Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TRANSITION BOILING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

In-cylinder spray evolution in a motored central-injection gasoline engine: Imaging and simulating the effects of flash-boiling and intake crossflow

Accurate predictions of fuel spray behavior and mixture formation in simulations of direct-injection spark-ignition (DISI) engines are fundamental to ensure proper description of all subsequent processes including ignition, combustion, and emissions. In this work, the spray evolution in a single-cylinder optical DISI engine was studied experimentally and numerically with the goal of enabling predictive computational fluid dynamics (CFD) modeling of in-cylinder sprays. The authors explored a wide range of operating conditions characterized by several fuel injection temperatures and engine speeds, using a well-characterized nine-component gasoline surrogate known as PACE-20. The effect of flash boiling and intake crossflow on the spray is discussed, with a focus on evaluating the ability of the spray models to capture highly transient spray behavior. In the experiments, the fuel temperature was varied between 20°C and 80°C, allowing for non-flash- to flash-boiling transition to emerge with enhanced flashing intensity at the highest temperatures. Spray collapse resulted in vapor-rich regions, owing to the locally lower inertia of the fluid. Varying the engine speed from 650 to 1950 rpm promoted increasingly more turbulent in-cylinder crossflow which interacted with the spray during the injection event and resulted in enhanced spray dispersion. The CFD model was able to capture the spray morphology transition at different fuel temperatures and engine speeds adequately. Further, it is shown that the spray breakup model could capture the transitional spray behavior induced by flash boiling atomization and intake flow via proper initialization of the spray cone angle and calibration of the spray models’ constants.

33 ADVANCED PROPULSION SYSTEMS↗

Boiling Experiment Facility for Heat Transfer Studies in Microgravity

Pool boiling in microgravity is an area of both scientific and practical interest. By conducting tests in microgravity, it is possible to assess the effect of buoyancy on the overall boiling process and assess the relative magnitude of effects with regards to other "forces" and phenomena such as Marangoni forces, liquid momentum forces, and microlayer evaporation. The Boiling eXperiment Facility is now being built for the Microgravity Science Glovebox that will use normal perfluorohexane as a test fluid to extend the range of test conditions to include longer test durations and less liquid subcooling. Two experiments, the Microheater Array Boiling Experiment and the Nucleate Pool Boiling eXperiment will use the Boiling eXperiment Facility. The objectives of these studies are to determine the differences in local boiling heat transfer mechanisms in microgravity and normal gravity from nucleate boiling, through critical heat flux and into the transition boiling regime and to examine the bubble nucleation, growth, departure and coalescence processes. Custom-designed heaters will be utilized to achieve these objectives.

Delombard, Richard↗

Fundamental Boiling and RP-1 Freezing Experiments

The prestart thermal conditioning of the hardware in LOX (liquid oxygen) systems involve heat transfer between LOX and metal where boiling plays a large role. Information is easily found on nucleate boiling, maximum heat flux, minimum heat flux and film boiling for common fluids like water. After looking at these standard correlations it was felt more data was needed for the cool down side transition boiling for the LN2 and LOX. In particular interest is the film boiling values, the temperature at which transition begins and the slope as peak heat flux is approached. The ultimate goal is an array of boiling heat transfer coefficient as a function of surface temperature which can be used in the chilldown model of the feed system, engine and bleed system for X-34. The first experiment consisted of an actual MC-1 LOX Impeller which had been machined backwards, that was instrumented with 17 surface thermocouples and submerged in liquid nitrogen. The thermocouples were installed on metal thicknesses varying from the thin inducer to the thick hub.

Goode, Brian↗

Experimental investigation of power transient flow boiling

To advance the mechanistic understanding of power transients in flow boiling, experimental investigations are performed to capture the thermal response of four different kinds of cladding materials, including FeCrAls, to Fuchs reactivity initiated accident transients and linear ramp power transients. The transition boiling regime is phenomenologically reflected in power-transient flow boiling, which is different from steady-state boiling. In light of this, the critical heat flux that is usually featured with temperature overshooting does not indicate thermal safety margin of cladding materials as conservatively as the maximum heat flux, which is greater than critical heat flux in the power transient boiling curve. This is physically attributed to the thermal energy deposition on the cladding wall. In addition, the thermal energy released from the cladding wall results in different boiling heat transfer coefficient for the decreasing and increasing power stages respectively during the Fuchs power transient. The maximum heat flux difference gap, which appears due to changes in cladding materials and transient time scales, is appreciable under an intermediate heat convection regime. However, this difference gap is gradually weakened by the progressive increasing of mass flux and/or inlet subcooling due to the enhanced dominance of heat convection over heat conduction. Finally, the small difference gap of maximum heat flux is found to be insignificant under the weak heat convection because of power transient induced annular flow instability.

42 ENGINEERING↗

Asymmetric Wettability Directs Leidenfrost Droplets

Leidenfrost phenomena on nano- and microstructured surfaces are of great importance for increasing control over heat transfer in high power density systems utilizing boiling phenomena. They also provide an elegant means to direct droplet motion in a variety of recently emerging fluidic systems. Here, we report the fabrication and characterization of tilted nanopillar arrays (TNPAs) that exhibit directional Leidenfrost water droplets under dynamic conditions, namely on impact with Weber numbers 40 at T 325 C. The batch fabrication of the TNPAs was achieved by glancing-angle anisotropic reactive ion etching of a thermally dewet platinum mask, with mean pillar diameters of 100 nm and heights of 200-500 nm. In contrast to previously implemented macro- and microscopic Leidenfrost ratchets, our TNPAs induce no preferential directional movement of Leidenfrost droplets under conditions approaching steady-state film boiling, suggesting that the observed droplet directionality is not a result of asymmetric vapor flow. Using high-speed imaging, phase diagrams were constructed for the boiling behavior upon impact for droplets falling onto TNPAs, straight nanopillar arrays, and smooth silicon surfaces. The asymmetric impact and directional trajectory of droplets was exclusive to the TNPAs for impacts corresponding to the transition boiling regime, revealing that asymmetric wettability upon impact is the mechanism for the droplet directionality.

asymmetric rebound↗

Estimating surface temperature in forced convection nucleate boiling - A simplified method

A simplified expression to estimate surface temperatures in forced convection boiling was developed using a liquid nitrogen data base. Using the principal of corresponding states and the Kutateladze relation for maximum pool boiling heat flux, the expression was normalized for use with other fluids. The expression was applied also to neon and water. For the neon data base, the agreement was acceptable with the exclusion of one set suspected to be in the transition boiling regime. For the water data base at reduced pressure greater than 0.05 the agreement is generally good. At lower reduced pressures, the water data scatter and the calculated temperature becomes a function of flow rate.

Hendricks, R. C.↗

Design, Construction, and Qualification of a Microscale Heater Array for Use in Boiling Heat Transfer

Boiling heat transfer is an efficient means of heat transfer because a large amount of heat can be removed from a surface using a relatively small temperature difference between the surface and the bulk liquid. However, the mechanisms that govern boiling heat transfer are not well understood. Measurements of wall temperature and heat flux near the wall would add to the database of knowledge which is necessary to understand the mechanisms of nucleate boiling. A heater array has been developed which contains 96 heater elements within a 2.5 mm square area. The temperature of each heater element is held constant by an electronic control system similar to a hot-wire anemometer. The voltage that is being applied to each heater element can be measured and digitized using a high-speed A/D converter, and this digital information can be compiled into a series of heat-flux maps. Information for up to 10,000 heat flux maps can be obtained each second. The heater control system, the A/D system and the heater array construction are described in detail. Results are presented which show that this is an effective method of measuring the local heat flux during nucleate and transition boiling. Heat flux maps are obtained for pool boiling in FC-72 on a horizontal surface. Local heat flux variations are shown to be three to six times larger than variations in the spatially averaged heat flux.

Rule, T. D.↗

Bubble Dynamics, Two-Phase Flow, and Boiling Heat Transfer in Microgravity

This report contains two independent sections. Part one is titled "Terrestrial and Microgravity Pool Boiling Heat Transfer and Critical heat flux phenomenon in an acoustic standing wave." Terrestrial and microgravity pool boiling heat transfer experiments were performed in the presence of a standing acoustic wave from a platinum wire resistance heater using degassed FC-72 Fluorinert liquid. The sound wave was created by driving a half wavelength resonator at a frequency of 10.15 kHz. Microgravity conditions were created using the 2.1 second drop tower on the campus of Washington State University. Burnout of the heater wire, often encountered with heat flux controlled systems, was avoided by using a constant temperature controller to regulate the heater wire temperature. The amplitude of the acoustic standing wave was increased from 28 kPa to over 70 kPa and these pressure measurements were made using a hydrophone fabricated with a small piezoelectric ceramic. Cavitation incurred during experiments at higher acoustic amplitudes contributed to the vapor bubble dynamics and heat transfer. The heater wire was positioned at three different locations within the acoustic field: the acoustic node, antinode, and halfway between these locations. Complete boiling curves are presented to show how the applied acoustic field enhanced boiling heat transfer and increased critical heat flux in microgravity and terrestrial environments. Video images provide information on the interaction between the vapor bubbles and the acoustic field. Part two is titled, "Design and qualification of a microscale heater array for use in boiling heat transfer." This part is summarized herein. Boiling heat transfer is an efficient means of heat transfer because a large amount of heat can be removed from a surface using a relatively small temperature difference between the surface and the bulk liquid. However, the mechanisms that govern boiling heat transfer are not well understood. Measurements of wall temperature and heat flux near the wall would add to the database of knowledge which is necessary to understand the mechanisms of nucleate boiling. A heater array has been developed which contains 96 heater elements within a 2.5 mm square area. The temperature of each heater element is held constant by an electronic control system similar to a hot-wire anemometer. The voltage that is being applied to each heater element can be measured and digitized using a high-speed Analog to Digital (A/D) converter, and this digital information can be compiled into a series of heat-flux maps. Information for up to 10,000 heat flux maps can be obtained each second. The heater control system, the A/D system and the heater array construction are described in detail. Results are presented which show that this is an effective method of measuring the local heat flux during nucleate and transition boiling. Heat flux maps are obtained for pool boiling in FC-72 on a horizontal surface. Local heat flux variations are shown to be three to six times larger than variations in the spatially averaged heat flux.

Chung, Jacob N.↗

Recent Ground-based Test Results for the Closed Loop Two-Phase Flow Chilldown Test Module for Future Integration with the Flow Boiling and Condensation Experiment onboard International Space Station

Effective cryogenic fluid management is important to the success of future manned and unmanned NASA missions, and the transfer line chilldown process is recognized as a key technological challenge. To address this challenge, the Two-phase Flow and Thermal Management Lab (TFTML) at Case Western Reserve University is collaborating with NASA Glenn Research Center to develop, test and deploy a closed loop two-phase flow chilldown test section onboard the International Space Station to be integrated with the current Flow Boiling and Condensation Experiment (FBCE) module. The final results of this project will create the first chilldown process database under pure and sustained microgravity conditions and will significantly advance the understanding of the chilldown process for cryogenic fluid management. In the present work, the ground-based test results of the closed loop SS-316 chilldown test section in a horizontal configuration at varying inlet mass flow rates (3-40 g/s) and inlet liquid subcooling (5-35 0C) are presented. The working fluid is PF-5060 and the chilldown curves captured the entire quenching curve involving the different boiling regimes and temperature transition points viz., film boiling, Leidenfrost/re-wetting point, transition boiling, critical heat flux (CHF), nucleate boiling, onset of nucleate boiling (ONB) and single-phase liquid flow regions, when the test section is pre-heated to around 250 0C. The major findings of the present study are, (i) the bottom part of the test section sees a lower re-wetting temperature due to the horizontal flow configuration, (ii) the re-wetting temperatures are relatively unaffected by inlet liquid mass flow rates though the increase in mass flow rates reduce the chilldown time, and (iii) the re-wetting temperatures decrease with decrease in inlet liquid subcooling. Further, preliminary flow visualization studies in a transparent pyrex test section will also be presented to understand the intricate flow boiling regime transitions during the chilldown process.

ISS↗

A novel probe design to study wetting front kinematics during forced convective quenching

The kinematics of the wetting front, i.e., the loci of the boundary between stable vapor film and the presence of bubbles, during quenching operations largely determines the evolution of the microstructural and displacement fields which, in turn, control the properties of the quenched product. Thus, it is important to develop techniques that allow its precise characterization. To this end, a novel probe design (conical-end cylinder) was coupled with an experimental set-up that guarantees fully developed flow to study wetting front kinematics during forced convective quenching of AISI 304 stainless steel probes in water at 60 C, flowing at 0.20 and 0.60 m/s. Conventional probes (flat-end cylinder) were also quenched for comparison. The wetting front was not symmetric when flat-end cylindrical probes were quenched, even for fully developed flow and relatively low values of quenchant velocity. Computer simulation of the vorticity field near the probe base (considering an isothermal system at ambient temperature) showed that there is a significant vorticity gradient in that region which may favour the chaotic collapse of the vapor film. In contrast, a similar calculation did not show any noticeable vorticity gradient for the conical-end cylindrical probe even at high quenchant velocities. The conical-end cylindrical probe and a fully developed flow ensured that the vapor film collapsed uniformly around the probe due to the fact that the formation of the wetting front was concentrated, initially, at the probe tip. This condition permits a constant advance of the wetting front and a stable transition between boiling regimes, facilitating the study of the kinematics of the wetting front. For the experimental conditions studied the following parameters were derived: (1) wetting front velocity, (2) nucleate boiling length, (3) duration of the nucleate boiling stage and (4) width of the vapor film. The duration of the nucleate boiling stage could be estimated using existing equations, obtaining results that are comparable to the experimentally determined values. For the experimental conditions studied the different boiling regimes and its transitions could be precisely defined along the surface heat flux history curve during quenching, resulting in six different zones. (author)

42 ENGINEERING↗

Experimental Studies on the Effect of Inlet Liquid Subcooling on the Chilldown Characteristics of Stainless Steel Tubes

Understanding transfer line chilldown process under microgravity is important for the efficient transfer of cryogenic propellants in space fuel depots to facilitate future long duration space missions. The present work is part of the ongoing efforts to develop and test a two-phase flow chilldown test section to study the complete chilldown process under sustained microgravity conditions onboard the International Space Station. In this study, ground-based chilldown experiments are carried out on a 60 cm long SS-316 test section with PF-5060 as the working fluid. The complete chilldown curve was obtained including the film, transition and nucleate boiling regimes along with the temperature transition points. The effect of inlet liquid subcooling on the behavior of the chilldown curves are presented. Further, the chilldown and heat flux curves are analyzed to obtain re-wetting/Leidenfrost and onset of nucleate boiling temperature transition points as well as the critical heat flux values. The effect of inlet liquid subcooling on regime-specific heat flux and heat transfer coefficients are also examined.

CFD↗

Flow Boiling and Condensation Experiment: Flow Boiling in a Rectangular Channel with Subcooled Inlet Conditions in Microgravity

Two-phase thermal management subsystems that take advantage of both the sensible and latent heat of a working fluid can potentially yield significant enhancements in overall performance by adopting heat transfer processes that are based on phase transition like boiling and condensation. Performance of terrestrial two-phase flow systems may be predictable because the hydrodynamic and body forces are understood, however, in microgravity, which is predominant during planetary space travel, forces that are masked by the strong body force on Earth (gravitational or buoyancy force) reappear with different magnitude and influence. The need arose for a facility that provides for two-phase flow with phase transition testing in microgravity. The Flow Boiling and Condensation Experiment (FBCE) is a facility that was launched to the International Space Station in August of 2021 and is in operation since February of 2022. This facility enables investigators to perform two-phase flow and phase transition research in flow boiling and condensation. Along with the test module that is experiment specific, the FBCE system consists of the fluid, avionics, and software subsystems. Currently two test modules, namely, the Flow Boiling Module (FBM) and the Condensation Module for Heat Transfer (CM-HT) are available. A third module, the Transfer Line test Module (TL) is being developed. The fluid subsystem conditions and delivers the fluid at the desired thermodynamic state to the test module. It consists of two fluid modules and a heater module that are connected by flex hoses for fluid circulation and by data and electrical cables for control and data acquisition. Two avionics modules acquire pressure and temperature data from various sensors in the flow loop. For FBM, a high-speed camera is available to acquire images of the boiling process. Experiments are operated autonomously by software and are based on an Experiment Parameters Master Table (EPMT) that is uploaded to ISS and is executed by the FBCE flight software. This presentation briefly introduces the objectives of FBCE and provides a system description of the experiment onboard of the ISS/Fluid Integrated Rack (FIR). Results of the test campaign carried out using the FBM are presented. Specifically, microgravity flow boiling of n-perfluorohexane (test fluid) is discussed with subcooled inlet conditions in a single-side-heated rectangular channel of dimensions 114.6-mm heated length, 2.5-mm heated width, and 5.0-mm height. Key operating parameters investigated are mass velocity (199.90 – 3200.13 kg/m2s), inlet subcooling (0.10 – 45.76°C), and inlet pressure (113.30 – 164.29 kPa). Image sequences acquired via high-speed-video are shown to elucidate the interfacial flow physics. The effects of various parameters on flow boiling heat transfer in microgravity, from the onset of boiling to the critical heat flux are discussed. Heat transfer results are presented in terms of flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and parametric trends of local and averaged heat transfer coefficient, and the critical heat flux.

Two-phase flow and phase transition↗

Experimental investigation on the phenomena around the onset nucleate boiling during the impacting of a droplet on the hot surface

Onset of nucleate boiling of a droplet when impacted onto hot surface was investigated. Three kinds of surfaces, normal stainless steel (NSS), stainless steel with TiO{sub 2} coating (UVN), and stainless steel with TiO{sub 2} coating and radiated by ultraviolet ray were employed to examine the effect of wettability. The droplet size was 2.4 mm diameter, and dropped under different We number. The image is generated by high speed camera with the frame speed of 1000 fps. The boiling conditions are identified as natural convection, nucleate boiling, critical heat flux, transition, and film boiling. In the present report, the discussion will be focused on the beginning of nucleate boiling on the droplet. Nucleate boiling occurs when bubbles are generated. These bubbles are probably caused by nucleation on the impurities within the liquid rather than at nucleation sites on the heated surface because the bubbles appear to be in the bulk of the liquid instead of at the liquid-solid interface. In addition, the smaller the contact angle, the fastest the boiling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗