Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Structured light, Structured illumination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

System for Measuring Flexing of a Large Spaceborne Structure

An optoelectronic metrology system is used for determining the attitude and flexing of a large spaceborne radar antenna or similar structure. The measurements are needed for accurate pointing of the antenna and correction and control of the phase of the radar signal wavefront. The system includes a dual-field-of-view star tracker; a laser ranging unit (LRU) and a position-sensitive-detector (PSD)-based camera mounted on an optical bench; and fiducial targets at various locations on the structure. The fiducial targets are illuminated in sequence by laser light coupled via optical fibers. The LRU and the PSD provide measurements of the position of each fiducial target in a reference frame attached to the optical bench. During routine operation, the star tracker utilizes one field of view and functions conventionally to determine the orientation of the optical bench. During operation in a calibration mode, the star tracker also utilizes its second field of view, which includes stars that are imaged alongside some of the fiducial targets in the PSD; in this mode, the PSD measurements are traceable to star measurements.

Scharf, Daniel↗

Full Field Photoelastic Stress Analysis

A structural specimen coated with or constructed of photoelastic material, when illuminated with circularly polarized light will, when stressed: reflect or transmit elliptically polarized light, the direction of the axes of the ellipse and variation of the elliptically light from illuminating circular light will correspond to and indicate the direction and magnitude of the shear stresses for each illuminated point on the specimen. The principles of this invention allow for several embodiments of stress analyzing apparatus, ranging from those involving multiple rotating optical elements, to those which require no moving parts at all. A simple polariscope may be constructed having two polarizing filters with a single one-quarter waveplate placed between the polarizing filters. Light is projected through the first polarizing filter and the one-quarter waveplate and is reflected from a sub-fringe birefringent coating on a structure under load. Reflected light from the structure is analyzed with a polarizing filter. The two polarizing filters and the one-quarter waveplate may be rotated together or the analyzer alone may be rotated. Computer analysis of the variation in light intensity yields shear stress magnitude and direction.

Lesniak, Jon R.↗

Design and simulation of n -type solar cells based on an iodine-doped CdTe absorber using SCAPS-1D

The performance of conventional p-type CdTe solar cells has plateaued in recent years, motivating exploration of n-type absorbers. Here, we evaluate a homojunction solar cell employing iodine-doped CdTe (CdTe:I) as the absorber in a Ti 3 C 2 T x MXene/p-CdTe:As/n-CdTe:I/indium structure through SCAPS-1D simulations and prototype devices. Optimized simulations predict efficiencies above 25% for thin CdTe:I absorbers (~0.7 μm). In contrast, the first prototype achieved only ~1.36% efficiency with V OC = 0.48 V, J SC = 6.45 mA/cm 2 and FF = 43.8%. When the simulation is adjusted to match the actual device structure, and the effective illumination is reduced to account for front-side light loss, the predicted V OC (0.48 V) and JSC (6.74 mA/cm 2 ) closely reproduce the experimental values. This suggests that the device performance is primarily limited by reduced front-side photon transmission and other material non-idealities. These results highlight the promise of iodine-doped n-type CdTe and identify clear pathways for further efficiency improvement.

14 SOLAR ENERGY↗

Recycling the Energy of Indoor Light: Highly Efficient Organic Photovoltaics via a Ternary Strategy

A ternary approach in organic photovoltaics (OPV) is simple and reliable to effectively tune the optical, electrical and morphological properties of the photoactive layer for high efficiency as well as long-term stability under 1 sun. However, there have been few papers reporting spectra and weak illumination compared to outdoor light. In this study, by using two compatible 16 structures, we demonstrate a simultaneous modulation of light absorption and molecular donor polymers (PM7 and PM7 D1) with slightly-different band gaps and similar chemical packing under ambient conditions, which resulted in efficient indoor OPVs exhibiting power conversion efficiency (PCE) over 20% under 1000 lux of warm white light-emitting diode (2900 K). From morphological analysis, we infer that PM7 serves to seed nucleation of PM7 D1 in the ternary blend, templating its crystallization and alignment along the PM7 backbone. Such templating effect leads to increased domain spacing and relative degree of crystallinity (rDoC) compared to those of each binary system. We further show that higher rDoC helps suppress both bimolecular and trap-assisted recombination of photogenerated charges in the ternary devices. As a result, the complementary absorption and synergistic molecular assembly of the two donor polymers enhance the short-circuit current density as to increase the average PCEs from 9.6 to 10.3% under 1 sun and from 18.7 to 20.0% under 1000 lux. We envision that our strategy of incorporating both a planar and a flexible donor polymer with similar chemical structures can be generally applicable to attain a high performance ternary OPV under both 1 sun and indoor light.

14 SOLAR ENERGY↗

Enhancing Diagnosis through AI-driven Analysis of Reflectance Confocal Microscopy

Reflectance Confocal Microscopy (RCM) is a non-invasive imaging technique used in biomedical research and clinical dermatology. It provides virtual high-resolution images of the skin and superficial tissues, reducing the need for physical biopsies. RCM employs a laser light source to illuminate the tissue, capturing the reflected light to generate detailed images of microscopic structures at various depths. Recent studies explored AI and machine learning, particularly CNNs, for analyzing RCM images. Our study proposes a segmentation strategy based on textural features to identify clinically significant regions, empowering dermatologists in effective image interpretation and boosting diagnostic confidence. This approach promises to advance dermatological diagnosis and treatment.

Yoon, Hong-Jun↗

Two-Photon Fluorescence Microscopy Developed for Microgravity Fluid Physics

Recent research efforts within the Microgravity Fluid Physics Branch of the NASA Glenn Research Center have necessitated the development of a microscope capable of high-resolution, three-dimensional imaging of intracellular structure and tissue morphology. Standard optical microscopy works well for thin samples, but it does not allow the imaging of thick samples because of severe degradation caused by out-of-focus object structure. Confocal microscopy, which is a laser-based scanning microscopy, provides improved three-dimensional imaging and true optical sectioning by excluding the out-of-focus light. However, in confocal microscopy, out-of-focus object structure is still illuminated by the incoming beam, which can lead to substantial photo-bleaching. In addition, confocal microscopy is plagued by limited penetration depth, signal loss due to the presence of a confocal pinhole, and the possibility of live-cell damage. Two-photon microscopy is a novel form of laser-based scanning microscopy that allows three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon microscopy, it utilizes the nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption because of the nonlinear (i.e., quadratic) electric field dependence, so an ultrafast pulsed laser source must typically be employed. On the other hand, this stringent energy density requirement effectively localizes fluorophore excitation to the focal volume. Consequently, two-photon microscopy provides optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction in photo-damage because of the longer excitation wavelength, a reduction in background fluorescence, and a 4 increase in penetration depth over confocal methods because of the reduction in Rayleigh scattering.

Fischer, David G.↗

The Wizard Staff: A Mobile Tool Supporting Human Exploration on The Lunar Surface

The Wizard Staff is a rechargeable, battery powered mobile tool with multiple uses for lunar surface exploration. It supports human activity as a surface survey tool, provides external illumination to enhance safety, delivers networking, communications, and navigation features to remote sites, and assists crew rescue with an emergency beacon and rigid splint structure. As a survey tool, it assists crewed geologic field site exploration with external lights, cameras, and LiDAR to illuminate, map, and record the sample collection process. As a relay station, it provides a surface intranet communications and navigation node for extended exploration far from the lander or habitation module. A separately developed Search-and-Rescue (SAR) handheld device can broadcast a signal to the Gandalf Staff containing crew position and biometric data. The staff then formats the message and sends it orbiting satellite(s) for emergency response via the LunaNET on a dedicated frequency similar to terrestrial applications using an Emergency Position-Indicating Radiobeacon (EPIRB). The staff is designed with an upper and lower segment. Components in the upper segment are the LiDAR, external lighting arrays, cameras, communications equipment, intelligence devices, and user interface for crew operations. The lower segment is a set of FeLiPO4 battery cells packed into the 2” diameter carbon fiber tube. When the battery pack is discharged, a spring connector (designed for the dusty lunar environment) easily disconnects the two segments for replacement with another fully charged battery pack. The lower segment can be used for Incapacitated Crew Rescue (ICR) as a rigid splint. As a stand-alone science platform, the Wizard Staff provides infrastructure for instruments and sensors to record the lunar environment over long periods of time. After a crew installs the components on the lunar surface, the platform delivers data to the lunar lander or base station for analysis. The stand-alone mode requires an auxiliary power source (e.g. solar array) and energy storage system (e.g. battery), so it could also be used as an electrical recharging station. A working prototype of Wizard Staff has been developed with collaboration between NASA (JSC, MSFC, and GSFC), Texas Space Technology Applications and Research (T STAR), and Texas A&M University (TAMU) using $300k of innovation funding in FY’21 and FY’22. The functional staff weights 36# on Earth (6# on the Moon), stands 2.1m tall and delivers external lighting with an array of 40 LED bulbs generating 1460 Lux at 2m range (near field), or 2 Lux at 50m (far field).

Gandalf Staff↗

Role of morphology in defect formation and photo-induced carrier instabilities in amorphous indium oxide

Ab initio molecular dynamics liquid-quench simulations and hybrid density functional calculations are performed to model the effects of room-temperature atomic fluctuations and photo-illumination on the structural and electronic properties of amorphous sub-stoichiometric In 2 O 2.96 . A large configurational ensemble is employed to reliably predict the distribution of localized defects as well as their response to the thermal and light activation. The results reveal that the illumination effects on the carrier concentration are greater in amorphous configurations with shorter In–O bond length and reduced polyhedral sharing as compared to the structures with a more uniform morphology. Further, the obtained correlation between the photo-induced carrier density and the reduction in the number of fully coordinated In-atoms implies that metal oxides with a significant fraction of crystalline/amorphous interfaces would show a more pronounced response to illumination. Photo-excitation also produces In–O 2 –In defects that have not been previously found in sub-stoichiometric amorphous oxides; these defects are responsible for carrier instabilities due to overdoping.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thiol‐Functionalized Conjugated Metal–Organic Frameworks for Stable and Efficient Perovskite Photovoltaics

Abstract Metal–organic frameworks (MOFs) have been investigated recently in perovskite photovoltaics owing to their potential to boost optoelectronic performance and device stability. However, the impact of variations in the MOF side chain on perovskite characteristics and the mechanism of MOF/perovskite film formation remains unclear. In this study, three nanoscale thiol‐functionalized UiO‐66‐type Zr‐based MOFs (UiO‐66‐(SH) 2 , UiO‐66‐MSA, and UiO‐66‐DMSA) are systematically employed and examined in perovskite solar cells (PSCs). Among these MOFs, UiO‐66‐(SH) 2 , with its rigid organic ligands, exhibited a strong interaction with perovskite materials with more efficient suppression of perovskite vacancy defects. More importantly, A detailed and in‐depth discussion is provided on the formation mechanism of UiO‐66‐(SH) 2 ‐assisted perovskite film upon in situ GIWAXS performed during the annealing process. The incorporation of UiO‐66‐(SH) 2 additives substantially facilitates the conversion of PbI 2 into the perovskite phase, prolongs the duration of stage I, and induces a delayed phase transformation pathway. Consequently, the UiO‐66‐(SH) 2 ‐assisted device demonstrates reduced defect density and superior optoelectronic properties with optimized power conversion efficiency of 24.09% and enhanced long‐term stability under ambient environment and continuous light illumination conditions. This study acts as a helpful design guide for desired MOF/perovskite structures, enabling further advancements in MOF/perovskite optoelectronic devices.

14 SOLAR ENERGY↗

Characterization of reflected light from the space power system

Sunlight reflected off large space structures is examined. To assure that this illumination does not exceed the irradiance tolerances of the eye, reflections from these satellites must be controlled by vehicle orientation and surface specifications. The components of various space power system vehicles to determine the reflectances which will significantly contribute to the ground illumination are evaluated. Calculations of reflected solar intensity from various satellite system elements requires description of the elements and of the geometry potential reflectance paths. Surface intensity and the conditions under which it will illuminate a portion of the Earth are also determined.

Liemohn, H. B.↗

Fluorescent Applications to Crystallization

By covalently modifying a subpopulation, less than or equal to 1%, of a macromolecule with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification, and tests with model proteins have shown that labeling u to 5 percent of the protein molecules does not affect the X-ray data quality obtained . The presence of the trace fluorescent label gives a number of advantages. Since the label is covalently attached to the protein molecules, it "tracks" the protein s response to the crystallization conditions. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination crystals show up as bright objects against a darker background. Non-protein structures, such as salt crystals, do not show up under fluorescent illumination. Crystals have the highest protein concentration and are readily observed against less bright precipitated phases, which under white light illumination may obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries as the protein or protein structures is all that shows up. Fluorescence intensity is a faster search parameter, whether visually or by automated methods, than looking for crystalline features. Preliminary tests, using model proteins, indicates that we can use high fluorescence intensity regions, in the absence of clear crystalline features or "hits", as a means for determining potential lead conditions. A working hypothesis is that more rapid amorphous precipitation kinetics may overwhelm and trap more slowly formed ordered assemblies, which subsequently show up as regions of brighter fluorescence intensity. Experiments are now being carried out to test this approach using a wider range, of proteins. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons.

Pusey, Marc L.↗

Analysis of optically controlled microwave/millimeter wave device structures

The light-induced voltage and the change in the source-to-drain channel current under optical illumination higher than the semiconductor bandgap for GaAs MESFET, InP MESFET, Al0.3Ga0.7As/GaAs high electron mobility transistor (HEMT) and GaAs permeable base transistor (PBT) were analytically obtained. The GaAs PBT and GaAs MESFET have much higher sensitivity than InP MESFET. The Al0.3Ga0.7As/GaAs HEMT is observed to have the highest sensitivity. Variation in device parasitics due to optical illumination and its effect on the cutoff frequencies f sub T and f sub max are also investigated.

Simons, R. N.↗

Analysis of optically controlled microwave/millimeter-wave device structures

The light-induced voltage and the change in the source-to-drain channel current under optical illumination higher than the semiconductor bandgap for GaAs MESFET, InP MESFET, Al0.3Ga0.7As/GaAs high electron mobility transistor (HEMT) and GaAs permeable base transistor (PBT) were analytically obtained. The GaAs PBT and GaAs MESFET have much higher sensitivity than InP MESFET. The Al0.3Ga0.7As/GaAs HEMT is observed to have the highest sensitivity. Variation in device parasitics due to optical illumination and its effect on the cutoff frequencies f sub T and f sub max are also investigated.

Simons, Rainee N.↗

Fluorescent Approaches to High Throughput Crystallography

We have shown that by covalently modifying a subpopulation, less than or equal to 1%, of a macromolecule with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification, and the presence of the probe at low concentrations does not affect the X-ray data quality or the crystallization behavior. The presence of the trace fluorescent label gives a number of advantages when used with high throughput crystallizations. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination crystals show up as bright objects against a dark background. Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Brightly fluorescent crystals are readily found against less bright precipitated phases, which under white light illumination may obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries as the protein or protein structures is all that shows up. Fluorescence intensity is a faster search parameter, whether visually or by automated methods, than looking for crystalline features. We are now testing the use of high fluorescence intensity regions, in the absence of clear crystalline features or "hits", as a means for determining potential lead conditions. A working hypothesis is that kinetics leading to non-structured phases may overwhelm and trap more slowly formed ordered assemblies, which subsequently show up as regions of brighter fluorescence intensity. Preliminary experiments with test proteins have resulted in the extraction of a number of crystallization conditions from screening outcomes based solely on the presence of bright fluorescent regions. Subsequent experiments will test this approach using a wider range of proteins. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons.

Pusey, Marc L.↗

Local intensity adaptive image coding

The objective of preprocessing for machine vision is to extract intrinsic target properties. The most important properties ordinarily are structure and reflectance. Illumination in space, however, is a significant problem as the extreme range of light intensity, stretching from deep shadow to highly reflective surfaces in direct sunlight, impairs the effectiveness of standard approaches to machine vision. To overcome this critical constraint, an image coding scheme is being investigated which combines local intensity adaptivity, image enhancement, and data compression. It is very effective under the highly variant illumination that can exist within a single frame or field of view, and it is very robust to noise at low illuminations. Some of the theory and salient features of the coding scheme are reviewed. Its performance is characterized in a simulated space application, the research and development activities are described.

Huck, Friedrich O.↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of a macromolecules purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals will show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "bits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Minamitani, Elizabeth Forsythe↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically can not reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "hits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Pusey, Marc L.↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, 51%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear hits. Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Pusey, Marc L.↗