Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) spectrometer design and performance

The development of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) has been completed at JPL. This paper outlines the functional requirements of the spectrometer optics subsystem, and describes the spectrometer optical design. The optical subsystem performance is shown in terms of spectral modulation transfer functions, radial energy distributions, and system transmission at selected wavelengths for the four spectrometers. An outline of the spectrometer alignment is included.

Macenka, Steven A.↗

High-resolution grazing-incidence grating spectrometer for temperature measurements of low-Z ions emitting in the 100–300 Å spectral band

We have constructed a high-resolution grazing-incidence spectrometer designed for measuring the ion temperature of low-Z elements, such as Li{sup +} or Li{sup 2+}, which radiate near 199 Å and 135 Å, respectively. Based on measurements at the Livermore Electron Beam Ion Trap we have shown that the instrumental resolution is better than 48 mÅ at the 200 Å setting and better than 40 mÅ for the 135-Å range. Such a high spectral resolution corresponds to an instrumental limit for line-width based temperature measurements of about 45 eV for the 199 Å Li{sup +} and 65 eV for the 135 Å Li{sup 2+} lines. Recently obtained survey spectra from the Lithium Tokamak Experiment at the Princeton Plasma Physics Laboratory show the presence of these lithium emission lines and the expected core ion temperature of approximately 70 eV is sufficiently high to demonstrate the feasibility of utilizing our high-resolution spectrometer as an ion-temperature diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A split imaging spectrometer for temporally and spatially resolved titanium absorption spectroscopy

We present a temporally and a spatially resolved spectrometer for titanium x-ray absorption spectroscopy along 2 axial symmetric lines-of-sight. Each line-of-sight of the instrument uses an elliptical crystal to acquire both the 2p and 3p Ti absorption lines on a single, time gated channel of the instrument. The 2 axial symmetric lines-of-sight allow the 2p and 3p absorption features to be measured through the same point in space using both channels of the instrument. The spatially dependent material temperature can be inferred by observing the 2p and the 3p Ti absorption features. The data are recorded on a two strip framing camera with each strip collecting data from a single line-of-sight. The design is compatible for use at both the OMEGA laser and the National Ignition Facility. The spectrometer is intended to measure the material temperature behind a Marshak wave in a radiatively driven SiO{sub 2} foam with a Ti foam tracer. In this configuration, a broad band CsI backlighter will be used for a source and the Ti absorption spectrum measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended-range grazing-incidence spectrometer for high-resolution extreme ultraviolet measurements on an electron beam ion trap

A high-resolution grazing-incidence grating spectrometer has been implemented on the Livermore electron beam ion traps for performing very high-resolution measurements in the soft x-ray and extreme ultraviolet region spanning from below 10 Å to above 300 Å. The instrument operates without an entrance slit and focuses the light emitted by highly charged ions located in the roughly 50 μm wide electron beam onto a cryogenically cooled back-illuminated charge-coupled device detector. The measured line widths are below 0.025 Å above 100 Å, and the resolving power appears to be limited by the source size and Doppler broadening of the trapped ions. Comparisons with spectra obtained with existing grating spectrometers show an order of magnitude improvement in spectral resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lineshape spectroscopy with a very high resolution, very high signal-to-noise crystal spectrometer

We have developed a high-resolution x-ray spectrometer for measuring the shapes of spectral lines produced from laser-irradiated targets on the Orion laser facility. The instrument utilizes a spherically bent crystal geometry to spatially focus and spectrally analyze photons from foil or microdot targets. The high photon collection efficiency resulting from its imaging properties allows the instrument to be mounted outside the Orion chamber, where it is far less sensitive to particles, hard x-rays, or electromagnetic pulses than instruments housed close to the target chamber center in ten-inch manipulators. Moreover, Bragg angles above 50° are possible, which provide greatly improved spectral resolution compared to radially viewing, near grazing-incidence crystal spectrometers. These properties make the new instrument an ideal lineshape diagnostic for determining plasma temperature and density. We describe its calibration on the Livermore electron beam ion trap facility and present spectral data of the K-shell emission from highly charged sulfur produced by long-pulse as well as short-pulse beams on the Orion laser in the United Kingdom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The magnetic recoil spectrometer (MRSt) for time-resolved measurements of the neutron spectrum at the National Ignition Facility (NIF)

The next-generation magnetic recoil spectrometer for time-resolved measurements of the neutron spectrum has been conceptually designed for the National Ignition Facility. This spectrometer, called MRSt, represents a paradigm shift in our thinking about neutron spectrometry for inertial confinement fusion applications, as it will provide simultaneously information about the burn history and time evolution of areal density (ρR), apparent ion temperature (T{sub i}), yield (Y{sub n}), and macroscopic flows during burn. From this type of data, an assessment of the evolution of the fuel assembly, hotspot, and alpha heating can be made. According to simulations, the MRSt will provide accurate data with a time resolution of ∼20 ps and energy resolution of ∼100 keV for total neutron yields above ∼10{sup 16}. At lower yields, the diagnostic will be operated at a higher-efficiency, lower-energy-resolution mode to provide a time resolution of ∼20 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated Silicon Fourier Transform Spectrometer with Broad Bandwidth and Ultra‐High Resolution

An ultra-high resolution Fourier transform spectrometer (FTS) realized in silicon photonic platform that can operate with broad band, narrow band as well as a combination of broad band and narrow band signals is reported. The ultra-high resolution of the spectrometer is achieved by exploiting multiple techniques: a Michelson interferometer (MI) structure to increase the optical path delay (OPD), a hybrid waveguide design to reduce insertion loss, an optimized heater and air trenches to achieve higher thermal efficiency. Here, to further increase the OPD of the spectrometer to increase its resolution, a novel multiple interferometers approach is employed which combines balanced MI with N statically imbalanced MIs, thereby increasing the OPD of a single MI by factor of N + 1. An FTS spectrometer consisting of N = 2 such MIs is fabricated and experimentally characterized using unknown broad bandwidth input signal spectra of about 180 nm centered around 1550 nm, a narrow line laser input signal, and a combination of broad and narrow band signals demonstrating spectral resolution of about 0.16 nm.

Li, Ang↗

The Simulation and Design of an On-Chip Superconducting Millimetre Filter-Bank Spectrometer

Abstract Superconducting on-chip filter banks provide a scalable, space saving solution to create imaging spectrometers at millimetre and submillimetre wavelengths. We present an easy to realise, lithographed superconducting filter design with a high tolerance to fabrication error. Using a capacitively coupled $$\lambda /2$$ λ / 2 microstrip resonator to define a narrow ( $$\lambda /\Delta \lambda = 300$$ λ / Δ λ = 300 ) spectral pass band, the filtered output of a given spectrometer channel directly connects to a lumped-element kinetic inductance detector. We show the tolerance analysis of our design, demonstrating $$<11\%$$ < 11 % change in filter quality factor to any one realistic fabrication error and a full filter-bank efficiency forecast to be 50% after accounting for fabrication errors and dielectric loss tangent.

Robson, G. (ORCID:0000000315279326)↗

Modular Total Absorption Spectrometer at the HRIBF (ORNL, Oak Ridge)

The Modular Total Absorption Spectrometer (MTAS) array has been designed, constructed, characterized, and applied to the decay studies of {sup 238}U fission products at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory. A MTAS commissioning run was performed in January 2012 at the mass separator on-line to the HRIBF Tandem accelerator. Preliminary results of MTAS data confirm known decay patterns of {sup 142}Ba and {sup 142}La deduced from an earlier study using a total absorption spectrometer technique.

43 PARTICLE ACCELERATORS↗

Special Nuclear Material Characterization Using Digital 3-D Position Sensitive CdZnTe Detectors and High Purity Germanium Spectrometers

Special nuclear material (SNM) monitoring often requires high resolution gamma-ray spectroscopy for material characterization. Portable systems and rapid deployment are also highly valued for some applications. Deployable gamma-ray imaging spectrometers using pixelated CdZnTe semiconductor detectors have become commercially available within the past three years to meet these requirements. CdZnTe systems have demonstrated room-temperature energy resolutions below 0.5% FWHM at 662 keV using single pixel events and below 0.7% FWHM at 662 keV using all events. The systems are able to go from storage to measurement in less than two minutes. Special nuclear materials were measured at the Y-12 National Security Complex and at the Device Assembly Facility at the Nevada National Security Site. The use of a CdZnTe system to measure uranium enrichment was demonstrated and uranium spectral features were compared to a commercially available high purity germanium (HPGe) spectrometer. The use of passive gamma ray spectroscopy techniques to estimate plutonium grade using CdZnTe detectors was demonstrated for the first time.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

Design of the opacity spectrometer for opacity measurements at the National Ignition Facility

Recent experiments at the Sandia National Laboratory Z facility have called into question models used in calculating opacity, of importance for modeling stellar interiors. An effort is being made to reproduce these results at the National Ignition Facility (NIF). These experiments require a new X-ray opacity spectrometer (OpSpec) spanning 540 eV–2100 eV with a resolving power E/ΔE > 700. The design of the OpSpec is presented. Photometric calculations based on expected opacity data are also presented in this paper. First use on NIF is expected in September 2016.

47 OTHER INSTRUMENTATION↗

Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector

Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time. C-CAMMS also incorporates a miniature carbon nanotube (CNT) field emission electron ionization source and a capacitive transimpedance amplifier (CTIA) ion array detector. Results confirm the cycloidal mass analyzer’s compatibility with aperture coding. A >10× increase in throughput was achieved without loss of resolution compared with a single slit instrument. Several areas where additional improvement can be realized are identified. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

University of Lodz an electron spectrometer—A new conversion-electron spectrometer for “in-beam” measurements

The designed and constructed at the University of Lodz an electron spectrometer is devoted to “in-beam” measurements. The apparatus is characterized by high efficiency up to 9%, good energy resolution (FWHM = 5 keV at 482 keV) and, what is very important good suppression of delta electrons, positrons, and photons emitted by the targets. This achievement was obtained using a combination of magnetic field in two different layouts: perpendicular and parallel to the axis of the spectrometer being orthogonal to the beamline. The conversion-electron spectrometer coupled to the EAGLE array was successfully tested in an “in-beam” measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and characterization of the time-resolved opacity spectrometer (OpSpecTR) for the NIF iron opacity campaign

A new time-resolved opacity spectrometer (OpSpecTR) is currently under development for the National Ignition Facility (NIF) opacity campaign. Here, the spectrometer utilizes Icarus version 2 (IV2) hybridized complementary metal–oxide–semiconductor sensors to collect gated data at the time of the opacity transmission signal, unlocking the ability to collect higher-temperature measurements on NIF. Experimental conditions to achieve higher temperatures are feasible; however, backgrounds will dominate the data collected by the current time-integrating opacity spectrometer. The shortest available OpSpecTR integration time of ~2 ns is predicted to reduce self-emission and other late-time backgrounds by up to 80%. Initially, three Icarus sensors will be used to collect data in the self-emission, backlighter, and absorption regions of the transmission spectrum, with plans to upgrade to five Daedalus sensors in future implementations with integration times of ~1.3 ns. We present the details of the diagnostic design along with recent characterization results of the IV2 sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and characterization of the flight model spectrometer onboard LuSEE-Night

The Lunar Surface Electromagnetics Experiment - Night, LuSEE-Night, is a low-frequency radio astronomy experiment that will explore the cosmic Dark Ages signal on the radio-quiet far side of the Moon. Here, the LuSEE-Night carries a radio frequency spectrometer consisting of a set of antennas, analog and digital processing electronics, and will be launched by NASA’s Commercial Lunar Payload Services in 2025. The spectrometer is designed to observe the spectrum of the radio sky in the 0.5-50MHz band. The flight model (FM) of the four-channel spectrometer has been developed. The FM has been characterized for linearity, gain, noise, and their temperature dependence, confirming that the FM meets all the requirements for LuSEE-Night.

47 OTHER INSTRUMENTATION↗

Calibration of scintillation-light filters for neutron time-of-flight spectrometers at the National Ignition Facility

Sixty-four neutral density filters constructed of metal plates with 88 apertures of varying diameter have been radiographed with a soft x-ray source and CCD camera at National Security Technologies, Livermore. An analysis of the radiographs fits the radial dependence of the apertures’ image intensities to sigmoid functions, which can describe the rapidly decreasing intensity towards the apertures’ edges. The fitted image intensities determine the relative attenuation value of each filter. Absolute attenuation values of several imaged filters, measured in situ during calibration experiments, normalize the relative quantities which are now used in analyses of neutron spectrometer data at the National Ignition Facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving a high-efficiency, gated spectrometer for x-ray Thomson scattering experiments at the National Ignition Facility

We are developing x-ray Thomson scattering for applications in implosion experiments at the National Ignition Facility. In particular we have designed and fielded MACS, a high-efficiency, gated x-ray spectrometer at 7.5–10 keV [T. Döppner et al., Rev. Sci. Instrum. 85, 11D617 (2014)]. Here we report on two new Bragg crystals based on Highly Oriented Pyrolytic Graphite (HOPG), a flat crystal and a dual-section cylindrically curved crystal. We have performed in situ calibration measurements using a brass foil target, and we used the flat HOPG crystal to measure Mo K-shell emission at 18 keV in 2nd order diffraction. Such high photon energy line emission will be required to penetrate and probe ultra-high-density plasmas or plasmas of mid-Z elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗