Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TRIGGER LOGIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

E-1039 "SpinQuest" FPGA Trigger

The SpinQuest experiment will measure an azimuthal asymmetry in the Drell-Yan production of $\mu+$ $\mu-$ pairs from 120 GeV/c proton interactions with polarized nucleons to extract the Sivers function for $\bar{u}$ and $\bar{d}$. A large combinatorial background from muons produced in the beam dump requires a trigger which is capable of identifying dimuon pairs originating from the target in a high rate environment. The trigger system consists of four stations of scintillator hodoscopes whose 96 channels are digitized and processed by field-programmable gate array (FPGA) based VMEbus modules. Hodoscope hit patterns are compared to predetermined sets, chosen from Monte Carlo simulations, in a tiered lookup table to generate trigger decisions. The design and current status of the FPGA trigger will be presented and planned upgrades to the trigger logic will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Angular Distributions of High-Mass Dilepton Production in Hadron Collisions

The SeaQuest experiment is a fixed-target dimuon experiment currently running at the Fermi National Accelerator Laboratory (FNAL). By utilizing the high-intensity, 120 GeV proton beam delivered by the FNAL Main Injector (MI), SeaQuest is able to measure proton-induced Drell-Yan dimuon production off of various nuclear targets in kinematic regions inaccessible to previous similar experiments. A suitably large fraction of the final dataset has been recorded, reconstructed, and analyzed. Very preliminary results from light-sea flavor asymmetry, nuclear dependence, and partonic energy loss analyses have been presented at numerous international conferences. A novel, FPGA-based trigger system has been designed, implemented, and optimized for the SeaQuest experiment. By implementing the trigger decision logic in FPGA firmware, it is more adaptable to changing experimental conditions. Additionally, the peripheral tasks of timing alignment, “trigger matrix” generation, and firmware uploading have been mostly automated, reducing the likelihood of user error in the maintenance and operation of the trigger system. Significant upgrades to hardware and firmware have greatly improved the performance of the trigger system since the 2012 commissioning run of SeaQuest. Four additional v1495 modules were added to facilitate thorough pulser testing of the firmware designs and in-situ pulser tests of all compiled firmware. These pulser tests proved crucial for diagnosing many errors that may have otherwise gone unnoticed. A significant change to the internal clocking of the trigger system eliminated a subtle source of rate-dependent trigger efficiency. With this upgrade, the trigger finally meets the “dead-time free” design specification. Drell-Yan dimuon data have been collected and analyzed for central θCS , with nearly flat acceptance in φCS , in the mass range 5.0 GeV < Mγ* < 10.0 GeV at forward xF with the SeaQuest spectrometer at FNAL. A very preliminary extraction of λ has been performed, and the remaining difficulties in extracting ν have been evaluated. Although the results are not yet publishable, significant progress has been made in developing this very challenging angular distributions analysis. A simple scheme for correcting for the angular acceptances of the spectrometer, trigger, and reconstruction has been developed and demonstrated. A generally applicable correction for the kinematically-dependent, rate-dependent reconstruction efficiency has been developed and applied to all current analyses on SeaQuest data. This rate-dependence correction was the first major hurdle in the path to publication of many preliminary SeaQuest results. The last remaining major correction for all analyses, but especially important for the angular parameter extraction, is the full characterization, rate-dependence correction, and subtraction of the combinatoric background contribution to the reconstructed dimuon sample. Independently, an intuitive, kinematic derivation of the single-event definitions of the Drell-Yan angular parameters has been developed under the assumption of unpolarized annihilating quarks within unpolarized nuclei. At O(αs), where the quarks remain co-planar with the hadrons in the photon rest frame, this kinematic method reproduces the Lam-Tung relation and derives an additional equality for µ2, which is only interpretable for single-event parameters. This method has been extended to the case of quark non- coplanarity, and the coplanar equalities become inequalities. A new equality was discovered, which should be obeyed by single-event parameters even in the case of a non-coplanar quark axis. The non-coplanar parameter relations have been used to derive constraints on the experimentally accessible values of λ and ν. These constraints are compared with existing data and have been found consistent, except in the cases where significant contributions from non-zero Boer-Mulders functions are expected. Finally, the kinematically- derived parameter definitions have been applied to high-precision CMS data. The relative contributions of the qq¯ and qg processes to the Z-boson “Drell-Yan” cross-section have been extracted. Further, an average measure of non-coplanarity, likely caused by O(α2) and higher processes, has been extracted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Approach for Utilization of FPGA Technology into DAQ, DSP, and Computing Applications

Innovation Partners proposed and successfully demonstrated in this SBIR Phase I grant a software/hardware co-design approach to reduce both the difficulty and time to implement Field Programmable Gate Array (FPGA) solutions to data acquisition and specialized computational applications. FPGAs can require excessive time for programming and require specialized knowledge that will be greatly reduced by the company's solution. Not only are FPGAs ideal for DAQ and embedded solutions, they can also be the best solution to specialized signal processing to replace Digital Signal Processors (DSPs). By allowing FPGA programming to be done in C with the equivalent of a simple compilation, algorithm changes and improvements can be implemented decreasing the life-cycle costs and allow subsitution of new FPGA designs staying above the technological details.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for the Standard Model Higgs boson produced in association with a W Boson in the isolated-track charged-lepton channel using the Collider Detector at Fermilab

The Higgs boson is the only elementary particle predicted by the Standard Model (SM) that has not yet been observed experimentally. If it exists, it explains the spontaneous electroweak symmetry breaking and the origin of mass for gauge bosons and fermions. We test the validity of the SM by performing a search for the associated production of a Higgs boson and a W boson in the channel where the Higgs boson decays to a bottom-antibottom quark pair and the W boson decays to a charged lepton and a neutrino (the WH channel). We study a dataset of proton-antiproton collisions at a centre-of-mass energy √s = 1.96 TeV provided by the Tevatron accelerator, corresponding to an integrated luminosity of 5.7 fb -1 , and recorded using the Collider Detector at Fermilab (CDF).We select events consistent with the signature of exactly one charged lepton (electron or muon), missing transverse energy due to the undetected neutrino (MET) and two collimated streams of particles (jets), at least one of which is required to be identified as originating from a bottom quark. We improve the discrimination of Higgs signal from backgrounds through the use of an artificial neural network. Using a Bayesian statistical inference approach, we set for each hypothetical Higgs boson mass in the range 100-150 GeV/c 2 with 5 GeV/c 2 increments a 95% credibility level (CL) upper limit on the ratio between the Higgs production cross section times branching fraction and the SM prediction. Our main original contributions are the addition of a novel charged lepton reconstruction algorithm with looser requirements (ISOTRK) with respect the electron or muon tight criteria (TIGHT), as well as the introduction of a novel trigger-combination method that allows to maximize the event yield while avoiding trigger correlations and that is used for the ISOTRK category. The ISOTRK candidate is a high-transverse-momentum good-quality track isolated from other activity in the tracking system and not required to match a calorimeter cluster, as for a tight electron candidate, or an energy deposit in the muon detector, as for a tight muon candidate. The ISOTRK category recovers real charged leptons that otherwise would be lost in the non-instrumented regions of the detector. This allows the reconstruction of more W boson candidates, which in turn increases the number of reconstructed WH signal candidate events, and therefore improves the sensitivity of the WH search. For the TIGHT charged lepton categories, we employ charged-lepton-dedicated triggers to improve the rate of WH signal acceptance during data taking. Since there is no ISOTRK-dedicated trigger at CDF, for the ISOTRK charged lepton category we employ three MET-plus-jets-based triggers. For each trigger we first identify the jet selection where the trigger efficiency is flat with respect to jet information (transverse energy and direction of motion in the transverse plane for the two jets in the event) and then we parametrize the trigger efficiency as a function of trigger MET. On an event-by-event basis, for each trigger we compute a trigger efficiency as a function of trigger parametrization, trigger MET, jet information, trigger prescale and information about whether the trigger is defined or not. For the ISOTRK category we combine the three triggers using a novel method, which allows the combination of any number of triggers in order to maximize the event yield while avoiding trigger correlations. On an event-by-event basis, only the trigger with the largest efficiency is used. By avoiding a logical 'OR' between triggers, the loss in the yield of events accepted by the trigger combination is compensated by a smaller and easier-to-compute corresponding systematic uncertainty. The addition of the ISOTRK charged lepton category to the TIGHT category produces an increase of 33% in the WH signal yield and a decrease of 15.5% to 19.0% in the median expected 95% CL cross-section upper limits across the entire studied Higgs mass interval. The improvement in analysis sensitivity is smaller than the improvement in signal yield because the ISOTRK category has a smaller signal over background ratio than the TIGHT category, due to the looser ISOTRK reconstruction criteria. The observed (median expected) 95% CL SM Higgs upper limits on cross section times branching ratio vary between 2.39 x SM (2.73 x SM) for a Higgs mass of 100 GeV/c 2 to 31.1 x SM (31.2 x SM) for a Higgs mass of 150 GeV/c 2 , while the value for a 115 GeV/c 2 Higgs boson is that of 5.08 x SM (3.79 x SM). The novel trigger combination method is already in use by several CDF analyses. It is applicable to any analysis that uses triggers based on MET and jets, such as supersymmetry searches at the ATLAS and CMS experiments at the Large Hadron Collider. In its most general form, the method can be used by any analysis that combines any number of different triggers.

43 PARTICLE ACCELERATORS↗

A Reconfigurable Neural Network ASIC for Detector Front-End Data Compression at the HL-LHC

Despite advances in the programmable logic capabilities of modern trigger systems, a significant bottleneck remains in the amount of data to be transported from the detector to off-detector logic where trigger decisions are made. We demonstrate that a neural network (NN) autoencoder model can be implemented in a radiation-tolerant application-specific integrated circuit (ASIC) to perform lossy data compression alleviating the data transmission problem while preserving critical information of the detector energy profile. For our application, we consider the high-granularity calorimeter from the Compact Muon Solenoid (CMS) experiment at the CERN Large Hadron Collider. The advantage of the machine learning approach is in the flexibility and configurability of the algorithm. By changing the NN weights, a unique data compression algorithm can be deployed for each sensor in different detector regions and changing detector or collider conditions. To meet area, performance, and power constraints, we perform quantization-aware training to create an optimized NN hardware implementation. The design is achieved through the use of high-level synthesis tools and the hls4ml framework and was processed through synthesis and physical layout flows based on a low-power (LP)-CMOS 65-nm technology node. The flow anticipates 200 Mrad of ionizing radiation to select gates and reports a total area of 3.6 mm 2 and consumes 95 mW of power. The simulated energy consumption per inference is 2.4 nJ. Furthermore, this is the first radiation-tolerant on-detector ASIC implementation of an NN that has been designed for particle physics applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Video event trigger and tracking system using fuzzy comparators

A video observation method and apparatus, the apparatus having a frame storage mechanism, a dividing mechanism, a plurality of fuzzy comparators and a trigger signal mechanism. The frame storage mechanism stores at least one non-current video frame of a viewing field. The dividing mechanism divides a current video frame of the viewing field and the at least one non-current video frame into a plurality of corresponding trigger sections. The plurality of fuzzy comparators each compare and detect a fuzzy logic difference between one trigger section of the current video frame and the corresponding trigger sections of the at least one non-current video frame, the number of fuzzy comparators being selected so that every trigger section of the current video frame is compared. The trigger signal mechanism provides a trigger signal when a fuzzy logic difference is detected between any of the corresponding current and non-current trigger sections. A video observation mechanism and data reducing mechanism may be included with the above apparatus or alone with only a frame storage mechanism, a single generic comparator and a trigger signal mechanism. The video observation mechanism provides a video data stream, wherein each pixel of each frame of a viewing field is provided as multiple bits of data. The data reducing mechanism reduces each set of multiple bits of data which correspond to each pixel to one bit of binary data based on whether the pixel has a level of grey which is above or below a threshold level of grey.

Williams, Glenn L.↗

Deployable robotic woven wire structures and joints for space applications

Deployable robotic structures are basically expandable and contractable structures that may be transported or launched to space in a compact form. These structures may then be intelligently deployed by suitable actuators. The deployment may also be done by means of either airbag or spring-loaded typed mechanisms. The actuators may be pneumatic, hydraulic, ball-screw type, or electromagnetic. The means to trigger actuation may be on-board EPROMS, programmable logic controllers (PLCs) that trigger actuation based on some input caused by the placement of the structure in the space environment. The actuation may also be performed remotely by suitable remote triggering devices. Several deployable woven wire structures are examined. These woven wire structures possess a unique form of joint, the woven wire joint, which is capable of moving and changing its position and orientation with respect to the structure itself. Due to the highly dynamic and articulate nature of these joints the 3-D structures built using them are uniquely and highly expandable, deployable, and dynamic. The 3-D structure naturally gives rise to a new generation of deployable three-dimensional spatial structures.

Shahinpoor, MO↗

Study and improvement of the trigger system in ICARUS

In recent years, intriguing experimental neutrino anomalies have emerged. If confirmed, they could hint at the presence of additional sterile neutrino states playing in neutrino mixing. The Short-Baseline Neutrino project at Fermilab aims to delve into these anomalies, utilizing three Liquid Argon Time Projection Chamber detectors along the Booster Neutrino Beam. The SBND detector serves as nearby instruments, while MicroBooNE and ICARUS function as far detectors and also explore the NuMI beam off-axis. A relevant aspect in the functioning of all SBN detectors is the trigger system, that determines which interactions are recorded. In particular, in ICARUS, it relies on the synchronization of prompt signals from scintillation light within the LAr-TPC, detected by a system of Photo-Multiplier Tubes, with the proton beam’s spill extraction. The existing majority-based logic of the trigger system could potentially be enhanced through adder boards that sum analog signals from PMTs in groups of 15. This sum-based triggering might aid in identifying events near TPC walls, where light is abundant but captured by only a few PMTs, potentially bypassing the majority condition. Comprehensive tests have been performed to characterize these adder boards.

43 PARTICLE ACCELERATORS↗

Precision Compton polarimetry for the QWeak experiment at Jefferson Lab

The Q Weak experiment, scheduled to run in 2010-2012 in Hall C at Jefferson Lab, will measure the parity-violating asymmetry in elastic electron-proton scattering at 1.1 GeV to determine the weak charge of the proton, Q{sub Weak}{sup p} = 1 - 4 sin{sup 2} {theta}{sub W}. The dominant experimental systematic uncertainty will be the knowledge of the electron beam polarization. With a new Compton polarimeter we aim to measure the beam polarization with a statistical precision of 1% in one hour and a systematic uncertainty of 1%. A low-gain Fabry-Perot cavity laser system provides the circularly polarized photons. The scattered electrons are detected in radiation-hard diamond strip detectors, and form the basis for a coincidence trigger using distributed logic boards. The photon detector uses a fast, undoped CsI crystal with simultaneous sampling and integrating read-out. Coincident events are used to cross-calibrate the photon and electron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Novel Experimental Setup for Rare Events Selection and Its Potential Application to Super-heavy Elements Search

The paper presents a novel instrumentation for rare events selection which was tested in our research of short lived super heavy elements production and detection. The instrumentation includes an active catcher multi elements system and dedicated electronics. The active catcher located in the forward hemisphere is composed of 63 scintillator detection modules. Reaction products of damped collisions between heavy ion projectiles and heavy target nuclei are implanted in the fast plastic scintillators of the active catcher modules. The acquisition system trigger delivered by logical branch of the electronics allows to record the reaction products which decay via the alpha particle emissions or spontaneous fission which take place between beam bursts. One microsecond wave form signal from FADCs contains information on heavy implanted nucleus as well as its decays.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Systematic Framework for Tuning Open-Source Multifunctional IBR Models To Emulate OEM Black-Box Fault Dynamics

This paper presents a systematic framework to tune a generic IBR EMT model to match with an OEM provided balckbox inverter model based on the fault current responses. The key learnings and findings are summarized as follows: The tunable key parameters include inner control loops and current limiters to align the fault current magnitude, sequence content, and phase trajectories with the OEM models across diverse fault type and locations. The tuned model's fidelity is validated through comparative analysis with an OEM blackbox model, assessing both the fault current response and the responses of multiple relay elements. The results demonstrate the tuned generic model can trigger relay decision logic that is identical or near identical to that of the OEM model, thus generating very good match model for fault studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

N channel JFET based digital logic gate structure

A circuit topography is presented which is used to create usable digital logic gates using N (negatively doped) channel Junction Field Effect Transistors (JFETs) and load resistors, level shifting resistors, and supply rails whose values are based on the direct current (DC) parametric distributions of those JFETs. This method has direct application to the current state of the art in high temperature, for example 300.degree. C. to 500.degree. C. and higher, silicon carbide (SiC) device production. The ability to produce inverting and combinatorial logic enables the production of pulse and edge triggered latches. This scale of logic synthesis would bring digital logic and state machine capabilities to devices operating in extremely hot environments, such as the surface of Venus, near hydrothermal vents, within nuclear reactors (SiC is inherently radiation hardened), and within internal combustion engines. The basic logic gate can be configured as a driver for oscillator circuits allowing for time bases and simple digitizers for resistive or reactive sensors. The basic structure of this innovation, the inverter, can be reconfigured into various analog circuit topographies through the use of feedback structures.

Krasowski, Michael J.↗

Model-Based Fault Diagnosis: Performing Root Cause and Impact Analyses in Real Time

Generic, object-oriented fault models, built according to causal-directed graph theory, have been integrated into an overall software architecture dedicated to monitoring and predicting the health of mission- critical systems. Processing over the generic fault models is triggered by event detection logic that is defined according to the specific functional requirements of the system and its components. Once triggered, the fault models provide an automated way for performing both upstream root cause analysis (RCA), and for predicting downstream effects or impact analysis. The methodology has been applied to integrated system health management (ISHM) implementations at NASA SSC's Rocket Engine Test Stands (RETS).

Figueroa, Jorge F.↗

Results from the CBC3 readout ASIC for CMS 2S-modules

The CBC3 is the latest version of the CMS Binary Chip for readout of the outer radial region of the upgraded CMS Tracker at the High Luminosity LHC. This 254-channel, 130 nm CMOS ASIC is designed to be bump-bonded to a substrate to which sensors will be wire-bonded. It will instrument double-layer 2S-modules, containing two overlaid silicon microstrip sensors, aligned with a parallel orientation. On-chip logic identifies Level-1 trigger primitives from high transverse-momentum tracks by selecting correlated clusters in the two sensors. The CBC3 was delivered in late 2016; wafer probing and performance tests have been carried out. Several prototype modules using the CBC3 have been produced and tested in the lab and in different beams. The results show that the CBC3 satisfies CMS requirements and only small corrections are needed for the final version of the chip for production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single phase dynamic CMOS PLA using charge sharing technique

A single phase dynamic CMOS NOR-NOR programmable logic array (PLA) using triggered decoders and charge sharing techniques for high speed and low power is presented. By using the triggered decoder technique, the ground switches are eliminated, thereby, making this new design much faster and lower power dissipation than conventional PLA's. By using the charge-sharing technique in a dynamic CMOS NOR structure, a cascading AND gate can be implemented. The proposed PLA's are presented with a delay-time of 15.95 and 18.05 nsec, respectively, which compare with a conventional single phase PLA with 35.5 nsec delay-time. For a typical example of PLA like the Signetics 82S100 with 16 inputs, 48 input minterms (m) and 8 output minterms (n), the 2-SOP PLA using the triggered 2-bit decoder is 2.23 times faster and has 2.1 times less power dissipation than the conventional PLA. These results are simulated using maximum drain current of 600 micro-A, gate length of 2.0 micron, V sub DD of 5 V, the capacitance of an input miniterm of 1600 fF, and the capacitance of an output minterm of 1500 fF.

Dhong, Y. B.↗

Operational experience with the new CMS DAQ-Expert

The data acquisition (DAQ) system of the Compact Muon Solenoid (CMS) at CERN reads out the detector at the level-1 trigger accept rate of 100 kHz, assembles events with a bandwidth of 200 GB/s, provides these events to the high level-trigger running on a farm of about 30k cores and records the accepted events. Comprising custom-built and cutting edge commercial hardware and several 1000 instances of software applications, the DAQ system is complex in itself and failures cannot be completely excluded. Moreover, problems in the readout of the detectors,in the first level trigger system or in the high level trigger may provoke anomalous behaviour of the DAQ systemwhich sometimes cannot easily be differentiated from a problem in the DAQ system itself. In order to achieve high data taking efficiency with operators from the entire collaboration and without relying too heavily on the on-call experts, an expert system, the DAQ-Expert, has been developed that can pinpoint the source of most failures and give advice to the shift crew on how to recover in the quickest way. The DAQ-Expert constantly analyzes monitoring data from the DAQ system and the high level trigger by making use of logic modules written in Java that encapsulate the expert knowledge about potential operational problems. The results of the reasoning are presented to the operator in a web-based dashboard, may trigger sound alerts in the control room and are archived for post-mortem analysis - presented in a web-based timeline browser. We present the design of the DAQ-Expert and report on the operational experience since 2017, when it was first put into production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed, multi-channel, user programmable digital data acquisition system.

As applications for radiation detection become more demanding, and in turn improvements are made in the technology of radiation detection, there is a need for high speed digital detector readout electronics matching these improvements. Specifically, full control over the on-line processing resources of modern digital electronics is desirable so that researchers can develop custom algorithms for special applications.In the proposed effort, the 500 MHz digital readout electronics previously developed by our company will be redesigned to allow user access to the on-line processing resources. In Phase I, the division of online processing into vendor and user firmware sections has been studied on existing hardware. In Phase II, the hardware will be upgraded to better facilitate the division, and the firmware will be restructured into a robust vendor logic block (providing standard functions such as host I/O, on-board memory I/O, energy computation, MCA spectra, timestamps, waveform capture, run statistics, and triggering and timing) and a user logic block for custom algorithms (with templates and examples for frequently used functions). Investigating several options to divide online processing, it was determined that the most promising approach is to “partition” a single FPGA integrated circuit into a vendor and user section, which is supported in newer devices. The analog front end of the existing electronics proved suitable for most applications, in particular high rate measurements with germanium detectors. The design architecture for new electronics was developed, combining one of the new FPGA device with the analog front end.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High isolation RF signal selection switches

A selection switch with high isolation between RF signal input terminals is achieved with a gated Schmitt trigger circuit feeding into a control NAND gate in each signal switching channel. The control NAND gates of the separate signal channels are coupled to an output terminal by a single NAND gate. The schmitt trigger circuits and all gates are implemented with Schottky transistor-transistor logic circuits having input clamping diodes. Each Schmitt trigger circuit includes two cascaded NAND gates and a feedback isolation Schottky diode between one input terminal connected to receive an RF input and another input terminal connected to receive a feedback signal from the second of the two cascaded NAND gates. Both NAND gates of the Schmitt trigger circuits are enabled by the same switch control signal which enables the control gates.

Hanna, M. F.↗