Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TENDONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Tendon Driven Finger Actuation System

A humanoid robot includes a robotic hand having at least one finger. An actuation system for the robotic finger includes an actuator assembly which is supported by the robot and is spaced apart from the finger. A tendon extends from the actuator assembly to the at least one finger and ends in a tendon terminator. The actuator assembly is operable to actuate the tendon to move the tendon terminator and, thus, the finger.

Ihrke, Chris A.↗

Von Hippel-Lindau (VHL) protein antagonist, VH298, promotes functional activities of tendon-derived stem cells and accelerates healing of entheses in rats by inhibiting ubiquitination of hydroxy-HIF-1α

Enthesis is the region where a tendon attaches to a bone. It is a relatively vulnerable position, and in most cases surgical treatment is required upon rupture. The reconstructed enthesis is usually weaker compared to the original, and is prone to rupture again. Hypoxia-inducible factor-1 α (HIF-1α) is known to be involved in extensive activities in cells. It is inhibited under normoxic conditions, and undergoes two essential processes, hydroxylation and ubiquitination, the latter of which has been largely unexplored. Herein, we measured the levels of HIF-1α and hydroxy-HIF-1α in VH298-treated rat tendon-derived stem cells (TDSCs) by immunoblotting. We also detected the proliferation of TDSCs using CCK-8 assay and the mRNA levels of related genes by quantitative RT-PCR. The TDSCs were observed to be induced and the chondrogenic differentiation related genes were found to be enhanced. We also simulated in-vitro wounding in a scratch test and reconstructed the enthesis in a rat model of Achilles tendon by classical surgery followed by administration of phosphate buffer saline (PBS) injection or VH298 injection. We observed that HIF-1α and hydroxy-HIF-1α levels were increased in VH298-treated TDSCs in a dose- and time-dependent manner. Thirty micromolar VH298 could significantly increase cell proliferation, migration, and expression of collagen-1α, collagen-3α, decorin, tenomodulin, tenascin C genes, and chondrogenic differentiation-related genes, collagen-2α, SRY-box9, aggrecan. VH298-treated enthesis could tolerate more load-to-failure, had a better healing pattern, and activation of HIF signaling pathway. VH298 can thus enhance the functional activities of TDSCs, enhance their chondrogenic differentiation potential, and accelerate enthesis healing by inhibiting the ubiquitination of hydroxy-HIF-1α.

60 APPLIED LIFE SCIENCES↗

Extracellular vesicles of calcifying turkey leg tendon characterized by immunocytochemistry and high voltage electron microscopic tomography and 3-D graphic image reconstruction

To gain insight into the structure and possible function of extracellular vesicles in certain calcifying vertebrate tissues, normally mineralizing leg tendons from the domestic turkey, Meleagris gallopavo, have been studied in two separate investigations, one concerning the electron microscopic immunolocalization of the 66 kDa phosphoprotein, osteopontin, and the other detailing the organization and distribution of mineral crystals associated with the vesicles as determined by high voltage microscopic tomography and 3-D graphic image reconstruction. Immunolabeling shows that osteopontin is related to extracellular vesicles of the tendon in the sense that its initial presence appears coincident with the development of mineral associated with the vesicle loci. By high voltage electron microscopy and 3-D imaging techniques, mineral crystals are found to consist of small irregularly shaped particles somewhat randomly oriented throughout individual vesicles sites. Their appearance is different from that found for the mineral observed within calcifying tendon collagen, and their 3-D disposition is not regularly ordered. Possible spatial and temporal relationships of vesicles, osteopontin, mineral, and collagen are being examined further by these approaches.

NASA Discipline Musculoskeletal↗

Intramedullary Unicortical Button and All-Suture Anchors Provide Similar Maximum Strength for Onlay Distal Biceps Tendon Repair

To evaluate the biomechanical profile of onlay distal biceps repair with an intramedullary unicortical button versus all-suture anchors under cyclic loading and maximal load to failure. Twenty paired fresh-frozen human cadaveric elbows were randomized to onlay distal biceps repair with either a single intramedullary button or with two 1.35-mm all-suture anchors. A 1.3-mm high tensile strength tape was used in a Krackow stitch to suture the tendons in both groups. Specimens and repair constructs were loaded for 3,000 cycles and then loaded to failure. Maximum load to failure, mode of failure, and construct elongation were recorded. Mean (± standard deviation) maximum load to failure for the unicortical intramedullary button and all-suture anchor repairs were 503.23 ± 141.77 N and 537.33 ± 262.13 N (P = .696), respectively. Mean maximum displacement after 3,000 cycles (± standard deviation) was 4.17 ± 2.05 mm in the button group and 2.06 ± 1.05 mm in the suture anchor group (P = .014). Mode of failure in the button group was suture tape rupture in 7 specimens, failure at the tendon–suture interface in 2 specimens, and button pullout in 1 specimen. Anchor pullout was the mode of failure in all suture anchor specimens. There were no tendon ruptures or radial tuberosity fractures in either group. In conclusion, this study demonstrates that onlay distal biceps repair with 2 all-suture anchors has similar maximum strength to repair with an intramedullary button and that both are viable options for fixation.

60 APPLIED LIFE SCIENCES↗

Concept development of a tendon arm manipulator and anthropomorphic robotic hand

AMETEK/ORED inhouse research and development efforts leading toward a next-generation robotic manipulator arm and end-effector technology is summarized. Manipulator arm development has been directed toward a multiple-degree-of-freedom, flexible, tendon-driven concept referred to here as a Tendon Arm Manipulator (TAM). End-effector development has been directed toward a three-fingered, dextrous, tendon-driven, anthropomorphic configuration which is referred to as an Anthropomorphic Robotic Hand (ARH). Key technology issues are identified for both concepts.

Tolman, C. T.↗

Variability in Hoffmann and tendon reflexes in healthy male subjects

There is a time dependent decrease in amplitude of H- and T-reflexes during Zero-G exposure and subsequently an increase in the amplitude of the H-reflex 2-4 hours after return to a 1-G environment. These alterations have been attributed to the adaptation of the human neurosensory system to gravity. The Hoffman reflex (H-reflex) is an acknowledged method to determine the integrity of the monosynaptic reflex arc. However deep tendon reflexes (DTR's or T-reflexes), elicited by striking the tendon also utilize the entire reflex arc. The objective of this study was to compare the variability in latency and amplitude of the two reflexes in healthy subjects. Methods: Nine healthy male subjects, 27-43 years in age, 161-175 cm in height plus 60-86 Kg in weight, underwent weekly testing for four weeks with a Dan-Tec EMG counterpoint EMG system. Subjects were studied prone and surface EMG electrodes were placed on the right and left soleus muscles. The H-reflex was obtained by stimulating the tibial nerve in the politeal fossa with a 0.2 msec square wave pulse delivered at 2 Hz until the maximum H-reflex was obtained. The T-reflex was invoked by tapping the achilles tendon with a self triggering reflex hammer connected to the EMG system. The latencies and amplitudes for the H- and T-reflexes were measured. Results: These data indicate that the amplitudes of these reflexes varied considerably. However, latencies to invoked responses were consistent. The latency of the T-reflex was approximately 3-5 msec longer than the H-reflex. Conclusion: The T-reflex is easily obtained, requires less time, and is more comfortable to perform. Qualitative data can be obtained by deploying self triggering, force plated reflex hammers both in the 1-G and Zero-G environment.

Good, E.↗

Robust Operation of Tendon-Driven Robot Fingers Using Force and Position-Based Control Laws

A robotic system includes a tendon-driven finger and a control system. The system controls the finger via a force-based control law when a tension sensor is available, and via a position-based control law when a sensor is not available. Multiple tendons may each have a corresponding sensor. The system selectively injects a compliance value into the position-based control law when only some sensors are available. A control system includes a host machine and a non-transitory computer-readable medium having a control process, which is executed by the host machine to control the finger via the force- or position-based control law. A method for controlling the finger includes determining the availability of a tension sensor(s), and selectively controlling the finger, using the control system, via the force or position-based control law. The position control law allows the control system to resist disturbances while nominally maintaining the initial state of internal tendon tensions.

Abdallah, Muhammad E↗

Lower Robotic Arm Assembly Having a Plurality of Tendon Driven Digits

A lower robotic arm includes a base structure, a plurality of digits, and a plurality of tendons. The digits each include first, second, third, and fourth phalanges. Each digit is operatively attached to the base structure at the respective first phalange. A first joint operatively connects the first and second phalange to define a first axis, a second operatively connects the second and third phalange to define a second axis, and a third joint operatively connects the third and fourth phalange to define a third axis, such that the phalanges are selectively rotatable relative to the adjacent phalange, about the respective axis. The tendons are operatively connected to a respective one of the fourth phalanges. Each tendon selectively applies a first torque to the respective fourth phalange to urge the respective phalanges to rotate in a first direction about the respective axes.

Guo, Raymond↗

Tendon-Actuated Lightweight In-Space MANipulator (TALISMAN) Hinge Joint Structural Performance

The Tendon Actuated Lightweight In-Space MANipulator (TALISMAN), invented and initially developed under the Space Technology Mission Directorate Human Robotics Systems program, is a tendon-actuated robot that established a new structural architecture for long-reach space manipulators. The TALISMAN is designed to have significant stiffness and strength in the plane of the tendons or cables, and operations are designed such that all primary loads are applied in that same plane. However, during normal operations it is possible for out-of-plane forces to be applied on the TALISMAN when secondary loads are imparted by a tool or action at the wrist. These secondary loading conditions will induce out-of-plane bending loads in the TALISMAN hinge joints. The TALISMAN hinge joints must be designed for these out-of-plane loads, to ensure no failure of the joint occurs during operations. A series hinge joint out-of-plane stiffness tests were conducted at five different joint angles; at three cable pre-loads from 25-lbf to 100-lbf; up to an equivalent out-of-plane tip load of 27.28-lbf at the end of a 51-in. long distal link. The objective of the tests was to provide an initial set of deflection, cable load, and strain data to inform accurate modeling of the hinge joint out-of-plane stiffness. The test objective was achieved by developing an FEM of the hinge joint able to predict tip displacement to within 10% of values measured in tests. The hinge joint FEM may now be implemented into a full-scale analysis model of the TALISMAN V2.0 to provide predictions of out-of-plane displacement under different load and joint angle conditions.

Matthew K Mahlin↗

Matrix stiffness regulates the differentiation of tendon-derived stem cells through FAK-ERK1/2 activation

Highlights: • TDSC proliferation was enhanced with the increasing matrix stiffness. • More F-actin stress fibers formed in TDSCs while matrix stiffness increased. • Higher matrix stiffness inhibited the differentiation of TDSCs. • FAK or ERK1/2 activation was involved in the regulatory effect. Tendon derived stem cells (TDSCs) were vital in tendon homeostasis. Nevertheless, the regulation of TDSCs differentiation in tendinopathy is unclear. Matrix stiffness modulated stem cells differentiation, and matrix stiffness of tendinopathic tissues decreased significantly. In order to clarify the role of matrix stiffness in TDSCs differentiation, they were cultured on the gelatin hydrogels with the stiffness from 2.34 ± 1.48 kPa to 24.09 ± 14.03 kPa. The effect of matrix stiffness on TDSCs proliferation and differentiation were investigated with CCK8 assay, immunofluorescences, real time PCR and western blot. It was found the proliferation of TDSCs increased and more stress fibers formed with increasing matrix stiffness. The differentiation of TDSCs into tenogenic, chondrogenic, and osteogenic lineages were inhibited on stiff hydrogel evidenced by reduced expression of tenocyte markers THBS4, TNMD, SCX, chondrocyte marker COL2, and osteocyte markers Runx2, Osterix, and ALP. Furthermore, the phosphorylation of FAK and ERK1/2 were enhanced when TDSCs grew on stiff hydrogel. After FAK or ERK1/2 was inhibited, the effect of matrix stiffness on differentiation of TDSCs was inhibited as well. The above results indicated matrix stiffness modulated the proliferation and differentiation of TDSCs, and the regulation effect could correlate to the activation of FAK or ERK1/2.

60 APPLIED LIFE SCIENCES↗

Oriented hydroxyapatite in turkey tendon mineralized via the polymer-induced liquid-precursor (PILP) process

Bone is a hierarchically structured composite which imparts it with unique mechanical properties and bioresorptive potential. These properties are primarily influenced by the underlying nanostructure of bone, which consists of nanocrystals of hydroxyapatite embedded and uniaxially aligned within collagen fibrils. There is also a small fraction of non-collagenous proteins in bone, and these are thought to play an important role in bone's formation. In our in vitro model system of bone formation, polyanionic peptides are used to mimic the role of the non-collagenous proteins. In our prior studies, we have shown that intrafibrillar mineralization can be achieved in synthetic reconstituted collagen sponges using a polymer-induced liquid-precursor (PILP) mineralization process. This led to a nanostructured arrangement of hydroxyapatite crystals within the individual fibrils which closely mimics that of bone. This report demonstrates that biogenic collagen scaffolds obtained from turkey tendon, which consist of densely packed and oriented collagen fibrils, can also be mineralized by the PILP process. Synchrotron X-ray diffraction studies show that the mineralization process leads to a high degree of crystallographic orientation at the macroscale, thus emulating that found in the biological system of naturally mineralizing turkey tendon.

36 MATERIALS SCIENCE↗

Bi-fated tendon-to-bone attachment cells are regulated by shared enhancers and KLF transcription factors

The mechanical challenge of attaching elastic tendons to stiff bones is solved by the formation of a unique transitional tissue. Here, we show that murine tendon-to-bone attachment cells are bi-fated, activating a mixture of chondrocyte and tenocyte transcriptomes, under regulation of shared regulatory elements and Krüppel-like factors (KLFs) transcription factors. High-throughput bulk and single-cell RNA sequencing of humeral attachment cells revealed expression of hundreds of chondrogenic and tenogenic genes, which was validated by in situ hybridization and single-molecule ISH. ATAC sequencing showed that attachment cells share accessible intergenic chromatin areas with either tenocytes or chondrocytes. Epigenomic analysis revealed enhancer signatures for most of these regions. Transgenic mouse enhancer reporter assays verified the shared activity of some of these enhancers. Finally, integrative chromatin and motif analyses and transcriptomic data implicated KLFs as regulators of attachment cells. Indeed, blocking expression of both Klf2 and Klf4 in developing limb mesenchyme impaired their differentiation.

59 BASIC BIOLOGICAL SCIENCES↗

Morphological studies of bone and tendon

The Soviet biosatellite Cosmos 2044 carried adult rats on a spaceflight that lasted 13.8 days and was intended to repeat animal studies carrier out on Cosmos 1887. Skeletal tissue and tendon from animals flown on Cosmos 2044 were studied by light and electron microscopy, histochemistry, and morphometric techniques. Studies were confined to the bone cells and vasculature from the weight-bearing tibias. Results indicated that vascular changes at the periosteal and subperiosteal region of the tibia were not apparent by light microscopy or histochemistry. However, electron microscopy indicated that vascular influsions were present in bone samples from the flight animals. A unique combination of microscopy and histochemical techniques indicated that the endosteal osteoblasts from this same middiaphyseal region demonstrated a slight (but not statisticallly significant) reduction in bone cell activity. Electron-microscopic studies of the tendons from metatarsal bones showed a collagen fibril disorganization as a result of spaceflight. Thus changes described for Cosmos 1887 were present in Cosmos 2044, but the changes ascribed to spaceflight were not as evident.

Doty, Stephen B.↗

[Effects of Gravity on Attachment of Tendon to Bone]

We have received and processed all samples for either light or scanning electron microscopic analysis and have completed the histomorphometric analysis. We have characterized the changes caused by spaceflight to tendon attachments to the calcaneus, tibia, fibula and femur and compared them to hindlimbs and forelimbs from NIH.RZ. Soleus muscle histomorphometry has also been completed. Our results suggest severe osteoporosis in the femur, fibula and tibia of animals coincident to spaceflight, which had not resolved after 4-5 days following return to earth. This was evident at all sites, including sites of tendon attachments. This atrophy was not evident in the calcaneus. No muscle atrophy was evident. Comparison of scanning photomicrographs of flight animals with other lactating animals demonstrated structural similarities and suggested that it might be worthwhile to assess whether lactation is a factor in development of the osteoporosis in the spaceflight animals. In addition, evaluation of total calcium utilization by spaceflight animals would be beneficial.

Johnson, Roger B.↗

Improvements to the Tendon-Actuated Lightweight In-Space MANipulator (TALISMAN)

Devices for manipulating and precisely placing payloads are critical for efficient space operations including berthing of spacecraft, in-space assembly, construction and repair. Key to the success of many NASA space activities has been the availability of long-reach crane-like devices such as the Shuttle Remote Manipulation System (SRMS) and the Space Station Remote Manipulation System (SSRMS). These devices have been used for many operations including berthing visiting spacecraft to the International Space Station, deployment of spacecraft, space station assembly, astronaut positioning, payload transfer, and spacecraft inspection prior to atmospheric re-entry. Retiring the Space Transportation System has led to the removal of the SRMS from consideration for in-space missions, thus creating a capability gap. Recognizing this gap, work was initiated at NASA on a new architecture for long-reach space manipulators. Most current devices are constructed by joining revolute joints with carbon composite tubes, with the joints accounting for the majority of the device mass. For example in the case of the SRMS, the entire device mass is 410 kg (904 lbm); the joint structure, motors, gear train, cabling, etc., accounts for the majority of the system mass because the carbon composite tubes mass is 46 kg (101 lbm). An alternate space manipulator concept, the Tendon-Actuated Lightweight In-Space MANipulator (TALISMAN) was created to address deficiencies in the current state-of-the-art in long-reach manipulators. The antagonistic tendon actuated joint architecture allows the motors actuating the joint to be removed from the joint axis, which simplifies the joint design while simultaneously providing mechanical advantage for the motors. The improved mechanical advantage, in turn, reduces the size and power requirements for the motor and gear train. This paper will describe recent architectural improvements to the TALISMAN design that: 1) improve the operational robustness of the system by enabling maneuvers not originally possible by varying the TALISMAN geometry; 2) enable efficient active antagonistic control of a joint while sharing cable between antagonistic tension networks; and 3) uses a unique arrangement of differential capstans to reduce motor torque requirements by an order of magnitude. The paper will also summarize recent efforts to enable autonomous deployment of a TALISMAN including the deployment concept of operations and associated hardware system design. The deployment forces are provided by the same motor systems that are used for articulation, thus reducing the mass associated with the deployment system. The deployment approach is being tested on a TALISMAN prototype which is designed to provide the same operational performance as a shuttle-class manipulator. The prototype has been fabricated and is operational in a new facility at NASA Langley Research Center that has a large area (15.2 m by 21.3 m [50 ft by 70 ft]) air-bearing floor.

Doggett, William R.↗

Radial Artery Coursing Behind the Biceps Brachii Tendon: Significance for the Transradial Catheterization and a Clinically Oriented Classification of the Radial Artery Variations

In routine clinical practice the variations of the radial artery are the main reason for technical failure during transradial catheterization. If these variations are well documented, however, they do not represent a problem in the transradial approach. Therefore, we report here a rare case of the radial artery which is very strange but potentially valuable for the clinical practice: it arises at a right angle from the brachial artery and passes behind the biceps brachii tendon. Based on our findings and on an extensive literature review, we propose for the first time a clinically oriented classification of the variations of the radial artery. This classification is related to the catheterization success at the usual access site of the radial artery at the wrist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Engineering hybrid textile braids for tendon and ligament repair application

Abstract Challenges involving tendon and ligament repair have motivated the investigation of new strategies to improve clinical outcomes. These have been mainly based on polymer constructs, which may be non‐biodegradable or biodegradable. The former typically fails due to lack of device integration and the latter demands a complex balance between biodegradability and tissue ingrowth, often failing due to insufficient mechanical properties. This work presents the development of hybrid braids based on polyethylene terephthalate (PET) and polylactic acid (PLA) yarns. A textile technique was used to fabricate braids based on 16 multifilament yarns of varying PLA/PET composition. The composition was varied to maximize biodegradability while ensuring mechanical performance. The braids' morphology, physical and mechanical properties were characterized. As production parameters and architecture were maintained, the braids exhibited similar porosity and wicking ability. The breaking force and stiffness decreased significantly as the number of PLA yarns increased, although strain levels remained constant. Braids containing 10 and 12 PET yarns (out of the total 16 yarns) demonstrated good creep and force‐relaxation behavior, as well as resistance to cyclic loading. These compositions were selected for future work, to be assembled into more elaborate structures to mimic the fibrous organization and tensile properties of different tendons/ligaments.

Peixoto, Tânia↗

A Novel Anatomic Reconstruction for Posterior Tibialis Tendon in Treatment of Flexible Adult‐Acquired Flatfoot Deformity

Objective To present a novel approach for the anatomic reconstruction of the posterior tibialis tendon (PTT) in restoring plantar insertions and evaluate its efficiency in treating flexible adult‐acquired flatfoot deformity (AAFD) caused by PTT dysfunction. Methods For AAFD treatment, a novel PTT reconstruction method was presented. The current study involved 16 patients, including three men, and 13 women, from August 2017 to July 2019. The mean age was 43.2 ± 15.1 years (21–64 years). The innovative PTT repair method was used on all patients. The treatment involved performing a traditional Flexor Digitorum Longus (FDL) transfer in the navicular tuberosity and suturing the plantar insertions to FDL as tension was applied to tighten the plantar structures of the foot. The results were retrospectively analyzed. The clinical outcome was assessed using the pain visual analogue scale (VAS), the satisfaction VAS, and the American Orthopedic Foot and Ankle Society ankle–hindfoot scale (AOFAS‐AH). Isokinetic testing was performed using a dynamometer at 60°/s and 120°/s for inversion/eversion and plantarflexion/dorsiflexion, respectively, to determine the mean peak torque. Radiographic measurements were employed to assess the outcomes. Results Bone surgeries combined with the modified anatomic PTT reconstruction were performed on patients with medializing calcaneal osteotomy in 12 (75%) patients and subtalar joint fusion in four (25%) patients. The branch linking to the plantar insertions was detected in every case, with an average width of 3.5 ± 0.8 mm (3.1–4.3 mm). All patients were followed up for the mean of 16.8 ± 1.8 months (range, 15–20 months). The average postoperative functional scores, including pain VAS, satisfaction VAS, total AOFAS‐AH, and all AOFAS‐AH sub‐scales, steadily improved during the follow‐up. In the last follow‐up, isokinetic testing revealed no loss of plantarflexion strength ( p = 0.350 and 0.098) and significant improvement in the inversion strength ( p = 0.007 and 0.008) in the operated ankles at 60°/s and 120°/s. Radiographic outcomes, particularly the talar head uncovering, improved significantly after more than a year ( p < 0.001 for all). Conclusions The novel technique for PTT reconstruction in restoring the plantar insertions serves as an effective procedure in treating AAFD caused by PTT dysfunction in terms of delivering a consistent improvement in ankle inversion strength, medial longitudinal arch restoring, and satisfactory clinical outcomes.

Hu, Yong↗