Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TCR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

30 records · Page 2

Thin film molybdenum silicide as potential temperature sensors for turbine engines

Temperature measurements of Mo-Si-based thin-film resistance thermometers were studied. Annealing in an argon ambient at a temperature above 1000 C for at least 1 h is required to form the stable tetragonal MoSi2 phase. With a crack-free 2-micron-thick AlN barrier layer on top, a sensor was tested up to 1200 C. The resistivity vs temperature characteristic shows the room temperature resistivity and temperature coefficient of resistivity (TCR) of the sensor to be approximately 350 microohm and 0.01195 K, respectively. No film adhesion problems were observed for at least four testing cycles.

Ho, C. H.↗

Cellular responses to low-gravity: Pilot studies on suborbital rockets and orbiting spacecraft

The allocated funding supported, in part, experiments conducted on two Consort sounding rockets and five Shuttle flights. The primary parameters investigated were signal transduction in response to various mediators, cellular differentiation and metabolism in microgravity, and effect of microgravity on cytoskeletal morphology. Achievements include: demonstration of effect of spaceflight on the actin cytoskeleton in mouse osteoblasts and frog cells; confirmation that the T cell receptor-mediated signal transduction pathway in T lymphocytes is not affected by low-gravity compared to non-TCR-mediated stimulation (Con-A) which classically does not promote proliferative response; indication that microgravity may allow separation of proliferative signaling and secretory function in lymphocytes; demonstration that T lymphocytes and bone cells utilized less glucose indicating a shift in metabolism and confirming Spacelab results with WI-38 cells which used significantly less glucose, during spaceflight; confirmation that activation of human splenic B cells with a number of different mediators is not affected during spaceflight; demonstration of increased prostaglandin synthesis during reduced bone cell growth suggesting an effect of microgravity on prostaglandin-induced mitogenesis. The funding contributed significantly to the database described above and resulted in submission of six collaborative abstracts in 1993 (five to the ASGSB Annual Meeting and one to the ASCB Annual Meeting). Two abstracts were presented at the 1992 ASGSB Annual Meeting in Tucson. In addition, several peer reviewed papers are being generated and data will be included as background in preparation of future proposals, which hopefully will allow us to continue this type of extremely productive collaborative research.

Lewis, Marian L.↗

Overcoats for the Improved Performance of PdCr High Temperature Thin Film Strain Gages

Overcoat protection schemes for thin film devices have typically focused on inhibiting the growth of native oxides formed on the sensor surface, rather than on improving the passivating nature of these native oxides. Here, thin sputtered Cr overcoats and heat treatments in varying oxygen partial pressures enhanced the passivating nature of native Cr203 films formed on PdCr thin film strain gages. Results of strain tests using sensors protected using this approach are presented and the implications are discussed. PdCr gages with sputtered Cr overcoats withstood 12,000 dynamic strain cycles of 1100 micro-epsilon during 100 hours of testing at a temperature of 1000 C in air. Gage factors of 1.3 with drift rates as low as 0.1 Omega/hr were achieved for devices having a nominal resistance of approximately 100 Omega's. TCR's ranging from +550 ppm/C to +798 ppm/C were realized depending on the overcoat and thermal history. Possible mechanisms for an anomaly in the electrical characteristics of these films at 800 C and improvements in stability due to the use of overcoats are presented.

Gregory, Otto J.↗

Differences In Early T-Cell Signaling In Cultures Grown In a Rotating Clinostat vs. Static Controls

Altered gravity has previously been demonstrated to be a stress that can influence components of the immune system. Specifically, T-cell activation has been shown to be affected by changes in gravity, exhibiting a decrease in proliferative response to in vitro stimulation in microgravity. Subsequent ground based studies utilizing a rotating clinostat to model some of the effects of microgravity have been consistent with earlier flight based experiments. These ground and flight experiments have examined T-cell activation by measuring various responses including production of cytokines, DNA synthesis and the production of various cell surface activation markers. These indicators of T-cell activation were measured anywhere from 4 to 72 hours after stimulation. Prior to the work described here, the initial signaling events in T-cell activation had not been directly examined. The goal of this project was to determine how the process of early signal transduction was affected by growth in a rotating clinostat. Here we directly show a defect in signaling from TCR to MAPK in purified peripheral T-cells activated in the clinostat by OKT3/antiCD28 coated microbeads as compared to static controls.

Alexamder. M.↗

Effects of 2-deoxy-D-glucose administration on immune parameters in mice

Physical exercise and diet alterations have been shown to affect immune parameters. Similar effects are also induced by the administration of the non-metabolizable glucose analog, 2-deoxy-D-glucose (2-DG). The current study was designed to characterize the effects of glucoprivation induced by 2-DG administration on leukocyte subset distribution and function. BDF1 mice (n = 8 per group) were injected intraperitoneally one or three times with 0, 500, 750, 1000 or 1500 mg/kg of 2-DG. Two hours after the last injection of 2-DG, immunological parameters were analyzed. A dose-dependent increase in plasma glucose concentrations of mice injected once with up to 1500 mg/kg of 2-DG was observed (p < 0.001). After either one or three injections of up to 1500 mg/kg of 2-DG, corticosterone levels, leukocyte counts in the spleen, and CD3+ cells in the thymus increased. In vitro proliferation of partially purified lymphocytes from the spleen in the presence of both concanavalin-A and lipopolysaccharide decreased in a dose dependent manner (p < 0.05). In addition, after three injections, the proportion of both thymocytes and splenocytes bearing alphabeta-TCR increased as the concentration of 2-DG increased (p < 0.01). These results demonstrate that 2-DG administration induced dose-dependent changes in both thymus and spleen cell distribution and function.

NASA Discipline Regulatory Physiology↗

Miniature Instrumentation for SIPR (Subsurface Ice PRobe)

Ice coring has proved to be a valuable scientific tool for determining climate history on Earth. The goal of the SIPR project is to develop a simple extraterrestrial ice sampling method of comparable value to coring. The SIPR probe works by melting its way through glacial ice, pumping the melt water to the surface for analysis as it descends hundreds of meters. The specific geometry of the probe, along with size and power constraints, requires creative diagnostic instrumentation. A thin, vertically strung heated filament will provide continuous-level monitoring of water in down-hole containers. The filament has an appreciable temperature coefficient to resistance (TCR), so as water cools the wire, its resistance decreases. At a constant electrical current, the voltage across the filament varies linearly with water level.

Ostmo, Karl P.↗

Developing Multilayer Thin Film Strain Sensors With High Thermal Stability

A multilayer thin film strain sensor for large temperature range use is under development using a reactively-sputtered process. The sensor is capable of being fabricated in fine line widths utilizing the sacrificial-layer lift-off process that is used for micro-fabricated noble-metal sensors. Tantalum nitride films were optimized using reactive sputtering with an unbalanced magnetron source. A first approximation model of multilayer resistance and temperature coefficient of resistance was used to set the film thicknesses in the multilayer film sensor. Two multifunctional sensors were fabricated using multilayered films of tantalum nitride and palladium chromium, and tested for low temperature resistivity, TCR and strain response. The low temperature coefficient of resistance of the films will result in improved stability in thin film sensors for low to high temperature use.

Wrbanek, John D.↗

An Overview of the Hurricane Imaging Radiometer (HIRAD)

Accurate observations of ocean surface vector winds (OSVW) with high spatial and temporal resolution are critically important to improve both our understanding and predictability of tropical cyclones. As the successful NASA QuikSCAT satellite continues to age beyond its planned life span, many members of the tropical cyclone research and operational community recognize the need to develop new observational technologies and strategies to meet the essential need for OSVW information. This concern has been expressed in both the "Earth Science and Applications from Space: National Imperatives for the Next Decade and Beyond" developed by the National Research Council Committee on Earth Science and Applications from Space and the "Interagency Strategic Research Plan for Tropical Cyclone The Way Ahead" developed by the Joint Action Group for Tropical Cyclone Research (JAG-TCR) sponsored by the Office of the Federal Coordinator for Meteorology. One innovative technology development which offers the potential for new, unique remotely sensed observations of tropical cyclone OSVW and precipitation is the Hurricane Imaging Radiometer (HIRAD). This new instrument is passive microwave synthetic thinned aperture radiometer under development at the NASA Marshall Space Flight Center that will operate at the C-Band frequencies of 4, 5, 6, and 7 GHz. These frequencies have been successfully demonstrated by the NOAA nadir-staring Stepped Frequency Microwave Radiometer (SFMR) as useful for monitoring tropical cyclone ocean surface wind speeds and rain rates from low altitude reconnaissance aircraft. The HIRAD design incorporates a unique antenna design as well as several technologies that have been successfully demonstrated by the University of Michigan Lightweight Rain Radiometer sponsored by NASA Earth Science Technology Office Instrument Incubator Program. HIRAD will be a compact, lightweight, low-power instrument with no moving parts that will produce imagery of ocean wind surface wind parameters and rain rate during the strong wind and heavy rain hurricane conditions that hamper the observational capabilities of higher frequency passive microwave radiometers or scatterometers. It will also produce imagery of sea surface temperature under cloudy and lightly precipitating skies eliminating the need for additional thermal infrared imagers. The strategic plan for HIRAD includes a roadmap for ocean surface wind speed and OSVW technology development using flight demonstrations on piloted aircraft, uninhabited aerial vehicle systems, and satellite platforms. The roadmap will include exit opportunities for technology transfer from research to operations based on satisfactory demonstrations. The first aircraft version of HIRAD will be singular polarization sensor designed to observe ocean surface wind speed and rainfall. The second aircraft version of HIRAD will be dual polarization sensor designed to observe OSVW as a prototype for a future satellite sensor.

Source record↗

Carbon Nanotube Vacuum Gauges Utilizing Long, Dissipative Tubes

CNT Vacuum Gauges: a) have a broad range of pressure response from 760 - 10(exp -6) Torr. b) have current changes approx. 100's nA in high vacuum regime (10(exp -6) Torr) and sensitivity increases with power and substrate removal. c) have a negative dR/dT (TCR negative) where a thermal hopping energy E(sub a) was determined to be approx. 40 meV. d) have compatible fabrication requirements for their integration with micromachined structures. e) can be operated at low power (nW - micro-W). f) have an active device region footprint of < 10 sq microns. g) are non-intrusive due to small size and passive operation.

nanotube sensors↗

T Lymphocyte Activation Threshold and Membrane Reorganization Perturbations in Unique Culture Model

Quantitative activation thresholds and cellular membrane reorganization are mechanisms by which resting T cells modulate their response to activating stimuli. Here we demonstrate perturbations of these cellular processes in a unique culture system that non-invasively inhibits T lymphocyte activation. During clinorotation, the T cell activation threshold is increased 5-fold. This increased threshold involves a mechanism independent of TCR triggering. Recruitment of lipid rafts to the activation site is impaired during clinorotation but does occur with increased stimulation. This study describes a situation in which an individual cell senses a change in its physical environment and alters its cell biological behavior.

Adams, C. L.↗

CPAS Preflight Drop Test Analysis Process

Throughout the Capsule Parachute Assembly System (CPAS) drop test program, the CPAS Analysis Team has developed a simulation and analysis process to support drop test planning and execution. This process includes multiple phases focused on developing test simulations and communicating results to all groups involved in the drop test. CPAS Engineering Development Unit (EDU) series drop test planning begins with the development of a basic operational concept for each test. Trajectory simulation tools include the Flight Analysis and Simulation Tool (FAST) for single bodies, and the Automatic Dynamic Analysis of Mechanical Systems (ADAMS) simulation for the mated vehicle. Results are communicated to the team at the Test Configuration Review (TCR) and Test Readiness Review (TRR), as well as at Analysis Integrated Product Team (IPT) meetings in earlier and intermediate phases of the pre-test planning. The ability to plan and communicate efficiently with rapidly changing objectives and tight schedule constraints is a necessity for safe and successful drop tests.

Englert, Megan E.↗

Additively Printed Flexible Temperature Sensor for Wearable Applications

The flexible sensor has the capability to be mounted on any curved surfaces of applications and be used for portable devices. Additively printed sensors have received attention owing to their compact design and ability of application to non-planar surfaces. Wearable applications require capability of integration into a variety of surfaces with ability to flex, fold, twist and stretch under the stresses of daily motion. There is scarcity of data on the interaction of the process parameters with the realized performance. In addition, there is need for data focused on sensor accuracy, repeatability, and reliability. In this study, experimental analysis on function of the fabricated sensing board is conducted. The temperature sensors are made by direct write printing method with nScrypt printer. A calibration of the sensors has been conducted to confirm that resistance is well related to actual temperature and find TCR (temperature coefficient to resistance). The evolution of resistance has been correlated with the environmental temperature. The sensor hysteresis has been quantified using upswing and downswing of the environmental temperature. In addition, the effect of humidity on the temperature sensor accuracy and performance has been quantified. The effect of a polymide coat on the sensor to prevent humidity effects has also been quantified.

Pradeep Lall↗