy Tubes

Introduction: Pulled or dislodged gastrostomy catheters represent a common complication associated with percutaneous gastrostomy and are a common cause of recurrent visits in patients with altered mental status. We intended to perform an experiment to compare the pull forces required to dislodge different commonly used gastrostomy catheters. Materials and Methods: We used a digital force gauge device to measure the pull forces required to dislodge three types of 20 French gastrostomy catheters in double-layer skin models. These included the Flow 20 Pull Method (Cook Medical, Bloomington, IN, USA), Entuit Gastrostomy BR Balloon Retention feeding tube (Cook Medical, Bloomington, IN, USA), and Ponsky Non-Balloon Replacement Gastrostomy Tube (CR Bard Inc, Salt Lake City, Utah, USA). The catheters were inserted into the skin model using the same technique as would be utilized in a patient. Results: The mean forces measured to dislodge the per-oral Flow 20 Pull Method, Entuit Thrive Balloon Retention, and button-type retention Ponsky replacement catheters were 35.6, 22.8, and 20.6 Newtons, respectively. The pull method per-oral gastrostomy catheter required significantly more pull force to dislodge than both the Ponsky button-type retention catheter and the Entuit balloon retention catheters. There was no significant difference in the pull force required to dislodge the Ponsky replacement catheter and the Entuit balloon retention catheter. Conclusions: Per-oral image-guided gastrostomy with pull-method button-type retention catheters may be the ideal choice in patients at high risk of tube dislodgment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗