Current Practices in Distribution Utility Resilience Planning for Winter Storms

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using Institute of Electrical and Electronics Engineers (IEEE) 1366-2022, which defines major events as an event that exceeds reasonable design and/or operational limits of the electric power system. Resilience planning is focused on major event days and reliability planning is focused on nonmajor event days. Utility resilience plans are assessed according to common resilience components identified in existing resilience frameworks. The focus of this report is on winter storms in which the primary hazards are heavy snowfall, freezing rain, ice, extreme cold, severe wind, and flooding. These hazards can also contribute to generation shortages, resulting in bulk power system impacts that have consequences for the distribution system, such as load shedding. Stand-alone reports focusing on wildfires and nonwinter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Current Practices in Distribution Utility Resilience Planning for Wildfires

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using IEEE 1366-2022, which defines major events as "an event that exceeds reasonable design and/or operational limits of the electric power system." Resilience planning is focused on major event days, and reliability planning is focused on non-major event days. Utility resilience plans are assessed according to common resilience components identified in existing resilience frameworks. The focus of this report is on wildfires. Standalone reports focusing on severe storms (including hurricanes and non-winter storms) and winter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Current Practices in Distribution Utility Resilience Planning for Hurricanes and Non-Winter Storms

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using IEEE 1366-2022, which defines "major events" as "an event that exceeds reasonable design and/or operational limits of the electric power system." Resilience planning is focused on "major event days" and reliability planning is focused on non-major event days. Utility resilience plans are assessed according to common recommended resilience components that we have identified in existing resilience frameworks. The focus of this report is on hurricanes and severe storms in which the primary hazards are precipitation or high winds. We exclude winter storms with primary hazards of ice and extreme cold, as they are a unique set of hazards with different resilience considerations. Standalone reports focusing on wildfires and winter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Distribution Grid Incentive Design with Unknown Agent Behavior

Motivation: During extreme events, traditional grid regulation methods (e.g., energy prices, net power injection limits) may be insufficient. While system operators typically lack control over end-user grid interactions, (e.g., energy demand), incentives can influence behavior - for example, a user that receives a grid-driven incentive may adjust their consumption or expose relevant control variables in response. Problem: Optimize for the best incentive subject to system stability constraints. However, user behavior is unknown to the SO - i.e., for a given incentive, the amount of curtailed load or control variables exposed is unknown.

feedback based control

Design, Optimization, and Control of Floating Offshore Wind Farms for Optimal Energy Production (Final report)

The uncertainty and irregularity of ocean waves and the ocean environment is a major factor in the development of commercial scale floating wind turbines as the operation of floating structures in such an environment can lead to irregular and unpredictable loading, fatigue, and ultimately a reduction in the operational life of the turbine system which affects energy production over the lifetime of the turbine. Control solutions that can limit float motions and mitigate stressful events on the structure become essential for extending lifetime and limiting the operational uncertainty of a floating wind turbine. Digital twins are computational replicas of physical systems that operate in parallel with the operation of the physical system. Given advanced knowledge of a systems input, digital twins have the ability to predict the behavior of a system in advance, which can be valuable in the control of that system. In this project, we developed and assessed potential digital twin models developed in house and openly available (OpenFast) for use in the real time control of the six degree of freedom response motions of a floating wind turbine in ocean waves. Coupling these models with near-field real time irregular sea surface (wve) measurement/sensings and prediction models, we used the digital twin to predict how the floating turbine will respond to the incoming waves. Applying this information to a motion control system of the float, one can limit and control float motions to prevent undesirable loading events/large angular motions, thus increasing system life and ultimately contributing to optimizing energy production. Due to the computational intensity of operating a digital twin in real time, we investigated the use of artificial intelligence techniques to speed-up the processes of the digital twin, as well as the wave reconstruction/prediction models. Model tank testing at the University of Rhode Island and University of Maine both validated and demonstrated the developed techniques on simple float geometries and a scale model of the NREL 15 MW reference turbine.

17 WIND ENERGY

Limiter-aware adaptive excitation control for hydropower generators with legacy voltage regulation systems

Hydropower units often rely on legacy excitation systems with fixed automatic voltage regulator (AVR) settings, but parameter drift, changing operating conditions, and evolving grid-service demands can degrade terminal-voltage regulation over time. This problem should be addressed because poor voltage regulation affects reactive-power support, system stability, and reliable plant operation, and replacing installed AVR and limiter logic is costly and disruptive in practice. To address this issue, this paper proposes a retrofit-friendly enhancement for hydropower generator excitation systems that combines adaptive tuning of the AVR middle lead–lag branch with a small proportional-integral correction for removing steady bias and slow drift. The adaptive laws are normalized, projection-bounded, and equipped with leakage, while adaptation is enabled only in the middle branch. Thus, the intent of the underexcitation and overexcitation limiters, as well as legacy current and rate limits, remains unchanged. Stability is analyzed under incremental performance assumptions, yielding boundedness and asymptotic tracking in the absence of saturation. The method is evaluated using real operational data from a utility-scale hydropower unit at Rocky Reach Dam, Unit C-8. Compared with the fixed AVR baseline, the proposed method reduces terminal-voltage mean squared error by about 70%, removes long periods of steady-state bias, and improves transient tracking while coexisting with limiter actions. These results show that substantial voltage-control improvement can be achieved on existing hydropower units with minimal integration effort and without replacing the installed AVR structure.

ESST5B model

Community structure and function during periods of high performance and system upset in a full-scale mixed microalgal wastewater resource recovery facility

Microalgae have the potential to exceed current nutrient recovery limits from wastewater, enabling water resource recovery facilities (WRRFs) to achieve increasingly stringent effluent permits. The use of photobioreactors (PBRs) and the separation of hydraulic retention and solids residence time (HRT/SRT) further enables increased biomass in a reduced physical footprint while allowing operational parameters (e.g., SRT) to select for desired functional communities. However, as algal technology transitions to full-scale, there is a need to understand the effect of operational and environmental parameters on complex microbial dynamics among mixotrophic microalgae, bacterial groups, and pests (i.e., grazers and pathogens) and to implement robust process controls for stable long-term performance. Here, we examine a full-scale, intensive WRRF utilizing mixed microalgae for tertiary treatment in the US (EcoRecover, Clearas Water Recovery Inc.) during a nine-month monitoring campaign. We investigated the temporal variations in microbial community structure (18S and 16S rRNA genes), which revealed that stable system performance of the EcoRecover system was marked by a low-diversity microalgal community (D INVSIMPSON = 2.01) dominated by Scenedesmus sp. (MRA = 55 %-80 %) that achieved strict nutrient removal (effluent TP < 0.04 mg·L -1 ) and steady biomass concentration (TSS monthly avg . = 400–700 mg·L −1 ). Operational variables including pH, alkalinity, and influent ammonium (NH 4 + ), correlated positively (p < 0.05, method = Spearman) with algal community during stable performance. Further, the use of these parameters as operational controls along with N/P loading and SRT allowed for system recovery following upset events. Importantly, the presence or absence of bacterial nitrification did not directly impact algal system performance and overall nutrient recovery, but partial nitrification (potentially resulting from NO 2 − accumulation) inhibited algal growth and should be considered during long-term operation. The microalgal communities were also adversely affected by zooplankton grazers (ciliates, rotifers) and fungal parasites (Aphelidium), particularly during periods of upset when algal cultures were experiencing culture turnover or stress conditions (e.g., nitrogen limitation, elevated temperature). Altogether, the active management of system operation in order to maintain healthy algal cultures and high biomass productivity can result in significant periods (>4 months) of stable system performance that achieve robust nutrient recovery, even in winter months in northern latitudes (WI, USA).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Continuous operation of a coherent 3,000-qubit system

Neutral atoms are a promising platform for quantum science, enabling advances in areas ranging from quantum simulations and computation to metrology, atomic clocks and quantum networking. Although atom losses typically limit these systems to a pulsed mode, continuous operation could substantially enhance cycle rates, remove bottlenecks in metrology and enable deep-circuit quantum evolution through quantum error correction. Here we demonstrate an experimental architecture for high-rate reloading and continuous operation of a large-scale atom-array system while realizing coherent storage and manipulation of quantum information. Our approach utilizes a series of two optical lattice conveyor belts to transport atom reservoirs into the science region, where atoms are repeatedly extracted into optical tweezers without affecting the coherence of qubits stored nearby. Using a reloading rate of 300,000 atoms in tweezers per second, we create over 30,000 initialized qubits per second, which we leverage to assemble and maintain an array of over 3,000 atoms for more than 2 hours. Furthermore, we demonstrate persistent refilling of the array with atomic qubits in either a spin-polarized or a coherent superposition state while preserving the quantum state of stored qubits. Our results pave the way for the realization of large-scale continuously operated atomic clocks, sensors and fault-tolerant quantum computers.

atomic and molecular physics

Nonlinear analog processing with anisotropic nonlinear films

Digital signal processing is the cornerstone of several modern-day technologies, yet in multiple applications it faces critical bottlenecks related to memory and speed constraints. Thanks to recent advances in metasurface design and fabrication, light-based analog computing has emerged as a viable option to partially replace or augment digital approaches. Several light-based analog computing functionalities have been demonstrated using patterned flat optical elements, with great opportunities for integration in compact nanophotonic systems. So far, however, the available operations have been restricted to the linear regime, limiting the impact of this technology to a compactification of Fourier optics systems. In this paper, we introduce nonlinear operations to the field of metasurface-based analog optical processing, demonstrating that nonlinear optical phenomena, combined with nonlocality in flat optics, can be leveraged to synthesize kernels beyond linear Fourier optics, paving the way to a broad range of new opportunities. As a practical demonstration, we report the experimental synthesis of a class of nonlinear operations that can be used to realize broadband, polarization-selective analog-domain edge detection.

analog image processing

Modular Processing of Flare Gas for Carbon Nanoproducts

This project demonstrated the technical viability and economic promise of a modular system for converting flared natural gas into valuable carbon nanoproducts (CNPs) through catalytic chemical vapor deposition (CVD). All major project milestones were successfully completed, including reactor design and commissioning, catalyst development, process optimization, technoeconomic analysis, and application testing in concrete systems. The overarching goal was to create a scalable, field-deployable process that valorizes stranded methane by producing high-value carbon materials for use in cementitious composites. At the lab scale, the team designed and built a fluidized bed reactor optimized for use with silica fume-supported nickel catalysts synthesized via atomic layer deposition (ALD). A statistically designed sintering study enabled precise tuning of nickel nanoparticle size, identifying the influence of oxygen partial pressure, time, and temperature on catalyst morphology and performance. These insights allowed the team to target catalyst conditions that maximize carbon nanofilament growth. Subsequent CVD experiments achieved up to 31.8 wt% carbon deposition under optimized conditions, with TEM confirming the presence of nanofilament structures and sustained hydrogen evolution during reaction. Reactor upgrades and empirical fluidization studies supported the development of reliable, repeatable experimental protocols. The modular pilot-scale skid reactor was fully constructed, instrumented, and commissioned. Capable of operating at 675–800°C and pressures up to 290 psig, the system was designed for continuous operation at a carbon production rate of 1 kg/hr. Initial demonstration runs confirmed solids handling, thermal control, and system leak-tightness, although a critical reactor component (the downfeed tube) was inadvertently omitted during final assembly. This omission limited gas–solid contact and prevented meaningful carbon deposition during pilot-scale CVD runs. Nonetheless, the system operated safely under design conditions, and the root cause of performance limitations was clearly identified. Complementary work on UHPC formulations demonstrated that small additions of carbon nanoproducts, including those derived from flare gas, can significantly enhance mechanical performance while preserving workability. A comprehensive study of CNF dispersion techniques and mix design optimization led to a clear protocol for integrating these nanomaterials into concrete. Incorporation of CNPs improved flexural toughness and reduced porosity, supporting their use in high-performance infrastructure applications. A technoeconomic analysis (TEA) confirmed that this process can produce CNP-loaded catalyst material at a levelized cost below $\$$7/kg across a range of catalyst loadings and reaction yields. With estimated market values for the carbon composite product ranging from $\$$14 to over $\$$60/kg, and the ability to blend CNPs into concrete at sub-percent levels with less than 10% added cost, the system presents a compelling economic case. While additional engineering work is needed to optimize fluidization and heat transfer at scale, this project establishes a strong foundation for commercial development. The process is not only technically sound but also economically promising, representing a viable pathway for flare gas mitigation through modular carbon nanomaterial production.

03 NATURAL GAS

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Enhancing heat pump water heater performance with embedded phase change materials thermal energy storage: First hour rating improvement and demand response operation

The increasing global emphasis on energy efficiency and sustainability has put heat pump water heaters (HPWHs) in the spotlight as an energy-efficient alternative to traditional water heating systems. However, their widespread adoption is limited by challenges such as insufficient First Hour Rating (FHR), suboptimal control mechanisms, and limited flexibility for demand response operations. Here, to address these limitations, this study proposes an innovative HPWH system integrated with embedded phase change material (PCM)-based thermal energy storage (TES). The research introduces a novel design and control strategy that leverages optimized PCM integration to enhance thermal storage capacity, improve hot water delivery during peak demand, and increase load-shifting potential. A combination of system modeling, performance simulation, and demand response control strategy evaluation was employed to quantify the benefits of PCM integration. Results demonstrate that the proposed PCM-TES HPWH system significantly enhances FHR, with an optimal 7.0 lb. of PCM increasing FHR by over 26 %—from 62 to 78 gal—for a standard 50-gal HPWH. Additionally, under advanced demand response operation using a preheat strategy, the system reduces the percentage of control temperature out-of-band time from 65 % (conventional HPWH) to just 11.6 %, enabling a more stable and efficient hot water supply. This research contributes a novel PCM-embedded HPWH design and control framework that addresses both performance and grid-interactivity challenges. The findings offer a viable pathway to enhancing the operational efficiency, flexibility, and grid responsiveness of residential water heating systems.

Demand response control

Expanded Accident Scenarios and Frequency Characteristics for a Fast Spectrum Molten Salt Reactor in an Integrated Energy System

Integration of advanced nuclear reactors to industrial processes in an integrated energy system (IES) has many potential advantages. The coupling of nuclear power to varied industrial processes introduces additional accident scenarios unique to the specific systems included in the IES. Similarly, noise in one system of the IES could potentially create negative effects in the other systems. Because of the limited amount of comparable nuclear IES operating experience, there is added value in scoping the inherent behavior of these systems in response to these transients. Here, this paper investigates the safety-related behavior of an open-source IES dynamic model of a fast spectrum molten salt reactor (MSR) powering a regenerative Rankine cycle for electricity production and a hybrid sulfur (HyS) cycle for hydrogen production. The simulations include a loss of cooling water to the Rankine cycle, a loss of sulfur in the HyS cycle, and the frequency characteristics of the entire IES across six orders of magnitude of frequency. The results show safe behavior in response to the two accident scenarios, wherein a disruption in heat transfer leads to increased salt temperatures and a decrease in reactor power. The frequency analysis shows that at higher frequencies, temperature changes propagating through an IES are increasingly damped to the point of negligibility.

Dunkle, Nicholas [Univ. of Tennessee, Knoxville, T

Kivalina Biomass Reactor

This report summarizes work performed under DOE Award DE-EE00010149 to support the reliable operation of a community-scale biochar reactor system in Kivalina, Alaska. The project focused on improving sanitation and waste management in a remote community by assessing the installed system, identifying spare parts, defining key performance indicators (KPIs), preparing operator and maintenance manuals, and developing mobile reporting tools for operational data and KPI tracking. The team also produced training materials and recorded videos to support operator onboarding and continuity. The project demonstrated progress in system readiness, documentation, and digital reporting, while also identifying challenges common to remote deployments, including travel constraints, upstream system failures, and local resource limitations. This work provides a practical framework for improving the operation, monitoring, and future replication of biomass reactor systems in remote communities.

09 BIOMASS FUELS

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION

Frequency Control and Dynamics (Part 1) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION

Frequency Control and Dynamics (Part 2) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION

Compensating for Amplifier Non-Linearity in a SEL Controller

The SEL architecture used commonly in CW superconducting linacs is a positive feedback system that requires determining the correct limits for the operating conditions to ensure stable operation. These limits are determined from the results of the amplifier calibration which characterizes the dac drive(forward power) against the cavity field. When the amplifier non-linearity precludes a simple linear fit for this characteristic, its modification to account for the amplifiers non-linearity is essential to operate the system in the SEL architecture. This process is described with test data from a 32kW SSA for the PIP-II linac.