Theory and Design of a Pneumatic Temperature Probe and Experimental Results Obtained in a High-temperature Gas Stream
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A probe is described that is capable of measuring gas temperatures exceeding 2000C
Reflection fiber temperature sensors functionalized with plasmonic nanocomposite material using intensity-based modulation are demonstrated for the first time. Characteristic temperature optical response of the reflective fiber sensor is experimentally tested using Au-incorporated nanocomposite thin films deposited on the fiber tip, and theoretically validated using a thin-film-optic-based optical waveguide model. By optimizing the Au concentration in a dielectric matrix, Au nanoparticles (NP) exhibit a localized surface plasmon resonance (LSPR) absorption band in a visible wavelength that shows a temperature sensitivity ~0.025%/°C as a result of electron–electron and electron–phonon scattering of Au NP and the surrounding matrix. Detailed optical material properties of the on-fiber sensor film are characterized using scanning electron microscopy (SEM) and focused-ion beam (FIB)-assisted transmission electron microscopy (TEM). Airy’s expression of transmission and reflection using complex optical constants of layered media is used to model the reflective optical waveguide. A low-cost wireless interrogator based on a photodiode transimpedance-amplifier (TIA) circuit with a low-pass filter is designed to integrate with the sensor. The converted analog voltage is wirelessly transmitted via 2.4 GHz Serial Peripheral Interface (SPI) protocols. Feasibility is demonstrated for portable, remotely interrogated next-generation fiber optic temperature sensors with future capability for monitoring additional parameters of interest.
Improved probe designed to be mounted at wingtip of airplane and used for measuring total temperature of air when airplane flies at high angles of attack. Four fins and swivel mount enable probe to align itself aerodynamically with local flow of air. Thus, stagnated-flow condition needed for accurate measurement of total temperature achieved.
Abstract Ferroelectric domain walls have emerged as one of the most fascinating objects in condensed matter physics due to the broad variability of functional behaviors they exhibit. However, the vast majority of domain walls studies have been focused on bias‐induced dynamics and transport behaviors. Here, the scanning probe microscopy approach based on piezoresponse force microscopy (PFM) with a dynamically heated probe, combining local heating and local biasing of the material is introduced. This approach is used to explore the thermal polarization dynamics in soft Sn 2 P 2 S 6 ferroelectrics, and allows for the exploration of phase transitions at individual domain walls. The strong and weak modulation regimes for the thermal PFM are introduced. The future potential applications of heated probe approach for functional SPM measurements including piezoelectric, elastic, microwave, and transport measurements are discussed.
Measurement techniques proposed by Gilbert and Lobdell (1953) and Rein and O'Laughlin (1967) are considered, giving attention to an apparent paradox. The criteria under which the assumptions made for the measurement techniques apply are specified. If sensors of different diameters are tested and the resultant plots of the parameter ?S' vs the wire temperature intersect below the abscissa, the considered measurement techniques are not applicable.
Not Available
Probe is sufficiently flexible so that it can be worn comfortably for long periods of time, but relatively rigid to permit easy insertion. Body and electrical leads of small thermistor are imbedded in flexible fluorosilicone matrix contained in vinyl plastic tubing.
Standardization by two general probe designs and determination of various correction factors for range of sizes in each design reduces requirements for individual calibration and associated costs.
Explore the source record for details and available documents.
Very-sensitive probe uses tungsten sensor wire wrapped around to notched electrodes. Design combines ruggedness of earlier but less sensitive probe using very-short sensor wire with very-sensitive but fragile version with sensor wires wrapped around non-conducting frames.
Aerodynamic probe is a small cylinder tube holding a network of tiny tubes leading to various ports. Six parameters are recorded simultaneously with little interference with aerodynamic flow. Two tubes connected by a hot-wire tungsten probe sense steady and fluctuating components of total and static pressures; the feedbacks from these tubes are input into differential-pressure sensors to measure fluctuating components of the pressures. Data are recorded by instruments at the back end of the probe.
A floating apparatus denoted a temperature probe aquatic suspension system (TPASS) has been developed for measuring the temperature of an ocean, lake, or other natural body of water at predetermined depths. Prior instruments built for the same purpose were found to give inaccurate readings because the apparatuses themselves significantly affected the temperatures of the water in their vicinities. The design of the TPASS is intended to satisfy a requirement to minimize the perturbation of the temperatures to be measured. The TPASS includes a square-cross-section aluminum rod 28 in. (=71 cm) long with floats attached at both ends. Each float includes five polystyrene foam disks about 3/4 in.(=1.9 cm) thick and 2.5 in. (=6.4 cm) in diameter. The disks are stacked to form cylinders, bolted to the rod, and covered with hollow plastic sleeves. A metal sleeve is clamped to the middle of the aluminum rod, from whence it hangs down into the water. Temperature probes (which can be thermocouples, thermistors, or resistance temperature devices) are placed within the sleeve at the desired measurement depths. Wires from the temperature probes are routed to the input terminals of a data logger.
A floating apparatus denoted a temperature probe aquatic suspension system (TPASS) has been developed for measuring the temperature of an ocean, lake, or other natural body of water at predetermined depths. Prior instruments built for the same purpose were found to give inaccurate readings because the apparatuses themselves significantly affected the temperatures of the water in their vicinities. The design of the TPASS is intended to satisfy a requirement to minimize the perturbation of the temperatures to be measured. The TPASS includes a square-cross-section aluminum rod 28 in. (approx. = 71 cm) long with floats attached at both ends. Each float includes five polystyrene foam disks about 3/4 in. (approx. = 1.9 cm) thick and 2.5 in. (approx. = 6.4 cm) in diameter. The disks are stacked to form cylinders, bolted to the rod, and covered with hollow plastic sleeves. A metal sleeve is clamped to the middle of the aluminum rod, from whence it hangs down into the water. Temperature probes (which can be thermocouples, thermistors, or resistance temperature devices) are placed within the sleeve at the desired measurement depths. Wires from the temperature probes are routed to the input terminals of a data logger. This work was done by Randy
Temperature, pressure and flow direction probe in rotating fluid machines analysis
Temperature-averaging thermal probe measures long-term temperature fluctuations in fluid environment. Consists of temperature probe embedded inside thermally massive material. Probe measurements used to estimate powerplant heating and cooling loads, map temperature profiles, and calibrate more-sensitive temperature probes.