Test Plan for DOE-GENIORS Dyanamic Irradiation Tests

Dynamic irradiation tests will be performed within the DOE-GENIORS collaboration, to be finished by the end of March 2021. These tests will be performed using three different setups, one at INL, one at CEA, and one at CIEMAT. The cis-mTDDGA/PTD chemical system will be used, applying both "extraction" (cis-mTDDGA - n-dodecane/HNO3) and "stripping" (cis-mTDDGA - n-dodecane/PTD - HNO3) conditions. This test plan provides the details and parameters to be used to perform irradiation at the INL using the INL Radiolysis Test Loop.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pilot Testing of Amine-Based Solvent at Low-Rank Coal Fired Power System

Conference presentation for the 2023 International Freiberg Conference on Circular Carbon Technologies, Rotterdam, Netherlands, September 24–29, 2023. This presentation describes pilot testing of an amine-based CO₂ capture system at Coal Creek Station, examining solvent performance, system design, and operating conditions for a low-rank coal-fired power plant. The Mitsubishi Heavy Industries KM CDR (KS-1) process is assessed using pilot-scale data to inform capture efficiency, solvent condition, and integration considerations.

01 COAL, LIGNITE, AND PEAT↗

Radiological Degradation of Tetraoctyl Diglycolamide in n-Alkyl Solvents: Influence of Solvent Ionization Potential

Reprocessing of used nuclear fuel reduces the requirements for long-term storage repositories. Cost-efficient processes depend on knowledge of radiation effects, but gaps occur in understanding how radiation results in the degradation of fuel separation molecules. This project investigates the influence of different n-alkyl solvents on the radiolytic fragmentation behavior of N,N,N',N'-Tetraoctyl-3-oxapentane-1,5-diamide (TODGA), a promising ligand for extraction of the lanthanides and minor actinides from dissolved nuclear fuel. Findings from this work suggest a linkage between the ionization potential of the solvent and the degradation products observed in the resulting mass spectrum.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Strong degradation of polycarbonate and polystyrene by the CO 2 capture solvent diethyl sebacate

Here, we report on observations of strong degradation of a polycarbonate vessel by a solvent being considered for a CO 2 capture process, diethyl sebacate. This degradation led to failure of a polymeric hollow fiber membrane unit. Additional tests showed rapid degradation of polycarbonate safety glasses and polystyrene-based petri dishes by exposure to diethyl sebacate at ambient conditions. We also report on safe operations with diethyl sebacate in extensive experiments studying the corrosion of steel in CO 2 -pressurized reactors lined with PTFE and using PTFE gaskets. Used diethyl sebacate was also stored for long time periods in bottles made from low-density polyethylene bottles without physical deterioration. These observations indicate that care must be taken in development of new contactors and processes for CO 2 capture with diethyl sebacate and related solvents and in the choice of material for storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kinetics for the reaction between the solvated electron and dissolved oxygen in n-dodecane from 2.5 to 40 °C

Temperature-controlled, time-resolved picosecond electron pulse radiolysis was utilized to measure the rate of reaction between the solvated electron (eS–) and dissolved oxygen in n-dodecane solutions from 2.5 to 40 °C for the first time. At 20.0 °C, the reaction rate was determined to be k(eS– + O2) = (4.54 ± 0.21) × 1010 M-1 s-1, with an activation energy of Ea = 14.4 ± 1.3 kJ mol-1. These newly determined kinetic parameters are important for predicting and managing the effects of aerated environments on the degradation of organic solvents used in nuclear fuel reprocessing technologies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Modeling the Fundamental Radiation Chemistry of the Organic Diluent, and the Effect of Metal Ion Complexation on the Radiochemical Behavior of Active Compounds

All used nuclear fuel (UNF) reprocessing technologies must operate efficiently in the presence of an intense, multi-component (predominantly alpha, beta, and gamma) radiation field. Consequently, radiation-induced degradation of reprocessing systems is of concern, as it negatively impacts process performance over time due to the destruction of both active compounds (ligands, phase modifiers, holdback agents, etc.) and the formation of degradation products. Reprocessing solvent system radiolysis has been linked to changes in separation efficiency and physical properties of solvent mixtures, solvent-recycle longevity, crud formation, and other unexpected outcomes that impact the efficient recovery of valuable materials (e.g., the actinides) and the volume of hazardous radioactive waste for final disposal, i.e., in a geological repository. Consequently, a fundamental understanding of radiolytic processes and their effects on reprocessing solvent system performance is critical for: (i) the cost-effective development and innovation of separation technologies; (ii) the design and implementation of predictive radiation chemical models for process monitoring and lifetimes; and (iii) potentially the ability to exploit radiolytic phenomenon to our benefit, e.g., strategic radiolysis of active molecules to liberate specific degradation products that aid subsequent process stages. Despite extensive investigation into the radiolytic behavior of active solvent system compounds, little attention has been given to understanding (i) the radiation chemical behavior and modification of the organic diluent and (ii) the effect of metal ion complexation on the radiochemical behavior of active compounds.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fluor Solvent Evaluation and Testing New Scope: Techno-economic Assessment of EEMPA Solvent for CO 2 Separations from Natural Gas Combined Cycle Power Plant

In this project, a techno-economic analysis (TEA) and sensitivity studies were conducted to assess the PNNL’s leading water-lean CO 2 capture solvent, EEMPA, for capture CO 2 from a natural gas combined cycle (NGCC) power plant at different levels of capture rate. Process models for the NGCC power plant, integrated with EEMPA carbon capture processes, were developed in Aspen Plus V14 using the most up-to-date property package for EEMPA-H 2 O-CO 2 system. The TEA evaluated EEMPA carbon capture process at normal capture rates (90%, 95% and 97%) against Case B32B (Cansolv) described in NETL Rev4a baseline report, and at higher capture rates aimed at achieving zero or negative emissions from the power plant (400 ppmv, 200 ppmv, and 100 ppmv CO 2 in exhaust gas), compared to typical Direct Air Capture (DAC) technologies. A manuscript was drafted for peer-reviewed publication. The results suggested that the carbon capture cost reaches a minimum of $\$$53.7/tonne CO 2 at 90% capture rate. Compared to Cansolv, one of the industrial benchmarks, EEMPA demonstrates 2-4% cost savings at capture rates up to 95%, but minimal savings at higher capture rate. The water lean-solvent system proves economically attractive for achieving moderate negative emissions (about 200 ppmv CO 2 in exhaust gas, and equivalent to 50% CO 2 removal from air) for NGCC flue gas, with marginal capture costs comparable to direct air capture (DAC) technologies. A sensitivity analysis results reveal that its economic advantage, unaffected by EEMPA price due to low solvent loss and degradation rate. However, the marginal carbon capture cost exceeds $\$$1,000/tonne CO 2 when transitioning from moderate to extreme negative emissions (100 ppmv CO 2 in exhaust gas), suggesting that water-lean solvents may not be economically competitive with other DAC technologies for removing more than 75% CO 2 from air. In addition, initial connection was established with Technology Center Mongstad (TCM) for a potential pilot testing proposal. However, detailed modeling and proposal preparation was not conducted due to the delay of non-disclosure agreement.

20 FOSSIL-FUELED POWER PLANTS↗

Universal Solvent Viscosity Reduction via Hydrogen Bonding Disruptors

Liquid Ion Solutions LLC (DBA RoCo Global) in partnership with Carnegie Mellon University and Carbon Capture Scientific LLC, has performed lab-scale development and evaluation of novel additives that lower the viscosity of water-lean amine solvents for post-combustion carbon dioxide capture. This project focuses on developing additives that minimize the formation of long-range electrostatic and hydrogen bonding (HB) networks, decreasing the solvent viscosity, improving diffusion, and improving the process economics. The project objectives included: 1) performing computer simulation to understand the molecular interactions of the additive molecules in water-lean CO 2 capture solvents, 2) design and synthesis of HB disruptors additives, 3) performance testing with additive molecules on model amine solvents, and 4) demonstration of the effectiveness of the optimized additives in the presence of synthetic flue gas. To meet the abovementioned objectives, the project team utilized a holistic approach that combines molecular simulation, experimental testing, and economic analysis studies. The project team developed ab initio molecular model and then perform computer simulation to develop relationship between hydrogen bonding, viscosity, and performed quantitative analysis of additive on the viscosity of the solvent. The team completed computational comparative study on a range of organic functional groups such as ethers, esters, cyclic carbonates, alkanes, and ammonium salts for their effect on viscosity gaining key insights into molecular interactions and the impact of various functional groups and molecular shapes on viscosity. Assisted with molecular simulation insights, the project team conducted additive synthesis and testing, including a proof-of-concept study, additive screening, optimization, and synthetic flue gas testing. The experimental proof-of-concept study proved that the hydrogen bonding acceptors result in significant decrease of viscosities. Detailed additive screening (exploring various functionalities and molecular structures) has been performed. Several promising additives showed excellent reduction in viscosity (30-41%) at 5% additive loading, and over 50% viscosity reduction at 10% additive loading for the model solvents. The team also performed complex screening studies on additive loadings and mixing effect among additives using the design of experiments. Based on multiple screening experiments, one additive-solvent candidate was down-selected for synthetic flue gas testing. A 100-hour continuous absorption/desorption study was conducted under simulated flue gas using a lab-scale continuous capture and separation system. No degradation (for both solvent and additive) was observed based on the GC results of the solvent samples collected from the continuous study. The team conducted preliminary engineering analyses and cost-benefit analyses to quantify the potential economic benefits of the additive approach for solvent viscosity reduction. Based on the experimental data, CO 2 capture cost savings from the capital and operating cost savings are estimated at $\$$4.7/tonne and $\$$0.3/tonne CO 2 captured, respectively. Considering the additive cost, the net benefit is estimated to be between $\$$4.32~$\$$4.86/tonne CO 2 captured.

20 FOSSIL-FUELED POWER PLANTS↗

A simulation-based model studying monoethanolamine and aprotic heterocyclic anion ionic liquid (AHA-IL) mixtures for carbon capture

Capturing of waste CO 2 , particularly from large industrial point sources, is necessary for either permanent storage or CO 2 utilization. Amine solvents used for carbon capture have certain drawbacks, particularly the high energy required by the reboiler for solvent regeneration and degradation of the amine with absorption/regeneration cycling. These challenges may be overcome using ionic liquids (ILs) that can be tailored for operating under typical flue gas stream conditions (8–10% CO 2 , 18–20% H 2 O, 2–3% O 2 , and 67–72% N 2 ). ILs, however, oftentimes suffer from high viscosities, leading to diffusion limitations when compared to amine solvents. This work models the combinations of aprotic heterocyclic anion ILs (AHA-IL) with monoethanolamine (MEA) and studies the carbon capture effectiveness of these mixtures. Furthermore, this study found that all AHA-IL/MEA mixtures exhibited 32 % lower enthalpy of reaction (compared to MEA) and 64 % lower viscosity (compared to AHA-IL), which are desirable characteristics for CO 2 capture solvents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mitigation Methods for Piperazine Oxidation in Post-Combustion Carbon Capture

Piperazine is a promising second-generation solvent for amine scrubbing in post-combustion CO2 capture. However, the oxidative degradation of PZ can cause environmental problems and economic loss. This work presents the effects of two mitigation methods: carbon treating and N2 sparging, on the PZ oxidation in long-term operations. The species and their respective quantities adsorbed by the activated carbon were tested in a bench-scale device. The carbon was then tested in the High Temperature Oxidation Reactor (HTOR), where the solvent oxidizes at a reasonably fast rate. Pilot plant campaigns were also performed at the UT Austin SRP and the National Carbon Capture Center (NCCC) and the effects were verified. When dissolved Fe is removed by carbon treating or other methods, available soluble Fe in the system dissolves and replaces the dissolved Fe. Therefore, all available Fe and ligands need to be removed for the mitigation to be effective. The sources of soluble Fe include fly ash and the corrosion of stainless steel, and the ligands are degradation products. 8 All PZ degraded solvents have two absorbance peaks at 320 nm and 538 nm. The 320 nm peak is caused by dissolved metals, especially Fe, complexed by degradation products. The 320 nm peak is related to the amine degradation level and can be used as a simple and efficient method to estimate the amine degradation rate. The pilot plant data suggest that NO2 can oxidize PZ significantly, possibly through radical reactions. 0.01 mmol/kg-hr absorption of NO2 increased the PZ oxidation rate from 1.2 mmol/kg-hr to 2.5 mmol/kg-hr.

Yuying, Wu↗

Probing the Reactivity of the Active Material of a Li-Ion Silicon Anode with Common Battery Solvents

Calculations and modeling have shown that replacing the traditional graphite anode with silicon can greatly improve the energy density of lithium-ion batteries. However, the large volume change of silicon particles and high reactivity of lithiated silicon when in contact with the electrolyte lead to rapid capacity fading during charging/discharging processes. In this report, we use specific lithium silicides (LS) as model compounds to systematically study the reaction between lithiated Si and different electrolyte solvents, which provides a powerful platform to deconvolute and evaluate the degradation of various organic solvents in contact with the active lithiated Si-electrode surface after lithiation. Nuclear Magnetic Resonance (NMR) characterization results show that a cyclic carbonate such as ethylene carbonate is chemically less stable than a linear carbonate such as ethylmethyl carbonate, fluoroethylene carbonate, and triglyme as they are found to be more stable when mixed with LS model compounds. Furthermore, guided by the experimental results, two ethylene carbonate (EC)-free electrolytes are studied, and the electrochemical results show improvements with graphite-free Si electrodes relative to the traditional ethylene-carbonate-based electrolytes. More importantly, the study contributes to our understanding of the significant fundamental chemical and electrochemical stability differences between silicon and traditional graphite lithium-ion battery (LIB) anodes and suggests a focused development of electrolytes with specific chemical stability vs lithiated silicon which can passivate the surface more effectively.

25 ENERGY STORAGE↗

Targeted electrochemical reduction of carcinogenic N -nitrosamines from emission control systems within CO 2 capture plants

N-Nitrosamines are one of the environmentally significant byproducts from aqueous amine-based post-combustion carbon capture systems (CCS) due to their potential risk to human health. Safely mitigating nitrosamines before they are emitted from these CO 2 capture systems is therefore a key concern before widescale deployment of CCS can be used to address worldwide decarbonization goals. Electrochemical decomposition is one viable route to neutralize these harmful compounds. The circulating emission control waterwash system, commonly installed at the end of the flue gas treatment trains to minimize amine solvent emissions, plays an important role to capture N-nitrosamines and control their emission into the environment. The waterwash solution is the last point where these compounds can be properly neutralized before becoming an environmental hazard. In this study, the decomposition mechanisms of N-nitrosamines in a simulated CCS waterwash with residual alkanolamines was investigated using several laboratory-scale electrolyzers utilizing carbon xerogel (CX) electrodes. Hcell experiments revealed that N-nitrosamines were decomposed through a reduction reaction and are converted into their corresponding secondary amines thereby neutralizing their environmental impact. Batch-cell experiments statistically examined the kinetic models of N-nitrosamine removal by a combined adsorption and decomposition processes. The cathodic reduction of the N-nitrosamines statistically obeyed the first-order reaction model. Finally, a prototype flow-through reactor using an authentic waterwash was used to successfully target and decompose N-nitrosamines to below the detectable level without degrading the amine solvent compounds allowing them to be return to the CCS and lower the system operating costs. Furthermore, the developed electrolyzer was able to efficiently remove greater than 98% of N-nitrosamines from the waterwash solution without producing any additional environmentally harmful compounds and offers an effective and safe route to mitigate these compounds from CO 2 capture systems.

20 FOSSIL-FUELED POWER PLANTS↗

Research on oxygen solubility in aqueous amine solvents with common additives used for CO 2 chemical absorption

Oxidative degradation in amine based post-combustion carbon capture (PCCC) leads to solvent losses and decreased solvent performance. Oxygen (O 2 ) in the flue gas is dissolved into the aqueous solvent and can reactively degrade the amine component. Advanced aqueous amine solvents are designed to contain additional surfactant and anti-foam additives as well as two types of corrosion inhibitors. These additives contribute to improve the solvent performance while reducing foaming and corrosion of expensive equipment. This work examines the impact of these additives on oxygen solubility (or dissolved oxygen - DO) in various aqueous amines used in PCCC including ethanolamine (MEA), 1-amino-2-propanol (A2P), 2-amino-1-propanol (2A1P), 2-(methylamino)-ethanol (NMEA), 2-(ethylamine)-ethanol (2EAE), diethanolamine (DEA), methyl-diethanolamine (MDEA), dimethylethanolamine (DMEA), piperazine (PZ), 1,2-ethyldiamine (EDA), and 1,6 hexadiamine (HDA). Further, the impact of carbon loading on oxygen solubility with and without these additives was also examined. The surfactant and anti-foam additives had minimal impact on DO for all the solvents investigated. The two anticorrosion additives had opposite effects in the measured DO, 2- mercaptobenzothiazole (MBT) decreased the DO concentration, and sodium metavanadate showed an increase. These results indicate that several of these common additives can be expected to minimally affect DO related oxidative degradation in these advance amine solvents.

60 APPLIED LIFE SCIENCES↗

Multi-strain analysis of Pseudomonas putida reveals the metabolic and genetic diversity of the species

Pseudomonas putida is a gram-negative bacterial species increasingly utilized in biotechnology due to its robust growth, ability to degrade aromatic compounds, solvent tolerance, and genetic tractability. In this study, we report a comprehensive multi-strain analysis of 164 P. putida strains based on the reconstruction of a pan-putida metabolic network and the formulation of strain-specific genome-scale metabolic models (GEMs). We performed whole-genome sequencing and hybrid assembly for 40 strains, contributing a ~8% increase to the available genomic data for P. putida . Furthermore, high-throughput phenotypic profiling using the Biolog phenotype microarray system for 24 strains on 190 unique carbon sources, along with 15 aromatic compounds not present on Biolog plates, yielded 4,920 unique strain-phenotype measurements. These data were leveraged to curate GEMs for 24 representative strains, including a refined model for strain KT2440, which comprised 1,480 genes and 2,191 metabolites, achieving a prediction accuracy of 91.2% in carbon utilization. Systematic comparison of genomes and GEMs revealed both conserved core pathways and significant allelic and functional divergence across strains, highlighting strain-specific variation in aromatic degradation. While pathways for protocatechuate and phenylacetate degradation were widely conserved, metabolic capabilities for compounds such as ferulate, phenol, and cresols varied markedly, suggesting adaptation to distinct ecological niches. Alleleome analysis of enzymes, such as PcaI and PcaJ, revealed distinct, functionally similar clades, indicating possible convergent evolution or horizontal gene transfer. These results provide computable resources and informative models for selecting P. putida strains with desired traits for biomanufacturing and bioremediation and offer insights into the evolution and phylogeny of the P. putida species.

aromatics utilization↗

Thermodynamic Water Activity Explains the Unusual Electrochemical Stability of Aqueous Deep Eutectic Solvents

The presence of water in nonaqueous deep eutectic solvent (DES) electrolytes has been debated in recent years, with efforts ranging from its complete removal to willful addition. It was shown that controlled amounts of water can be beneficial, as it not only enhances the physicochemical properties of these electrolytes but also has no significant detrimental effects on their electrochemical stability. Despite these advantages, there is still limited understanding of how water interacts with DES systems at the molecular level. This study examines the water activity in ethylene glycol and glycerol, as well as their binary mixtures with choline chloride to form the DESs ethaline and glyceline, respectively. In this work, we show that the high electrochemical stability of glyceline is related to its lower water activity compared to ethaline and can be attributed to the robust H-bonding network formed by the three hydroxyl groups of glycerol. Its 3D H-bond network effectively integrates water molecules within its solvent structure, reducing degradation and maintaining stability at higher water contents. The deviations from the ideal Raoult's law behavior are reflected in the water activity and activity coefficients, which highlight the intricate H-bond interactions within DES-water mixtures. Water acts like a lubricant within the more viscous DES mixtures without being detrimental to their electrochemical performance. The presented results emphasize the necessity of customizing DES-water compositions to enhance their performance as electrolytes, especially in flow battery applications where electrochemical stability, ionic conductivity, and fluidity are of utmost importance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon Capture Pilot at Vicksburg Containerboard Mill (Final Technical Report)

This is the final technical report for the DOE-OCED project DE-CD0000051. The report provides the progress at the close of the project. The objective of the project is to design and build a large pilot plant for carbon dioxide (CO 2 ) capture from a pulp and paper (P&P) mill using RTI’s non-aqueous solvent (NAS) technology at a capacity of 120,000 t-CO 2 /year, with >90% CO 2 captured. The pilot plant will be used for testing and evaluating the NAS capture process using real flue gas from the P&P mill’s power boiler for a minimum of 1 year of parametric testing and a minimum of 2,000 hours of continuous long-term testing. The testing will provide data for process optimization and scale-up for the P&P industry, provide information on interaction of flue gas contaminants on solvent performance and degradation, and inform strategies for emission control. At the end of the project, the pilot plant will be managed by International Paper (IP), the host site owner, which will continue to capture CO 2 , sequester the captured CO 2 , and be eligible for the 45Q credit.

42 ENGINEERING↗