DOE OSTI2025
A magnesium oxysulfate (MOS) grout formulation has been identified to solidify the liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery System (ARS). The formulation uses reactive, light burnt MgO (28 wt%), anhydrous MgSO 4 (10 wt%), and dead burnt MgO (62 wt%), resulting in a grout with good mixability, acceptable density, acceptable setting times, and a leachate pH around 9.4, within the assumed Waste Isolation Pilot Plant (WIPP) brine pH range. A series of tests were then designed to observe how this formula reacted to variations in the liquid effluent. Liquid effluent temperature, the caustic pH level, concentration of NaNO 3 , and the presence of neutralization products, trace metals, and/or sodium sulfate (all potential residuals found in the effluent from upstream processing), were evaluated to see how each impacts the grout mixing time, peak temperature, setting time, presence of bleed water, leachate pH, and density. The standard mix has an average mixing time of 18 minutes, peak temperature of 100.5 °C, and set time of 60 minutes. Increasing the temperature of the liquid effluent increased the reaction rate of the mix and reduced mixing and setting times. Between 30 and 40°C the change was relatively small, raising no more than 6 °C compared to the standard mix maximum temperature. Increasing the pH of the liquid effluent had no significant impact on the mix. The addition of neutralization products and trace metals had an overall impact of decreasing the reactivity of the mix. The addition of more ions in the liquid effluent, such as an increase in the concentration of NaNO 3 and the addition of Na 2 SO 4 , generally decreased the reactivity of the mix. None of the variations to the liquid effluent hindered solidification as indicated by the lack of bleed water found on all the samples. The leachate pH values for all mixes tested did not significantly vary from the expected pH of 9.4 and none of the density values fell below 1.8 g/cm 3 . Overall, changes to the liquid effluent were found to have a minimal impact on the formulation suggesting the grout's ability to properly form despite increased temperatures and the presence of residuals typically found in the liquid effluent from the ARS.
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗