Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TRANSITION RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The generation of transition radiation by relativistic particles in plastic foam radiators

The design of large area transition radiation detectors for highly relativistic particles can be greatly simplified if plastic foam radiators are employed. Using electron beams with energies 1-9 GeV at the Cornell synchrotron, we have studied the properties of a large variety of transition radiators consisting of commercially available foam materials. In most cases, a measurable transition radiation signal has been observed, but only a few materials have been found to be suitable for practical purposes. The observed radiation yield is in these cases very similar to that of equivalent multifoil radiators. A detailed discussion is given of the particle detection efficiency that can be obtained with high yield foam radiators.

Prince, T. A.↗

A new Transition Radiation detector based on GEM technology

Transition Radiation Detectors (TRD) have the potential feature of separating particles by their gamma factor. Classical TRDs are based on Multi-Wire Proportional Chambers (MWPC) or straw tubes, using a Xenon based gas mixture to efficiently absorb transition radiation photons. These detectors operate well in experiments with relatively low particle multiplicity. The performance of MWPC-TRD in experiments with luminosity of order 10 34 cm 2 s –1 and above, is significantly deteriorated due to the high particle multiplicity and channel occupancy. Replacing MWPC or straw tubes with a high granularity Micro Pattern Gas Detectors (MPGD) like Gas Electron Multipliers (GEMs), could improve the performance of the TRD. In addition, GEM technology allows one to combine a tracker with TRD identification (GEM-TRD/T). This report presents a new TRD development based on GEM technology for the future Electron Ion Collider (EIC). The first beam test was performed at Jefferson Lab (Hall-D) using 3–6 GeV electrons. A GEM-TRD/T module has been exposed to electrons with and without a fiber radiator. First results of test beam measurements and comparison with Geant4 Monte Carlo are introduced here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray transition radiation of electrons with energy of 300 to 900 MeV in periodic multifoil radiators

Results: of experiments conducted at the Tomsk synchrotron to study resonant X-ray transition radiation generated by relativistic electrons in periodic multifoil radiators are reviewed. Both the internal synchrotron beam and the external secondary electron beam from the pair magnetic γ-spectrometer with energies ranging from 300 to 900 MeV were used in the experiments. The radiators consisted of many thin amorphous foils of various materials. The generation of X-ray radiation in a compound radiator consisting of a multifoil radiator and a crystal is also studied. In this case, the resonant X-ray transition radiation generated in the multifoil radiator is diffracted in the crystal and emitted at Bragg angles, together with the parametric X-ray radiation generated in the crystal. Spectral and angular properties of the resonant X-ray transition radiation and diffracted resonant X-ray transition radiation are investigated. The ratio between the contributions from the diffracted resonant X-ray transition radiation and other types of radiation to the total coherent X-ray radiation flux generated by electrons in periodic structures and crystals is estimated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transition radiation from relativistic electrons in periodic radiators

The generation and detection of transition radiation have been studied in a series of experiments with electrons from 1 to 15 GeV at SLAC and at the Cornell Synchrotron. Periodic radiators, consisting of thin plastic foils stretched in air at constant spacings, were used, and proportional chambers filled with krypton or xenon served as detectors. A detailed discussion of the theoretical predictions is given, and the measurements are systematically compared with the predictions by varying the most critical parameters, such as configuration of radiators and detectors, and energy of the electrons. In general, good agreement between theory and experiment has been found. On the basis of these results, the criteria are summarized under which transition radiation can readily be observed.

Cherry, M. L.↗

A new transition radiation detector for cosmic ray nuclei

Test measurements on materials for transition radiation detectors at a low Lorentz factor are reported. The materials will be based on board Spacelab-2 for determining the composition and energy spectra of nuclear cosmic rays in the 1 TeV/nucleon range. The transition radiation detectors consist of a sandwich of radiator-photon detector combinations. The radiators emit X-rays and are composed of polyolefin fibers used with Xe filled multiwired proportional chamber (MWPC) detectors capable of detecting particle Lorentz factors of several hundred. The sizing of the detectors is outlined, noting the requirement of a thickness which provides a maximum ratio of transition radiation to total signal in the chambers. The fiber radiator-MWPC responses were tested at Fermilab and in an electron cyclotron. An increase in transition radiation detection was found as a square power law of Z, and the use of six radiator-MWPC on board the Spacelab-2 is outlined.

Lheureux, J.↗

Transition radiation of multicharged ions

The problem of the transition radiation of multicharged ions at the interface between two media and in a thin plate under the charge-exchange conditions has been solved. It has been shown that the processes of pickup (or loss) of electrons by accelerated multicharged ions at the interface between two media significantly increases the yield of transition radiation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Isotope Effect on Band Gap and Radiative Transitions Properties of Boron Nitride Nanotubes

We have carried out an isotope study on the band gap and radiative transition spectra of boron nitride nanotubes (BNNTs) using both experimental and theoretical approaches. The direct band gap of BNNTs was determined at 5.38 eV, independent of the nanotube size and isotope substitution, by cathodoluminescences (CL) spectra. At lower energies, several radiative transitions were observed, and an isotope effect was revealed. In particular, we confirmed that the rich CL spectra between 3.0 and 4.2 eV reflect a phonon-electron coupling mechanism, which is characterized by a radiative transition at 4.09 eV. The frequency red shift and peak broadening due to isotopic effect have been observed. Our Fourier transform infrared spectra and density functional theory calculations suggest that those radiative transitions in BNNTs could be generated by a replacement of some nitrogen atoms with oxygen.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Energy levels, radiative transitions and Auger transitions of the core excited states for B-like ions

Highlights: • Core excited states from 1s2s{sup 2}2p{sup 2} and 1s2s2p{sup 3} for B-like systems are studied. • Energy levels, radiative transitions and Auger transitions are calculated. • Radiative and Auger rates are discussed with nuclear charge numbers. - Abstract: Energy levels, radiative transitions and Auger transitions of the core excited states from 1s2s{sup 2}2p{sup 2} and 1s2s2p{sup 3 2,4} L (L=S,P,D) configurations for B-like systems including P{sup 10+}, Ca{sup 15+}, Mn{sup 20+}, and Zn{sup 25+} ions are calculated using the saddle-point variation and saddle-point complex-rotation methods. The first-order perturbation theory is used to calculate relativistic and mass polarization corrections. Present energy levels, radiative transition rates and wavelengths, Auger rates and electron energies are compared with theoretical and experimental values in the literature. The total radiative rates and the total Auger rates for these resonances are also discussed with nuclear charge numbers.

74 ATOMIC AND MOLECULAR PHYSICS↗

Diffraction effects in coherent transition radiation diagnostics for sub-mm bunch length measurement

Electrons crossing the boundary between different media generate bursts of transition radiation. In the case of bunches of N electrons, the radiation is coherent and has an N-squared enhancement at wavelengths related to the longitudinal bunch distribution. This coherent transition radiation has therefore attracted attention as an interceptive charged particle beam diagnostic technique. Many analytical descriptions have been devised describing the spectral distribution generated by electron bunches colliding with thin metallic foils making different simplifying assumptions. For typical bunches having lengths in the sub-millimeter range, measurable spectra are generated up into the millimeter range. Analysis of this THz radiation is performed using optical equipment tens of millimeters in size. This gives rise to concern that optical diffraction effects may spread the wavefront of interest into regions larger than the optical elements and partially escape detection, generating a wavelength-dependent instrument response. In this paper we present a model implementing vector diffraction theory to analyze these effects in bunch length diagnostics based on coherent transition radiation.

43 PARTICLE ACCELERATORS↗

The Kirchhoff method for transition radiation from flat and concave targets

Transition radiation (TR) emitted by a charged particle incident obliquely on a perfectly conducting surface is considered. A method is proposed that allows one to calculate the characteristics of backward radiation at a finite distance, including in the so-called pre-wave zone. Particular cases of a flat target, as well as a target in the form of a cylindrical surface whose axis is perpendicular to the trajectory of the particle are considered. In the first case, the radiation characteristics in the wave zone, calculated by the model proposed, are in complete agreement with available results. In the second case, when a detector is situated in the pre-wave zone, the radiation is focused. The properties of radiation are discussed as a function of the shape of the target surface, the angle of incidence of a particle, and the distance to the detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Medium-to-medium transition radiation and the detection of ultrarelativistic charged particles

The use of X-ray transition radiation to distinguish between protons and positrons of equal rigidity was investigated. A formula for the transition radiation spectrum from a medium-to-medium boundary was derived. The formation zone effect was found to limit the detection of transition radiation from ultrarelativistic particles. Curves showing the results of the spectrum calculations are presented.

Robbins, D. E.↗

Transition radiation as a source of cosmic X-rays.

It is shown that transition radiation generated during the passage of relativistic charged particles through interstellar grains can be an important source of cosmic X-rays. In order to account for recent X-ray observations below 300 eV by transition radiation, an energy density in interstellar space of about 10 eV per cu cm in 10 MeV electrons is required. This seems to rule out transition radiation as an important source of diffuse cosmic X-rays in any energy region.

Ramaty, R.↗

Commissioning and performance of the ATLAS transition radiation tracker with first high energy pp and Pb-Pb collisions at LHC

The ATLAS Transition Radiation Tracker (TRT) is the outermost of the three sub-systems of the ATLAS Inner Detector at the Large Hadron Collider at CERN. It consists of close to 300000 thin-wall drift tubes (straws) providing on average 30 two-dimensional space points with 0.12-0.15 mm resolution for charged particle tracks with |{eta}| < 2 and pt > 0.5 GeV. Along with continuous tracking, it provides particle identification capability through the detection of transition radiation X-ray photons generated by high velocity particles in the many polymer fibers or films that fill the spaces between the straws. Custom-built analog and digital electronics is optimized to operate as luminosity increases to the LHC design. In this article, a review of the commissioning and first operational experience of the TRT detector will be presented. Emphasis will be given to performance studies based on the reconstruction and analysis of LHC collisions. The first studies of the TRT detector response to the extremely high track density conditions during the November 2010 heavy ion LHC running period will be presented. These studies give interesting insight to the expected performance of the TRT in future high luminosity LHC proton-proton runs. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a transition radiation detector for cosmic rays

Transition radiation detectors consisting of sandwiches of plastic foam radiators and multiwire proportional chambers can be used to identify cosmic ray particles with energies gamma ? E/mc-squared is greater than 10 to the 3rd and to measure their energy in the region gamma is roughly equal to 10 to the 3rd

Hartmann, G.↗

Transition radiation generated by a particle passing through the apex of a conducting cone

The spatial field distribution is determined for the transition radiation generated by a particle passing through the apex of a cone along its axis. Expressions for the angular distribution of the radiation intensity are obtained for apex angles between 0 and {pi}. Characteristics of transition radiation emitted into a 'funnel' and a dihedral angle are compared.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reversed Cherenkov-Transition Radiation by a Charge Crossing a Left-Handed Medium Boundary

We analyze the radiation from a charged particle crossing the boundary between an ordinary medium and a 'left-handed' metamaterial. We obtain exact and approximate expressions for the field components and develop algorithms for their computation. The spatial radiation in this system can be separated into three distinct components, corresponding to ordinary transition radiation having a relatively large magnitude, Cherenkov radiation, and reversed Cherenkov-transition radiation (RCTR). The last one is explained by reflection and refraction of reversed Cherenkov radiation at the interface. Conditions for generating of RCTR are obtained. We note properties of this radiation that have potential applications in the detection of charged particles and accelerator beams and for the characterization of metamaterial macroscopic parameters (epsilon, mu).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The ALICE Transition Radiation Detector: Construction, operation, and performance

The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this article, the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.

43 PARTICLE ACCELERATORS↗

Image formation by incoherent and coherent transition radiation from flat and rough surfaces

In this paper we derive equations for the image formation of transverse profile of a relativistic beam obtained by means of optical transition radiation (OTR) from flat and rough metal surfaces. The motivation behind this study lies in the desire to suppress coherent transition radiation (COTR) observed in experiments at modern free electron lasers. The physical mechanism behind the problem of COTR is that the OTR is predominantly radiated at small angles of order of 1/$\gamma$ where $\gamma$ is the relativistic factor of the beam. This means that the transverse formation size of the image is of order of $\bar\lambda$$\gamma$ where $\bar\lambda$ = $\lambda$/2$\pi$ with $\lambda$ the radiation wavelength. For relativistic beams this can be comparable or even exceed the transverse size of the beam, which would mean that the image of the beam has very little to do with its transverse profile. It is fortuitous, however, that the incoherent image is formed by adding radiation energy of electrons and results in the transverse formation size being of order of $\bar\lambda$/$\theta_a$, with $\theta_a$ is the aperture angle of the optical system. The COTR image, in contrast, is formed by adding electromagnetic field of electrons, and leads to the formation size $\bar\lambda$$\gamma$. In situations when the COTR intensity exceeds that of OTR the COTR imaging makes the diagnostic incapable of measuring the beam profile.

99 GENERAL AND MISCELLANEOUS↗