Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stress test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Accelerated stress testing of terrestrial solar cells

A program to investigate the reliability characteristics of unencapsulated low-cost terrestrial solar cells using accelerated stress testing is described. Reliability (or parametric degradation) factors appropriate to the cell technologies and use conditions were studied and a series of accelerated stress tests was synthesized. An electrical measurement procedure and a data analysis and management system was derived, and stress test fixturing and material flow procedures were set up after consideration was given to the number of cells to be stress tested and measured and the nature of the information to be obtained from the process. Selected results and conclusions are presented.

Prince, J. L.↗

Differential Adaptive Stress Testing of Airborne Collision Avoidance Systems

The next-generation Airborne Collision Avoidance System (ACAS X) is currently being developed and tested to replace the Traffic Alert and Collision Avoidance System (TCAS) as the next international standard for collision avoidance. To validate the safety of the system, stress testing in simulation is one of several approaches for analyzing near mid-air collisions (NMACs). Understanding how NMACs can occur is important for characterizing risk and informingdevelopment of the system. Recently, adaptive stress testing (AST) has been proposed as a way to find the most likely path to a failure event. The simulation-based approach accelerates search by formulating stress testing as a sequential decision process then optimizing it using reinforcement learning. The approach has been successfully applied to stress test a prototype of ACAS Xin various simulated aircraft encounters. In some applications, we are not as interestedin the system's absolute performance as its performance relative to another system. Such situations arise, for example, during regression testing or when deciding whether a new system should replace an existing system. In our collision avoidance application, we are interested in finding cases where ACAS X fails but TCAS succeeds in resolving a conflict. Existing approaches do not provide an efficient means to perform this type of analysis. This paper extends the AST approach to differential analysis by searching two simulators simultaneously and maximizing the difference between their outcomes. We call this approach differential adaptive stress testing (DAST). We apply DAST to compare a prototype of ACAS X against TCAS and show examples of encounters found by the algorithm.

Lee, Ritchie↗

Accelerated Stress Testing of Perovskite Photovoltaic Modules: Differentiating Degradation Modes with Electroluminescence Imaging

Herein, electroluminescence (EL) and thermal imaging are used to examine p–i–n metal halide perovskite (MHP) photovoltaic (PV) mini-modules (MA0.6FA0.4PbI3, 20 cells, 78 cm2) before and after indoor-accelerated stress testing or outdoor deployment. Distinct spatial patterns in the EL images emerge, which depend on the external stress conditions experienced by the mini-module. Imaging results highlight a distribution of dark speckle features that dominate after UV stress, attributed to widespread interfacial contact degradation. Lateral intensity gradients across cells dominate after thermal cycling (TC) stress, attributed to current crowding near scribe defects. While current–voltage analysis alone does not give full insight on the degradation process, this study shows that distinct degradation modes can be further defined by multimodal electro-optical imaging (i.e., EL combined with photoluminescence and dark lock-in thermography). Neither UV exposure nor TC-accelerated stress testing alone replicates the same degradation signatures observed after outdoor deployment, suggesting that multiple degradation modes occur under concurrent stressors outdoors. Finally, spatial characterization of degradation modes in MHP PV mini-modules before and after accelerated stress testing lays the groundwork for developing targeted accelerated stress testing procedures through comparison with outdoor aging.

14 SOLAR ENERGY↗

Electrolyzer Performance Loss from Accelerated Stress Tests and Corresponding Changes to Catalyst Layers and Interfaces

Stress tests are developed for proton exchange membrane electrolyzers that utilize low catalyst loading, elevated potential, and frequent cycling with square- and triangle-waves to accelerate anode catalyst layer degradation during intermittent operation. Kinetics drive performance losses (ohmic/transport secondary) and are accompanied by decreasing exchange current density, decreasing cyclic voltammetric capacitance, and increasing polarization resistance. Decreased kinetics are likely due to a combination of iridium (Ir) migration into electrochemically inaccessible locations in the anode or membrane, Ir particle growth (supported by X-ray scattering), changes in the extent of the Ir oxidation state (supported by X-ray absorption spectroscopy), and anode catalyst layer reordering. Decreasing catalyst/transport layer contact and catalyst/membrane interfacial tearing may add contact resistances and account for increasing ohmic losses. Performance losses for low and moderate catalyst loading, as well as from accelerated and model wind/solar cycling protocols, were likewise dominated by kinetics but vary in severity. Additionally, accelerated cycling (1 cycle per minute) appears to reasonably accelerate relevant loss mechanisms and can be used to project electrolyzer lifetime from anode deterioration. Ongoing accelerated stress test development and studies into performance loss mechanisms will continue to be critical as electrolysis shifts to intermittent power and low-cost applications.

30 DIRECT ENERGY CONVERSION↗

Combined-Accelerated Stress Testing of Photovoltaic Materials

By applying multiple environmental stresses in fieldrepresentative combinations and sequences, combined-accelerated stress testing (CAST) identifies degradation modes and failure mechanisms of photovoltaic (PV) modules and components that are missed by single stress factor accelerated testing.

14 SOLAR ENERGY↗

Acceleration Factors for Combined‐Accelerated Stress Testing of Photovoltaic Modules

Combined‐accelerated stress testing (C‐AST) is developed to establish the durability of photovoltaic (PV) products, including for degradation modes that are not a priori known or examined in standardized tests. C‐AST aims to comprehensively represent the sample, stress factors, and their combinations using levels at the statistical tails of the natural environment. Acceleration factors for relevant climate sequences within the C‐AST cycle with respect to the Florida USA climate are estimated for selected degradation mechanisms. It is found that for degradation of the outer backsheet polymer layer, the acceleration factor of the tropical climate sequence (the longest of the climate sequences) is f ( T , G ) = 17.3 with ultraviolet photodegradation; for polyethylene terephthalate hydrolysis (backsheets), f ( T , RH ) = 426; for electrochemical corrosion (PV cell), f ( I ) = 14.1; and for PbSn solder fatigue f (Δ T , r ( T )) = 17.3. Here, T is the module temperature, G is the broadband spectrum irradiance on the plane of array of the module, RH is the relative humidity on the module surface, I is the leakage current through the module packaging, and r ( T ), the number of temperature reversals. The methods discussed herein are generally applicable for evaluating acceleration factors in other accelerated test methods.

14 SOLAR ENERGY↗

Utilization of stress testing for low-risk patients with chest discomfort in the emergency department

Background: The management of patients presenting to an emergency department with chest discomfort at low-risk for acute coronary syndrome represents a common clinical challenge. Such patients are often triaged to chest pain units for monitoring and cardiac stress testing for further risk stratification. Methods: We conducted a retrospective study of 292 low-risk patients who presented to an emergency department with chest discomfort. We performed physician-adjudicated chart reviews of all patients with positive stress tests to assess downstream testing, subsequent coronary revascularization, and outcomes. Results: Of the 292 patients, 33 (11.3%) had stress tests positive for ischemia, and 12 (4.1%) underwent diagnostic cardiac catheterization. Of the 292 patients, 4 (1.4%) underwent coronary revascularization that may have resulted in a mortality benefit. Conclusion: These data suggest a very low yield of detecting clinically significant coronary disease with stress testing low-risk patients with chest discomfort in emergency department chest pain units.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Polarization Losses under Accelerated Stress Test Using Multiwalled Carbon Nanotube Supported Pt Catalyst in PEM Fuel Cells

The electrochemical behavior for Pt catalysts supported on multiwalled carbon nanotubes and Vulcan XC-72 in proton exchange membrane fuel cells under accelerated stress test was examined by cyclic voltammetry, electrochemical impedance spectroscopy, and polarization technique. Pt catalyst supported on multiwalled carbon nanotubes exhibited highly stable electrochemical surface area, oxygen reduction kinetics, and fuel cell performance at a highly oxidizing condition, indicating multiwalled carbon nanotubes show high corrosion resistance and strong interaction with Pt nanoparticles. The Tafel slope, ohmic resistances, and limiting current density determined were used to differentiate kinetic, ohmic, mass-transfer polarization losses from the actual polarization curve. Kinetic contribution to the total overpotential was larger throughout the stress test. However, the fraction of kinetic overpotential decreased and mass-transfer overpotential portion remained quite constant during accelerated stress test, whereas the fraction of ohmic overpotential primarily originating from severe proton transport limitation in the catalyst layer increased under the anodic potential hold.

30 DIRECT ENERGY CONVERSION↗

Stress Testing of Organic Light- Emitting Diode Panels and Luminaires

This report builds on previous DOE efforts with OLED technology by updating information on a previously benchmarked OLED product (the Chalina luminaire from Acuity Brands) and provides new benchmarks on the performance of Brite 2 and Brite Amber OLED panels from OLEDWorks. During the tests described here, samples of these devices were subjected to continuous operation in stress tests at elevated ambient temperature environments of 35°C or 45°C. In addition, samples were also operated continuously at room temperature in a room temperature operational life test (RTOL). One goal of this study was to investigate whether these test conditions can accelerate failure of OLED panels, either through panel shorting or an open circuit in the panel. These stress tests are shown to provide meaningful acceleration of OLED failure modes, and an acceleration factor of 2.6 was calculated at 45°C for some test conditions. In addition, changes in the photometric properties of the emitted light (e.g., luminous flux and chromaticity maintenance) was also evaluated for insights into the long-term stability of these products compared to earlier generations. Because OLEDs are a lighting system, electrical testing was also performed on the panel-driver pairs to provide insights into the impact of the driver on long-term panel performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing: Preprint

We analyze the degradation of multi-crystalline silicon photovoltaic modules undergoing simultaneous thermal, mechanical, and humidity stress testing to develop a dark environmental chamber in-situ measurement procedure for determining module power loss. From the analysis we determine three main categories of failure modes associated with the module degradation consisting of: shunting, recombination losses, increased series resistance losses, and current mismatch losses associated with a decrease in photo-current generation by removal of some cell areas due to cell fractures. Based on the analysis, we propose an in-situ module power loss monitoring procedure that relies on dark current-voltage measurements taken during the stress test, and initial and final module flash testing, to determine the power degradation characteristic of the module.

14 SOLAR ENERGY↗

Combined-Accelerated Stress Testing for Advanced Reliability Assessment of Photovoltaic Modules

New and previously undiscovered degradation mechanisms continue to be identified after field exposure in new photovoltaic module designs or materials oftentimes results in significant losses in investment. This is despite passing certification tests. Testing is insufficient largely due to their single-or double-stress nature. A Combined-Accelerated Stress Test (C-AST) has recently been developed. The test combines multiple stress factors of the natural environment to better replicate conditions experienced by modules in the field and detect mechanisms not a-priori known in new materials and designs.

accelerator factor modeling↗

Adaptive Stress Testing: Finding Likely Failure Events with Reinforcement Learning

Finding the most likely path to a set of failure states is important to the analysis of safety-critical systems that operate over a sequence of time steps, such as aircraft collision avoidance systems and autonomous cars. In many applications such as autonomous driving, failures cannot be completely eliminated due to the complex stochastic environment in which the system operates.As a result, safety validation is not only concerned about whether a failure can occur, but also discovering which failures are most likely to occur. This article presents adaptive stress testing (AST), a framework for finding the most likely path to a failure event in simulation. We consider a general black box setting for partially observable and continuous-valued systems operating in an environment with stochastic disturbances. We formulate the problem as a Markov decision process and use reinforcement learning to optimize it. The approach is simulation-based and does not require internal knowledge of the system, making it suitable for black-box testing of large systems. We present different formulations depending on whether the state is fully observable or partially observable. In the latter case, we present a modified Monte Carlo tree search algorithm that only requires access to the pseudorandom number generator of the simulator to overcome partial observability. We also present an extension of the framework, called differential adaptive stress testing (DAST), that can find failures that occur in one system but not in another. This type of differential analysis is useful in applications such as regression testing, where we are concerned with finding areas of relative weakness compared to a baseline. We demonstrate the effectiveness of the approach on an aircraft collision avoidance application, where a prototype aircraft collision avoidance system is stress tested to find the most likely scenarios of near mid-air collision.

Verification and Validation↗

In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing

An in-situ method is proposed for monitoring and estimating the power degradation of mc-Si photovoltaic (PV) modules undergoing thermo-mechanical degradation tests that primarily manifest through cell cracking, such as mechanical load tests, thermal cycling and humidity freeze tests. The method is based on in-situ measurement of the module’s dark current-voltage (I-V) characteristic curve during the stress test, as well as initial and final module flash testing on a Sun simulator. The method uses superposition of the dark I-V curve with final flash test module short-circuit current to account for shunt and junction recombination losses, as well as series resistance estimation from the in-situ measured dark I-Vs and final flash test measurements. The method is developed based on mc-Si standard modules undergoing several stages of thermo-mechanical stress testing and degradation, for which we investigate the impact of the degradation on the modules light I-V curve parameters, and equivalent solar cell model parameters. Experimental validation of the method on the modules tested shows good agreement between the in-situ estimated power degradation and the flash test measured power loss of the modules, of up to 4.31 % error (RMSE), as the modules experience primarily junction defect recombination and increased series resistance losses. However, the application of the method will be limited for modules experiencing extensive photo-current degradation or delamination, which are not well reflected in the dark I-V characteristic of the PV module.

14 SOLAR ENERGY↗

Towards Validation of Advanced Accelerated Stress Testing Protocols through Failure Analysis and Materials Characterization

As the lifetime of photovoltaic modules increases toward the goal of 50 years, accelerated stress testing is critical to assessing the viability of newer, improved, and often cheaper materials in the field. However, the validation of accelerated testing to reproduce field failure has remained elusive. The recent developments of more advanced stress testing protocols utilizing sequential and combined stressors have provided another opportunity for validation. Using a suite of mechanical, chemical, and structural characterization methods we report the development of our approach using a known bad backsheet “AAA.” We then apply this approach to PVDF-based backsheets to further confirm the generalizability of this approach. The outcome of this work is two-fold: (1) validation of advanced accelerated testing protocols which will enable the prediction of field failures in new materials, and (2) deeper insights into the degradation mechanisms observed through the extensive characterization allowing for improved materials engineering and development.

accelerated aging↗

Assessment of Accelerated Stress Testing Data for Silicon Photovoltaics Using Tensor Decomposition Methods

The photovoltaic (PV) industry is simultaneously targeting long warranties and new materials/designs for high-energy-yield modules, requiring an advanced methodology to forecast long-term durability of products with un-proven materials combinations. Extended, sequential, and combined stress testing methods are gaining popularity for assessing durability of PV modules/materials beyond the early-stage mortalities. Importantly, multiple degradation mechanisms can proceed simultaneously, and their separate contributions to the overall power loss should ideally be quantified. This work examines the use of data-driven tools towards developing a strategy for faster learning cycles in accelerated stress testing.

accelerated stress testing↗

Assessment of Accelerated Stress Testing Data for Silicon Photovoltaics Using Tensor Decomposition Methods

In this work, we examine the use of high-order tensor decompositions to analyze degradation pathways emerging from accelerated stress testing of silicon photovoltaic (PV) modules. Matrix-based decompositions are powerful tools for studying two-dimensional data arrays and form the foundation of a host of classical data analysis techniques. Tensors are high-order extrapolations of matrices that are able to account for more parameter dimensions, and a variety of tensor decomposition methods have been developed that similarly seek to extend insights from matrix decompositions to higher dimensions. Applying and interpreting tensor decomposition methods to sequences of PV module image data, we seek to uncover and isolate different degradation modes occurring from accelerated stress testing procedures. Further, we consider the contributions of different modes to PV module performance degradations.

data analysis↗

Noninvasive stress testing - Methodology for elimination of the phonocardiogram

Measurement by systolic time intervals (STI) of cardiac responses requires extremely careful recording during actual stress test performance. Previous work indicated no significant changes in the pulse transmission time (PTT) during exercise and other challenges. Since external STI depend on the carotid pulse offset by the PTT as an aortic curve equivalent, stable PTT implies that timing of the carotid upstroke and the carotid incisura would respectively track the pre-ejection period and the aortic incisura. In ten subjects, STIs were recorded at supine rest, sitting, standing, during prompt and sustained squatting and during isometric and dynamic exercise. The results demonstrated the tracking of both points. Coefficients of correlation and of determination were uniformly high for all challenges except isometric handgrip (IHG). Since left ventricular ejection time is obtained directly from the pulse curve, with the exception of IHG, STI responses during stress testing can be measured without a phonocardiogram.

Spodick, D. H.↗