Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral mixture analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Near-IR laser-based spectrophotometer for comparative analysis of isotope content of CO{sub 2} in exhale air samples

We present a laser spectrophotometer aimed at high-accuracy comparative analysis of content of {sup 12}CO{sub 2} and {sup 13}CO{sub 2} isotope modifications in the exhale air samples and based on a tunable near-IR diode laser (2.05 {mu}m). The two-channel optical scheme of the spectrophotometer and the special digital system for its control are described. An algorithm of spectral data processing aimed at determining the difference in the isotope composition of gas mixtures is proposed. A few spectral regions (near 4880 cm{sup -1}) are determined to be optimal for analysis of relative content of {sup 12}CO{sub 2} and {sup 13}CO{sub 2} in the exhale air. The use of the proposed spectrophotometer scheme and the developed algorithm makes the results of the analysis less susceptible to the influence of the interference in optical elements, to the absorption in the open atmosphere, to the slow drift of the laser pulse envelope, and to the offset of optical channels. The sensitivity of the comparative analysis of the isotope content of CO{sub 2} in exhale air samples, achieved using the proposed scheme, is estimated to be nearly 0.1 Per-Mille-Sign .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determining Reactor Fuel Type from Continuous Antineutrino Monitoring

In this work, we investigate the ability of an antineutrino detector to determine the fuel type of a reactor. A hypothetical 5-ton antineutrino detector is placed 25 m from the core and measures the spectral shape and rate of antineutrinos emitted by fission fragments in the core for a number of 90-d periods. Our results indicate that four major fuel types can be differentiated from the variation of fission fractions over the irradiation time with a true positive probability of detection at approximately 95%. In addition, we demonstrate that antineutrinos can identify the burnup at which weapons-grade mixed-oxide (MOX) fuel would be reduced to reactor-grade MOX, on average, providing assurance that plutonium-disposition goals are met. We also investigate removal scenarios where plutonium is purposefully diverted from a mixture of MOX and low-enriched uranium fuel. Lastly, we discuss how our analysis is impacted by a spectral distortion around 6 MeV observed in the antineutrino spectrum measured from commercial power reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

X-ray Spectral Analysis for Void Fraction Measurement

X-ray attenuation technique has been widely used in two-phase flow measurement. In general, an x-ray system measures the overall attenuation of the two-phase mixture existing between an x-ray source and a detector. One can obtain the void fraction from the intensity of the attenuated x-ray beam and known attenuation coefficients of each phase. Fig. 1 shows a schematic of the line detector system developed at Virginia Tech, and the reconstructed image of a sample slug bubble. The system is capable of obtaining high-resolution (100 {mu}m or less) x-ray images of two-phase flow at a frame rate exceeding 1000 Hz. Note that the intensity of the image can be converted into the line-averaged void fraction data measured by each detector pixel. Typical x-ray systems do not resolve the energy spectrum. Instead, they only measure the total energy deposited in the detector during the exposure period. However, the x-ray source generated from x-ray tubes present polychromatic characteristics. The attenuation coefficient and detector efficiency strongly depend on the energy of x-ray photons. In relation to this, this paper presents the spectral characteristics of a typical x-ray system used for void fraction measurement in two-phase flows. The photon-energy-dependent efficiency of the detector is determined by a calibration test. (authors)

42 ENGINEERING↗

Molecular detection of per- and polyfluoroalkyl substances in water using time-of-flight secondary ion mass spectrometry

Detection of per- and polyfluoroalkyl substances (PFASs) is crucial in environmental mitigation and remediation of these persistent pollutants. We demonstrate that time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a viable technique to analyze and identify these substances at parts per trillion (ppt) level in real field samples without complicated sample preparation due to its superior surface sensitivity. Several representative PFAS compounds, such as perfluorooctanesulfonic acid (PFOS), perfluorobutanoic acid (PFBA), perfluoropentanoic acid (PFPeA), perfluoheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA), and real-world groundwater samples collected from monitoring wells installed around at a municipal wastewater treatment plant located in Southern California were analyzed in this work. ToF-SIMS spectral comparison depicts sensitive identification of pseudo-molecular ions, characteristic of reference PFASs. Additionally, principal component analysis (PCA) shows clear discrimination among real samples and reference compounds. Our results show that characteristic molecular ion and fragments peaks can be used to identify PFASs. Furthermore, SIMS two-dimensional (2D) images directly exhibit the distribution of perfluorocarboxylic acid (PFCA) and PFOS in simulated mixtures and real wastewater samples. Such findings indicate that ToF-SIMS is useable to determine PFAS compounds in complex environmental water samples. In conclusion, ToF-SIMS provides simple sample preparation and high sensitivity in mass spectral imaging, offering an alternative solution for environmental forensic analysis of PFASs in wastewater in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PCP METHODOLOGY FOR DETERMINING DOSE RATES FOR SMALL GRAM QUANTITIES IN SHIPPING PACKAGINGS

The Small Gram Quantity (SGQ) concept is based on the understanding that small amounts of hazardous materials, in this case radioactive materials, are significantly less hazardous than large amounts of the same materials. This study describes a methodology designed to estimate an SGQ for several neutron and gamma emitting isotopes that can be shipped in a package compliant with 10 CFR Part 71 external radiation level limits regulations. These regulations require packaging for the shipment of radioactive materials perform, under both normal and accident conditions, the essential functions of material containment, subcriticality, and maintain external radiation levels within regulatory limits. 10 CFR 71.33(b)(1)(2)&(3) state radioactive and fissile materials must be identified and their maximum quantity, chemical and physical forms be included in an application. Furthermore, the U.S. Federal Regulations require application contain an evaluation demonstrating the package (i.e., the packaging and its contents) satisfies the external radiation standards for all packages (10 CFR 71.31(2), 71.35(a), & 71.47). By placing the contents in a He leak-tight containment vessel, and limiting the mass to ensure subcriticality, the first two essential functions are readily met. Some isotopes emit sufficiently strong photon radiation that small amounts of material can yield a large external dose rate. Quantifying of the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. The Packaging Certification Program (PCP) Methodology for Determining Dose Rate for Small Gram Quantities in Shipping Packagings described in this report provides bounding mass limits for a set of proposed SGQ isotopes. Methodology calculations were performed to estimate external radiation levels for the 9977 shipping package using the MCNP radiation transport code to develop a set of response multipliers (Green's functions) for 'dose per particle' for each neutron and photon spectral group. The source spectrum for each isotope generated using the ORIGEN-S and RASTA computer codes was folded with the response multipliers to generate the dose rate per gram of each isotope in the 9977 shipping package and its associated shielded containers. The maximum amount of a single isotope that could be shipped within the regulatory limits contained in 10 CFR 71.47 for dose rate at the surface of the package is determined. If a package contains a mixture of isotopes, the acceptability for shipment can be determined by a sum of fractions approach. Furthermore, the results of this analysis can be easily extended to additional radioisotopes by simply evaluating the neutron and/or photon spectra of those isotopes and folding the spectral data with the Green's functions provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine Learning-Based Classification of Lignocellulosic Biomass from Pyrolysis-Molecular Beam Mass Spectrometry Data

High-throughput analysis of biomass is necessary to ensure consistent and uniform feedstocks for agricultural and bioenergy applications and is needed to inform genomics and systems biology models. Pyrolysis followed by mass spectrometry such as molecular beam mass spectrometry (py-MBMS) analyses are becoming increasingly popular for the rapid analysis of biomass cell wall composition and typically require the use of different data analysis tools depending on the need and application. Here, the authors report the py-MBMS analysis of several types of lignocellulosic biomass to gain an understanding of spectral patterns and variation with associated biomass composition and use machine learning approaches to classify, differentiate, and predict biomass types on the basis of py-MBMS spectra. Py-MBMS spectra were also corrected for instrumental variance using generalized linear modeling (GLM) based on the use of select ions relative abundances as spike-in controls. Machine learning classification algorithms e.g., random forest, k-nearest neighbor, decision tree, Gaussian Naïve Bayes, gradient boosting, and multilayer perceptron classifiers were used. The k-nearest neighbors (k-NN) classifier generally performed the best for classifications using raw spectral data, and the decision tree classifier performed the worst. After normalization of spectra to account for instrumental variance, all the classifiers had comparable and generally acceptable performance for predicting the biomass types, although the k-NN and decision tree classifiers were not as accurate for prediction of specific sample types. Gaussian Naïve Bayes (GNB) and extreme gradient boosting (XGB) classifiers performed better than the k-NN and the decision tree classifiers for the prediction of biomass mixtures. The data analysis workflow reported here could be applied and extended for comparison of biomass samples of varying types, species, phenotypes, and/or genotypes or subjected to different treatments, environments, etc. to further elucidate the sources of spectral variance, patterns, and to infer compositional information based on spectral analysis, particularly for analysis of data without a priori knowledge of the feedstock composition or identity.

59 BASIC BIOLOGICAL SCIENCES↗

Chemical variability in mineralized veins observed by ChemCam on the lower slopes of Mount Sharp in Gale crater, Mars

ChemCam has observed a wide range of diagenetic features along the Curiosity rover traverse including pervasive Ca-sulfate veins. Observations by multiple instruments on Curiosity indicate that these veins are hydrated, formed during diagenetic fluid event(s). In this study, we delve into the chemical variability in these Ca-sulfate bearing veins and have identified two subsets in the Murray formation with enrichments in Fe and Fe + Mg. These chemical trends do not reflect a sampling mixture with the surrounding host rock but likely indicates the presence of authigenic phases formed during the emplacement of these veins. Based on passive reflectance spectral analysis and correlation with other elements, Fe 3+ oxides and/or sulfates are proposed to account for the Fe-rich observations in the vicinity of the Naukluft Plateau whereas the Fe + Mg trend is also observed in adjacent dark-toned features with elevated Mn and P near the Old Soaker outcrop. In conclusion, the specific localization of these observations in the Gale stratigraphy implies changing pH and redox conditions in the groundwater at the time of formation of these veins, from oxidizing and likely more acidic near the Naukluft Plateau to more reducing conditions in the upper part of the Murray formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-CD-206-01: Expectation-Maximization Algorithm-Based Tissue Mixture Quantification for Perfusion MRI

Purpose: To investigate the feasibility of estimating the tissue mixture perfusions and quantifying cerebral blood flow change in arterial spin labeled (ASL) perfusion MR images. Methods: The proposed perfusion MR image analysis framework consists of 5 steps: (1) Inhomogeneity correction was performed on the T1- and T2-weighted images, which are available for each studied perfusion MR dataset. (2) We used the publicly available FSL toolbox to strip off the non-brain structures from the T1- and T2-weighted MR images. (3) We applied a multi-spectral tissue-mixture segmentation algorithm on both T1- and T2-structural MR images to roughly estimate the fraction of each tissue type - white matter, grey matter and cerebral spinal fluid inside each image voxel. (4) The distributions of the three tissue types or tissue mixture across the structural image array are down-sampled and mapped onto the ASL voxel array via a co-registration operation. (5) The presented 4-dimensional expectation-maximization (4D-EM) algorithm takes the down-sampled three tissue type distributions on perfusion image data to generate the perfusion mean, variance and percentage images for each tissue type of interest. Results: Experimental results on three volunteer datasets demonstrated that the multi-spectral tissue-mixture segmentation algorithm was effective to initialize tissue mixtures from T1- and T2-weighted MR images. Compared with the conventional ASL image processing toolbox, the proposed 4D-EM algorithm not only generated comparable perfusion mean images, but also produced perfusion variance and percentage images, which the ASL toolbox cannot obtain. It is observed that the perfusion contribution percentages may not be the same as the corresponding tissue mixture volume fractions estimated in the structural images. Conclusion: A specific application to brain ASL images showed that the presented perfusion image analysis method is promising for detecting subtle changes in tissue perfusions, which is valuable for the early diagnosis of certain brain diseases, e.g. multiple sclerosis.

60 APPLIED LIFE SCIENCES↗

Higher-Order Mass Defect Analysis for Mass Spectra of Complex Organic Mixtures

Higher-order mass defect analysis is introduced as a unique formula assignment and visualization method for the analysis of complex mass spectra. This approach is an extension of the concepts of Kendrick mass transformation widely used for identification of homologous compounds differing only by a number of base units (e.g., CH2, H2, O, CH2O, etc.) in complex mixtures. We present an iterative renormalization routine for defining higher order homologous series and multidimensional clustering of mass spectral features. This approach greatly simplifies visualization of complex mass spectra and increases the number of chemical formulae that can be confidently assigned for given mass accuracy. The potential for using higher-order mass defects for data reduction and visualization is shown. Higher-order mass defect analysis is described and demonstrated through third-order analysis of a de-isotoped high-resolution mass spectrum of crude oil containing nearly 13,000 peaks.

02 PETROLEUM↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

Multi-Gas Sensors for Enhanced Reliability of SOFC Operation

GE Research, in partnership with SUNY Polytechnic Institute (SUNY Poly), designed, built, and tested gas sensors for in situ monitoring of H 2 and CO anode tail gases produced with on-site steam reforming in solid oxide fuel cell (SOFC) systems. The knowledge of the H 2 /CO ratio of these anode tail gases should allow accurate determination and control of the efficiency of the reforming process in the SOFC system and should deliver a lower operating cost for SOFC customers. The project objectives were to achieve multi-gas monitoring capability with a single multivariable sensor, and to sustain this performance in the presence of gaseous interferences and a potential poison for the sensor. The duration of the project was 24 months with the project structure that included three technical tasks such as (1) development of design rules of photonic nanostructures for H 2 and CO gas detection, (2) laboratory validation of photonic nanostructures for selective H 2 and CO gas detection, and (3) validation of photonic nanostructures for initial stability and poison-resistance against H 2 S. To build multivariable sensors for selective H 2 and CO gas detection in the presence of interferences, we expanded our earlier knowledge of multi-gas sensors into new fabrication and functionalization methodologies as well as into new methodologies for the spectral data analysis of multi-gas responses. We have advanced our design rules of the three-dimensional (3D) photonic nanostructures that allowed detection of H 2 and CO at high temperatures as individual gases and as their mixtures and rejection of interferences such as CO 2 , H 2 O, CH 4 , and other hydrocarbons for SOFC applications. Our advanced design rules should be attractive for building the new generation of cost-effective industrial sensors. Stability and poison resistance of our 3D photonic nanostructures was tested in the laboratory conditions. While initially we utilized conventional machine learning data analysis tools, we have found that they were unable to correct for the sensor drift. Thus, we have implemented new methods of machine learning for the analysis of our spectral data. These learnings pave the way to move the future studies into advanced testing of effects of interferences, aging and field tests. In future, our work will continue to advance our sensing designs to operate in conditions with known and unknown interferences by implementing nanostructures with enhanced spectral diversity of responses to gaseous species of interest and interferences. Our systematic reduction of technical risks in this completed project and in future studies will ensure transition of this sensing technology to commercialization.

03 NATURAL GAS↗

A METHODOLOGY FOR DETERMINING THE DOSE RATE FOR BOUNDING MASS LIMITS IN A 9977 PACKAGING

The Small Gram Quantity (SGQ) concept is based on the understanding that the hazards associated with the shipment of a radioactive material are directly proportional to its mass. This study describes a methodology that estimates the acceptable masses for several neutron and gamma emitting isotopes that can be shipped in a 9977 Package compliant with the Title 10 of the Code of Federal Regulations, Part 71 (10CFR71) external radiation level limits. 10CFR71.33 states that a shipping application identifies the radioactive and fissile materials at their maximum quantity and provides an evaluation demonstrating compliance with the external radiation standards. Since rather small amounts of some isotopes emit sufficiently strong radiation to produce a large external dose rate, quantifying of the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. A methodology was established for determining the dose rate for bounding mass limits for a set of isotopes in the Model 9977 Shipping Package. Calculations were performed to estimate external radiation levels using the MCNP radiation transport code to develop a set of response multipliers (Green's functions) for 'dose per source particle' for each neutron and photon spectral group. The source spectrum from one gram of each isotope was folded with the response multipliers to generate the dose rate per gram of each isotope in the 9977 shipping package and its associated shielded containers. The maximum amount of a single isotope that could be shipped within the regulatory limits for dose rate at the surface was determined. For a package containing a mixture of isotopes, the acceptability for shipment can be determined by a sum of fractions approach. Furthermore, the results of this analysis can be easily extended to additional radioisotopes by simply evaluating the neutron and/or photon spectra of those isotopes and folding the spectral data with the Green's functions provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantitative analysis of Cu XANES spectra using linear combination fitting of binary mixtures simulated by FEFF9

We report x-ray absorption near edge structure (XANES) is a powerful tool to probe the fingerprint of local structures, and when coupled with X-ray microscopy, the small spot size enables one to probe very specific regions of interest in a device or material, e.g. interfaces/bulk, different grains, good/bad electrical areas. In this work, we investigate the use of linear combination fitting (LCF) of XANES spectra for the particular case of Cu doping in CdTe. We show that the experimental data seem to be accurately represented by standards of Cu 2 Te and its substoichiometric counterpart, Cu 1.43 Te. We use Cu in CdTe as a case study to evaluate the accuracy of linear combination fitting using simulated standards, given that experimental standards for certain phases (e.g. Cu 1.43 Te) or defect structures (e.g. vacancies) cannot be readily obtained. We discuss how spectral features of the FEFF9-simulated standards, fitting ranges, and noise levels all dictate the accuracy of this type of analysis. We show that the greater the spectral difference between the two standards, the better the LCF is able to differentiate between the two structures and to tolerate experimental noise. Finally, we estimate the error of the fitted weights for different spectral features and noise levels and propose a framework to study local structures semi-quantitatively by using binary mixtures of FEFF9-simulated standards.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the origin of the two-component structure of broad-line region by reverberation mapping of an extremely variable quasar

ABSTRACT The physical origins of quasar components, such as the broad-line region (BLR) and dust torus, remain under debate. To gain insights into them, we focused on changing-state quasars (CSQs) which provide a unique perspective through structural changes associated with accretion disc state transitions. We targeted SDSS J125809.31+351943.0, an extremely variable CSQ, to study its central core structure and kinematics. We conducted reverberation mapping with optical spectroscopy to explore the structure of the BLR and estimate the black hole mass. The results from Hβ reverberation mapping indicated a black hole mass of $10^{9.64^{+0.11}_{-0.20}}\rm {M_\odot }$. Additionally, we analysed variations in the optical to X-ray spectral indices, αox, before and after the state transition, to investigate the accretion disc. These variations in αox and the Eddington ratio (from 0.4 per cent to 2.4 per cent) exhibitied behaviour similar to state transitions observed in X-ray binary systems. Spectral analysis of Hβ revealed a predominantly double-peaked profile during dim periods, transitioning to include a single-peaked component as the quasar brightened, suggesting that Hβ contains a mixture of two components. Each of these components has its distinct characteristics: the first is a double-peaked profile that remains stable despite changes in the accretion rate, while the second is a variable single-peaked profile. Using time-lags from reverberation mapping, we estimated the spatial relationships between these BLR components, the accretion disc, and the dust torus. Our results suggest that the BLR consists of two distinct components, each differing in location and origin.

Nagoshi, Shumpei (ORCID:0000000326504322)↗

FTIR Spectral Components of Schwertmannite

Fourier transform infrared (FTIR) spectral components of three dominant groups of sulfate species in synthetic schwertmannite (Fe8O8(OH)6-x(SO4)x ·nH2O) are presented. Thesecomponentswereextractedbymultivariatecurveresolution analysis of spectra obtained from N2(g)-dry samples initially reacted in aqueous solutions (pH 3-9) at room temperature. Each component contains complex sets of bands that correspond to mixtures of similar species. We tentatively assign these components to sulfate ions that are hydrogen- (components I and III) and iron-bonded (component I) to schwertmannite. Another component (II) is assigned to protonated sulfate species. Heating experiments to 130 °C moreover confirmed this possibility for component II. The spectral components extracted from this study can be used to identify dominant sulfate species in FTIR spectra of naturally occurring schwertmannite samples.

08 HYDROGEN↗

Comparing Top-Down Proteoform Identification: Deconvolution, PrSM Overlap, and PTM Detection

Generating top-down tandem mass spectra (MS/MS) for complex mixtures of proteoforms has become possible through improvements in fractionation, on-line separation, dissociation, and mass analysis. The algorithms to match tandem mass spectra to sequences have undergone a parallel evolution, with both spectral alignment and peak matching being paired with diverse methods for scoring proteoform-spectral matches (PrSMs). This study assesses state-of-the-art algorithms for top-down identification through three distinct challenges. The first is identifying a large yield of PrSMs while controlling false discovery rate (FDR) in identifying thousands of proteoforms from complex cell lysates via four software workflows: ProSight Proteome Discoverer, TopPIC, Informed Proteomics, and pTop. The second is the deconvolution of data from both Thermo Orbitrap-class and Bruker maXis Q-TOF instruments to produce consistent precursor charge and mass determinations while generating fragment mass lists to optimize identification. The third attempts to detect diverse post-translational modifications (PTMs) in proteoforms from cow milk and human ovarian tissue. The data demonstrate that existing software suites produce admirable sensitivity, in some cases identifying a third of collected tandem mass spectra with FDR controlled below 2%; the overlap in these PrSMs, however, illustrates real value in searching data with multiple search engines. Differences among identification workflows seem to result from each search algorithm incorporating its own deconvolution algorithm. By transmitting deconvolution data from multiple deconvolution routes (Thermo Xtract, Bruker Auto MSn, Mascot Distiller, TopFD, and FLASHDeconv) to the downstream TopPIC search algorithm, we were able to detect common causes of deconvolution disagreement. The detection of PTMs was very inconsistent among search algorithms, with some workflows suggesting as little as 1% of PrSMs from cow’s milk were singly-phosphorylated while other workflows found that 18% of PrSMs were singly-phosphorylated. Taken together, these results make a strong argument for top-down researchers to adopt a standard practice of analyzing each MS/MS experiment with at least two different search engines.

59 BASIC BIOLOGICAL SCIENCES↗

Effective methylation of phosphonic acids related to chemical warfare agents mediated by trimethyloxonium tetrafluoroborate for their qualitative detection and identification by gas chromatography-mass spectrometry

The effective methylation of phosphonic acids related to chemical warfare agents (CWAs) employing trimethyloxonium tetrafluoroborate (TMO·BF 4 ) for their qualitative detection and identification by gas chromatography-mass spectrometry (GC-MS) is presented. The methylation occurs in rapid fashion (1 h) and can be conveniently carried out at ambient temperature, thus providing a safer alternative to the universally employed diazomethane-based methylation protocols. Optimization of the methylation parameters led us to conclude that methylene chloride was the ideal solvent to carry out the derivatization, and that even though methylated products can be observed surfacing after only 1 h, additional time was not found to be detrimental but beneficial to the process particularly when dealing with analytes at low concentrations (~10 μg mL -1 ). Due to its insolubility in methylene chloride, TMO·BF 4 conveniently settles to the bottom during the reaction and does not produce additional interfering by-products that may further complicate the GC-MS analysis. We demonstrated the method to successfully methylate a variety of Schedule 2 phosphonic acids, including their half esters, resulting in derivatives that were readily detected and identified using the instrument's spectral library. Most importantly, the method was shown to simultaneously methylate a mixture of the organophosphorus-based nerve agent hydrolysis products: pinacolyl methylphosphonate (PMPA), cyclohexyl methylphosphonate (CyMPA) and ethyl methylphosphonate (EMPA) (at a 10 μg mL - 1 concentration each) in a fatty acid ester-rich organic matrix (OPCW-PT-O 3 ) featured in the 38th Organisation for the Prohibition of Chemical Weapons (OPCW) Proficiency Test. Additionally, the protocol was found to effectively methylate N,N-diethylamino ethanesulfonic acid and N,N-diisopropylamino ethanesulfonic acid that are products arising from the oxidative degradation of the V-series agents VR and VX respectively. This work described herein represents the first report on the use of TMO·BF 4 as a viable, stable and safe agent for the methylation of phosphonic acids and their half esters and within the context of an OPCW Proficiency Test sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗