Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrum Analysis, Raman”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Raman spectroscopic investigation of UCl 4

Uranium chloride salts are a proposed fuel source for molten salt reactors (MSRs). However, despite their relevance to nuclear energy, they remain understudied, in part because of their air and moisture sensitivity. Here, this work provides the first Raman spectra of UCl 4 from 45 to 3200 cm −1 collected with 532 and 785 nm excitation sources as well as the assignment of 10 identified peaks to their respective vibrational modes. These Raman bands are compared to those for isostructural ThCl 4 , the compositionally related UCl 3 , and the computed Raman bands for UCl 4 from local vibrational mode analysis. The observed spectrum of UCl 4 is in accord with that of ThCl 4 and the computed spectra of UCl 4 . We posit that the observed differences between the spectra of UCl 4 and UCl 3 are useful in differentiating these species for applications such as in situ monitoring of MSR operations.

Anoxic spectroscopy↗

Determination of the temperature of gas mixtures by using laser Raman scattering

A theoretical model for the Raman rotational spectrum of air was formulated, yielding the spectral temperature dependence; and an error analysis of temperature measurement accuracies was performed. The theoretical spectra and the predicted temperature measurement error of + or - 20 K (7 percent) compared well with experimental data. These experimental data consisted of Raman spectra of air obtained for temperatures ranging from 243 to 313 K at a pressure of 1 atmosphere. The use of selected lines resulted in an experimental accuracy of + or - 13 K (-5 percent).

Coney, T. A.↗

Raman spectroscopic investigation of ianthinite [U$_2^{4+}$(UO$_2$)$_4$O$_6$(OH)$_4$(H$_2$O)$_4$]·$5$H$_2$O, a rare mixed-valence uranium oxide hydrate

Ianthinite ([[U$_2^{4+}$(UO$_2$)$_4$O$_6$(OH)$_4$(H$_2$O)$_4$]·$5$H$_2$O) is an exotic mineral that possesses U in both tetravalent and hexavalent oxidation states and is structurally related to the U 3 O 8 polymorphs, which are commonly encountered technogenic materials in the nuclear fuel cycle. Despite the similarities between U 3 O 8 and ianthinite, and the importance of ianthinite in U paragenesis, no Raman spectra have been reported for this mineral. Here, to gain a more complete understanding of how structural attributes of ianthinite give rise to observable spectroscopic features and how these may relate to important materials in the nuclear fuel cycle, we provide, for the first time, Raman spectra of ianthinite. Ianthinite readily oxidizes at ambient conditions, complicating analysis of phase-pure material. Several analytical methods are employed herein to decouple the Raman features of ianthinite from its alteration product(s). First, a simple difference spectrum is presented, then results of Raman spectroscopic mapping are employed, and finally, we use a novel processing and analysis method. Each analysis method provides different insight into structural features that are unique to ianthinite, in particular, features that are attributable to U(IV) in distorted octahedral coordination in both ianthinite and U 3 O 8 phases.

Spano, Tyler L. [Oak Ridge National Laboratory (OR↗

In Site Analysis of a High Temperature Cure Reaction in Real Time Using Modulated Fiber-Optic FT-Raman Spectroscopy

The vibrational spectrum of a high temperature (330 C) polymerization reaction was successfully monitored in real time using a modulated fiber-optic FT-Raman spectrometer. A phenylethynyl terminated monomer was cured, and spectral evidence for two different reaction products was acquired. The products are a conjugated polyene chain and a cyclized trimer. This is the first report describing the use of FT-Raman spectroscopy to monitor a high temperature (greater than 250 C) reaction in real time.

Cooper, John↗

In Situ Analysis of a High-Temperature Cure Reaction in Real Time Using Modulated Fiber-Optic FT-Raman Spectroscopy

The vibrational spectrum of a high-temperature (330 C) polymerization reaction was successfully monitored in real time with the use of a modulated fiber-optic Fourier transform (FT)-Raman spectrometer. A phenylethynyl-terminated monomer was cured, and spectral evidence for two different reaction products was acquired. The products are a conjugated polyene chain and a cyclized trimer. This is the first report describing the use of FT-Raman spectroscopy to monitor a high temperature (greater than 250 C) reaction in real time.

Aust, Jeffrey F.↗

An Investigation of Oxides of Tantalum Produced by Pulsed Laser Ablation and Continuous Wave Laser Heating

Recent progress has seen multiple Ta 2 O 5 polymorphs generated by different synthesis techniques. However, discrepancies arise when these polymorphs are produced in widely varying thermodynamic conditions and characterized using different techniques. This work aimed to characterize and compare Ta 2 O 5 particles formed at high and low temperatures using nanosecond pulsed laser ablation (PLA) and continuous wave (CW) laser heating of a local area of tantalum in either air or an 18 O 2 atmosphere. Scanning electron microscopy (SEM) and Raman spectroscopy of the micrometer-sized particles generated by PLA were consistent with either a localized amorphous Ta 2 O 5 phase or a similar, but not identical, crystalline β-Ta 2 O 5 phase. The Raman spectrum of the material formed at the point of CW laser impingement was in good agreement with the previously established ceramic “H-Ta 2 O 5 ” phase. TEM and electron diffraction analysis of these particles indicated the phase structure matched an oxygen-vacated superstructure of monoclinic H-Ta 2 O 5 . Further from the point of laser impingement, CW heating produced particles with a Raman spectrum that matched β-Ta 2 O 5 . We confirmed that the high-temperature ceramic phase characterized in previous work by Raman spectroscopy was the same monoclinic phase characterized in different work by TEM and could be produced by direct laser heating of metal in air.

36 MATERIALS SCIENCE↗

Chemical and spectroscopic characterization of plutonium tetrafluoride

Anhydrous plutonium tetrafluoride is an important intermediate in the production of metallic Pu. This historically important compound is also known to exist in at least two distinct, yet understudied hydrate forms, PuF 4 ·xH 2 O(s) (0.5 ≤ x ≤ 2) and PuF 4 ·2.5H 2 O(s). X-ray diffraction (XRD), thermogravimetric analysis (TGA), and scanning electron microscopy (SEM) are the most common tools used to characterize these materials, often in a context for studying structural and morphological changes that arise from aging or calcination. However, fundamental electronic and vibrational spectroscopic information is rather scarce. Here, in this study, we measured the visible and shortwave infrared (SWIR) diffuse reflectance, Fourier transform infrared (FTIR), fluorescence and Raman spectra of PuF 4 (s) and PuF 4 ·xH 2 O(s) to obtain a better electronic and vibrational fingerprint. Our work provides clear indication of the polymeric structure of anhydrous PuF 4 , consistent with the Raman spectrum of UF 4 (s) and its hydrates. This is supplemented with XRD, TGA and SEM analysis. Findings in this study indicate that the spectra are modified by particle size, which in turn is influenced by synthetic technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polycyclic aromatic hydrocarbons and the unidentified infrared emission bands - Auto exhaust along the Milky Way

The unidentified infrared emission features (UIR bands) are attributed to a collection of partially hydrogenated, positively charged polycyclic aromatic hydrocarbons (PAHs). This assignment is based on a spectroscopic analysis of the UIR bands. Comparison of the observed interstellar 6.2 and 7.7-micron bands with the laboratory measured Raman spectrum of a collection of carbon-based particulates (auto exhaust) shows a very good agreement, supporting this identification. The infrared emission is due to relaxation from highly vibrationally and electronically excited states. The excitation is probably caused by UV photon absorption. The infrared fluorescence of one particular, highly vibrationally excited PAH (chrysene) is modeled. In this analysis the species is treated as a molecule rather than bulk material and the non-thermodynamic equilibrium nature of the emission is fully taken into account. From a comparison of the observed ratio of the 3.3 to 11.3-micron UIR bands with the model calculations, the average number of carbon atoms per molecule is estimated to be about 20. The abundance of interstellar PAHs is calculated to be about 2 x 10 to the -7th with respect to hydrogen.

Allamandola, L. J.↗

Structure and phase transitions in niobium and tantalum derived nanoscale transition metal perovskites, Ba(Ti,MV)O3, M=Nb,Ta

The prospect of creating ferroelectric or high permittivity nanomaterials provides motivation for investigating complex transition metal oxides of the form Ba(Ti, MV)O3, where M = Nb or Ta. Solid state processing typically produces mixtures of crystalline phases, rarely beyond minimally doped Nb/Ta. Using a modified sol-gel method, we prepared single phase nanocrystals of Ba(Ti, M)O3. Compositional and elemental analysis puts the empirical formulas close to BaTi0.5Nb0.5O3−δ and BaTi0.5Ta0.5O3−δ. For both materials, a reversible temperature dependent phase transition (non-centrosymmetric to symmetric) is observed in the Raman spectrum in the region 533–583 K (260–310 °C); for Ba(Ti, Nb)O3, the onset is at 543 K (270 °C); and for Ba(Ti, Ta)O3, the onset is at 533 K (260 °C), which are comparable with 390–393 K (117–120 °C) for bulk BaTiO3. The crystal structure was resolved by examination of the powder x-ray diffraction and atomic pair distribution function (PDF) analysis of synchrotron total scattering data. It was postulated whether the structure adopted at the nanoscale was single or double perovskite. Double perovskites (A2B′B″O6) are characterized by the type and extent of cation ordering, which gives rise to higher symmetry crystal structures. PDF analysis was used to examine all likely candidate structures and to look for evidence of higher symmetry. The feasible phase space that evolves includes the ordered double perovskite structure Ba2(Ti, MV)O6 (M = Nb, Ta) Fm-3m, a disordered cubic structure, as a suitable high temperature analog, Ba(Ti, MV)O3Pm-3m, and an orthorhombic Ba(Ti, MV)O3Amm2, a room temperature structure that presents an unusually high level of lattice displacement, possibly due to octahedral tilting, and indication of a highly polarized crystal.

Chemistry↗

Quantitative Analysis of Spectral Interference of Spontaneous Raman Scattering in High-Pressure Fuel-Rich H2-Air Combustion

We present a theoretical study of the spectral interferences in the spontaneous Raman scattering spectra of major combustion products in 30-atm fuel-rich hydrogen-air flames. An effective methodology is introduced to choose an appropriate line-shape model for simulating Raman spectra in high-pressure combustion environments. The Voigt profile with the additive approximation assumption was found to provide a reasonable model of the spectral line shape for the present analysis. The rotational/vibrational Raman spectra of H2, N2, and H2O were calculated using an anharmonic-oscillator model using the latest collisional broadening coefficients. The calculated spectra were validated with data obtained in a 10-atm fuel-rich H2-air flame and showed excellent agreement. Our quantitative spectral analysis for equivalence ratios ranging from 1.5 to 5.0 revealed substantial amounts of spectral cross-talk between the rotational H2 lines and the N2 O-/Q-branch; and between the vibrational H2O(0,3) line and the vibrational H2O spectrum. We also address the temperature dependence of the spectral cross-talk and extend our analysis to include a cross-talk compensation technique that removes the nterference arising from the H2 Raman spectra onto the N2, or H2O spectra.

Kojima, Jun↗

The effects of thickness, polarization, and strain on vibrational modes of 2D Fe 3 GeTe 2

In this study, we investigated the effects of thickness, light polarization, and strain on the Raman spectra of two-dimensional (2D) Fe 3 GeTe 2 (FGT) crystals synthesized via chemical vapor transport. The crystals are thoroughly characterized using a combination of microscopic, diffraction, and spectroscopic techniques. Particularly, a systematic angle-resolved polarized Raman spectroscopy study reveals a clear polarization dependence of the Raman intensity in both parallel and crossed polarization directions, with the $A$$^{1}_{g}$ mode completely disappearing in the crossed polarization direction. The angle-dependent intensity of both the $A$$^{1}_{g}$ and $E$$^{2}_{2g}$ modes in parallel polarization and the intensity of the $E$$^{2}_{2g}$ mode in the crossed polarization remain constant at all angles. These findings align with predictions from Raman tensor analysis, providing compelling evidence for the unambiguous assignment of the $A$$^{1}_{g}$ and $E$$^{2}_{2g}$ modes to specific peaks observed in the Raman spectrum of FGT, resolving existing confusion in the literature regarding their assignment. Furthermore, we examine the effect of strain on the Raman spectrum of 2D FGT in-situ using a bending device. Our study, conducted on a monolayer to few-layer 2D FGT deposited onto polyethylene terephthalate and subjected to outward (inward), i.e., tensile (compressive) bending, demonstrates appreciable downshifting (upshifting) of the Raman peak position of both $A$$^{1}_{g}$ and $E$$^{2}_{2g}$ modes. Furthermore, these findings are particularly significant given that strain engineering represents an effective approach to modulate the magnetic properties of FGT and other 2D magnetic materials.

2D materials↗

Non-invasive glucose monitor

A non-invasive method for determining blood level of an analyte of interest, such as glucose, comprises: generating an excitation laser beam (e.g., at a wavelength of 700 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of an eye of the subject so that aqueous humor in the anterior chamber is illuminated; detecting (preferably confocally detecting) a Raman spectrum from the illuminated aqueous humor; and then determining the blood glucose level (or the level of another analyte of interest) for the subject from the Raman spectrum. Preferably, the detecting step is followed by the step of subtracting a confounding fluorescence spectrum from the Raman spectrum to produce a difference spectrum; and determining the blood level of the analyte of interest for the subject from that difference spectrum, preferably using linear or nonlinear multivariate analysis such as partial least squares analysis. Apparatus for carrying out the foregoing method is also disclosed.

Lambert, James L.↗

Low-Resolution Raman-Spectroscopy Combustion Thermometry

A method of optical thermometry, now undergoing development, involves low-resolution measurement of the spectrum of spontaneous Raman scattering (SRS) from N2 and O2 molecules. The method is especially suitable for measuring temperatures in high pressure combustion environments that contain N2, O2, or N2/O2 mixtures (including air). Methods based on SRS (in which scattered light is shifted in wavelength by amounts that depend on vibrational and rotational energy levels of laser-illuminated molecules) have been popular means of probing flames because they are almost the only methods that provide spatially and temporally resolved concentrations and temperatures of multiple molecular species in turbulent combustion. The present SRS-based method differs from prior SRS-based methods that have various drawbacks, a description of which would exceed the scope of this article. Two main differences between this and prior SRS-based methods are that it involves analysis in the frequency (equivalently, wavelength) domain, in contradistinction to analysis in the intensity domain in prior methods; and it involves low-resolution measurement of what amounts to predominantly the rotational Raman spectra of N2 and O2, in contradistinction to higher-resolution measurement of the vibrational Raman spectrum of N2 only in prior methods.

Nguyen, Quang-Viet↗

The far ultraviolet reflection spectrum of Uranus - Results from the Voyager encounter

The present analysis of the 1250-1700 A region Uranus spectrum obtained by Voyager's US spectrometer characterizes these observation results as due primarily to solar light reflected from an H2 Rayleigh and Raman scattering atmosphere with small but measurable hydrocarbon absorption. The hydrocarbon abundances obtained are substantially lower than those at comparable levels of the Saturn or Jupiter atmospheres; it is suggested, in one-dimensional terms, that this is due to diffusive separation, in conjunction with photochemical depletion caused by a very low eddy-diffusion coefficient. Strong latitudinal variations in the hydrocarbon abundances are suggested in the subsolar, polar stratosphere.

Yelle, Roger V.↗

Small Business Innovations

Under a Small Business Innovation Research (SBIR) contract to Kennedy Space Center, EIC Laboratories invented a Raman Spectrograph with fiber optic sampling for space applications such as sensing hazardous fuel vapors and making on-board rapid analyses of chemicals and minerals. Raman spectroscopy is a laser-based measurement technique that provides through a unique vibrational spectrum a molecular 'fingerprint,' and can function in aqueous environments. EIC combined optical fiber technology with Raman methods to develop sensors that can be operated at a distance from the spectrographic analysis instruments and the laser excitation source. EIC refined and commercialized the technology to create the Fiber Optic Raman Spectrograph and the RamanProbe. Commercial applications range from process control to monitoring hazardous materials.

Source record↗

Assessing blood brain barrier dynamics or identifying or measuring selected substances or toxins in a subject by analyzing Raman spectrum signals of selected regions in the eye

A non-invasive method for analyzing the blood-brain barrier includes obtaining a Raman spectrum of a selected portion of the eye and monitoring the Raman spectrum to ascertain a change to the dynamics of the blood brain barrier. Also, non-invasive methods for determining the brain or blood level of an analyte of interest, such as glucose, drugs, alcohol, poisons, and the like, comprises: generating an excitation laser beam (e.g., at a wavelength of 600 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of an eye of the subject so that aqueous humor, vitreous humor, or one or more conjunctiva vessels in the eye is illuminated; detecting (preferably confocally detecting) a Raman spectrum from the illuminated portion of the eye; and then determining the blood level or brain level (intracranial or cerebral spinal fluid level) of an analyte of interest for the subject from the Raman spectrum. In certain embodiments, the detecting step may be followed by the step of subtracting a confounding fluorescence spectrum from the Raman spectrum to produce a difference spectrum; and determining the blood level and/or brain level of the analyte of interest for the subject from that difference spectrum, preferably using linear or nonlinear multivariate analysis such as partial least squares analysis. Apparatus for carrying out the foregoing methods are also disclosed.

Lambert, James L.↗

Assessing blood brain barrier dynamics or identifying or measuring selected substances, including ethanol or toxins, in a subject by analyzing Raman spectrum signals

A non-invasive method for analyzing the blood-brain barrier includes obtaining a Raman spectrum of a selected portion of the eye and monitoring the Raman spectrum to ascertain a change to the dynamics of the blood brain barrier.Also, non-invasive methods for determining the brain or blood level of an analyte of interest, such as glucose, drugs, alcohol, poisons, and the like, comprises: generating an excitation laser beam at a selected wavelength (e.g., at a wavelength of about 400 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of an eye of the subject so that aqueous humor, vitreous humor, or one or more conjunctiva vessels in the eye is illuminated; detecting (preferably confocally detecting) a Raman spectrum from the illuminated portion of the eye; and then determining the blood level or brain level (intracranial or cerebral spinal fluid level) of an analyte of interest for the subject from the Raman spectrum. In certain embodiments, the detecting step may be followed by the step of subtracting a confounding fluorescence spectrum from the Raman spectrum to produce a difference spectrum; and determining the blood level and/or brain level of the analyte of interest for the subject from that difference spectrum, preferably using linear or nonlinear multivariate analysis such as partial least squares analysis. Apparatus for carrying out the foregoing methods are also disclosed.

Lambert, James L.↗

Rayleigh, Raman and particulate scattering

Analysis of the visible and near infrared spectra of planetary atmospheres and the multiple scattering of photons within the atmosphere are discussed. Photons detected within the spectral region are solar photons which were scattered by the gas and particles in the planetary atmosphere. An example is given for the incident and emitted fluxes for a hypothetical planet with an effective temperature of 100 K. The absorption spectrum of the planetary atmosphere is discussed in terms of the various scattering processes photons undergo within the atmosphere. Three different physical processes are considered. Rayleigh scattering and Raman scattering by the gas molecules, and scattering by any cloud or dust aerosol particles in the atmosphere. The physics of each of these processes is examined.

Cochran, W. D.↗