Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOSTATS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A stochastic thermostat algorithm for coarse-grained thermomechanical modeling of large-scale soft matters: Theory and application to microfilaments

As all-atom molecular dynamics method is limited by its enormous computational cost, various coarse-grained strategies have been developed to extend the length scale of soft matters in the modeling of mechanical behaviors. However, the classical thermostat algorithm in highly coarse-grained molecular dynamics method would underestimate the thermodynamic behaviors of soft matters (e.g. microfilaments in cells), which can weaken the ability of materials to overcome local energy traps in granular modeling. Based on all-atom molecular dynamics modeling of microfilament fragments (G-actin clusters), a new stochastic thermostat algorithm is developed to retain the representation of thermodynamic properties of microfilaments at extra coarse-grained level. The accuracy of this stochastic thermostat algorithm is validated by all-atom MD simulation. This new stochastic thermostat algorithm provides an efficient way to investigate the thermomechanical properties of large-scale soft matters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Making Energy Savings Easier: Usability Metrics for Thermostats

U.S. residential thermostats control approximately 9% of the nation’s energy use. Many building codes now require programmable thermostats (PTs) because of their assumed energy savings. However, several recent field studies have shown no significant savings or even higher energy use in households using PTs compared to those using non-PTs. These studies point to usability problems that lead to incorrect use and wasted energy. However, the lack of clear, consistent metrics has hampered the acceptance of usability concerns by thermostat manufacturers. Thus there is a need for metrics specific to PTs that manufacturers can use to evaluate their products. Here, we report on the results of a usability study conducted on five commercially available PTs and the development of four new metrics suitable for use in evaluating thermostat usability. Our study confirmed usability deficits in the current generation of PTs and showed the metrics are correlated with each other as well as agreeing with the qualitative results of the study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Passive Radiative “Thermostat” Enabled by Phase-Change Photonic Nanostructures

A thermostat senses the temperature of a physical system and switches heating or cooling devices on or off, regulating the flow of heat to maintain the system’s temperature near a desired set point. Taking advantage of recent advances in radiative heat transfer technologies, here we propose a passive radiative “thermostat” based on phase-change photonic nanostructures for thermal regulation at room temperature. By self-adjusting their visible to mid-IR absorptivity and emissivity responses depending on the ambient temperature, the proposed devices use the sky to passively cool or heat during day-time using the phase-change transition temperature as the set point, while at night-time temperature is maintained at or below ambient. We simulate the performance of a passive nanophotonic thermostat design based on vanadium dioxide thin films, showing daytime passive cooling (heating) with respect to ambient in hot (cold) days, maintaining an equilibrium temperature approximately locked within the phase transition region. Furthermore, passive radiative thermostats can potentially enable novel thermal management technologies, for example, to moderate diurnal temperature in regions with extreme annual thermal swings.

47 OTHER INSTRUMENTATION↗

Two-dimensional chaotic thermostat and behavior of a thermalized charge in a weak magnetic field

A two-dimensional version of a chaotic thermostat is investigated. Its structure follows the concept previously introduced by the author [G. J. Morales, Phys. Rev. E 97, 032203 (2018)] to generate a one-dimensional chaotic thermostat, namely, the usual friction force of a deterministic thermostat is supplemented with a self-consistent fluctuating force that depends on the drag coefficient associated with coupling to the heat bath. Azimuthal symmetry requires the thermostat to have two internal degrees of freedom, thus the Martyna-Klein-Tuckerman [G. J. Martyna et al., J. Chem. Phys. 97, 2635 (1992)] model is chosen for the heat bath. The unmagnetized system exhibits two-dimensional diffusive behavior, achieves symmetric Maxwellian velocity distributions in the absence of an external potential, and satisfies the Einstein relation when an external force is applied. The velocity fluctuations display the characteristic exponential frequency spectrum associated with chaotic systems. The model is used to explore the diffusive motion of a thermalized charge in a weak magnetic field and the associated Hall and Pedersen mobilities. Over a range of magnetic field strengths the charge exhibits absolute negative mobility.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beyond Control: Enabling Smart Thermostats for Leakage Detection

Smart thermostats, with multiple sensory abilities, are becoming pervasive and ubiquitous, in both residential and commercial buildings. By analyzing occupants’ behavior, adjusting set temperature automatically, and adapting to temporal and spatial changes in the atmosphere, smart thermostats can maximize both - energy savings and user comfort. In this paper, we study smart thermostats for refrigerant leakage detection. Retail outlets, such as milk-booths and quick service restaurants set up cold-rooms to store perishable items. In each room, a refrigeration unit (akin to air-conditioners) is used to maintain a suitable temperature for the stored products. Often, refrigerant leaks through the coils (or valves) of the refrigeration unit which slowly diminishes the cooling capacity of the refrigeration unit while allowing it to be functional. Such leaks waste significant energy, risk occupants’ health, and impact the quality of stored perishable products. While store managers usually fail to sense the early symptoms of such leaks, current techniques to report refrigerant leakage are often not scalable. We propose Greina - to continuously monitor the readily available ambient information from the thermostat and timely report such leaks. We evaluate our approach on 74 outlets of a retail enterprise and results indicate that Greina can report the leakage a week in advance when compared to manual reporting

Jain, Milan↗

Transactive control of fast-acting demand response based on thermostatic loads in real-time retail electricity markets

Coordinated operation of distributed thermostatic loads such as heat pumps and air conditioners can reduce energy costs and prevents grid congestion, while maintaining room temperatures in the comfort range set by consumers. This paper furthers efforts towards enabling thermostatically controlled loads (TCLs) to participate in real-time retail electricity markets under a transactive control paradigm. An agent-based approach is used to develop an effective and low complexity demand response control scheme for TCLs. The proposed scheme adjusts aggregated thermostatic loads according to real-time grid conditions under both heating and cooling modes. Here, a case study is presented showing the method reduces consumer electricity costs by over 10% compared to uncoordinated operation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A method to generate heating and cooling schedules based on data from connected thermostats

Internet-connected thermostats are a promising new source of temperature and operational data in homes because they record inside temperatures, setpoints, and HVAC runtimes every five minutes. Over 20 million Internet-connected thermostats have already been installed in American homes. Data from about 20,000 connected thermostats were collected and organized by climate zone, number of occupants, floor area, and day type. A method was developed to create up to 40 representative temperature schedules which, together, can more accurately capture the diversity of heating and cooling behaviors. These results are suitable for input into schedules for building energy simulation models. This information enables more realistic simulations of American heating and cooling behavior, leading to more accurate estimates of energy consumption and savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding and lighting control for load shedding measures to reduce the HVAC and lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 3%-10% daily peak demand reduction performance for applicable buildings, and 0.97% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding + Photovoltaics With 40% Rooftop Coverage

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding, lighting control for load shedding, and PV with 40% rooftop coverage measures to reduce the net building load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand, while applying the fixed rooftop PV application for onsite electricity generation. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 5%-15% daily peak demand reduction performance for applicable buildings, and around 1% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

14 SOLAR ENERGY↗

Using data from connected thermostats to track large power outages in the United States

The detection of power outages is an essential activity for electric utilities. A large, national dataset of Internet-connected thermostats was used to explore and illustrate the ability of Internet-connected devices to geospatially track outages caused by hurricanes and other major weather events. The method was applied to nine major outage events, including hurricanes and windstorms. In one event, Hurricane Irma, a network of about 1000 thermostats provided quantitatively similar results to detailed utility data with respect to the number of homes without power and identification of the most severely affected regions. The method generated regionally uniform outage data that would give emergency authorities additional visibility into the scope and magnitude of outages. The network of thermostat-sensors also made it possible to calculate a higher resolution version of outage duration (or SAIDI) at a level of customer-level visibility that was not previously available.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamical consequences of a constraint on the Langevin thermostat in molecular cluster simulation

We investigate some unusual behaviour observed while performing molecular dynamics simulations with the DL_POLY_4.03 code. Under the standard Langevin thermostat, atoms appear to be thermalised to different temperatures, depending on their mass and on the total number of particles in the system. We find that an imposed constraint whereby no thermal noise acts on the centre of mass of the system is the cause of the unexpected behaviour. This is demonstrated by solving the stochastic dynamics for the constrained thermostat and comparing the results with simulation data. The effect of the constraint can be considerable for small systems with disparate masses. By removing the constraint the Langevin thermostat may be restored to its intended behaviour and this has been implemented as an option in DL_POLY_4.05. SMK was supported by the U.S. Department of Energy, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences, and Biosciences.

dissociation↗

Local Communication in Populations of Thermostatically Controlled Loads

Thermostatically controlled loads (TCLs) have shown great potential for demand response (DR) in electric grid operations. However, it has been commonly seen that DR events using TCLs may cause load synchronization and unwanted oscillatory effects, especially in homogeneous populations. In an attempt to mitigate the negative impacts of DR events, a decentralized method is proposed that modifies each thermostat behavior based on the activity of a small number of nearby TCLs. This feedback introduces the possibility of instability in the aggregate behavior. A stability analysis is performed on a linearized model of the aggregate system and the results of that analysis compared to simulation results. The proposed modification of thermostat behavior results in fourfold reduction in the post-DR peak while suppressing ensuing oscillations at the expense of a modest increase in compressor cycling. Further, the linearized model also provides insight into the aggregate behavior of the population.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Poster Abstract: Leveraging Large Language Models to Reveal Interpretable Cooling Behaviors from Smart Thermostat Data

Frequent heatwaves and hot summers increasingly challenge occupant comfort, health, and energy grid stability. Addressing these challenges requires a detailed understanding of household cooling behaviors, such as thermostat adjustments and adaptive responses to extreme conditions. Traditional analyses often rely on aggregated numerical metrics that overlook subtle but important household-specific variations. In this study, we introduce a generalizable methodology that integrates large language models (LLMs) with vision capabilities to enable scalable and detailed analysis of residential thermostat data. Using Ecobee's Donate Your Data (DYD) dataset—which provides five-minute records of indoor temperatures, thermostat setpoints, and HVAC runtimes—we focus on two U.S. cities with contrasting summer climates : Austin (TX) and Phoenix (AZ). Because raw time-series data are not well suited for direct LLM analysis, we transform them into visual representations, such as daily indoor temperature trajectories and weekly runtime histograms, to better capture behavioral variations. Leveraging LLMs' visual interpretation, we extract descriptive behavioral features, including temperature preferences, time-of-day cooling orientation, anticipatory versus reactive heatwave responses, and behavioral consistency. These semantic features support unsupervised clustering to identify distinct occupant archetypes at scale, revealing differences—such as morning-centric anticipatory coolers versus households that shift toward warmer setpoints during heatwaves—that can inform demand response, resilience planning, and health-aware interventions. By converting raw numerical data into interpretable behavioral patterns, this methodology enables scalable and practical analysis of occupant behavior, supporting actionable insights for comfort, resilience, and energy management.

Nihar, Kopal↗

Energy-saving thermostat

Thermostat for two-stage heating system adjusts turn-on time and thermostat setpoint so that reserve resistance electrical heaters are not activated in morning warm up. Thermostat monitors outside temperature and turns on heat earlier in cold weather so that room will be at desired temperature by specified time. Mechanical, electrical, electronic, pneumatic, or microprocessor versions of device are possible. Correctional factors can be included where second-stage operation is more cost-effective than prolonged first-stage operation.

Jensen, R. N.↗

Impact analysis of personalized thermostat demand response

Demand response (DR) aims to curtail peak electric load to avoid running inefficient power plants, reduce costly transmission capacity increases, and improve grid reliability. One method of DR for residential settings involves the utility or third part remotely adjusting thermostat temperatures. Cooling setpoints may be increased 2°F – 6°F for hours, irrespective of occupant comfort. To maintain their comfort, occupants override these setpoint changes impacting the reliability of DR services provided to the grid. This paper presents a preliminary impact analysis of replacing the current DR approach of uniform thermostat setbacks for an entire population with personalized and context aware DR based on a dynamic model of occupant thermal comfort behavior. Over 151k interactions with ecobee thermostats are analyzed to predict the impact of such personalized DR on overrides, energy curtailment magnitude, and reliability.

Kane, Michael↗

Artificial Intelligence Thermostat to Detect Faults

Residential air conditioners and heat pumps often experience faults due to inadequate maintenance, which can severely reduce efficiency or even cause system failure. Common issues include dirty or clogged air filters and refrigerant leaks. These problems degrade performance and increase energy use and operating costs. This study presents a smart thermostat with embedded artificial intelligence to detect such faults and alert homeowners when maintenance is needed. The thermostat uses low-cost measurements—including return-air temperature, relative humidity, supply-air temperature, outdoor-air temperature, and condenser subcooling—to identify abnormal operations. Because different faults produce distinct response patterns, tailored algorithms are developed to recognize characteristic fault signatures. The investigation is built on a detailed co-simulation platform that couples EnergyPlus with the DOE/ORNL Heat Pump Design Model (HPDM). EnergyPlus represents the building’s dynamic environment, while HPDM is a high-fidelity, hardware-based model that can simulate fault-free performance as well as a wide range of faults, including gradual degradation such as minor refrigerant leakage. This platform provides a virtual training and testing environment that helps distinguish fault-induced behavior from normal operation and supports development of robust diagnostic algorithms. Using this framework, a Dynamic Bayesian Network was developed to identify two common faults—gradual refrigerant charge loss and indoor airflow blockage—and the AI-embedded thermostat was verified through annual building simulations.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗