Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TCAD modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

24 records · Page 2

Induced Current Detector Simulation

We describe simulations of a detector concept with small, low capacitance, pixels with pitch/thickness ratio on the order of 10. The simulation utilizes 2D and 3D TCAD simulations followed by a generic SPICE front-end model including noise and Landau fluctuations. We also investigate the properties of weighting fields of various geometries. We investigate whether the transient induced current signals can be used to improve pattern recognition and establish track angle.

43 PARTICLE ACCELERATORS↗

A unified thermionic and thermionic-field emission (TE–TFE) model for ideal Schottky reverse-bias leakage current

We present a unified thermionic emission (TE) and thermionic-field emission (TFE) model for the ideal reverse-bias leakage current in Schottky junctions. The unified TE–TFE analytical model advances upon previous analytical TFE models by Murphy–Good and Padovani–Stratton, which are the two most widely adopted models by the community, in two major aspects: (i) the applicability of the TFE expression therein is extended to near-zero surface electric fields by an error-function correction, allowing for the calculation of the total current by a nontrivial sum of TE (over-the-barrier current) and TFE (below-the-barrier current) contributions; therefore, an accurate description of the TE-to-TFE transition region is captured analytically for the first time; (ii) image-force lowering is considered with much-simpler correction terms. Comparisons with the reference numerical model show that the unified TE–TFE model has excellent accuracy, as well as a 10 000× reduction in computation time. The unified model is further tested against experimental data from Schottky barrier diodes based on Si, 4H-SiC, GaN, and β-Ga 2 O 3 , revealing accurate extractions of barrier heights and correct descriptions of the ideal reverse leakage characteristics. With the extended applicable range, improved accuracy, and computational efficiency, the unified TE–TFE model is highly valuable for the design and analysis of devices based on Schottky junctions, as well as for potential integration in technology computer-aided design (TCAD) tools.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of Vertical 2T-nC FeRAM Hybrid Cell and Its Scalability for High-Density 3-D Ferroelectric Capacitor Memory

In this work, we present a comprehensive experimental and modeling study on the scaling of vertical 2T-nC ferroelectric random access memory (FeRAM) hybrid cells, comprising n metal-ferroelectric–metal (MFM) capacitors, to demonstrate a high-performance and high-density 3-D capacitor memory. Our contributions include: 1) successful process integration of vertical 2T-3C FeRAM cells by stacking MFM structures on top of Si CMOS transistors; 2) experimental validation of memory cell functionality, confirming the feasibility of the vertical 2T-nC FeRAM architecture; 3) an analysis of scaling effects on parasitic capacitance in densely integrated 3-D arrays, using 3-D technology computer-aided design (TCAD) simulations; 4) exploration of aggressive stacking of write bitlines (WBLs) to enhance memory density, where ferroelectric linear capacitance ( C FE ) enables self-boosted inhibition under the V W /2 scheme, but renders the V W /3 scheme ineffective due to intolerable write disturbances; and 5) assessment of horizontal scaling, revealing significant increases in read disturbances caused by interplane capacitance between adjacent WBLs ( C Z ). This work represents an early exploration into the potential of 2T-nC FeRAM as a scalable and efficient 3-D memory solution.

42 ENGINEERING↗

Heavy Ion Induced Degradation in SiC Schottky Diodes: Bias and Energy Deposition Dependence

Experimental results on ion-induced leakage current increase in 4H-SiC Schottky power diodes are presented. Monte Carlo and TCAD simulations show that degradation is due to the synergy between applied bias and ion energy deposition. This degradation is possibly related to thermal spot annealing at the metal semiconductor interface. This thermal annealing leads to an inhomogeneity of the Schottky barrier that could be responsible for the increase leakage current as a function of fluence.

modeling↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗