Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Static Electricity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Contamination Control

Upjohn Company sought a solution to their problem of potential particulate contamination of sterile injectable drugs. Contamination was caused by dust particles attracted by static electrical charge, which clung to plastic curtains in clean rooms. Upjohn found guidance in NASA Tech Briefs which provided detailed information for reducing static electricity. Guidelines for setting up static free work stations, materials and equipment needed to maintain antistatic protection.

Source record↗

Analysis of DE-1 PWI electric field data

The measurement of low frequency electric field oscillations may be accomplished with the Plasma Wave Instrument (PWI) on DE 1. Oscillations at a frequency around 1 Hz are below the range of the conventional plasma wave receivers, but they can be detected by using a special processing of the quasi-static electric field data. With this processing it is also possible to determine if the electric field oscillations are predominately parallel or perpendicular to the ambient magnetic field. The quasi-static electric field in the DE 1 spin/orbit plane is measured with a long-wire 'double probe'. This antenna is perpendicular to the satellite spin axis, which in turn is approximately perpendicular to the geomagnetic field in the polar magnetosphere. The electric field data are digitally sampled at a frequency of 16 Hz. The measured electric field signal, which has had phase reversals introduced by the rotating antenna, is multiplied by the sine of the rotation angle between the antenna and the magnetic field. This is called the 'perpendicular' signal. The measured time series is also multiplied with the cosine of the angle to produce a separate 'parallel' signal. These two separate time series are then processed to determine the frequency power spectrum.

Weimer, Daniel↗

Adhesion of Lunar Dust

This paper reviews the physical characteristics of lunar dust and the effects of various fundamental forces acting on dust particles on surfaces in a lunar environment. There are transport forces and adhesion forces after contact. Mechanical forces (i.e., from rover wheels, astronaut boots and rocket engine blast) and static electric effects (from UV photo-ionization and/or tribo-electric charging) are likely to be the major contributors to the transport of dust particles. If fine regolith particles are deposited on a surface, then surface energy-related (e.g., van der Walls) adhesion forces and static-electric-image forces are likely to be the strongest contributors to adhesion. Some measurement techniques are offered to quantify the strength of adhesion forces. And finally some dust removal techniques are discussed.

Walton, Otis R.↗

Chromospheric-coronal coupling during solar flares: Current systems and particle acceleration

Two-dimensional (three velocity) electrostatic particle simulations are used to investigate the particle heating and acceleration associated with the impulsive phase of a solar flare. A crossfield current in the high corona (which is presumably driven by reconnection processes) is used to initiate the flare. Due to the differential motion of the electrons and ions, currents, and associated quasi-static electric fields are generated with the primary current and balancing return current being on adjacent field lines. These currents extend from the corona down into the chromosphere. Electrons can be accelerated to energies exceeding 100 keV on short time scales via the quasi-static fields and wave-particle interactions. The spectra of these electrons has a broken power-law distribution which hardens in time. The spatially separate primary and return currents are closed by the cross-field acceleration of the ambient ions into the primary current regions. These ions are then accelerated upwards into the corona by the same quasi-static electric field accelerating the electrons downwards. This acceleration can account for the broadened stationary and weak blue shifted component seen in soft x ray line emissions and enhancements in heavy ion abundances seen in the solar wind in associations with solar flares.

Winglee, Robert M.↗

Interrelation of soft and hard X-ray emissions during solar flares. II - Simulation model

Two-dimensional electrostatic particle simulations are presented which incorporate the effect of quasi-static electric fields on particle dynamics as well as effects associated with wave-particle interactions induced by the accelerated particles. The properties of the soft and hard X-ray and microwave emissions from such systems are examined. In particular, it is shown that acceleration by quasi-static electric fields and heating via wave-particle interactions produces electron distributions with a broken-power law, similar to those inferred from hard X-ray spectra. Also, heating of the ambient plasma gives rise to a region of hot plasma propagating down to the chromosphere at about the ion sound speed.

Winglee, R. M.↗

Plasma waves observed by the IRM and UKS spacecraft during the AMPTE solar wind lithium releases - Overview

The wave measurements from the Ion Release Module and the United Kingdom Satellite in the diamagnetic cavity, the transition region, and the upstream region are examined. Solar wind conditions during the releases on September 11 and 20, 1984 are described. The quasi-static electric field, wideband, high-frequency waves, and medium and VLF waves observations are analyzed. The data reveal that extremely low levels of wave activity are observed in the boundary between the diamagnetic cavity and external magnetic field, medium and VLF waves in the ion acoustic electrostatic cyclotron harmonic modes are detected in the transition region from the diamagnetic cavity to the solar wind, and decay in the magnetic field strength and density, and an increase in the quasi-static electric field is seen in the upstream edge of the transition region. The emissions observed are related to the different phases of the Li cloud development and different spatial regimes of the Li plasma-solar wind interaction.

Haeusler, B.↗

Observations of electric fields near the plasmapause at midnight

Static electric field measurements in the equatorial-plane from the 100-m double floating probe experiment carried on the SCATHA (P-78-2) satellite are reported. Eclipse measurements on auroral L shells are studied to better understand the change in magnetospheric convection at the plasmapause. The use of eclipse data allows the electric fields to be measured directly without contamination from the spacecraft photoelectron sheath; and it allows the thermal ion population in the outer plasmasphere to be observed, identifying the satellite location with respect to the plasmapause. (Such measurements are limited to near local midnight). It is found that, in the corotating frame, there is generally an electric field component in the antisolar direction during periods of low magnetic activity which begins at the edge of the plasmasphere and builds in amplitude as the satellite enters the plasma sheet. The amplitude of this electric field varies from 0.05 mV/m to 0.2 mV/m with increasing magnetic activity; the electric field switches to radially inward during periods of high activity with magnitudes up to 2 mV/m. The amplitude of the observed electric field increases with the amount of contribution from east-west currents in the earth's plasma sheet-magnetotail current system.

Olsen, R. C.↗

Charge-Dissipative Electrical Cables

Electrical cables that dissipate spurious static electric charges, in addition to performing their main functions of conducting signals, have been developed. These cables are intended for use in trapped-ion or ionizing-radiation environments, in which electric charges tend to accumulate within, and on the surfaces of, dielectric layers of cables. If the charging rate exceeds the dissipation rate, charges can accumulate in excessive amounts, giving rise to high-current discharges that can damage electronic circuitry and/or systems connected to it. The basic idea of design and operation of charge-dissipative electrical cables is to drain spurious charges to ground by use of lossy (slightly electrically conductive) dielectric layers, possibly in conjunction with drain wires and/or drain shields (see figure). In typical cases, the drain wires and/or drain shields could be electrically grounded via the connector assemblies at the ends of the cables, in any of the conventional techniques for grounding signal conductors and signal shields. In some cases, signal shields could double as drain shields.

Kolasinski, John R.↗

Rotationally Vibrating Electric-Field Mill

A proposed instrument for measuring a static electric field would be based partly on a conventional rotating-split-cylinder or rotating-split-sphere electric-field mill. However, the design of the proposed instrument would overcome the difficulty, encountered in conventional rotational field mills, of transferring measurement signals and power via either electrical or fiber-optic rotary couplings that must be aligned and installed in conjunction with rotary bearings. Instead of being made to rotate in one direction at a steady speed as in a conventional rotational field mill, a split-cylinder or split-sphere electrode assembly in the proposed instrument would be set into rotational vibration like that of a metronome. The rotational vibration, synchronized with appropriate rapid electronic switching of electrical connections between electric-current-measuring circuitry and the split-cylinder or split-sphere electrodes, would result in an electrical measurement effect equivalent to that of a conventional rotational field mill. A version of the proposed instrument is described.

Kirkham, Harold↗

Electrically Conductive White Thermal-Control Paint

Report describes development of white thermal-control paint intended for use on spacecraft. Paint required to exhibit combination of high emittance (equal to or greater than 0.90), low absorptance (equal to or less than 0.20), and electrical conductivity sufficient to prevent charging with static electricity to potentials beyond range of plus or minus 10 V.

Hsieh, Cheng-Hsien↗

Large electric fields in the magnetosphere

The Langmuir solitonlike structures which contain plasma frequency oscillations of 500 mV/m and parallel electric fields of about 100 mV/m, observed in the auroral zone below 1000 km, are studied. The characteristics of electrostatic shocks that contain perpendicular fields of 1000 mV/m and parallel fields of 100 mV/m, and of double layers that have parallel fields of 10 mV/m are described. Observations of the geomagnetic tail reveal the presence of 100 mV/m turbulent electric fields and 5-10 mV/m quasi-static fields in the high latitude boundary of the plasma sheet, and inside the plasma sheet fields of 5-10 mV/m are detected. The large amplitude quasi-static electric field fluctuations of 100 mV/m and the dc fields of approximately 5 mV/m observed in the bow shock are examined.

Mozer, F. S.↗

Bubble Formation and Detachment in Reduced Gravity Under the Influence of Electric Fields

The objective of the study is to investigate the behavior of individual air bubbles injected through an orifice into an electrically insulating liquid under the influence of a static electric field. Both uniform and nonuniform electric field configurations were considered. Bubble formation and detachment were recorded and visualized in reduced gravity (corresponding to gravity levels on Mars, on the Moon as well as microgravity) using a high-speed video camera. Bubble volume, dimensions and contact angle at detachment were measured. In addition to the experimental studies, a simple model, predicting bubble characteristics at detachment was developed. The model, based on thermodynamic considerations, accounts for the level of gravity as well as the magnitude of the uniform electric field. Measured data and model predictions show good agreement and indicate that the level of gravity and the electric field magnitude significantly affect bubble shape, volume and dimensions.

Herman, Cila↗

Electric Field Effect on Bubble Detachment in Variable Gravity Environment

The subject of the present study, the process of bubble detachment from an orifice in a plane surface, shows some resemblance to bubble departure in boiling. Because of the high heat transfer coefficients associated with phase change processes, boiling is utilized in many industrial operations and is an attractive solution to cooling problems in aerospace engineering. In terrestrial conditions, buoyancy is responsible for bubble removal from the surface. In space, the gravity level being orders of magnitude smaller than on earth, bubbles formed during boiling remain attached at the surface. As a result, the amount of heat removed from the heated surface can decrease considerably. The use of electric fields is proposed to control bubble behavior and help bubble removal from the surface on which they form. The objective of the study is to investigate the behavior of individual air bubbles injected through an orifice into an electrically insulating liquid under the influence of a static electric field. Bubble cycle life were visualized in terrestrial conditions and for several reduced gravity levels. Bubble volume, dimensions and contact angle at detachment were measured and analyzed for different parameters as gravity level and electric field magnitude. Situations were considered with uniform or non-uni form electric field. Results show that these parameters significantly affect bubble behavior, shape, volume and dimensions.

Iacona, Estelle↗

Bubble Detachment in Variable Gravity Under the Influence of Electric Fields

The objective of the research is to investigate the behavior of individual air bubbles injected through an orifice into an electrically insulating liquid under the influence of a static electric field. Situations were considered with both uniform and nonuniform electric fields. Bubble formation and detachment were visualized in terrestrial gravity as well as for several levels of reduced gravity (lunar, martian and microgravity) using a high-speed video camera. Bubble volume, dimensions and contact angles at detachment were measured. In addition to the experimental studies, a simple model, predicting bubble characteristics at detachment in an initially uniform electric field was developed. The model, based on thermodynamic considerations, accounts for the level of gravity as well as the magnitude of the uniform electric field. The results of the study indicate that the level of gravity and the electric field magnitude significantly affect bubble behavior as well as shape, volume and dimensions.

Herman, Cila↗

On high-latitude convection field inhomogeneities, parallel electric fields and inverted-V precipitation events

A simple model of a static electric field with a component parallel to the magnetic field is proposed for calculating the electric field and current distributions at various altitudes when the horizontal distribution of the convection electric field is given at a certain altitude above the auroral ionosphere. The model is shown to be compatible with satellite observations of inverted-V electron precipitation structures and associated irregularities in the convection electric field.

Lennartsson, W.↗