Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrum Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

BAYESIAN ANGULAR POWER SPECTRUM ANALYSIS OF INTERFEROMETRIC DATA

We present a Bayesian angular power spectrum and signal map inference engine which can be adapted to interferometric observations of anisotropies in the cosmic microwave background (CMB), 21 cm emission line mapping of galactic brightness fluctuations, or 21 cm absorption line mapping of neutral hydrogen in the dark ages. The method uses Gibbs sampling to generate a sampled representation of the angular power spectrum posterior and the posterior of signal maps given a set of measured visibilities in the uv-plane. We use a mock interferometric CMB observation to demonstrate the validity of this method in the flat-sky approximation when adapted to take into account arbitrary coverage of the uv-plane, mode-mode correlations due to observations on a finite patch, and heteroschedastic visibility errors. The computational requirements scale as O(n{sub p} log n{sub p}) where n{sub p} measures the ratio of the size of the detector array to the inter-detector spacing, meaning that Gibbs sampling is a promising technique for meeting the data analysis requirements of future cosmology missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Full-Spectrum-Analysis Isotope ID

FSAIsotopeID analyzes gamma ray spectra to identify radioactive isotopes (radionuclides). The algorithm fits the entire spectrum with combinations of pre-computed templates for a comprehensive set of radionuclides with varying thicknesses and compositions of shielding materials. The isotope identification algorithm is suitable for the analysis of spectra collected by gamma-ray sensors ranging from medium-resolution detectors, such a NaI, to high-resolution detectors, such as HPGe. In addition to analyzing static measurements, the isotope identification algorithm is applied for the radiation search applications. The search subroutine maintains a running background spectrum that is passed to the isotope identification algorithm, and it also selects temporal integration periods that optimize the responsiveness and sensitivity. Gain stabilization is supported for both types of applications.

Mitchell, Dean J.↗

Neural network-based model of galaxy power spectrum: fast full-shape galaxy power spectrum analysis

ABSTRACT We present a neural network-based emulator for the galaxy redshift-space power spectrum that enables several orders of magnitude acceleration in the galaxy clustering parameter inference, while preserving 3$\sigma$ accuracy better than 0.5 per cent up to $k_{\mathrm{max}}$ = 0.25 $\, h\text{Mpc}^{-1}$ within Lambda-cold dark matter ($\Lambda$CDM) and around 0.5 per cent $w_0$–$w_a$CDM. Our surrogate model only emulates the galaxy bias-invariant terms of one-loop perturbation theory predictions, these terms are then combined analytically with galaxy bias terms, counter-terms, and stochastic terms in order to obtain the non-linear redshift-space galaxy power spectrum. This allows us to avoid any galaxy bias prescription in the training of the emulator, which makes it more flexible. Moreover, we include the redshift $z \in [0,1.4]$ in the training which further avoids the need for re-training the emulator. We showcase the performance of the emulator in recovering the cosmological parameters of $\Lambda$CDM by analysing the suite of 25 AbacusSummit simulations that mimic the Dark Energy Spectroscopic Instrument luminous red galaxies at $z=0.5$ and 0.8, together as the emission line galaxies at $z=0.8$. We obtain similar performance in all cases, demonstrating the reliability of the emulator for any galaxy sample at any redshift in $0 \lt z \lt 1.4$. We will make our emulator public at github repository.

Trusov, Svyatoslav (ORCID:0000000224146720)↗

Power spectrum analysis for defect screening in integrated circuit devices

A device sample is screened for defects using its power spectrum in response to a dynamic stimulus. The device sample receives a time-varying electrical signal. The power spectrum of the device sample is measured at one of the pins of the device sample. A defect in the device sample can be identified based on results of comparing the power spectrum with one or more power spectra of the device that have a known defect status.

30 DIRECT ENERGY CONVERSION↗

Development of a Low-Cost, Sensitivity-Optimized Fluorescence Sensor for Visible Spectrum Analysis

This paper presents an economically viable, sensitivity-optimized fluorescence sensor for detecting low concentrations of fluorophores in the visible spectrum range. The sensor employs a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Instead of utilizing a general-purposed spectrometer optimized for high spectral resolution, the sensor strikes a balance between resolution and sensitivity by using an appropriate aperture size and optimized optical design tailored for the spectral characteristics of fluorophores. Here, the manuscript demonstrates measurements of ppb-level rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions. Through balanced design that optimizes collection of fluorescence emission without losing spectral information, this work shows the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensors with improved detection sensitivity when compared to bench-top commercial spectrofluorometers at far higher costs.

47 OTHER INSTRUMENTATION↗

Comparative Study of Finite Element Methods Using the Time-Accuracy-Size(TAS) Spectrum Analysis

We present a performance analysis appropriate for comparing algorithms using different numerical discretizations. By taking into account the total time-to-solution, numerical accuracy with respect to an error norm, and the computation rate, a cost-benefit analysis can be performed to determine which algorithm and discretization are particularly suited for an application. This work extends the performance spectrum model in for interpretation of hardware and algorithmic tradeoffs in numerical PDE simulation. As a proof-of-concept, popular finite element software packages are used to illustrate this analysis for Poisson’s equation.

97 MATHEMATICS AND COMPUTING↗

Improvement of the edge rotation diagnostic spectrum analysis via simulation

The edge rotation diagnostic (ERD) system has been developed on the Joint Texas Experimental Tokamak to measure the edge toroidal rotation velocity by observing the shifted wavelength of carbon V (C V 227.09 nm). Since the measured spectrum is an integrated result along the viewing line from the plasma core to the edge, a method via simulation has been developed to analyze the ERD spectrum. With the necessary parameters such as C V radiation profile and the ion temperature profile, a local rotation profile at the normalized minor radius of 0.5-1 is obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

21 cm Power Spectrum Analysis of North Celestial Pole Observations with the Tianlai Dish Pathfinder Array

The Tianlai Dish Pathfinder Array (TDPA) is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization Universe as a means of measuring large-scale cosmic structure. Using nine nights of observations targeting the North Celestial Pole field, totaling approximately 107 hr of integration time, we analyze data in the frequency range 700–800 MHz (corresponding to redshift z ∼ 0.9). We do the data format conversion, radio frequency interference flagging, calibration, imaging and point source subtraction, and foreground removal via Singular Value Decomposition. The spherically averaged power spectrum Δ 2 (k) is obtained. Furthermore, this work successfully establishes and validates a comprehensive data analysis framework for the TDPA. We identify key improvements including sky model refinement, increased integration time, and pipeline optimization that will enable future detection of the 21 cm signal through auto-correlation and cross-correlation with optical galaxy surveys.

cosmology: large-scale structure of universe↗

TU-EF-304-09: Quantifying the Biological Effects of Therapeutic Protons by LET Spectrum Analysis

Purpose: To correlate in vitro cell kill with linear energy transfer (LET) spectra using Monte Carlo simulations and knowledge obtained from previous high-throughput in vitro proton relative biological effectiveness (RBE) measurements. Methods: The Monte Carlo simulation toolkit Geant4 was used to design the experimental setups and perform the dose, dose-averaged LET, and LET spectra calculations. The clonogenic assay was performed using the H460 lung cancer cell line in standard 6-well plates. Using two different experimental setups, the same dose and dose-averaged LET (12.6 keV/µm) was delivered to the cell layer; however, each respective energy or LET spectrum was different. We quantified the dose contributions from high-LET (≥10 keV/µm, threshold determined by previous RBE measurements) events in the LET spectra separately for these two setups as 39% and 53%. 8 dose levels with 1 Gy increments were delivered. The photon reference irradiation was performed using 6 MV x-rays from a LINAC. Results: The survival curves showed that both proton irradiations demonstrated an increased RBE compared to the reference photon irradiation. Within the proton-irradiated cells, the setup with 53% dose contribution from high-LET events exhibited the higher biological effectiveness. Conclusion: The experimental results indicate that the dose-averaged LET may not be an appropriate indicator to quantify the biological effects of protons when the LET spectrum is broad enough to contain both low- and high-LET events. Incorporating the LET spectrum distribution into robust intensity-modulated proton therapy optimization planning may provide more accurate biological dose distribution than using the dose-averaged LET. NIH Program Project Grant 2U19CA021239-35.

60 APPLIED LIFE SCIENCES↗

Power spectrum analysis of polarized emission from the Canadian galactic plane survey

Angular power spectra are calculated and presented for the entirety of the Canadian Galactic Plane Survey polarization data set at 1.4 GHz covering an area of 1060 deg{sup 2}. The data analyzed are a combination of data from the 100 m Effelsberg Telescope, the 26 m Telescope at the Dominion Radio Astrophysical Observatory, and the Synthesis Telescope at the Dominion Radio Astrophysical Observatory, allowing all scales to be sampled down to arcminute resolution. The resulting power spectra cover multipoles from ℓ ≈ 60 to ℓ ≈ 10{sup 4} and display both a power-law component at low multipoles and a flattening at high multipoles from point sources. We fit the power spectrum with a model that accounts for these components and instrumental effects. The resulting power-law indices are found to have a mode of 2.3, similar to previous results. However, there are significant regional variations in the index, defying attempts to characterize the emission with a single value. The power-law index is found to increase away from the Galactic plane. A transition from small-scale to large-scale structure is evident at b = 9°, associated with the disk-halo transition in a 15° region around l = 108°. Localized variations in the index are found toward H II regions and supernova remnants, but the interpretation of these variations is inconclusive. The power in the polarized emission is anticorrelated with bright thermal emission (traced by Hα emission) indicating that the thermal emission depolarizes background synchrotron emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Complex multicomponent spectrum analysis with Deep Neural Network

Here, in this paper, we present the use of deep neural networks to estimate physical parameters from complex optical emission spectra of the D β /H β transition. Specifically, we focus on estimating the radio frequency electric field vector of the lower hybrid wave and isotope ratio within the scrape-off-layer plasma of the WEST tokamak. Fitting the spectral data using a traditional non-linear least squares analysis requires many free parameters and is computationally expensive, rendering the data unusable for real-time control. By implementing relatively small neural networks, the physical parameters can be directly extracted from the spectral data with reasonable accuracy in a few milliseconds. The deep neural network prediction can serve as input for a reduced model using least-squares fitting or for real-time control. We show that deep neural networks can be an effective tool for analyzing complex multicomponent spectra, providing a speedup of more than 10 5 times compared to least residual analysis, with an accuracy of 0.5% for the isotope ratio, and 0.09 kV/cm and 0.38 kV/cm for the RF radial and poloidal electric field respectively.

47 OTHER INSTRUMENTATION↗

Adaptive Injection-locking Oscillator Array for RF Spectrum Analysis

A highly parallel radio frequency receiver using an array of injection-locking oscillators for on-chip, rapid estimation of signal amplitudes and frequencies is considered. The oscillators are tuned to different natural frequencies, and variable gain amplifiers are used to provide negative feedback to adapt the locking band-width with the input signal to yield a combined measure of input signal amplitude and frequency detuning. To further this effort, an array of 16 two-stage differential ring oscillators and 16 Gilbert-cell mixers is designed for 40-400 MHz operation. The injection-locking oscillator array is assembled on a custom printed-circuit board. Control and calibration is achieved by on-board microcontroller.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Monte Carlo based lookup table for spectrum analysis of turbid media in the reflectance probe regime

Fibre-optic diffuse reflectance spectroscopy offers a method for characterising phantoms of biotissue with specified optical properties. For a commercial reflectance probe (six source fibres surrounding a central collection fibre with an inter-fibre spacing of 480 μm; R400-7, Ocean Optics, USA) we have constructed a Monte Carlo based lookup table to create a function called getR(μ{sub a}, μ'{sub s}), where μ{sub a} is the absorption coefficient and μ'{sub s} is the reduced scattering coefficient. Experimental measurements of reflectance from homogeneous calibrated phantoms with given optical properties are compared with the predicted reflectance from the lookup table. The deviation between experiment and prediction is on average 12.1%. (laser biophotonics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multifrequency spectrum analysis using fully digital G Mode-Kelvin probe force microscopy

Since its inception over two decades ago, Kelvin probe force microscopy (KPFM) has become the standard technique for characterizing electrostatic, electrochemical and electronic properties at the nanoscale. In this work, we present a purely digital, software-based approach to KPFM utilizing big data acquisition and analysis methods. General Mode (G-Mode) KPFM, works by capturing the entire photodetector data stream, typically at the sampling rate limit, followed by subsequent de-noising, analysis and compression of the cantilever response. We demonstrate that the G-Mode approach allows simultaneous multi-harmonic detection, combined with on-the-fly transfer function correction required for quantitative CPD mapping. The KPFM approach outlined in this work significantly simplifies the technique by avoiding cumbersome instrumentation optimization steps (i.e. lock in parameters, feedback gains etc.), while also retaining the flexibility to be implemented on any atomic force microscopy platform. We demonstrate the added advantages of G-Mode KPFM by allowing simultaneous mapping of CPD and capacitance gradient (C') channels as well as increased flexibility in data exploration across frequency, time, space, and noise domains. As a result, G-Mode KPFM is particularly suitable for characterizing voltage sensitive materials or for operation in conductive electrolytes, and will be useful for probing electrodynamics in photovoltaics, liquids and ionic conductors.

36 MATERIALS SCIENCE↗

The Simons Observatory: impact of bandpass, polarization angle and calibration uncertainties on small-scale power spectrum analysis

We study the effects due to mismatches in passbands, polarization angles, and temperature and polarization calibrations in the context of the upcoming cosmic microwave background experiment Simons Observatory (SO). Using the SO multi-frequency likelihood, we estimate the bias and the degradation of constraining power in cosmological and astrophysical foreground parameters assuming different levels of knowledge of the instrumental effects. We find that incorrect but reasonable assumptions about the values ofall the systematics examined here can have significant effects on cosmologicalanalyses, hence requiring marginalization approaches at the likelihood level.When doing so, we find that the most relevant effect is due to bandpass shifts. When marginalizing over them, the posteriors of parameters describing astrophysical microwave foregrounds (such as radio point sources or dust) get degraded, while cosmological parameters constraints are not significantly affected.Marginalization over polarization angles with up to 0.25$^{°}$ uncertainty causes an irrelevant bias ≲ 0.05 σ in all parameters.Marginalization over calibration factors in polarization broadens the constraints on the effective number of relativistic degrees of freedom N$_{eff}$ by a factor 1.2, interpreted here as a proxy parameter for non standard model physics targeted by high-resolution CMB measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗