Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Internal Indpendent Assessment Report - CASTLE-PX SQA

This IIA assessed the flow down of institutional 830 Software Quality Assurance requirements through three required document templates to the CASTLE-PX software effort and the implementation of those SQA requirements. The templates flow down the DOE O 414.1D consensus standard requirements for Safety Software. This assessment did not include the flow down of NAP-24, Weapon Quality Policy, requirements. The assessment focused on the CASTLE-PX project’s software development and release processes. It did not assess Pantex’s acceptance or usage of the software. The assessment resulted in 3 Deficiencies, 5 Observations, 1 Recommendation, and 3 Strengths. Overall the CASTLE-PX team demonstrated it values quality and has worked to integrate quality practices into its software development processes. Improvement in documentation will enhance their SQA implementation.

97 MATHEMATICS AND COMPUTING↗

BENCHMARKING UPGRADED HOTSPOT DOSE CALCULATIONS AGAINST MACCS2 RESULTS

The radiological consequence of interest for a documented safety analysis (DSA) is the centerline Total Effective Dose Equivalent (TEDE) incurred by the Maximally Exposed Offsite Individual (MOI) evaluated at the 95th percentile consequence level. An upgraded version of HotSpot (Version 2.07) has been developed with the capabilities to read site meteorological data and perform the necessary statistical calculations to determine the 95th percentile consequence result. These capabilities should allow HotSpot to join MACCS2 (Version 1.13.1) and GENII (Version 1.485) as radiological consequence toolbox codes in the Department of Energy (DOE) Safety Software Central Registry. Using the same meteorological data file, scenarios involving a one curie release of {sup 239}Pu were modeled in both HotSpot and MACCS2. Several sets of release conditions were modeled, and the results compared. In each case, input parameter specifications for each code were chosen to match one another as much as the codes would allow. The results from the two codes are in excellent agreement. Slight differences observed in results are explained by algorithm differences.

54 ENVIRONMENTAL SCIENCES↗

Items Supporting the Hanford Internal Dosimetry Program Implementation of the IMBA Computer Code

The Hanford Internal Dosimetry Program has adopted the computer code IMBA (Integrated Modules for Bioassay Analysis) as its primary code for bioassay data evaluation and dose assessment using methodologies of ICRP Publications 60, 66, 67, 68, and 78. The adoption of this code was part of the implementation plan for the June 8, 2007 amendments to 10 CFR 835. This information release includes action items unique to IMBA that were required by PNNL quality assurance standards for implementation of safety software. Copie of the IMBA software verification test plan and the outline of the briefing given to new users are also included.

61 RADIATION PROTECTION AND DOSIMETRY↗

Connecting Electric Vehicle Charging Infrastructure to Commercial Buildings

Electric vehicles (EVs) are growing in popularity and gaining meaningful market share with record sales year over year in the last decade. EV charging equipment, also known as EV chargers (EVC) or EV supply equipment (EVSE), must proportionally match the growing number of new EVs on the road for a comparable experience to gas-powered vehicles. The majority of EV charging currently happens at residential buildings. However, demand for EV charging at commercial buildings will significantly increase with wider mainstream EV adoption and as businesses return to more normal operation following COVID-19 pandemic disruptions. Charging equipment can include various sub-systems like power conditioning module, control software, safety devices, metering, communication, cooling, connectors, and its wiring. EV charging at commercial buildings could be used for public, workplace, and commercial fleet charging. This document aims to describe how EVC can be connected to commercial buildings, including considerations for facility managers, and the effects that charging will have on the buildings electrical distribution system. More specifically, this resource provides an overview of: understanding EV charging basics: how charging equipment connects to the building and to EVs; required infrastructure updates needed at the building site to connect EVC to existing distribution systems; network strategies for cost-effective operation; metering and utility considerations for billing and incentives; charging equipment ownership options; future trends in EVC connection to buildings.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Safety Assurance of Software and Machine Learning Development for Nuclear Instrumentation and Controls

Digital instrumentation and control (DI&C) systems monitor and control parameters in nuclear power plants. Ensuring their safety is a critical part of ensuring overall plant safety. Nuclear power plant licensing generates thousands of safety documents that could be organized more effectively using a safety assurance case (SAC). We conducted a literature survey of SACs and created a SAC framework for DI&C software using Goal Structuring Notation (GSN). This framework focuses on four software development processes: management & assurance, pre-developed software (PDS) qualification, the Software Development Life Cycle (SDLC), and the Machine Learning Development Life Cycle (MLDLC). We organized our framework using a novel level structure that can be applied to other SACs to improve their clarity. Finally, we demonstrate how our framework can be incorporated as part of a SAC for a larger reactor system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

HAZARD ANALYSIS SOFTWARE

Washington Safety Management Solutions, LLC developed web-based software to improve the efficiency and consistency of hazard identification and analysis, control selection and classification, and to standardize analysis reporting at Savannah River Site. In the new nuclear age, information technology provides methods to improve the efficiency of the documented safety analysis development process which includes hazard analysis activities. This software provides a web interface that interacts with a relational database to support analysis, record data, and to ensure reporting consistency. A team of subject matter experts participated in a series of meetings to review the associated processes and procedures for requirements and standard practices. Through these meetings, a set of software requirements were developed and compiled into a requirements traceability matrix from which software could be developed. The software was tested to ensure compliance with the requirements. Training was provided to the hazard analysis leads. Hazard analysis teams using the software have verified its operability. The software has been classified as NQA-1, Level D, as it supports the analysis team but does not perform the analysis. The software can be transported to other sites with alternate risk schemes. The software is being used to support the development of 14 hazard analyses. User responses have been positive with a number of suggestions for improvement which are being incorporated as time permits. The software has enforced a uniform implementation of the site procedures. The software has significantly improved the efficiency and standardization of the hazard analysis process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THE RADIATION SAFETY INFORMATION COMPUTATIONAL CENTER: A RESOURCE FOR REACTOR DOSIMETRY SOFTWARE AND NUCLEAR DATA

The Radiation Safety Information Computational Center (RSICC) was established in 1963 to collect and disseminate computational nuclear technology in the form of radiation transport, shielding and safety software and corresponding nuclear cross sections. Approximately 1700 nuclear software and data packages are in the RSICC collection, and the majority are applicable to reactor dosimetry.

reactor dosimetry software nuclear data↗

TU-FG-201-07: Development of SRS Conical Collimator Collision Prediction Software for Radiation Treatment Safety

Purpose: Stereotactic radiosurgery (SRS) treatments using conical collimators can potentially result in gantry collision with treatment table due to limited collision-clear spaces. An in-house software was developed to help the SRS treatment planner mitigate potential SRS conical collimator (Varian Medical System, Palo Alto, CA) collisions with the treatment table. This software was designed to remove treatment re-planning secondary to unexpected collisions. Methods: A BrainLAB SRS ICT Frameless Extension used for SRS treatments in our clinic was mathematically modelled using surface points registered to the 3D co-ordinate space of the couch extension. The surface points are transformed based on the treatment isocenter point and potential collisions are determined in 3D space for couch and gantry angle combinations. The distance between the SRS conical collimators and LINAC isocenter is known. The collision detection model was programmed in MATLAB (Mathwork, Natick, MA) to display graphical plots of the calculations, and the plotted data is used to avoid the gantry and couch angle combinations that would likely result in a collision. We have utilized the cone collision tool for 23 SRS cone treatment plans (8 retrospective and 15 prospective for 10 patients). Results: Twenty one plans strongly agreed with the software tool prediction for collision. However, in two plans, a collision was observed with a 0.5 cm margin when the software predicted no collision. Therefore, additional margins were added to the clearance criteria in the program to achieve a lower risk of actual collisions. Conclusion: Our in-house developed collision check software successfully avoided SRS cone re-planning by 91.3% due to a reduction in cone collisions with the treatment table. Future developments to our software will include a CT image data set based collision prediction model as well as a beam angle optimization tool to avoid normal critical tissues as well as previously treated lesions.

60 APPLIED LIFE SCIENCES↗

Capability Enhancements for System-level thermal Hydraulic Modeling of Lead Fast Reactors

This project has focused on the use, assessment, and development of the SAS4A/SASSYS-1 (SAS) safety analysis software. Although SAS was originally intended as a safety analysis tool for Liquid Metal cooled Fast Reactors (LMFRs), which includes both Sodium Fast Reactors (SFRs) and Lead Fast Reactors (LFRs), the vast majority of its recent development and customization has been tailored to SFRs. In general, enhancements that are made to the software for SFRs are applicable to LFRs, however, the fuel composition and corrosive nature of lead requires careful consideration when performing safety analysis of an LFR. In this project an emphasis was placed on closing gaps that are associated with modeling LFRs using SAS. The principal objective of the project was to enhance the ability of SAS as a licensing tool for LFRs. This objective was to be accomplished through three tasks: 1) Enhance the ability of SAS to couple with external software; 2) Improve the underlying physics models in SAS, with priority given to models that are highly relevant to LFRs; 3) Extend the Verification and Validation (V&V) basis of the software

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Safety Requirement Management System (SRMS) - Improved Documented Safety Analyses Implementation - 18476

Savannah River Remediation (SRR) developed a new software application, Safety Requirement Management System (SRMS), to improve Documented Safety Analysis (DSA) safety requirement implementation in the Savannah River Site's Liquid Waste facilities. Technical Safety Requirement (TSR) Limited Conditions of Operations (LCOs) and related surveillances were previously tracked using four different applications. Due to their differences and their age, the applications introduced a number of operational challenges and vulnerabilities, including outdated platforms, usage demands beyond original design, and different organizational work processes. SRMS was developed to resolve these issues by using a single web-based approach that provides consistency, wider accessibility, simpler maintenance, and a platform for additional functionality. Other SRS facilities are evaluating the application for its applicability as a standard practice across the site. The new SRMS application decreased the administrative overhead for application maintenance, provided the needed TSR change management functionality, and reduced error precursors with the following advantages: - Consistent process/application across all SRR facilities - More efficient way to track and communicate compliance with DSA time-related requirements (i.e., TSR LCOs and surveillances). - Web-based search capability for LCO entries/exits and a record of surveillance performances. - TSR change management and independent reviews through electronic approvals. For example, the application provides the ability to bundle and stage LCO and surveillance changes associated with a TSR revision. The approval process involves multiple roles from the facility to ensure validity. - Formal configuration management program, fully supported by software life cycle documents. SRMS was implemented at Defense Waste Processing Facility (DWPF) in June 2017, with implementation in all Liquid Waste facilities expected by the end of 2017. Next, SRR plans to expand SRMS functionality to include a linking document database (LDD) to support the DSA requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Software and Hardware Systems in the Safety Control Systems of Nuclear Power Plants

Fundamentally new software and hardware systems for lower level automation in the safety monitoring and control systems of nuclear power plants are examined. More than a hundred software-hardware systems employing software and hardware from different manufacturers have been developed and introduced in this area. Design and functional solutions based on specific software-hardware systems are presented and comparative data on the apparatus and the use of the diversity principle are discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lamellar: A Rust-based Asynchronous Tasking and PGAS Runtime for High Performance Computing

Cybersecurity is one of the largest concerns in modern computing, impacting and dictating how governments, private corporations, and individuals interact with and live in an increasingly digital world. The NSA has recently released a memo [ 1] on “Software Memory Safety” where they highlight that both Microsoft and Google have stated around 70% of software vulnerabilities were due to memory safety issues. Although languages such as C and C++ provide freedom and flexibility with memory management, guaran- teeing safety falls mostly on the developer. The NSA recommends using “memory safe” languages whenever possible. In this paper we introduce Lamellar, an asynchronous tasking and PGAS HPC runtime written in Rust, one such "memory safe" language. We describe the entire Lamellar stack, from network interfaces to high- level abstractions such as distributed LamellarArrays and Active Messages. We conclude by showing comparable performance to legacy PGAS runtimes (e.g. OpenSHMEM) on a subset of the BALE kernel suite while maintaining strong memory safety principles.

HPC Software Systems, Rust Programming Language, P↗

Joint Development of SAS4A Code in Application to Oxide-fueled LFR Severe Accident Analysis

The scope of this project was to pursue specific SAS4A liquid-metal cooled reactor (LMR) safety analysis software extensions to simulate postulated accidents with fuel failures for oxide-fueled Lead-cooled Fast Reactors (LFRs). Since most U.S. LMR experience is on sodium-cooled fast reactor options based on past testing and operation experience with EBR-II and FFTF, the DOE’s legacy fast reactor safety analysis capabilities were focused on metal-fueled pool-type concepts with sodium coolant. In recent years, Westinghouse Electric Company (WEC) has decided to pursue an LFR design as one of their next generation nuclear technology options because of its favorable safety and economics attributes. Oxide fuel is considered among other fuel options due to previous WEC experience with this fuel form. Development of this new technology requires the availability of adequately accurate computational tools, some of which can be adapted from versions of similar software used for analysis of other LMRs. Although Argonne National Laboratory’s (ANL) SAS4A/SASSYS-1 safety analysis software suite (shortened as SAS4A code hereafter for brevity) has the basic capabilities to model LFR system designs, the SAS4A code modules used in the analysis of accidents with fuel/cladding failures lack appropriate models for the unique phenomena that govern as-irradiated oxide-fuel damage mechanisms in lead coolant. Therefore, the objective of this project was to extend the capabilities of SAS4A with mechanistic oxide-fuel failure models in lead coolant for margin to failure assessments, analysis of failure modes, location and timing of failures under different accident scenarios consistent with the whole-plant dynamic response including the reactivity feedback, and assessment of the potential for fuel damage propagation due to potential fission gas jet and fuel-fragment/molten fuel impingement to neighboring fuel pins in an assembly. This report provides mainly a summary of Argonne’s technical contributions in the joint project, but the reports and publications by the Participant team are included as references at the end of the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Make safety awareness a priority: Use a login software in your research facility

We report on a facility login software, whose objective is to improve safety in multi-user research facilities. Its most important safety features are: 1) blocks users from entering the lab after being absent for more than a predetermined number of days; 2) gives users a random safety quiz question, which they need to answer satisfactorily in order to use the facility; 3) blocks unauthorized users from using the facility afterhours; and 4) displays the current users in the facility. Besides restricting access to unauthorized users, the software keeps users mindful of key safety concepts. In addition, integration of the software with a door controller system can convert it into an effective physical safety mechanism. Depending on DOE approval, the code may be available as open source.

99 GENERAL AND MISCELLANEOUS↗

Using simulation to quantify the reliability of control software

More than two decades ago, Butler and Finelli examined the problem of experimentally demonstrating the reliability of safety critical software and concluded that it was impractical. We revisit this conclusion in the light of recent advances in computer system virtualization technology and the capability to link virtualization tools to simulation models of physical environments. A specific demonstration of testing for reliability is offered using software that is part of a building control system. Extrapolating the results of this demonstration, we conclude that experimental demonstrations of high reliability may now be feasible for some applications.

Nutaro, James J.↗

Thermal safety of ultrasound-enhanced ocular drug delivery: A modeling study

Purpose: Delivery of sufficient amounts of therapeutic drugs into the eye for treatment of various ocular diseases is often a challenging task. Ultrasound was shown to be effective in enhancing ocular drug delivery in the authors’ previous in vitro and in vivo studies. Methods: The study reported here was designed to investigate the safety of ultrasound application and its potential thermal effects in the eye using PZFlex modeling software. The safety limit in this study was set as a temperature increase of no more than 1.5 °C based on regulatory recommendations and previous experimental safety studies. Acoustic and thermal specifications of different human eye tissues were obtained from the published literature. The tissues of particular interest in this modeling safety study were cornea, lens, and the location of optic nerve in the posterior eye. Ultrasound application was modeled at frequencies of 400 kHz–1 MHz, intensities of 0.3–1 W/cm{sup 2}, and exposure duration of 5 min, which were the parameters used in the authors’ previous drug delivery experiments. The baseline eye temperature was 37 °C. Results: The authors’ results showed that the maximal tissue temperatures after 5 min of ultrasound application were 38, 39, 39.5, and 40 °C in the cornea, 39.5, 40, 42, and 43 °C in the center of the lens, and 37.5, 38.5, and 39 °C in the back of the eye (at the optic nerve location) at frequencies of 400, 600, 800 kHz, and 1 MHz, respectively. Conclusions: The ocular temperatures reached at higher frequencies were considered unsafe based on current recommendations. At a frequency of 400 kHz and intensity of 0.8 W/cm{sup 2} (parameters shown in the authors’ previous in vivo studies to be optimal for ocular drug delivery), the temperature increase was small enough to be considered safe inside different ocular tissues. However, the impact of orbital bone and tissue perfusion should be included in future modeling efforts to determine the safety of this method in the whole orbit especially regarding potential adverse optic nerve heating at the location of the bone.

60 APPLIED LIFE SCIENCES↗