Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Synchrotron light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Long Island Steatite Sourcing from Rhode Island Quarries During the Late Holocene Era

This study aimed to investigate the possible sourcing of Long Island steatite artifacts from quarries in Rhode Island. Seven steatite samples from archeological sites on Long Island including Nassau County, Suffolk County (North Fork and South Fork) and Shelter Island were compared to two Rhode Island quarry sample putative sources using X-ray fluorescence (XRF) microscopy at the Submicron Resolution X-ray spectroscopy (SRX) beamline of the National Synchrotron Light Source II at Brookhaven National Laboratory. The site-derived steatite samples displayed numerous similarities in elemental composition compared to the two Rhode Island quarries, Oaklawn and Ochee Springs. This study provides new evidence to support the possible sourcing of Long Island steatite from Rhode Island during the late Holocene era.

54 ENVIRONMENTAL SCIENCES

Characterization of Gas Bremsstrahlung sources at the Electron-Ion Collider

This report estimates the potential impact of Gas Bremsstrahlung, generated as the electron beam traverses the straight sections of the storage ring and impinges onto selected locations of the Electron-Ion Collider. The source terms were calculated for routine operation scenarios at three different energies: 5, 10 and 18 GeV, using the FLUKA Monte Carlo particle transport and interaction code. The source term’s power distributions were validated and compared with the Gas Bremsstrahlung produced in the long straight sections of the National Synchrotron Light Source II storage ring.

43 PARTICLE ACCELERATORS

Macromolecular crystallography and biology at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) has significantly impacted the field of biology by providing advanced capabilities for probing the structure and dynamics of biological molecules with high precision. The ultrashort coherent X-ray pulses from the LCLS have enabled ultrafast, time-resolved, serial femtosecond crystallography that is inaccessible at conventional synchrotron light sources. Since the facility's founding, scientists have captured detailed insights into biological processes at atomic resolution and fundamental timescales. The ability to observe these processes in real time and under conditions closely resembling their natural state is transforming our approach to studying biochemical mechanisms and developing new medical and energy applications. This work recounts some of the history of the LCLS, advances in biological research enabled by the LCLS, key biological areas that have been impacted and how the LCLS has helped to unravel complex biological phenomena in these fields.

59 BASIC BIOLOGICAL SCIENCES

A general Bayesian algorithm for the autonomous alignment of beamlines

Autonomous methods to align beamlines can decrease the amount of time spent on diagnostics, and also uncover better global optima leading to better beam quality. The alignment of these beamlines is a high-dimensional expensive-to-sample optimization problem involving the simultaneous treatment of many optical elements with correlated and nonlinear dynamics. Bayesian optimization is a strategy of efficient global optimization that has proved successful in similar regimes in a wide variety of beamline alignment applications, though it has typically been implemented for particular beamlines and optimization tasks. In this paper, we present a basic formulation of Bayesian inference and Gaussian process models as they relate to multi-objective Bayesian optimization, as well as the practical challenges presented by beamline alignment. We show that the same general implementation of Bayesian optimization with special consideration for beamline alignment can quickly learn the dynamics of particular beamlines in an online fashion through hyperparameter fitting with no prior information. We present the implementation of a concise software framework for beamline alignment and test it on four different optimization problems for experiments on X-ray beamlines at the National Synchrotron Light Source II and the Advanced Light Source, and an electron beam at the Accelerator Test Facility, along with benchmarking on a simulated digital twin. We discuss new applications of the framework, and the potential for a unified approach to beamline alignment at synchrotron facilities.

47 OTHER INSTRUMENTATION

Performance of the PRAXyS X-Ray Polarimeter

The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven National Laboratory, National Synchrotron Light Source (BNL-NSLS) and at NASA's Goddard Space Flight Center. The polarimeter was tested with linearly polarized, monochromatic X-rays at 11 different energies between 2.5 and 8.0 keV. At maximum sensitivity, the measured modulation factors at 2.7, 4.5 and 8.0 keV are 27%, 43% and 59%, respectively and the measured angle of polarization is consistent with the expected value at all energies. Measurements with a broadband, unpolarized X-ray source placed a limit of less than 1% on false polarization in the PRAXyS polarimeter.

PRAXyS

Design Improvements and X-Ray Performance of a Time Projection Chamber Polarimeter for Persistent Astronomical Sources

The design of the Time-Projection Chamber (TPC) Polarimeter for the Gravity and Extreme Magnetism Small Explorer (GEMS) was demonstrated to Technology Readiness Level 6 (TRL-6)3 and the flight detectors fabricated, assembled and performance tested. A single flight detector was characterized at the Brookhaven National Laboratory Synchrotron Light Source with polarized X-rays at 10 energies from 2.3-8.0 keV at five detector positions. The detector met all of the GEMS performance requirements. Lifetime measurements have shown that the existing flight design has 23 years of lifetime4, opening up the possibility of relaxing material requirements, in particular the consideration of the use of epoxy, to reduce risk elsewhere. We report on design improvements to the GEMS detector to enable a narrower transfer gap that, when operated with a lower transfer field, reduces asymmetries in the detector response. In addition, the new design reduces cost and risk by simplifying the assembly and reducing production time. Finally, we report on the performance of the narrow-gap detector in response to polarized and unpolarized X-rays.

GEMS

Advanced Characterization in Advanced Manufacturing Workshop

The Advanced Manufacturing (AM) Work shop successfully convened experts from government, academia, and industry to address pressing scientific challenges and strengthen the AM user community. The workshop was held at the U.S. Department of Energy’s (DOE) Brookhaven National Laboratory during the National Synchrotron Light Source II (NSLS-II) and Center for Functional Nanomaterials (CFN) Users’ Meeting. Participation included researchers from Stony Brook University, Massachusetts Institute of Technology, Yale University, Harvard University, Columbia University, and several other institutions across the United States and the world. In conclusion, the program featured three complementary components—oral presentations, a facility tour, and a brainstorming session— that together fostered collaboration and high lighted the transformative role of synchrotron based characterization in AM.

36 MATERIALS SCIENCE

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology

Non-destructive trace element microanalysis of as-received cometary nucleus samples using synchrotron x ray fluorescence

The Synchrotron X ray Fluorescence (SXRF) microprobe at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, will be an excellent instrument for non-destructive trace element analyses of cometary nucleus samples. Trace element analyses of as-received cometary nucleus material will also be possible with this technique. Bulk analysis of relatively volatile elements will be important in establishing comet formation conditions. However, as demonstrated for meteorites, microanalyses of individual phases in their petrographic context are crucial in defining the histories of particular components in unequilibrated specimens. Perhaps most informative in comparing cometary material with meteorites will be the halogens and trace metals. In-situ, high spatial resolution microanalyses will be essential in establishing host phases for these elements and identifying terrestrial (collection/processing) overprints. The present SXRF microprobe is a simple, yet powerful, instrument in which specimens are excited with filtered, continuum synchrotron radiation from a bending magnet on a 2.5 GeV electron storage ring. A refrigerated cell will be constructed to permit analyses at low temperatures. The cell will consist essentially of an air tight housing with a cold stage. Kapton windows will be used to allow the incident synchrotron beam to enter the cell and fluorescent x rays to exit it. The cell will be either under vacuum or continuous purge by ultrapure helium during analyses. Several other improvements of the NSLS microprobe will be made prior to the cometary nucleus sample return mission that will greatly enhance the sensitivity of the technique.

Sutton, S. R.

Adaptively coupled phase retrieval in multi-peak Bragg coherent diffraction imaging

Recent advances in Bragg coherent diffraction imaging (BCDI) experimental techniques permit routine measurement of multiple Bragg peaks from a single crystalline grain. The resulting images contain the full lattice distortion vector field which can be differentiated to provide lattice strain and rotation. With the advent of fourth-generation synchrotron light sources, such multi-peak datasets are produced at high rates, facilitating the need for rapid phase retrieval of the multiple peaks and subsequent image analysis. Here we describe and demonstrate a new implementation of a coupled phase retrieval technique for multi-peak BCDI which simultaneously treats each Bragg peak of the dataset and produces a three-dimensional image of the crystal's morphology and lattice distortion field. In addition, this method uses the redundant information contained in the various Bragg diffraction patterns to detect and suppress spurious signal appearing on the detector in a subset of the measurements. Compared with manual data editing, adaptive coupling produces a more consistent phase profile in reciprocal space and sharper surfaces in direct space, with no significant difference in computational cost. These improvements reduce the need for manual preprocessing and enable robust high-throughput analysis of multi-peak BCDI data, supporting near-real-time strain microscopy at modern synchrotron facilities.

36 MATERIALS SCIENCE

Adaptive X-ray imaging with reinforcement learning

X-ray imaging is a powerful technique to scan samples in a variety of contexts including biological, environmental and materials science, but commonly requires a synchrotron light source to produce X-rays at sufficient intensity. As these facilities are expensive to operate, the available beam time is limited and always in high demand. Particularly if the illuminated samples are sparse, standard raster scanning methods can be time-consuming, with a majority of that time being spent on areas of the image that carry little information. To increase the efficiency and maximize the information gain for a given time budget, we split the scanning process into a series of steps where previous measurements are used to inform the decision making and adapt the exposure distribution at later stages of the sequence. We formulate this task as a reinforcement learning problem where the goal is to produce a sequence of exposure maps that maximize a predefined scalar metric. We demonstrate the potential of this approach in simulations where the adaptive illumination can accelerate the measurement process by up to an order of magnitude compared with standard raster scanning. Finally, we present the first results from deploying the trained agents on an X-ray fluorescence beamline at the Stanford Synchrotron Radiation Lightsource.

Reinforcement Learning

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE

Recent progress in high-temperature superconducting undulators

Considerable effort has been devoted to the development of superconducting undulators (SCUs) intended for particle accelerator-based light sources, including synchrotrons and free electron laser (FEL) facilities. Recently, a high-temperature superconducting (HTS) undulator prototype, consisting of staggered-array Re-Ba-Cu-O bulks, achieved an on-axis sinusoidal magnetic field profile with a peak amplitude B$_0$ of 2.1 T and a period length of 10 mm, resulting in a deflection parameter K = 1.96. Such a short period HTS undulator not only enables the generation of higher-energy photons, but also supports the construction of economically feasible and compact FELs with shorter linear accelerators (LINACs). This article provides a comprehensive review of recent advances in the staggered-array bulk HTS undulator as well as other types of HTS undulators. Furthermore, it offers insights into the development of engineering HTS undulator prototypes designed for deployment in synchrotron and free electron laser (FEL) facilities. We conclude by discussing opportunities for and the challenges facing the use of HTS undulators in practical applications.

43 PARTICLE ACCELERATORS

From natural language to control signals: a conceptual framework for semantic channel finding in complex experimental infrastructure

Modern experimental platforms such as particle accelerators, fusion devices, telescopes, and industrial process control systems expose tens to hundreds of thousands of control and diagnostic channels, accumulated over decades of hardware evolution. Operators and AI systems alike depend on informal expert knowledge, inconsistent naming conventions, and scattered documentation to locate the signals required for monitoring, troubleshooting, and automated control, creating a persistent bottleneck for reliability, scalability, and emerging language-model-driven interfaces. We formalize semantic channel finding, the task of mapping natural-language intent to concrete control-system signals, as a general problem in complex experimental infrastructure, and introduce a four-paradigm conceptual framework to guide architecture selection based on facility-specific data regimes. The paradigms span (i) direct in-context lookup over small, curated channel dictionaries, (ii) constrained hierarchical navigation through structured trees, (iii) interactive agent exploration using iterative reasoning and tool-based database queries, and (iv) ontology-grounded semantic search that decouples channel meaning from facility-specific naming conventions. We demonstrate the practical feasibility of each paradigm through proof-of-concept implementations at four operational facilities spanning two orders of magnitude in scale: from compact free-electron lasers to large synchrotron light sources, operating under diverse control-system architectures ranging from clean hierarchical naming schemes to legacy environments with decades of heterogeneous conventions. Where evaluated against expert-curated operational queries, these instantiations achieve 90%–97% accuracy, validating the framework’s applicability across real-world deployment scenarios. To accelerate adoption across the broader scientific and industrial control-system community, we release open-source, plug-and-play implementations of all three interactive paradigms-direct lookup, hierarchical navigation, and middle-layer exploration-within the Osprey framework, together with tools for channel database generation, interactive testing, and minimal-configuration deployment. This work establishes semantic channel finding as a foundational capability for human-centric and agentic AI interfaces at large-scale facilities, providing both a systematic framework for architecture design and practical resources to enable adoption without building custom infrastructure from scratch.

channel finding

Agentic artificial intelligence for multistage physics experiments at a large-scale user facility particle accelerator

We present a language-model-driven agentic artificial intelligence (AI) system to autonomously execute multistage physics experiments on a production synchrotron light source. Implemented at the Advanced Light Source particle accelerator, the system translates natural language user prompts into structured execution plans that combine archive data retrieval, control-system channel resolution, automated script generation, controlled machine interaction, and analysis. In a representative machine physics task, we show that preparation time was reduced by 2 orders of magnitude relative to manual scripting even for a system expert, while operator-standard safety constraints were strictly upheld. Core architectural features, plan-first orchestration, bounded tool access, and dynamic capability selection, enable transparent, auditable execution with fully reproducible artifacts. These results establish a blueprint for the safe integration of agentic AI into accelerator experiments and demanding machine physics studies, as well as routine operations, with direct portability across accelerators worldwide and, more broadly, to other large-scale scientific infrastructures.

Accelerator/storage ring control systems

Effects of Melt Processing on Evolution of Structure in PEEK

We report on the effects of melt processing temperature on structure formation in Poly(ether-ether-ketone), PEEK. Real time Small Angle X-ray Scattering, SAXS, and thermal analysis are used to follow the melting behavior after various stages of processing. Assignment of peaks to structural entities within the material, the relative perfection of the crystals, and the possibility of their reorganization, are all influenced by the melt processing history. With the advent of high intensity synchrotron sources of X-radiation, polymer scientists gain a research tool which, when used along with thermal analysis, provides additional structural information about the crystals during growth and subsequent melting. PEEK is an engineering thermoplastic polymer with a very high glass transition temperature (145 C) and crystal melting point (337 C). PEEK has been the subject of recent studies by X-ray scattering in which melt and cold crystallization were followed in real-time. X-ray scattering and thermal studies have been used to address the formation of dual endothermic response which has been variously ascribed to lamellar insertion, dual crystal populations, or melting followed by re-crystallization. Another important issue is whether all of the amorphous phase is located in interlamellar regions, or alternatively whether some is located in "pockets" away from the crystalline lamellar stacks. The interpretation of scattering from lamellar stacks varies depending upon whether such amorphous pockets are formed. Some groups believe all of the amorphous phase is interlamellar. This leads to selection of a smaller thickness for the crystals. Other groups suggest that most amorphous phase is not interlamellar, and this leads to the suggestion that the crystal thickness is larger than the amorphous layer within the stacks. To investigate these ideas, we used SAXS and Differential Scanning Calorimetry to compare results of single and dual stage melt crystallization of PEEK using a treatment scheme involving annealing/crystallization at T(sub a1) followed by annealing at T(sub a2) where either T(sub a1) < T(sub a2) or T(sub a1) > T(sub a2). We proposed a model to explain multiple melting endotherms in PPS, treated according to one or two-stage melt or cold crystallization. Key features of this model are that multiple endotherms: (1) are due to reorganization/recrystallization after cold crystallization; and, (2) are dominated by crystal morphology after melt crystallization at high T. In other words, multiple distinct crystal populations are formed by the latter treatment, leading to observation of multiple melting. PEEK 45OG pellets (ICI Americas) were the starting material for this study. Films were compression molded at 400 C, then quenched to ice water. Samples were heated to 375 C in a Mettler FP80 hot stage and held for three min. to erase crystal seeds before cooling them to T(sub a1) = 280 C . Samples were held at T(sub a2) for a period of time, then immediately heated to 360 C. In the second treatment samples were held at T(sub a1) = 31 C for different crystallization times t(sub c) then cooled to 295 C and held 15 min. In situ (SAXS) experiments were performed at the Brookhaven National Synchrotron Light Source with the sample located inside the Mettler hot stage. The system was equipped with a two-dimensional position sensitive detector. The sample to detector distance was 172.7 cm and the X-ray wavelength was 1.54 Angstroms. SAXS data were taken continuously during the isothermal periods and during the heating to 360 C at 5 C/min. Each SAXS scan was collected for 30 sec. Since the samples were isotropic, circular integration was used to increase the signal to noise ratio. After dual stage melt crystallization with T(sub a1) < T(sub a2) the lower melting endotherm arises from holding at T(sub a1). During cooling a broad distribution of crystals forms, and the low-melting tail is perfected during T(sub al). Heating to T(sub a2) melts these imperfect crystals and allows others with greater average long spacing to form in their place. After dual stage crystallization with T(sub a1) > T(sub a2), the amount of space remaining for additional growth at T(sub a2) depends upon the holding time at T(sub a1). The long period of crystals formed at T(sub a2) is smaller than that formed at T(sub a1) due to growth in a now-restricted geometry. Perfection of crystals is seen as an increase of the intensity of the population scattering at higher s, while the intensity of the population scattering at lower s stays constant. During heating from below to above the minor endotherm, we see rapid decrease of the intensity of the X-ray scattering corresponding to the population of crystals scattering in the shoulder. Another important observation is that after the sample is annealed at 295 C, the shoulder intensity is restored once again. The population scattering at higher s remains longer before it disappears in the sample treated to the second stage of melt crystallization, compared to the sample crystallized with a single stage. This could be interpreted as an effect of continued perfection of the less perfect population, which is also reflected in the increased melting temperature of the smaller endotherm as the holding time at 295 C increases. In the corresponding DSC scans we see a shift in the area and the peak temperature of the lower melting endotherm with an increase of the annealing time.

Georgiev, Georgi

JuTrack: A Julia package for auto-differentiable accelerator modeling and particle tracking

Efficient accelerator modeling and particle tracking are key for the design and configuration of modern particle accelerators. In this work, we present JuTrack, a nested accelerator modeling package developed in the Julia programming language and enhanced with compiler-level automatic differentiation (AD). With the aid of AD, JuTrack enables rapid derivative calculations in accelerator modeling, facilitating sensitivity analyses and optimization tasks. Here we demonstrate the effectiveness of AD-derived derivatives through several practical applications, including sensitivity analysis of space-charge-induced emittance growth, nonlinear beam dynamics analysis for a synchrotron light source, and lattice parameter tuning of the future Electron-Ion Collider (EIC). Through the incorporation of automatic differentiation, this package opens up new possibilities for accelerator physicists in beam physics studies and accelerator design optimization.

43 PARTICLE ACCELERATORS

Elucidating the Origins of High Capacity in Iron-Based Conversion Materials: Benefit of Complementary Advanced Characterization toward Mechanistic Understanding

Lithium-ion batteries are recognized as an important electrochemical energy storage technology due to their superior volumetric and gravimetric energy densities. Graphite is widely used as the negative electrode, and its adoption enabled much of the modern portable electronics technology landscape. However, developing markets, such as electric vehicles and grid-scale storage, have increased demands, including higher energy content and a diverse materials supply chain. Alternatives that provide the opportunity to increase capacity and address supply chain concerns are of interest. Understanding the fundamental mechanisms that govern battery function is crucial to driving further improvements in the field. Advanced characterization techniques, such as those enabled by synchrotron light sources and high-resolution electron microscopes, that can uncover these mechanisms have become a necessity for elucidating structural evolution upon electrochemical conversion at the nano- to mesoscales. Performing these experiments with relevant electrochemistry using in situ and operando experiments imparts the ability to identify critical reaction pathways and capture intermediate (dis)charge products not discernible by traditional experiments.

36 MATERIALS SCIENCE