Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

TPC Test-stands: An Overview & Future Prospects

The DUNE near detector design in Phase II will include a magnetized high-pressure gaseous-argon TPC (HPgTPC) surrounded by a calorimeter, called ND-GAr. ND-GAr is designed to provide fine-grained tracking, and due to its low detection threshold, it will be able to constrain one of the least-understood uncertainties for oscillation analysis: nuclear effects in argon at the neutrino interaction vertex. This talk will provide an overview of and an outlook about the ongoing R&D efforts in the context of the existing test stands that are evaluating the various readout system options for DUNE ND-GAr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of MeV-Scale Gammas from Pion/Muon Nuclear Capture With the LArIAT Liquid Argon TPC

LArIAT (Liquid Argon In A Testbeam) is a LArTPC experiment at Fermilab which aims to understand and characterize interactions of neutrino final-state products with Argon. Tracks for pions and muons in LArTPCs are difficult to differentiate since both particles exhibit very similar ionization densities. We are exploring unique new particle discrimination capabilities for pions and muons by exploiting information from small, isolated ionization depositions, referred to as "blips", reconstructed near the endpoint of stopping tracks. These blips are formed by gammas emitted when an at-rest pion or muon captures on the argon nucleus. The relatively low beam energy provided by LArIAT makes it uniquely suited for performing this demonstration. In this talk, an overview of event candidate selection and reconstruct blips corresponding to our signal of interest, nuclear captures of pions and muons at rest inside LArIAT's TPC, and how we estimate and subtract backgrounds from these capture-at-rest blip signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Elimination LArTPC Simulation Uncertainty With Modifcations to TPC Wire Waveforms

This paper introduces a novel approach to reducing systematic uncertainties in LArTPC detector simulations, which arise from known detector effects that are challenging and computationally intensive to model. The proposed method involves modifying simulated waveforms based on observed discrepancies in ionization signals from the TPC between actual data and simulations. This approach reduces the sensitivity to detailed detector modeling and decreases the computational resources required for accurate simulations.

Mktchyan, Karen↗

Correction of the baseline fluctuations in the GEM-based ALICE TPC

To operate the ALICE Time Projection Chamber in continuous mode during the Run 3 and Run 4 data-taking periods of the Large Hadron Collider, the multi-wire proportional chamber-based readout was replaced with gas-electron multipliers. As expected, the detector performance is affected by the so-called common-mode effect, which leads to significant baseline fluctuations. A detailed study of the pulse shape with the new readout has revealed that it is also affected by ion tails. Since reconstruction and data compression are performed fully online, these effects must be corrected at the hardware level in the FPGA-based common readout units. The characteristics of the common-mode effect and of the ion tail, as well as the algorithms developed for their online correction, are described in this paper. The common-mode dependencies are studied using machine-learning techniques. Toy Monte Carlo simulations are performed to illustrate the importance of online corrections and to investigate the performance of the developed algorithms.

47 OTHER INSTRUMENTATION↗

Techniques for TPC Calibration: Application to Liquid Ar-TPCs

Large liquid argon TPCs are playing an increasingly important role in neutrino physics, and their calibration will be an essential component of their capability to reach the required performance and precision. Natural sources are extensively used but present limitations, since natural radioactivity from 39 Ar is of low energy, and the rate of cosmic ray muons is low when the detectors are placed deep underground. Argon gas TPCs have been calibrated with ionizing laser beams for several decades, and more recently the technique has been further developed for use in liquid TPCs. Other recent ideas include the use of external neutron generators creating pulses that propagate into the detector. This paper reviews the development of the laser and neutron methods for the calibration of argon TPCs and describes their planned implementation in the upcoming DUNE experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation light detection in the long-drift ProtoDUNE-DP liquid argon TPC

ProtoDUNE-DP is a 6 × 6 × 6m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the Neutrino Platform at CERN in 2019-2020 as a prototype of the DUNE Far Detector. DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. The light signal in these detectors is crucial to provide precise timing capabilities. In ProtoDUNE-DP, scintillation light produced by cosmic muons in the LArTPC is collected by the photomultiplier tubes (PMTs) placed up to 7 m away from the point of interaction. The scintillation light production and propagation processes are analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation light detection in the 6-m drift length ProtoDUNE Dual Phase liquid argon TPC

The Deep Underground Neutrino Experiment (DUNE) is a leading-edge experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE-Dual Phase (DP) is a 6 × 6 × 6 m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the CERN Neutrino Platform in 2019–2020 as a prototype of the DUNE far detector. In ProtoDUNE-DP, the scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, we present the performance of the ProtoDUNE-DP photon detection system, comparing different wavelength-shifting techniques and the use of xenon-doped LAr as a promising option for future large LArTPCs. The scintillation light production and propagation processes are analyzed and compared to simulations, improving understanding of the liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing the hit finding algorithm for liquid argon TPC neutrino detectors using parallel architectures

Neutrinos are particles that interact rarely, so identifying them requires large detectors which produce lots of data. Processing this data with the computing power available is becoming even more difficult as the detectors increase in size to reach their physics goals. Liquid argon time projection chamber (LArTPC) neutrino experiments are expected to grow in the next decade to have 100 times more wires than in currently operating experiments, and modernization of LArTPC reconstruction code, including parallelization both at data- and instruction-level, will help to mitigate this challenge. The LArTPC hit finding algorithm is used across multiple experiments through a common software framework. In this paper we discuss a parallel implementation of this algorithm. Using a standalone setup we find speedup factors of two times from vectorization and 30–100 times from multi-threading on Intel architectures. The new version has been incorporated back into the framework so that it can be used by experiments. On a serial execution, the integrated version is about 10 times faster than the previous one and, once parallelization is enabled, more speedups comparable to the standalone program are achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-scale real-time signal processing in physics experiments: the ALICE TPC FPGA pipeline

For LHC Run 3, the ALICE Time Projection Chamber was upgraded to operate in continuous readout mode. Interaction rates of up to 50 kHz in Pb-Pb collisions require real-time processing of more than 3 TB s -1 of raw detector data. This requirement is met by a custom FPGA-based processing pipeline that performs the complete front-end data treatment fully in-stream, including common-mode correction, pedestal subtraction, ion-tail filtering, zero suppression, and dense data packing. A central element of the design is a highly parallel common-mode correction algorithm operating directly on the streaming data. It robustly identifies signal-free readout channels on a time-bin basis and applies pad-dependent scaling to compensate for local variations in capacitive coupling in the GEM readout. In combination with pedestal subtraction and ion-tail filtering, this enables accurate baseline restoration under extreme high-occupancy conditions, preventing signal loss while efficiently suppressing noise prior to zero suppression. The pipeline operates continuously at the full detector bandwidth and reduces the raw input rate of approximately 3 TB s -1 to about 900 GBps for Pb-Pb collisions at the target interaction rate. Overall, it represents a large-scale FPGA-based real-time signal-processing implementation for high-energy physics detector readout.

Digital signal processing (DSP)↗

Almost medium-free measurement of the Hoyle state direct-decay component with a TPC

The structure of the Hoyle state, a highly α -clustered state at 7.65 MeV in 12 C, has long been the subject of debate. Understanding if the system comprises of three weakly interacting α particles in the 0s orbital, known as an α-condensate state, is possible by studying the decay branches of the Hoyle state. The direct decay of the Hoyle state into three α particles, rather than through the 8 Be ground state, can be identified by studying the energy partition of the three α particles arising from the decay. This paper provides details on the breakup mechanism of the Hoyle stating using a new experimental technique. Method: By using β-delayed charged-particle spectroscopy of 12 N using the Texas active target time-projection chamber, a high-sensitivity measurement of the direct 3α decay ratio can be performed without contributions from pileup events. A Bayesian approach to understanding the contribution of the direct components via a likelihood function shows that the direct component is <0.043% at the 95% confidence level. This value is in agreement with several other studies, and, here, we can demonstrate that a small nonsequential component with a decay fraction of about 10 –4 is most likely. Here, the measurement of the non-sequential component of the Hoyle state decay is performed in an almost medium-free reaction for the first time. The derived upper limit is in agreement with previous studies and demonstrates sensitivity to the absolute branching ratio. Further experimental studies would need to be combined with robust microscopic theoretical understanding of the decay dynamics to provide additional insight into the idea of the Hoyle state as an α condensate.

6 ≤ A ≤ 19↗

Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel

Dark matter lighter than 10 GeV / c 2 encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino fog for GeV-scale masses and significant sensitivity down to 10 MeV / c 2 considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector’s sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Data Compression for 3D Sparse TPC via Bicephalous Convolutional Autoencoder

Real-time data collection and analysis in large experimental facilities present a great challenge across multiple domains, including high energy physics, nuclear physics, and cosmology. To address this, machine learning (ML)-based methods for real-time data compression have drawn significant attention. However, unlike natural image data, such as CIFAR and ImageNet that are relatively small-sized and continuous, scientific data often come in as three-dimensional 3D data volumes at high rates with high sparsity (many zeros) and non-Gaussian value distribution. This makes direct application of popular ML compression methods, as well as conventional data compression methods, suboptimal. To address these obstacles, this work introduces a dual-head autoencoder to resolve sparsity and regression simultaneously, called Bicephalous Convolutional AutoEncoder (BCAE). This method shows advantages both in compression fidelity and ratio compared to traditional data compression methods, such as MGARD, SZ, and ZFP. To achieve similar fidelity, the best performer among the traditional methods can reach only half the compression ratio of BCAE. Moreover, a thorough ablation study of the BCAE method shows that a dedicated segmentation decoder improves the reconstruction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation

We investigate the performance of Opticks, a NVIDIA OptiX API 7.5 GPU-accelerated photon propagation tool compared with a single-threaded Geant4 simulation. We compare the simulations using an improved model of the NEXT-CRAB-0 gaseous time projection chamber. Performance results suggest that Opticks improves simulation speeds by between 58.47 ± 0.02 and 181.39 ± 0.28 times relative to a CPU-only Geant4 simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between Opticks and Geant4.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Including 238 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f) NIFFTE fission TPC Cross-sections into the Neutron Data Standards Database

The primary purpose of this report is to document how the 238 U/ 235 U and 239 Pu/ 235 U neutron induced fission cross-section ratios, 238 U(n,f)/ 235 U(n,f) and 239 Pu(n,f)/ 235 U(n,f), respectively, measured by the NIFFTE fission Time Projection Chamber (fissionTPC) were included in the most recent database (termed GMA) underlying Neutron Data Standards (NDS) evaluations. This report shows and discusses NDS input files, and underlying assumptions regarding the uncertainty estimate and necessary for including these data. This uncertainty estimate and the resulting files were based on information provided by fissionTPC experimentalists, R.J.Casperson, N.S. Bowden, L. Snyder and K.T. Schmitt for the 238 U ratio, and by L. Snyder for the 239 Pu ratio. The fissionTPC data were included twice, by D. Neudecker and V. Pronyaev, to counter-check results and exclude possible mistakes in their inclusion. It is shown in both evaluations that including fissionTPC 239 Pu(n,f)/ 235 U(n,f) data points to a lower evaluated 239 Pu(n,f) cross section above 10 MeV than the currently released NDS data. This raises the question whether a part of a previous dataset by Tovesson et al., that was previously rejected above 13 MeV for having low values, should be included in the NDS evaluation after all. The evaluated 238 U(n,f) cross section only changes significantly close to the threshold. The impact on the 235 U(n,f) cross section is minimal. fissionTPC data reduce evaluated uncertainties on both observables by 0–12% of the GMA evaluated uncertainties. However, the currently released NDS data contain in addition to these GMA evaluated uncertainties “Unrecognized Sources of Uncertainties” (USU) of 1.2%. It needs to be further discussed within the NDS project, whether the new fissionTPC data should also reduce USU.

238U(n,f)/235U(n,f)↗