Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Subcritical Assembly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nuclear Data Libraries Sensitivity Studies for ORSA Using SCALE

Subcritical assemblies offer valuable training capabilities in nuclear criticality safety (NCS) for individuals handling fissile material. At Oak Ridge National Laboratory(ORNL), the Oak Ridge Subcritical Assembly (ORSA), a new experimental facility, is being established to provide hands-on training for the Nuclear Criticality Safety Program (NCSP).It is essential to accurately determine the neutron multiplication factor (keff) to ensure that ORSA remains subcritical and safe during operations. This study investigated the sensitivity of keff to variations across Evaluated Nuclear Data File (ENDF/B) libraries, consisting of ENDF/B-VII.1, ENDF/B-VIII.0, and ENDF/B-VIII.1. The analysis was conducted using the CSAS6 sequence in the SCALE-6.3 code system. Individual isotopes in the ORSA model were replaced one at a time with ENDF/B-VII.1 as the base library and changing to ENDF/B-VIII.0or ENDF/B-VIII.1. The results demonstrated that the changes in keffof the nuclides associated with the ORSA model were mostly within the uncertainty of the base model (~24 pcm), except for primary nuclides like Uranium-235and H-poly with few other nuclides. The relative delta keff values of Uranium-235 and H-poly, expressed in pcm, were +280 and -212 in ENDF/B-VIII.0 and +332 and -275 in ENDF/B-VIII.1, respectively, which were notable changes in reactivity. These results demonstrated that ORSA was largely insensitive to variations across these nuclear data libraries.

Hong, Evan [North Carolina State University]↗

Neutron Source Facility of the National Science Center “Kharkiv Institute of Physics and Technology” at Kharkiv, Ukraine

Argonne National Laboratory developed, designed, and supported the construction of a state-of-the-art Neutron Source Facility (NSF) at the Kharkov Institute of Physics and Technology (KIPT) in Kharkov Ukraine, under the U.S. DOE NNSA Russian Research Reactor Fuel Return (RRRFR) program. Ukraine approved the return of all highly enriched uranium in the country to Russia prior to the 2012 Nuclear Security Summit in return for the RRRFR program to fund the development, the design, and the construction of the NSF. The facility is designed to produce medical isotopes, train nuclear professionals, support the Ukrainian nuclear industry, and provide experimental capabilities for performing reactor physics, materials, and basic science research. The NSF was successfully started and operated in August 2021. The NSF is the first facility of this type in the world, and it will be used to understand the physics of driven systems for energy production and the disposal of spent nuclear fuels. The NSF consists of a subcritical assembly using low enriched uranium (LEU) fuel driven with an electron accelerator. The NSF target design utilizes tungsten or natural uranium for producing neutrons through photonuclear reactions using 100-MeV electrons. The accelerator power is 100 KW, which produces 3x10 14 neutrons per second from the uranium target. The subcritical assembly is designed to obtain the highest possible neutron flux intensity with an effective neutron multiplication factor of less than 0.98. Passive safety, reliability, and environmental considerations were included in the NSF design. The NSF utilization study shows that this neutron source has the capability of producing different medical isotopes. Several horizontal neutron channels are incorporated for performing applied and basic research. The NSF is configured to accommodate future design upgrades and new missions. The facility design was approved by the Ukraine Academy of Sciences before starting the NSF construction. The construction, the equipment installation, and the operation of the different systems of the NSF were completed and approved by the Ukrainian regulators. In July 2020, the State Nuclear Regulatory Inspectorate of Ukraine (SNRIU) issued a license for the physical startup of the NSF. The construction of facility was completed in early 2021.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The fast neutron source at UTK: a project with Massimo Salvatores

This article is dedicated to the memory of Massimo Salvatores and offers an overview of the history of the design of the Fast Neutron Source (FNS) flexible experiment system at the University of Tennessee. Our collaboration with Massimo set much of the over-arching design goals and inspired the concept that we have today. The decision to design the FNS as a subcritical assembly rather than a critical one stems back to discussions with Massimo Salvatores and his advocacy for subcritical Accelerator Driven Systems (ADS) which coincides with lower licensing time, costs and greater safety for a university-operated nuclear experimental facility. The second contribution of Massimo to the design concept of the FNS was the direct instruction to design the FNS as an extremely flexible facility. This article provides an update on the current design concept and discusses the future innovations in design optimization of flexible, re-configurable nuclear experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi-Objective Optimization of Uranium Target Assembly–3: A Comparison of Genetic and Traditional Methods

Commonly produced as a byproduct of uranium fission, 99 Mo is a key medical isotope that is in high demand in the United States. An international goal is to switch from medical isotope production technologies that require highly enriched uranium to medical isotope production technologies that require only low-enriched uranium. Niowave Inc. is contributing to this goal by developing an accelerator-driven subcritical assembly called the Uranium Target Assembly (UTA). This work compares the performance of Dakota’s Multi-Objective Genetic Algorithm (MOGA) against traditional sensitivity analysis in the neutronic optimization of the UTA-3 system. The design objectives are k-eigenvalue (k eff ) and natural uranium fission power, which are directly correlated with the amount of 99 Mo produced. Dakota:MOGA did not perform as well as human engineering ingenuity in optimization studies with high numbers of input parameters, such as fuel rod type selection and fuel rod placement. However, Dakota:MOGA did outperform traditional sensitivity analysis in optimization studies with fewer than 20 parameters and revealed the degree to which each parameter influences the optimal design space for k eff and natural uranium fission power (to a lesser extent). As the design model became more complex in the final stage of design, the computational resources required to calculate the design objective values in the Monte Carlo N-Particle transport code from selected input parameter combinations limited Dakota:MOGA’s performance, and, unfortunately, human intervention was required to discern the optimal design space. In conclusion, future work will attempt to reduce computational resource constraints by incorporating areduced-order neutronics model into the optimization cycle.

Accelerator-driven systems↗

The neutron number probability distribution in coupled lumped assemblies

Here, the validity of the gamma distribution in describing the neutron number probability distribution function for both isolated and coupled multiplying assemblies when constrained to reproduce the true mean and variance is investigated in lumped geometry by numerical comparison with kinetic Monte Carlo simulations. The mean and variance are obtained from numerical solution of moment equations constructed from the relevant forward Master equation with assembly coupling coefficients obtained from a view factor method. Numerical results for a two-group, two coupled assemblies model, with static and dynamic reactivity insertion, show that except for subcritical assemblies, the gamma distribution well-approximates the number distribution. Differences in the fast and thermal neutron population shapes are explained in terms of effective source strengths due to downscatter and coupling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview and Current Progress of the DOE/NNSA Nuclear Criticality Safety Program Training and Education Program

Since 2011, the US Department of Energy/National Nuclear Security Administration (DOE/NNSA) Nuclear Criticality Safety Program (NCSP) has been providing a two-week nuclear criticality safety (NCS) practitioner course to support the training and qualification of new NCS staff. In 2013, an NCS Manager’s course was developed for process supervisors, managers, regulators, and other professionals with NCS-related responsibilities, and, in 2017, an additional course was proposed for Criticality Safety Officers (CSOs). In addition to hands-on training, other NCSP-funded tasks include training on sensitivity/uncertainty methods, NCS resource pipeline tasks, development of NCS guides, maintenance and development of Nuclear Criticality Safety Education Training (NCSET) modules and designing of a new subcritical assembly for hands-on training purposes. This paper provides an overview of the NCSP training and education program. The status of the NCSP hands-on training program will also be provided.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Impact of Irradiation and Decay Time on Chemical Speciation in Uranyl Sulfate Solution

A pH-1, 200-g U/L, highly enriched uranyl sulfate solution was neutron-irradiated using an accelerator-driven neutron source (the Universal Neutron Irradiator, UNI) to fission U-235 under conditions similar to those used by SHINE to produce Mo-99 in a subcritical assembly. We completed a series of five uranyl sulfate irradiations to assess the impact of irradiation and decay time on uranium precipitation and iodine speciation in solution. The duration of each irradiation was increased in order, with the shortest irradiation taking 2.9 hours and the longest, 64.5 hours. A total of 9.5E16 U-235 nuclei were fissioned in all irradiations, and a maximum fission power density of 0.26 W/mL was reached in the final irradiation. We observed no evidence of uranyl peroxide or other precipitates, demonstrating that the addition of Fe 2+ to a final Fe concentration of 200 ppm in the target solution was successful at preventing precipitation under representative irradiation conditions. Nonvolatile I - was found to be the dominant (>70%) iodine species in solution, both immediately after irradiation and after days to weeks of decay time.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

FNCL Enhancements Implementation (FY25 Annual Report)

The FNCL investigations team at Lawrence Livermore National Laboratory (LLNL) has completed research and development of hardware, signal processing, and analysis tools to enhance the measurement capabilities of both the current CAEN SyS VeryFuel Fast Neutron Collar (FNCL) instrument and a next-generation FNCL prototype. The team successfully built and commissioned the LLNL Demonstrator System: a fully integrated, three-panel detector system featuring higher segmentation, plastic scintillators (EJ-276D), Silicon Photomultipliers (SiPMs), no high-voltage requirement, a reduced electronic footprint, and the LLNL-developed Gaussian Mixture Model Pulse Shape Discrimination (GMM-PSD) signal processing. An extensive experimental campaign was conducted at LLNL’s Inherently Safe Subcritical Assembly (ISSA) facility using both the baseline FNCL and the LLNL Demonstrator. The campaign results validated system performance, calibration stability, and the effectiveness of advanced signal processing and analysis algorithms in a relevant environment.

and physical protection↗

MC-Lite: Development of a new lightweight multiplicity counter

This report details the development of a neutron multiplicity counter based on lithium doped plastic scintillators. This system has the capability to measure and discriminate fast neutrons, thermal neutrons, and gamma-rays allowing for multi-particle correlations in one device. The system was built and tested at Lawrence Livermore National Laboratory with Cf-252 in both bare configurations and surrounded by polyethylene and compared against the MC-15 multiplicity counter. Additionally, the detector was also placed outside of a subcritical assembly and demonstrated the ability to use correlated gamma-rays as a probe on the multiplication of the item.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EUCLID Sensitivity Database

This report documents the EUCLID sensitivity database along with its several use-cases. EUCLID computed sensitivities for the following integral responses: Criticality of ICSBEP critical assemblies, LLNL pulsed-sphere neutron-leakage spectra, reaction rates in selected ICBSEP critical assemblies, delayed neutron factions of selected ICSBEP critical assemblies, reactivity coefficients in two ICSBEP critical assemblies, sub-critical assembly responses and Rossi-alpha of selected critical assemblies. It is described for each response what the reported observable constitutes, the method we used to obtain the sensitivities, and which integral experiments were studied. It is also documented briefly in what format these sensitivities are stored. These sensitivities were used for many aspects of the EUCLID project, like ML-supported large-scale nuclear-data validation, or optimization of integral experiments. But these sensitivities can also be applied for more established processes in the nuclear-data application field such as adjustment or assessing the upper sub-critical limit.

Delayed Neutron Fraction↗

NCS Pipeline UC Berkeley Course Overview [Slides]

The criticality safety divisions at Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL), in partnership with Dr. Max Fratoni of UC Berkeley, taught the fourth annual nuclear criticality safety course during the fall 2021 semester at UC Berkeley. This course is part of a larger pipeline project designed to stimulate student interest in the field of criticality safety.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Criticality Safety Pipeline Course - LLNL [Slides]

This presentation details the nuclear criticality safety pipeline course. An educational program from University of California, Berkeley. This course touches on nuclear criticality each fall semester. The curriculum instructs on the fundamentals of criticality safety and provides hands on experience with special nuclear material. This presentation covers lecture topics, project overview, and major criticality safety evaluation projects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗