Transient Stability Analysis of Direct Droop-Controlled Grid-Forming Inverter with Current Clipping as Current Limiting Control

This paper investigates the transient stability of the direct droop-controlled grid-forming (GFM) inverter which employs the current clipping-based approach for overcurrent limitation. An equivalent circuit model of the direct-droop GFM inverter with current clipping is developed for this purpose. It is shown that during overcurrent conditions, the GFM inverter with current clipping acts as a voltage source with a virtual resistance behind the inverter filters. To compute the parameters of this virtual resistance an analytical expression is given in the paper. Then utilizing the developed circuit, a criteria to exit current limiting during post-fault conditions is given. The developed analytical approaches are then validated through electromagnetic transient (EMT) simulation results in PSCAD software and finally concluding remarks are drawn.

Mohiuddin, Sheik Mohammad

Large-signal Stability Analysis of Grid-forming Inverters with Equivalent-circuit Models

Here, this paper proposes an energy function-based direct method for large-signal stability assessment of grid-forming (GFM) inverters leveraging an equivalent-circuit representation of all involved control- and physical-layer dynamics. Three different primary controls, a standard inner-current outer-voltage cascaded-control architecture, output LCL filter, and reference-current saturation limiting are featured in the modeling and analysis framework. A composite energy function for the GFM inverter is obtained by summing up individual energy contributions gleaned from the circuit representation. The approach can readily be generalized to different primary controls, output-filter arrangements, and current limiters since it is based on a circuit-theoretic foundation. Numerical simulations validate the efficacy of the approach in estimating the critical clearing time following a large-signal disturbance.

24 POWER TRANSMISSION AND DISTRIBUTION

Analytical small-signal stability analysis of low-inertia power system frequency response considering secondary frequency regulation

Modern power systems are increasingly vulnerable to frequency instability as inverter-based resources (IBRs) replace synchronous machines and reduce system rotational inertia. Existing small-signal frequency stability assessment methods are either computationally intensive, relying on simulation-driven approaches, or lack analytical stability regions that explicitly account for secondary frequency response (SFR). This paper introduces new analytical frameworks that enable evaluation small-signal frequency stability while explicitly incorporating tunable IBR and SFR parameters. Using Kharitonov’s theorem with an overbounding approach, explicit small-signal stability criteria are derived. In addition, based on Białas’ criterion and Hurwitz matrix, analytical stability regions are established to reveal feasible design spaces for SFR and IBR parameters tuning. Extensive Matlab/Simulink-based simulations validate the accuracy and computational efficiency of the proposed methods, demonstrating that coordinated tuning of SFR and IBR parameters can substantially enhance system resilience. By bridging analytical rigor with practical tunability, this work provides an analytical framework for assessing small-signal frequency stability in low-inertia grids, supporting the real-time, scalable, and resilient operation of sustainable power systems.

14 SOLAR ENERGY

MHD stability analysis against pressure and current-driven modes in the SMall Aspect Ratio Tokamak

Linear magnetohydrodynamic (MHD) simulations for the SMall Aspect Ratio Tokamak (SMART) have been carried out for the first time, for both positive (PT) and negative triangularity (NT) shaped plasmas using the MARS-F code. The MHD stability of projected SMART plasmas against internal kinks, infernal modes and edge peeling-ballooning modes have been analyzed for a wide range of realistic equilibria. A stabilization of internal kinks and infernal modes is observed when increasing the safety factor profile and reducing plasma beta. PT shaped plasmas are more stable against both internal kinks and infernal modes than their counterpart NT shaped plasmas. Toroidal flows have little impact on the MHD stability of the internal kinks, but they have a strong stabilizing effect on infernal modes, which can be further mitigated in NT shaped plasmas. The MHD stability of peeling-ballooning modes is reduced in NT shaped plasmas, as observed in conventional tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Co-Simulation of PSS/E, OpenDSS, and PSCAD for Power Systems Stability Analysis With Inverter-Based Resources: Preprint

The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.

24 POWER TRANSMISSION AND DISTRIBUTION

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters

Advanced grid-forming (GFM) inverter controls, modeling and system impact study for inverter dominated grids

Our main goals in this project are to understand: 1) the stability of the power system with very high penetration of PV or other inverter-based resources (IBR), 2) the interactions among IBRs and traditional generators, and 3) the impact of the GFM inverters on bulk power system. To achieve these goals, we took a holistic research and development approach. First, an impedance-based large system modeling and stability analysis tool was developed to aid the large IBR system small-signal stability analysis. Second, consensus-based control and transient overload ride through were developed to control and coordinate multiple GFM inverters in a large system to maintain transient stability during big grid events. Third, high fidelity electromagnetic transient (EMT) IBR models were developed and integrated into a large reduced WECC model to study the system impact from IBRs. Lastly, extensive validation tests of the GFM control which was developed in this project and implemented in two 1MW commercial solar inverters were performed using different validation platforms, e.g., control hardware-in-the-loop (CHIL) platform, power hardware- in-the-loop (PHIL) platform, and a real PV plant.

14 SOLAR ENERGY

Aeroelastic code comparison using the IEA 22MW reference turbine

Reference wind turbine designs and the associated aeroelastic models are widely used in both research and industry. Reference models representing future concepts are of particular interest. Current state of the art aeroelastic tools are relied upon to design the next generation of large wind turbines. However, modelling assumptions may be invalidated by upcoming very large turbines, and different aeroelastic tools may give inconsistent results. A 22MW turbine model has been defined as part of International Energy Agency (IEA) Wind Task 55 on Reference Wind Turbines and Farms to represent future turbines to be deployed in the 2030s. In this study, an aeroelastic model of this turbine has been created in four tools; Bladed, HAWC2, OpenFAST, and QBlade. Code comparisons are presented for steady state operation, linear stability analysis, and time domain power production simulations in steady and turbulent wind. Generally, the codes show a good agreement, but with some differences present in the linear stability analysis, periodic azimuthal variation, and time domain simulations. The models are a good basis for further study with the IEA 22MW turbine, and further code comparison exercises.

17 WIND ENERGY

Long-term stability-degradation analysis of DUNE SiPMs in Liquid Nitrogen

We developed a cryogenic photon readout system to monitor arrays of DUNE SiPMs operating at various over-voltages in liquid nitrogen (LN2) for over three months. Photoelectron signals were read out simultaneously via weak capacitive coupling to the micro-FEMB, a 32-channel charge sensitive readout board designed for 77 K to 300 K operation in liquid argon time projection chambers (LAr-TPCs). A waveform snippet acquisition scheme was implemented to capture waveform signals whenever they exceeded a predetermined trigger level; consequently, empty waveforms were discarded. Selected SiPM parameters were monitored to detect any deviations beyond statistical fluctuations. While some parameters exhibited ~1σ variations over the 3-month test period, there was no evidence of drift being enhanced when operating at 4 V or 5 V compared to a 3 V over-voltage. However, a discernible PDE drop was observed across all channels, which warrants further investigation. In addition, we demonstrated that our system can simultaneously read out single photons from a selected group of SiPMs at room temperature.

Tsang, Thomas [Brookhaven]

Identification of a window for quiescent H-mode operation in MHD stability diagram of DIII-D plasmas

A window for quiescent H-mode (QH-mode) operation in DIII-D plasmas in the diagram of pedestal magnetohydrodynamic (MHD) stability was identified through linear MHD stability analysis, accounting for the effects of plasma rotation and ion diamagnetic drift. The operation window lies between the stability boundaries of the kink/peeling mode (K/PM) identified with and without the inclusion of plasma rotation effects. In this region, the mode remains unstable unless rotation effects are considered alongside the ion diamagnetic drift, which is consistently included in the analysis. The stabilization of the MHD mode, facilitated by the coupled effects of plasma rotation and ion diamagnetic drift, plays a crucial role in widening the window, enabling the attainment of the QH-mode state. Furthermore, the suppression of edge localized modes (ELM) can be achieved by controlling the pedestal structure to ensure the plasma state remains within the operation window. The location of the operation window in the stability diagram depends on the K/PM stability properties. Therefore, optimizing conditions for QH-mode requires adjustments based on changes in stability characteristics. A pressure pedestal and its associated bootstrap current density near the last closed flux surface are advantageous for situating the plasma state within the window. However, excessive current density can trigger ELMs. This trend was confirmed through comparisons of MHD stability diagrams between QH-mode and ELMy H-mode plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Control Parameter Sensitivity Study for Inverter-Based-Resource Dominated Grids: A Small Signal Stability Approach and Framework

The growing adoption of renewable energy is driving the prevalence of inverter-based resources (IBRs) within power grids. Future power grids will integrate both grid-following IBRs (GFM-IBRs) and grid-forming IBRs (GFL-IBRs) alongside synchronous generators. Therefore, it is crucial to perform stability studies that account for all components and especially control interactions related to IBRs. Extensive research has performed to study the IBR-related stability, however, the sensitivity study of IBRs' control parameters on system stability has not been adequately studied yet, especially from a systematic way. Therefore, this paper conducts a small signal stability analysis for a generic grid with multiple types of resources and develops an analytical framework for assessing the sensitivity of control parameters affecting stability margins. To achieve that, the non-autonomous reduced-order non-linear dynamic model is developed for a generic power system with multiple synchronous generator-based resources (SGBRs), GFM-IBRs, and GFL-IBRs. Based on the analytic model, a systematic framework for parametric sensitivity on systems' asymptotic stability is developed. A parameter sensitivity analysis based on eigenvalue methods is proposed. The impact of the droop controllers of GFM-IBRs, PQ-dispatch and the PLL controller of GFL-IBR on the system asymptotic stability is discussed. This sensitivity study is aiming to provide deep insights on control parameters' impact on system stability, and gives direction for parameter tuning in case of instability.

24 POWER TRANSMISSION AND DISTRIBUTION

Feasibility of an experiment on clumping induced by the Crow instability along a shocked cylinder

The growth of three-dimensional perturbations subject to the Crow instability along a vortex dipole resulting from the passage of a shock wave through a heavy gaseous cylinder is examined numerically. A linear stability analysis is performed based on geometric parameters extracted from two-dimensional simulations to determine the range of unstable wavenumbers, which is found to extend from 0.0 to 1.3 when normalized by the core separation distance. The analysis is then verified by comparison to three-dimensional simulations, which clearly show the development of the instability and the pinch-off of the vortex dipole into isolated vortex rings, which manifest as clumps of the original cylinder material. A scaling law is developed to determine the relevant spatiotemporal scales of the instability development, which is then used to assess the feasibility of a high-energy-density experiment visualizing clump formation. Specifically, a shocked cylinder with an initial diameter of 100 μm consisting of a perturbation of approximate wavelength and amplitude of 600 and 10 μm, respectively, is expected to form clumps resulting from the Crow instability approximately 40 ns after it is shocked, with dynamics which can be readily visualized on the Omega EP laser facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY