Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THROMBIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CT-Guided Thrombin Injection to Control Rapid Expansion of Ascending Aortic False Aneurysm 15 Months After Bentall-Bono Operation

We report a case of 57-year-old man treated emergently with CT-guided local thrombin injection as the first, life-saving step for control rapid expansion of the aortic pseudoaneurysm. Fifteen months earlier, he was operated on for ascending aortic true aneurysm and coronary artery disease. Upon admission, he had an anterior thoracic wall pulsatile tumor. Due to critical status, definite surgery was postponed and thrombin was injected close to the origin of pseudoaneurysm. It controlled successfully, bleeding from the ascending aorta and enabled the patient to survive the acute phase.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A sensitive HIV-1 envelope induced fusion assay identifies fusion enhancement of thrombin

To evaluate the interaction between HIV-1 envelope glycoprotein (Env) and target cell receptors, various cell-cell-fusion assays have been developed. In the present study, we established a novel fusion system. In this system, the expression of the sensitive reporter gene, firefly luciferase (FL) gene, in the target cells was used to evaluate cell fusion event. Simultaneously, constitutively expressed Renilla luciferase (RL) gene was used to monitor effector cell number and viability. FL gave a wider dynamic range than other known reporters and the introduction of RL made the assay accurate and reproducible. This system is especially beneficial for investigation of potential entry-influencing agents, for its power of ruling out the false inhibition or enhancement caused by the artificial cell-number variation. As a case study, we applied this fusion system to observe the effect of a serine protease, thrombin, on HIV Env-mediated cell-cell fusion and have found the fusion enhancement activity of thrombin over two R5-tropic HIV strains.

60 APPLIED LIFE SCIENCES↗

Rapid kinetics of changes in oxygen consumption rate in thrombin-stimulated platelets measured by high-resolution respirometry

Highlights: • High resolution respirometry can be used to investigate the rapid kinetics of changes in platelet oxygen consumption rate. • Thrombin triggers a rapid, transient increase in platelet oxygen consumption rate. • Aspirin and oligomycin partially inhibit the increased oxygen consumption rate. Platelet activation plays a key role in normal haemostasis and pathological thrombosis. Platelet activation is rapid; within minutes of stimulation, platelets generate bioactive phospholipids, secrete their granule contents, activate integrins and aggregate together to form a haemostatic plug. These events are dependent on ATP synthesis. Mitochondrial function in platelets from healthy volunteers and patients with a range of diseases indicate an important role for oxygen consumption in oxidative phosphorylation in normal and pathological function. Platelets also consume oxygen during oxidation reactions, such as cyclooxygenase-dependent thromboxane A{sub 2} synthesis. In this study, we used high-resolution respirometry to investigate rapid changes in oxygen consumption during platelet activation. We demonstrated a rapid, transient increase in oxygen consumption rate within minutes of platelet stimulation by the physiological activator, thrombin. This was partly inhibited by aspirin and by oligomycin. This shows that high resolution respirometry can provide information regarding rapid and dynamic changes in oxygen consumption during platelet activation.

60 APPLIED LIFE SCIENCES↗

Mechanism of the Anticoagulant Activity of Thrombin Mutant W215A/E217A

The thrombin mutant W215A/E217A (WE) is a potent anticoagulant both in vitro and in vivo. Previous x-ray structural studies have shown that WE assumes a partially collapsed conformation that is similar to the inactive E* form, which explains its drastically reduced activity toward substrate. Whether this collapsed conformation is genuine, rather than the result of crystal packing or the mutation introduced in the critical 215-217 {beta}-strand, and whether binding of thrombomodulin to exosite I can allosterically shift the E* form to the active E form to restore activity toward protein C are issues of considerable mechanistic importance to improve the design of an anticoagulant thrombin mutant for therapeutic applications. Here we present four crystal structures of WE in the human and murine forms that confirm the collapsed conformation reported previously under different experimental conditions and crystal packing. We also present structures of human and murine WE bound to exosite I with a fragment of the platelet receptor PAR1, which is unable to shift WE to the E form. These structural findings, along with kinetic and calorimetry data, indicate that WE is strongly stabilized in the E* form and explain why binding of ligands to exosite I has only a modest effect on the E*-E equilibrium for this mutant. The E* {yields} E transition requires the combined binding of thrombomodulin and protein C and restores activity of the mutant WE in the anticoagulant pathway.

36 MATERIALS SCIENCE↗

Effect of wavelength and filter set choices on fluorogenic thrombin generation assay: Considerations for interlaboratory differences

Insufficient agreement between results of various in–house and commercial thrombin generation (TG) assays complicates TG adoption and use. can be caused by different assay variables, for example, volumes and concentrations of reagents. Although most modern assays employ the same fluorogenic thrombin substrate Z–Gly–Gly–Arg 7–amino–4–methylcoumarin (ZGGR–AMC), the excitation (Ex) and emission (Em) wavelengths used for fluorescence signal measurements can be different.

60 APPLIED LIFE SCIENCES↗

Percutaneous Thrombin Injection of a Femoral Artery Pseudoaneurysm with Simultaneous Venous Balloon Occlusion of a Communicating Arteriovenous Fistula

An 82-year-old woman developed acute occlusion of her right coronary artery. She underwent percutaneous coronary stent placement and aortic balloon pump installation. In the postprocedural period, she developed a common femoral artery pseudoaneurysm (PSA) that communicated with the common femoral vein via an arteriovenous fistula (AVF). After unsuccessful ultrasound-guided compression, ultrasound-guided thrombin injection of the PSA was performed, with simultaneous balloon occlusion of the common femoral vein at the level of the AVF. There was complete thrombosis of the PSA and AVF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Thrombin Injection Secured with an Embolic Protection Device as a Treatment for a Superior Mesenteric Artery Pseudoaneurysm

A pseudoaneurysm of the superior mesenteric artery (SMA) is a rare and life-threatening condition of various etiology. Even unruptured it can cause severe health problems or death. We report a 71-year-old male with a SMA pseudoaneurysm who was successfully treated with a transarterial thrombin injection secured with an embolic protection device used in carotid angioplasty. To our knowledge, this is the first case of a SMA pseudoaneurysm treated by this method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thrombin Injection Failure with Subsequent Successful Stent-Graft Placement for the Treatment of an Extracranial Internal Carotid Pseudoaneurysm in a 5-Year-Old Child

Internal carotid artery pseudoaneurysm is a rare life-threatening condition that may develop in different clinical situations. We report the case of an extracranial internal carotid artery pseudoaneurysm secondary to a throat infection in a pediatric patient that was initially treated with percutaneous thrombin injection under ultrasound guidance. However, recanalization occurred at 48 h, and definitive treatment was then performed by endovascular stent-graft placement. We briefly review the clinical characteristics of this uncommon clinical condition as well as the treatment options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design of a thrombin resistant human acidic fibroblast growth factor (hFGF1) variant that exhibits enhanced cell proliferation activity

Acidic fibroblast growth factors (FGF1s) are heparin binding proteins that regulate a wide array of key cellular processes and are also candidates for promising biomedical applications. FGF1-based therapeutic applications are currently limited due to their inherent thermal instability and susceptibility to proteases. Using a wide range of biophysical and biochemical techniques, we demonstrate that reversal of charge on a well-conserved positively charged amino acid, R136, in the heparin binding pocket drastically increases the resistance to proteases, thermal stability, and cell proliferation activity of the human acidic fibroblast growth factor (hFGF1). Two-dimensional NMR data suggest that the single point mutations at position-136 (R136G, R136L, R136Q, R136K, and R136E) did not perturb the backbone folding of hFGF1. Results of the differential scanning calorimetry experiments show that of all the designed R136 mutations only the charge reversal mutation, R136E, significantly increases (ΔT m = 7 °C) the thermal stability of the protein. Limited trypsin and thrombin digestion results reveal that the R136E mutation drastically increases the resistance of hFGF1 to the action of the serine proteases. Isothermal titration calorimetry data show that the R136E mutation markedly decreases the heparin binding affinity of hFGF1. Interestingly, despite lower heparin binding affinity, the cell proliferation activity of the R136E variant is more than double of that exhibited by either the wild type or the other R136 variants. The R136E variant due to its increased thermal stability, resistance to proteases, and enhanced cell proliferation activity are expected to provide valuable clues for the development of hFGF1- based therapeutics for the management of chronic diabetic wounds.

59 BASIC BIOLOGICAL SCIENCES↗

Loop Electrostatics Asymmetry Modulates the Preexisting Conformational Equilibrium in Thrombin

Thrombin exists as an ensemble of active (E) and inactive (E*) conformations that differ in their accessibility to the active site. Here we show that redistribution of the E*–E equilibrium can be achieved by perturbing the electrostatic properties of the enzyme. Removal of the negative charge of the catalytic Asp102 or Asp189 in the primary specificity site destabilizes the E form and causes a shift in the 215–217 segment that compromises substrate entrance. Solution studies and existing structures of D102N document stabilization of the E* form. A new high-resolution structure of D189A also reveals the mutant in the collapsed E* form. Furthermore, these findings establish a new paradigm for the control of the E*–E equilibrium in the trypsin fold.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗