Engineering PapersSearch

SEARCH · Engineering Papers

Results for “SiC Fiber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

28 records · Page 2

Advanced polymer impregnation and pyrolysis (PIP) of SiOC-based ceramic matrix composites (CMCs)

Silicon carbide (SiC) ceramic matrix composites (CMCs) are valued for their high-temperature properties, making them ideal for harsh environments. However, conventional polymer impregnation and pyrolysis (C-PIP) often result in porous composites and require numerous cycles for densification. This study introduces the advanced PIP (A-PIP) method using a crosslinked polycarbosiloxane (PCS) precursor to enhance densification efficiency. Five SiC CMCs were fabricated using C-PIP and A-PIP, with variations in fiber reinforcement and fiber coatings. A-PIP achieved up to 19 % higher density and 78 % lower porosity in 79–86 % less processing time compared to C-PIP. Moreover, SiC-SiOC composites with boron nitride-coated fibers showed significant improvements in tensile strength (11 MPa to 134 MPa) and strain at maximum strength (0.01–0.11 %), underscoring the role of weak fiber-matrix interfaces. In conclusion, these results demonstrate A-PIP's potential to produce dense, low-porosity SiC CMCs more efficiently, significantly reducing manufacturing time and costs.

36 MATERIALS SCIENCE

Water Vapor Resistant SiC/SiC Composite for Hydrogen-Based Turbines (Final Scientific Technical Report)

New material innovations are needed for the extreme environments of next generation, hydrogen-fueled turbine engines. Ceramic matrix composites (CMCs) offer high-temperature capability but are susceptible to degradation in high-temperature water vapor. Pratt & Whitney’s (P&W) baseline silicon carbide (SiC)/SiC CMC was initially applied to design a component in a hydrogen-fueled engine, verifying the existence of a design space and extracting boundary conditions to inform testing parameters. Several material innovations, including two fibers, interface coatings (IFC), and self-healing matrices (SHM), were investigated to improve high-temperature performance in water vapor. A boron-doped pyrocarbon (B-PyC) IFC and a SHM matrix with layers of zirconium nitride (ZrN) or zirconium diboride (ZrB 2 ) were developed to fabricate minicomposites with either standard Hi-Nicalon™ Type S (HNS) fibers or new Tyranno® SA4 fibers (SA4). The B-PyC IFC is functional but lacks in providing improved durability. A matrix consisting of thick layers of SiC and thin layers of ZrB 2 shows promise as a SHM that can effectively seal matrix cracks in this extreme environment. Minicomposites with HNS fibers generally outperform those with SA4 fibers.

08 HYDROGEN

Conceptual Designs for Irradiation Creep Testing of SiC in HFIR

Understanding irradiation creep of nuclear fuel cladding is important to properly size the initial fuel-cladding gap and understand when pellet-cladding contact is expected to occur due to a combination of fuel swelling and cladding creep-down. Irradiation creep also plays a role in relaxing stresses that develop in-pile. Silicon carbide fiber–reinforced silicon carbide matrix (SiC/SiC) composites are the leading long-term accident-tolerant fuel cladding concept for light-water reactors (LWRs). Although some limited data are available regarding irradiation creep of the individual constituents (fibers, matrix), data regarding irradiation creep of SiC/SiC composites are currently insufficient. Additional data regarding irradiation creep compliance and the rupture lifetime (combination of creep and slow crack growth) are needed to understand material limitations. This work describes the design and development of two irradiation vehicles that are being pursued for testing SiC/SiC concepts in the High Flux Isotope Reactor (HFIR). The first is a passive experiment, referred to as the PRECISE experiment, that leverages the constant coolant pressure of HFIR to compress a metallic bellows and provide a well-characterized load to drive creep in a SiC/SiC dog bone specimen. The total creep strain would be quantified post-irradiation by measuring dimensional changes of the specimen length as well as local dimensional changes within the gauge region. Non-stressed specimens would also be irradiated under the same conditions to provide an indication of dimensional changes due to radiation-induced swelling in the absence of creep. A second, more complex experiment, referred to as the INSITE experiment, is being designed in parallel that would use pneumatics to pressurize a metal bellows and linear variable differential transformers (LVDTs) to measure the specimen displacement in situ during irradiation. Such an experiment would provide significantly more data regarding the evolution of the creep compliance as a function of dose and applied stress within a single experiment but would require significantly more development time and cost to execute. The primary concern with the INSITE experiment is the accuracy, reliability, and expected lifetime of the LVDTs during irradiation at elevated temperatures. Efforts are being made to adjust the experiment design and operating procedure to limit LVDT temperatures and mitigate or otherwise compensate for uncertainties due to factors such as temperature fluctuations, creep in the surrounding structural materials, and drift of the LVDTs. This work describes the experiment designs, thermal and structural analysis that were performed to ensure that the desired temperature and stress conditions can be achieved, some initial sensitivity analyses to predict the evolution of the radiation-induced specimen displacements, and potential sources of uncertainty in the measurements. Out-of-pile testing is being performed in parallel to confirm that the test trains achieve the expected stress states in the specimens and do not result in prohibitive stress concentrators (e.g., in the grip regions) that might risk pre-mature failure. The PRECISE experiments are proceeding toward fabrication and assembly with HFIR insertion planned during fiscal year 2026. The INSITE experiment is progressing toward out-of-pile demonstrations, which will provide more conclusive evidence regarding the feasibility of executing these tests in HFIR or whether alternative displacement monitoring techniques may need to be considered.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Analyze the real-time performance of the optimized fiber-PTR instrument

An instrument to perform in-reactor, real-time thermal property measurements of nuclear fuels and materials was recently designed, optimized, and tested at Massachusetts Institute of Technology Research Reactor. It was the second insertion experiments of a total of two rounds. Here we report the collection and analysis of the real-time captured thermal diffusivity data on the preloaded SiC. With the optimized design, the instrument temperature had been successfully raised as we expected. Only one probe (the top one) returned real-time thermal diffusivity in a time span of approximately two days. Measured thermal diffusivity of the preloaded SiC was significantly lower than the literature value at the same temperature, indicating a significant influence from the irradiation induced microstructure damage. Meanwhile, the real-time thermal diffusivity value continuously reduced with time, indicating the dynamic microstructure evolution. The possible reasons of the probes that did not return data were hypothesized. The further optimization of the instrument with the objective to improve the measurement accuracy and instrument survivability is also discussed.

36 MATERIALS SCIENCE

A mean field homogenization model for the mechanical response of ceramic matrix composites

SiC/SiC composites offer exceptional mechanical stability at high temperatures and under irradiation. These ceramic matrix composites are therefore strong candidate materials for future nuclear energy applications. Their mechanical response, which exhibits pseudo-plasticity, is mediated by matrix cracking, fiber debonding, and fiber pull-out due to slip. Here, this study introduces a mechanistic model for the behavior of unidirectionally reinforced SiC/SiC composites. Specifically a mean field homogenization approach is proposed to account for all deformation and degradation modes during mechanical deformation. The homogenization scheme relies on a Mori Tanaka method that is extended to consider the effects of the coating’s elasto-plastic response on the development of micromechanical fields. Further, the model proposed introduces a method to effectively account for the role of localized damage (i.e., cracks) on mechanical fields within both the fiber and the matrix. Upon validating the model against experimental data, the roles of interface sliding, coating dimensions and intrinsic elastic response, as well as of microstructure (e.g. porosity, fiber volume fraction) are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Ceramic Composite Experimental Testing Status

Over recent years, ceramic matrix materials such as SiC–SiC and C–C have been gaining interest for use in fusion reactors, light water reactors (LWRs), and high-temperature reactors (HTRs). These materials are good candidates to operate in very high temperature and moderate to high radiation environments. The evaluation of composite materials, in general, is challenging because of variations in precursor materials, variations in the fabrication process across fabricators, and the wide range of potential fiber architectures, to name a few. However, the need to evaluate neutron-irradiated properties adds another layer of complexity, which includes cost, timeline, and specimen size limitations (often associated with irradiation testing). A qualification methodology for the use of ceramic composites is provided in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Section III-5-HHB. The methodology is supported by ASTM International (ASTM) guides, which provide a pathway to accomplish this effort. Part of the qualification strategy is for the designer to collect material property data on environmental conditions representative of its design envelope. These data include irradiation effects. This report presents an experimental study and test campaign developed to partially address this gap by providing initial mechanical and physical property data required for design. A variety of different materials using different manufacturing techniques are considered as part of this campaign. The test plan suggests performing a screening or partial irradiation study to assist the designer during the material selection process. The designer can then perform a more comprehensive qualification study if the material performance is promising. This work focuses on the status of the specimen preparations (machining of samples), the current test methods and failure analysis as well as the preparation of irradiation vehicles for the irradiation campaign. The irradiation will be performed at Oak Ridge National Laboratory (ORNL) in the High Flux Isotope Reactor (HFIR) and at Idaho National Laboratory (INL) in the Advanced Test Reactor (ATR).

22 GENERAL STUDIES OF NUCLEAR REACTORS

The Influence of Residual Copper Catalyst on the Polymer-to-Ceramic Conversion of a Click-Derived Polycarbosilane

Preceramic polymers (PCPs) are a key class of materials for the preparation of advanced ceramic components. Following conventional polymer processing and subsequent pyrolysis, polymer-derived ceramic (PDC) fibers, monoliths, and composites offer novel engineering opportunities for aerospace applications. Despite the rapidly emerging commercial applications of PDCs, many basic scientific questions remain regarding the structural transformation of the polymer to the final ceramic and how processing variables affect PDC materials properties. PCPs prepared using a mild and scalable copper (Cu) catalyzed azide/alkyne “click” reaction have been demonstrated as a unique class of material that can bind with transition metals, ultimately producing ultrahigh temperature ceramics (UHTCs) upon pyrolysis. Unexpectedly, it was found that the removal of residual Cu catalyst from a model click-derived polycarbosilane PCP significantly reduced the ceramic yield during pyrolysis. Herein, we report the influence of Cu impurities on polycarbosilane-derived SiC ceramics and present a mechanistic understanding of the unintended role of Cu in the polymer-to-ceramic conversion process. Synchrotron-based scattering and spectroscopy methods were implemented to track the evolution of different atomic species and local structures as well as the influence of Cu toward atomic-scale structures in the final ceramics. It was determined that Cu impurities catalyze the formation of silicon carbide through the formation of an intermediate molten copper/copper silicide, ultimately increasing the ceramic yield. Overall, this contribution highlights the need to carefully assess the interplay between the chemistries needed for PCP synthesis and their potential influence on final PDCs following processing.

Ponder, Jr., James F. [Air Force Research Laborato

Proliferated Resilient Economical Half-Meter Aperture Space Telescopes (PREEMPT)

The PREEMPT LDRD was motivated by a major national need for better space-based imaging systems that are both high performing and affordable for the US Government. Current optical payloads for intelligence, surveillance and reconnaissance (ISR) and space domain awareness (SDA) missions can cost hundreds of millions of dollars and take years to develop, which makes it difficult to build the large constellations required for persistent, world-wide coverage. To address this, the team aimed to advance a different kind of large-aperture (>25 cm) telescope, called a monolithic telescope, in which key optical surfaces are built into a single piece of fused silica. This design greatly reduces payload and spacecraft complexity, the need for precision focus actuators, improves mechanical and thermal robustness, and lowers cost when compared with traditional Cassegrain telescopes that rely on many precisely aligned components. The project focused on five primary thrusts. The first thrust was to advance the concept of a V10, 25 cm, monolithic telescope forward from optical design to flight-ready stage. This was accomplished in partnership with Optimax, who delivered the first test unit in the early stages of the LDRD. The team developed several technologies necessary for this optic to be integrated into a flight demonstration. These include carbon fiber housings, highly detailed structural and thermal models and stress-reducing elastic averaging Hirth groove designs. These technologies resulted in a successful maturation of the optic, which is now slated to fly in late 2026/early 2027 for a demonstration mission. The second thrust was to advance the manufacturability of these optics. In collaboration with NIF’s optical manufacturing shop, we reduced polishing time from 480 hours to 65 hours through the implementation of optimized processes and new tools. The NIF team utilized a conceptual V8 (18 cm) optic to demonstrate this optimization, though it can be applied to the rest of the monolithic optic portfolio. Third, the team developed the first conceptual V20 (50 cm) payload, which is slated to be the next generation of LLNL optical payload systems. A set of structural, dynamic and thermal simulations were performed to identify potential challenges in the future development of this payload. Early-stage simulations suggest the payload is feasible, though thermal management will be the key focus area to maintain optimal performance. Fourth, a non-linear model of Viton was developed, to further enhance the reliability of our structural and dynamic models for future payloads. Viton acts as the primary interface material between the optic and its housing. Lastly, the team focused on successfully displaying the feasibility of using additively manufactured metal composites for optical space payloads. The team successfully demonstrated layer by layer deposition of Al-SiC composites, which have highly tunable structural and coefficient of thermal expansion (CTE) properties. These are crucial for optical payloads because CTE mismatch is one of the causes for degraded optical performance for telescopes in orbit. Overall, the work showed that monolithic telescopes could become a practical, lower-cost path to high-resolution space imaging for both national security and scientific missions.

42 ENGINEERING

Sub-2 Kelvin Characterization of Nitrogen-Vacancy Centers in Silicon Carbide Nanopillars

The development of efficient quantum communication technologies depends on the innovation in multiple layers of its implementation, a challenge we address from the fundamental properties of the physical system at the nanoscale to the instrumentation level at the macroscale. We select a promising near-infrared quantum emitter, the nitrogen-vacancy (NV) center in 4H-SiC, and integrate it, at an ensemble level, with nanopillar structures that enhance photon collection efficiency into an objective lens. Moreover, changes in collection efficiency in pillars compared to bulk can serve as indicators of color center orientation in the lattice. To characterize NV center properties at the unprecedented sub-2 K temperatures, we incorporate compatible superconducting nanowire single photon detectors inside the chamber of an optical cryostat and create the ICECAP, the Integrated Cryogenic system for Emission, Collection And Photon detection. ICECAP measurements show no significant line-width broadening of NV ensemble emission and up to 14-fold enhancement in collected emission. With additional filtering, we measure emitter lifetimes of NV centers in a basal ( hk ) and axial ( kk ) orientation, unveiling their cryogenic values of 2.2 and 2.8 ns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH