Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spallation Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Proton pulse charge calculation algorithm in Beam Power Limiting System at Spallation Neutron Source

A proton pulse charge calculation algorithm in the Beam Power Limiting System (BPLS) at the Spallation Neutron Source (SNS) was developed and implemented in an FPGA. The algorithm calculates one-minute running average of the pulse charges and issues a fault to the Personal Protection System (PPS) and the Machine Protection System (MPS) when a limit is reached. A bit-accurate model of the algorithm was first developed and tested in Matlab® and then implemented and simulated in VHDL using Vivado® design environment. Finally, the algorithm was verified on a µTCA-based hardware platform.

Bobrek, Miljko [ORNL] (ORCID:0000000332763451)↗

Radioisotope production at the Spallation Neutron Source: Design concept of experimental target station

Completion of the Proton Power Upgrade Project for the Spallation Neutron Source (SNS) accelerator at Oak Ridge National Laboratory opens an opportunity to utilize reserve beam power of more than 100 kW for applications beyond neutron production. One of these applications is the production of critical radionuclides. To demonstrate the feasibility of using the reserve beam power to produce radioisotope at SNS, a design concept of a small-scale experimental target station in the Linac Dump area has been developed. This experimental facility will provide isotope yield benchmarking data using protons in the GeV range. It will also enable additional research and development in isotope handling and radiochemical separation. The target station consists of a target module enclosed in a vessel and concrete shielding. Particle transport calculations and thermo-mechanical simulations are used to determine beam parameters, decay time, isotope yield, shielding dimensions, and target design parameters. Calculations verified that the irradiated capsule can be handled manually using hands-off tools and transported to a hot cell in a shielded container for post-irradiation characterizations.

Lee, Yong Joong [ORNL] (ORCID:0000000298381723)↗

Architecture of the personnel protection systems for Spallation Neutron Source Second Target Station

The Oak Ridge National Laboratory (ORNL) is implementing a major upgrade to the Spallation Neutron Source (SNS) facility, encompassing the addition of the Second Target Station (STS). Preliminary design reviews have been conducted on several STS Personnel Protection Systems (PPS). The reviews focused primarily on the integration with the existing SNS PPS, the new proton transport tunnel, and the target areas. Development of the PPS is ongoing, to ensure a coherent safety system with the mission of protecting users and workers from prompt radiation hazards while providing high beam availability to operations. The STS PPS element in the Integrated Control System (ICS) is a facility-wide system composed of multiple safety subsystems, including the Ring to Second Target (RTST) beam transport tunnel, Target, Bunker and Instruments. Personnel working in all these geographic areas are protected by modular reliable PPS solutions. The safety system enforces access controls, radiation monitoring, beam destination control, and application of critical device inhibit upon detection of abnormal condition. It uses well-documented processes, Common Industrial Protocol (CIP) safety, pulsed test, and redundancy to achieve the desired Safety Integrity Level (SIL). This paper gives an architectural overview of the STS PPS and a detailed safety plan for the SNS facility, addressing safety solutions and human factors.

Michaelides, Tommy [ORNL] (ORCID:0000000190499869)↗

The Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D) at the Spallation Neutron Source (invited)

The Oak Ridge National Laboratory is planning to build the Second Target Station (STS) at the Spallation Neutron Source (SNS). STS will host a suite of novel instruments that complement the First Target Station’s beamline capabilities by offering an increased flux for cold neutrons and a broader wavelength bandwidth. A novel neutron imaging beamline, named the Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D), is among the first eight instruments that will be commissioned at STS as part of the construction project. CUPI 2 D is designed for a broad range of neutron imaging scientific applications, such as energy storage and conversion (batteries and fuel cells), materials science and engineering (additive manufacturing, superalloys, and archaeometry), nuclear materials (novel cladding materials, nuclear fuel, and moderators), cementitious materials, biology/medical/dental applications (regenerative medicine and cancer), and life sciences (plant–soil interactions and nutrient dynamics). The innovation of this instrument lies in the utilization of a high flux of wavelength-separated cold neutrons to perform real time in situ neutron grating interferometry and Bragg edge imaging—with a wavelength resolution of δλ/λ ≈ 0.3%—simultaneously when required, across a broad range of length and time scales. This manuscript briefly describes the science enabled at CUPI 2 D based on its unique capabilities. The preliminary beamline performance, a design concept, and future development requirements are also presented.

47 OTHER INSTRUMENTATION↗

Performance of Oak Ridge National Laboratory spallation neutron source proton power upgrade cavities and cryomodule production

The Proton Power Upgrade initiative at Oak Ridge National Lab’s Spallation Neutron Source aims to greatly boost the capability of proton beam power. This upgrade involves the integration of seven additional cryomodules, each housing four six-cell high-beta ( β = 0.81 ) superconducting radio frequency cavities. These cavities, manufactured and processed by Research Instruments in Germany, underwent meticulous treatment, including electropolishing as the bulk and final vital step. Upon delivery to Jefferson Lab, a total of 28 cavities for seven cryomodules, along with an additional four cavities for a spare cryomodule, underwent thorough vertical qualification tests, meeting the required specifications. Following cavity tanking and subsequent rf testing, the assembly of eight cryomodules was successfully executed, with all 32 cavities demonstrating compliance with acceptance criteria. The transportation of the cryomodule to SNS for high-power testing in the tunnel yielded exceptional results. Notably, the performance surpassed specifications, in terms of quality factor and accelerating gradient. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Conceptual design of a replacement 2.1 K cold box for the Spallation Neutron Source Central Helium Liquefier

Abstract After more than 20 years of operation, the cold compressor technology in use at the Spallation Neutron Source (SNS) is obsolete, and replacement parts and service are no longer available. SNS has partnered with Jefferson Lab to design and construct a replacement sub-atmospheric cold box outfitted with modern cold compressor technology. The general design follows from Jefferson Lab’s experience on other recent sub-atmospheric cold box projects. Design decisions are backed by thorough engineering analysis to ensure technical requirements are met in a cost-effective manner. Conceptual design of the replacement cold box has been completed, and will be summarized in this paper. It features five cold compressors with an operating flow range of 80-140 g/s, and includes piping and valving to support cold compressor maintenance without interrupting flow circulation to the load. The approach to thermal shielding, insulation, and integration of the upgraded cold compressor hardware into the existing SNS control system will also be addressed.

Mastracci, B [Thomas Jefferson National Accelerato↗

Radioisotope production at the Spallation Neutron Source: Design concept of isotope production target

Upon completion of the Second Target Station (STS) Project in the mid 2030s, the Spallation Neutron Source accelerator at Oak Ridge National Laboratory will deliver a 2.7 MW proton beam to the neutron production targets. In the post-STS phase, the accelerator will have a reserve beam power capacity of at least 100 kW beyond what the two neutron production targets will receive, which could potentially be ramped up to 300 kW. In this paper, a design concept for a radioisotope production target that could utilize 250 kW of the reserve beam power capacity is presented. The target consists of thorium discs encapsulated in 316L austenitic steel shells that are cooled by water. The estimated post-irradiation activity of Ac-225 and Ra-225, critical medical radioisotopes used in targeted alpha therapy cancer treatment, is calculated at the end of bombardment after a 14 day long irradiation time. Thermal and structural analyses are performed on the basis of calculated nuclear heating data. The technical feasibility of a high-power target under a 250-kW beam load with an extremely low duty factor of $3.5\cdot 10^{-6}$ is presented from thermal, structural and fatigue lifetime perspectives.

Lee, Yong Joong [ORNL] (ORCID:0000000298381723)↗

Design of a Cryogenic Scintillation Neutrino Detector at the Spallation Neutron Source

We successfully verified in the following three aspects the feasibility of using a cryogenic scintillating crystal-based neutrino detector at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, for the detection of low-mass dark matter particles and non-standard neutrino interactions (NSIs), as part of the detector R&D effort of the COHERENT experiment. First, we demonstrated the possibility of using silicon photomultipliers (SiPMs) at cryogenic temperatures to replace traditional photomultiplier tubes (PMTs) as light sensors. Second, we verified that the high light yield of undoped CsI crystals measured above 13 keVee at 77 K still holds down to 5.9 keVee. Third, we successfully measured nuclear quenching factor of undoped cryogenic CsI at the Triangle Universities Nuclear Laboratory with the help from our Duke collaborators. The first achievement resulted in a publication in European Physics Journal C. The second resulted in an arXiv pre-print, which is under journal review. The last one indicates that the performance of the proposed detector may be better than what was assumed in the literature. The analysis is in the final stage and will result in another journal publication. In addition, two graduate students involved in this project graduated with master’s degrees during the project period. Both decided to continue their research as PhD students. One open-source data analysis code package was created and is publicly available on GitHub. A set of tutorials about Monte Carlo simulation of radiation interacting with detectors were created on YouTube, receiving more than 100,000 views.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics Considerations for a Harp System Design at the Second Target Station of the Spallation Neutron Source

A harp system is being developed for monitoring proton beam profile direct upstream of the proton beam window at the Second Target Station of the Spallation Neutron Source, Oak Ridge National Laboratory. It consists of two sensor planes which have arrays of thin conducting wires aligned vertically and horizontally, respectively. It monitors beam profiles in two transverse directions to the beam axis by measuring the net-charge depositions in the sensor wires, which are caused by ejection of secondary electrons and delta rays driven by electromagnetic interactions with high energy protons. The net charge deposition in a sensing wire linearly correlates with the number of incident protons on it. This correlation is perturbed when the wire interacts with secondary electrons and delta rays originating from beam matter interactions in neighboring wires, PBW and residual gases. In this paper, we analyze the physical phenomena that affects the measurement uncertainties of the harp using particle transport simulations.

Lee, Yong Joong [ORNL] (ORCID:0000000298381723)↗

A compact in situ polarized 3He neutron spin filter for the diffractometer VULCAN at the Spallation Neutron Source

We have built and commissioned a compact in situ 3He polarizer based on spin-exchange optical pumping for the engineering materials diffractometer, named VULCAN, at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The system achieved 78% 3He polarization with a short pump-up time constant of 2.2 h. Its first deployment in an in situ half-polarized neutron diffraction experiment on a magnetic shape memory alloy, Ni–Mn–Ga, revealed changes in magnetization coupled to deformation twinning under compression. With this new capability, VULCAN has become the first diffractometer at SNS capable of performing polarized neutron experiments, opening new opportunities to study a wider range of magnetism-related material behaviors under varied thermal, mechanical, electrical, and/or magnetic fields.

Fu, Sichao [ORNL] (ORCID:0009000846771640)↗

Transient Optimization of the Cryogenic Moderator System Controller at the Spallation Neutron Source for Improved Performance

The high-energy neutron beam generated at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is moderated to use cold (slow) neutrons for scientific discoveries. The Cryogenic Moderator System (CMS) removes heat from the neutron beam using cryogenic hydrogen (H 2 ) moderators connected via heat exchangers to a helium (He) refrigeration loop that dissipates heat using a compressor-brake system. However, the CMS is affected by sporadic losses in beam power, referred to as "beam trips," as these events generate significant disturbances in cooling requirements. To accommodate the heat load transients during beam trips, the CMS uses a decentralized control strategy consisting of four flow valves and one electric heater adjusted by independent proportional-integral (PI) controllers. During the CMS’s initial commissioning, the PI gains were calibrated based only on tracking performance, overlooking their effectiveness in disturbance rejection. A data-driven, control-oriented closed-loop model was developed to recalibrate the PI gains and minimize the transient disturbances caused by beam trips. The model consists of three main components: (1) a physics-based model of the He refrigeration loop, (2) a machine-learning model of the cryogenic H 2 cooling trains, and (3) the control logic used for feedback set-point tracking. Experimental results showed that the recalibrated gains obtained in this study improved the CMS’s transient response during beam trips.

Maldonado Puente, Bryan↗

Calibration of the analog beam-signal hardware for the credited engineered beam power limit system at the Proton Power Upgrade Project at the Spallation Neutron Source

A programmable signal processor-based credited safety control that calculates pulsed beam power based on beam kinetic energy and charge was designed as part of the Proton Power Upgrade (PPU) project at the Spallation Neutron Source (SNS). The system must reliably shut off the beam if the average power exceeds 2.145 MW averaging over 60 seconds. System calibration requires pedigree in measurements, calibration setup, and calculations. This paper discusses the calibration of the analog beam signal components up to and including the Analog Digital Convertors (ADCs) for implementation into the Safety Programmable Logic Controllers (PLCs) and Field Programmable Gate Arrays (FPGAs).

Bobrek, Miljko↗

Dynamic systems modeling of the spallation neutron source cryogenic moderator system to optimize transient control and prepare for power upgrades

Through support of the US Department of Energy's Office of Basic Energy Sciences, Oak Ridge National Laboratory has begun applying machine learning methods to improve accelerator and target performance of the Spallation Neutron Source (SNS). These methods are being applied to the control optimization and power upgrade of the SNS Cryogenic Moderator System (CMS). A numerical model of the CMS has been developed to study these optimizations and system modifications using EcosimPro. This paper compares steady-state and transient numerical results with experimental data. Control optimization studies focused on dampening mass flow, temperature, and pressure fluctuations during sudden losses of accelerator beam power. This analysis was conducted by adjusting five proportional-integral-derivative controllers connected to four flow control valves and one heater. Future efforts include power uprate studies focused on increasing the CMS cooling capacity. The current accelerator power is 1.4 MW; the first target station is being upgraded to 2.0 MW as part of the Proton Power Upgrade effort. The CMS cooling capacity is sufficient for 2.0 MW operation.

47 OTHER INSTRUMENTATION↗

Optimization of neutron chopper and optics for CENTAUR, the SANS/WANS diffractometer at the spallation neutron source second target station

Herein this report presents the physics design and optimization of the neutron chopper and optics systems for the CENTAUR instrument, a multifunctional small-angle and wide-angle neutron scattering diffractometer for the Spallation Neutron Source Second Target Station. This instrument will offer a wide range of capabilities, including small-angle neutron scattering with wide Q coverage (e.g., 0.001–20 Å –1 ), providing a tool to investigate structures from atomic to mesoscopic scales simultaneously. To efficiently transport desired neutrons from the compact high-brightness cold source, several innovative designs are utilized: a time-zero chopper with a straight guide system for short-wavelength neutrons, octagonal guides for higher flux, and a correlation chopper to reduce inelastic scattering. The optimization process considers factors such as useable time-integrated flux, instrument resolution, brilliance transfer, divergence, and acceptance diagram uniformity. The overall design prioritizes flexibility to accommodate diverse user requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Measured and Calculated Dose Rates for Ring Injection Dump Exchange at Spallation Neutron Source

According to the accelerator operation plan, the beam-stop and the proton beam window (PBW) assemblies of the existing Ring Injection Dump RID are replaced with fresh assemblies, when they have reached their end-of-life. End of-life is determinate by the stainless-steel beam-stop window having accumulated 10 dpa radiation damage. The exchange process took place during facility maintenance period that started in March 2023. Each of the spent assembles were put into specially designed storage containers temporarily residing near the RID building.The spent beam-stop is predicted to be the part of highest activation that has been removed in Spallation Neutron Source (SNS). The exchange processes require good work planning to minimize radiation exposure to personal. For each exchange step the residual dose rate distribution is calculated and the peak values are identified. This paper gives some examples of calculated vs measured doses during beam-stop assembly exchange.

Popova, Irina I.↗

Spallation Neutron Source Second Target Station Construction Project: Biological Assessment

The Endangered Species Act of 1973 (16 U.S.C. 153 et seq.), as amended (ESA or Act) in section 7(a)(1) directs Federal agencies to conserve and recover listed species and use their authorities in the furtherance of the purposes of the Act by carrying out programs for the conservation of endangered and threatened species so that listing is no longer necessary (50 CFR §402). Furthermore, the Act in section 7(a)(2) directs Federal agencies to consult (referred to as section 7 consultation) with the U.S. Fish and Wildlife Service (USFWS) when their activities “may affect” a listed species or designated critical habitat. This biological assessment (BA) analyzes the potential effects of the proposed Spallation Neutron Source Second Target Station STS construction project on the U. S. Department of Energy Oak Ridge Reservation (ORR) on Federal listed threatened, endangered, proposed, and under consideration for Federal listing bat species, pursuant to section 7(a)(2) of the ESA.

54 ENVIRONMENTAL SCIENCES↗

Improved limits on n → n ' transformation from the Spallation Neutron Source

Conversions between neutrons n and dark matter candidate sterile neutrons n' have been proposed as a mechanism for baryon number $\mathscr{B}$ violation. In the case that there is a small mass difference Δ⁢m between the n and the n' states, oscillations can be induced by compensating for Δ⁢m with a magnetic field. A search for such neutron oscillations was performed at the Spallation Neutron Source by looking for anomalous neutron transmission through a strongly absorbing cadmium wafer inside of a 6.6 T magnet. The approach described here saw no regenerated neutrons above background, which provides an improved limit for neutron–sterile neutron transformations for a range of Δ⁢m between 0.1 and 1000 neV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗