Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SiB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Soil Surface Runoff Scheme for Improving Land-Hydrology and Surface Fluxes in Simple SiB (SSiB)

Evapotranspiration on land is hard to measure and difficult to simulate. On the scale of a GCM grid, there is large subgrid-scale variability of orography, soil moisture, and vegetation. Our hope is to be able to tune the biophysical constants of vegetation and soil parameters to get the most realistic space-averaged diurnal cycle of evaporation and its climatology. Field experiments such as First ISLSCP Field Experiment (FIFE), Boreal Ecosystem-Atmosphere Study (BOREAS), and LBA help a great deal in improving our evapotranspiration schemes. However, these improvements have to be matched with, and coupled to, consistent improvement in land-hydrology; otherwise, the runoff problems will intrinsically reflect on the soil moisture and evapotranspiration errors. Indeed, a realistic runoff simulation also ensures a reasonable evapotranspiration simulation provided the precipitation forcing is reliable. We have been working on all of the above problems to improve the simulated hydrologic cycle. Through our participation in the evaluation and intercomparison of land-models under the behest of Global Soil Wetness Project (GSWP), we identified a few problems with Simple SiB (SSIB; Xue et al., 1991) hydrology in regions of significant snowmelt. Sud and Mocko (1999) show that inclusion of a separate snowpack model, with its own energy budget and fluxes with the atmosphere aloft and soil beneath, helps to ameliorate some of the deficiencies of delayed snowmelt and excessive spring season runoff. Thus, much more realistic timing of melt water generation was simulated with the new snowpack model in the subsequent GSWP re-evaluations using 2 years of ISLSCP Initiative I forcing data for 1987 and 1988. However, we noted an overcorrection of the low meltwater infiltration of SSiB. While the improvement in snowmelt timing was found everywhere, the snowmelt infiltration has became excessive in some regions, e.g., Lena river basin. This leads to much reduced runoff in many basins as compared to observations. We believe this is a consequence of neglect of the influence of subgrid-scale variations in orography that affects the production of surface runoff.

Sud, Y. C.↗

Materials Data on SiB by Materials Project

BSi is Wurtzite structured and crystallizes in the hexagonal P6_3mc space group. The structure is three-dimensional. B is bonded to four equivalent Si atoms to form corner-sharing BSi4 tetrahedra. There are one shorter (1.99 Å) and three longer (2.06 Å) B–Si bond lengths. Si is bonded to four equivalent B atoms to form corner-sharing SiB4 tetrahedra.

36 MATERIALS SCIENCE↗

Materials Data on Nb10(SiB)3 by Materials Project

Nb10(BSi)3 crystallizes in the orthorhombic Fmm2 space group. The structure is three-dimensional. there are four inequivalent Nb+2.10+ sites. In the first Nb+2.10+ site, Nb+2.10+ is bonded to two B3- and three Si4- atoms to form NbSi3B2 trigonal bipyramids that share corners with four equivalent NbSi3B3 octahedra, corners with twelve NbSi3B2 trigonal bipyramids, edges with seven NbSi3B2 trigonal bipyramids, faces with two equivalent NbSi3B3 octahedra, and a faceface with one NbSi3B2 trigonal bipyramid. The corner-sharing octahedra tilt angles range from 42–62°. There are one shorter (2.51 Å) and one longer (2.53 Å) Nb–B bond lengths. There are a spread of Nb–Si bond distances ranging from 2.54–2.69 Å. In the second Nb+2.10+ site, Nb+2.10+ is bonded to three B3- and two equivalent Si4- atoms to form NbSi2B3 trigonal bipyramids that share corners with four equivalent NbSi3B3 octahedra, corners with twelve NbSi3B2 trigonal bipyramids, edges with seven NbSi3B2 trigonal bipyramids, faces with two equivalent NbSi3B3 octahedra, and a faceface with one NbSi2B3 trigonal bipyramid. The corner-sharing octahedra tilt angles range from 42–60°. There are two shorter (2.44 Å) and one longer (2.49 Å) Nb–B bond lengths. Both Nb–Si bond lengths are 2.69 Å. In the third Nb+2.10+ site, Nb+2.10+ is bonded to two equivalent B3- and three Si4- atoms to form NbSi3B2 trigonal bipyramids that share corners with four equivalent NbSi3B3 octahedra, corners with twelve NbSi3B2 trigonal bipyramids, edges with seven NbSi3B2 trigonal bipyramids, faces with two equivalent NbSi3B3 octahedra, and a faceface with one NbSi3B2 trigonal bipyramid. The corner-sharing octahedra tilt angles range from 44–63°. Both Nb–B bond lengths are 2.44 Å. There are one shorter (2.61 Å) and two longer (2.72 Å) Nb–Si bond lengths. In the fourth Nb+2.10+ site, Nb+2.10+ is bonded to three B3- and three Si4- atoms to form distorted NbSi3B3 octahedra that share corners with six equivalent NbSi3B3 octahedra, corners with sixteen NbSi3B2 trigonal bipyramids, and faces with eight NbSi3B2 trigonal bipyramids. The corner-sharing octahedra tilt angles range from 2–56°. There are a spread of Nb–B bond distances ranging from 2.48–2.57 Å. There are one shorter (2.57 Å) and two longer (2.94 Å) Nb–Si bond lengths. There are two inequivalent B3- sites. In the first B3- site, B3- is bonded in a 9-coordinate geometry to eight Nb+2.10+ and one B3- atom. The B–B bond length is 2.06 Å. In the second B3- site, B3- is bonded in a 9-coordinate geometry to eight Nb+2.10+ and one Si4- atom. The B–Si bond length is 2.19 Å. There are two inequivalent Si4- sites. In the first Si4- site, Si4- is bonded in a 9-coordinate geometry to eight Nb+2.10+ and one B3- atom. In the second Si4- site, Si4- is bonded in a 10-coordinate geometry to ten Nb+2.10+ atoms.

36 MATERIALS SCIENCE↗

A simple biosphere model (SiB) for use within general circulation models

A simple realistic biosphere model for calculating the transfer of energy, mass and momentum between the atmosphere and the vegetated surface of the earth has been developed for use in atmospheric general circulation models. The vegetation in each terrestrial model grid is represented by an upper level, representing the perennial canopy of trees and shrubs, and a lower level, representing the annual cover of grasses and other heraceous species. The vegetation morphology and the physical and physiological properties of the vegetation layers determine such properties as: the reflection, transmission, absorption and emission of direct and diffuse radiation; the infiltration, drainage, and storage of the residual rainfall in the soil; and the control over the stomatal functioning. The model, with prescribed vegetation parameters and soil interactive soil moisture, can be used for prediction of the atmospheric circulation and precipitaion fields for short periods of up to a few weeks.

Sellers, P. J.↗

A brief description of the simple biosphere model (SiB)

A biosphere model for calculating the transfer of energy, mass, and momentum between the atmosphere and the vegetated surface of the Earth was designed for atmospheric general circulation models. An upper vegetation layer represents the perennial canopy of trees or shrubs, a lower layer represents the annual ground cover of grasses and other herbacious species. The local coverage of each vegetation layer may be fractional or complete but as the individual vegetation elements are considered to be evenly spaced, their root systems are assumed to extend uniformly throughout the entire grid-area. The biosphere has seven prognostic physical-state variables: two temperatures (one for the canopy and one for the ground cover and soil surface); two interception water stores (one for the canopy and one for the ground cover); and three soil moisture stores (two of which can be reached by the vegetation root systems and one underlying recharge layer into and out of which moisture is transferred only by hydraulic diffusion).

Sellers, P. J.↗

Preliminary analyses of SIB-B radar data for recent Hawaii lava flows

The Shuttle Imaging Radar (SIR-B) experiment acquired two L-band (23 cm wavelength) radar images (at about 28 and 48 deg incidence angles) over the Kilauea Volcano area of southeastern Hawaii. Geologic analysis of these data indicates that, although aa lava flows and pyroclastic deposits can be discriminated, pahoehoe lava flows are not readily distinguished from surrounding low return materials. Preliminary analysis of data extracted from isolated flows indicates that flow type (i.e., aa or pahoehoe) and relative age can be determined from their basic statistics and illumination angle.

Kaupp, V. H.↗

Comparison of whole-field simultaneous integrated boost VMAT and IMRT in the treatment of nasopharyngeal cancer

To study the feasibility of using volumetric-modulated arc therapy (VMAT) to deliver whole-field simultaneous integrated boost (WF-SIB) to treat patients with nasopharyngeal cancer (NPC). WF-SIB intensity-modulated radiotherapy (IMRT) plans, one-arc WF-SIB VMAT plans, and two-arc WF-SIB VMAT plans were generated with identical objective functions for 8 patients with NPC of various stages. Isodose distributions and dose-volume histograms were evaluated. Dosimetric and biological quality indices of clinical target volume (CTV) and organs at risk (OARs) were calculated to study the optimization capability of these 3 modalities in the treatment of patients with NPC. The optimization time, delivery time, required monitor units (MUs), and delivery accuracy were also compared to investigate the feasibility of these 3 modalities. There was no significant difference (p = 0.92) in target coverage (TC) between WF-SIB IMRT (99.00 ± 0.79) and two-arc WF-SIB VMAT (97.98 ± 1.29). However, both had higher TC than one-arc VMAT plans (89.92 ± 6.32, p < 0.01). IMRT demonstrated the best protection of the spinal cord, whereas two-arc VMAT showed the minimum D{sub max} to OARs. No other significant differences were observed among these 3 modalities on CTV coverage and OAR sparing. The delivery and MU efficiency of one-arc and two-arc WF-SIB VMAT were greatly improved compared with WF-SIB IMRT. The optimization time of one-arc and two-arc WF-SIB VMAT plans were 5 and 10 times greater than that of WF-SIB IMRT, respectively. The delivery accuracy of WF-SIB VMAT was not affected by the increased freedom. For patients with NPC, one-arc WF-SIB VMAT might not be able to achieve sufficient TC, whereas two-arc WF-SIB VMAT was able to achieve reasonable TC. No significant advantage on OAR protection was demonstrated by VMAT compared with IMRT. WF-SIB VMAT has significantly shorter delivery times, but WF-SIB IMRT may still be the first treatment choice for patients with NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Interphases in Sodium-Ion Batteries

Sodium-ion batteries (SIBs) as economical high energy alternatives to lithium-ion batteries (LIBs) have received significant attention for large-scale energy storage in the last few years. While the efforts of developing SIBs have benefited from the knowledge learned in LIBs, thanks to the apparent proximity between Na-ion and Li-ion, the unique physical and chemical properties of Na-ion also distinctly differ itself from Li-ion. It is expected SIBs have drastically different electrode material structure, solvation-de-solvation behavior, electrode-electrolyte interphase stability, ion transfer property, and hence electrochemical performance of batteries. In this review, we comprehensively summarize the current understanding of the anode solid-electrolyte-interphase (SEI) and cathode cathode-electrolyte-interphase (CEI) in SIBs, with an emphasis on how the tuning of the stability and ion transfer properties of interphases fundamentally determines the reversibility and efficiency of electrochemical reactions. Through these carefully screened references, we intend to reveal the intrinsic correlation between the properties/functionalities of the interphases and the electrochemical performances of batteries.

Song, Junhua↗

A Prospective Trial of Intensity Modulated Radiation Therapy (IMRT) Incorporating a Simultaneous Integrated Boost for Prostate Cancer: Long-term Outcomes Compared With Standard Image Guided IMRT

Purpose: This report describes the long-term outcomes of a prospective trial of intensity modulated radiation therapy (IMRT), integrating a {sup 111}In capromab pendetide (ProstaScint) scan-directed simultaneous integrated boost (SIB) for localized prostate cancer. Methods and Materials: Seventy-one patients with T1N0M0 to T4N0M0 prostate cancer were enrolled, and their ProstaScint and pelvic computed tomography scans were coregistered for treatment planning. The entire prostate received 75.6 Gy in 42 fractions with IMRT, whereas regions of increased uptake on ProstaScint scans received 82 Gy as an SIB. Patients with intermediate- and high-risk disease also received 6 months and 12 months of adjuvant hormonal therapy, respectively. Results: The study enrolled 31 low-, 30 intermediate-, and 10 high-risk patients. The median follow-up was 120 months (range, 24-150 months). The 10-year biochemical control rates were 85% for the entire cohort and 84%, 84%, and 90% for patients with low-, intermediate-, and high-risk disease, respectively. The 10-year survival rate of the entire cohort was 69%. Pretreatment prostate-specific antigen level >10 ng/mL and boost volume of >10% of the prostate volume were significantly associated with poorer biochemical control and survival. The outcomes were compared with those of a cohort of 302 patients treated similarly but without the SIB and followed up for a median of 91 months (range, 6-138 months). The 5- and 10-year biochemical control rates were 86% and 61%, respectively, in patients without the SIB compared with 94% and 85%, respectively, in patients in this trial who received the SIB (P=.02). The cohort that received an SIB did not have increased toxicity. Conclusions: The described IMRT strategy, integrating multiple imaging modalities to administer 75.6 Gy to the entire prostate with a boost dose of 82 Gy, was feasible. The addition of the SIB was associated with greater biochemical control but not toxicity. Modern imaging technology can be used to locally intensify the dose to tumors and spare normal tissues, producing very favorable long-term biochemical disease control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dosimetric evaluation of dose escalation for the radical treatment of locally advanced vulvar cancer by intensity-modulated radiation therapy

The purpose of this planning study was to determine whether intensity-modulated radiation therapy (IMRT) reduces the radiation dose to organs at risk (OAR) when compared with 3D conventional radiation therapy (3D-CRT) in patients with vulvar cancer treated by irradiation. This study also investigated the use of sequential IMRT boost (seq-IMRT) and simultaneous integrated boost (SIB-IMRT) for dose escalation in the treatment of locally advanced vulvar cancer. Five vulvar cancer patients treated in the postoperative setting and 5 patients treated with definitive intent (def-group) were evaluated. For the postoperative group, 3D-CRT and IMRT plans to a total dose (TD) of 45 Gy were generated. For the def-group, 4 plans were generated: a 3D-CRT and an IMRT plan to a TD of 56.4 Gy, a SIB-IMRT plan to a TD of 56 Gy, and a SIB-IMRT with dose escalation (SIB-IMRT-esc): TD of 67.2 Gy. Mean dose and dose-volume histograms were compared using Student's t-test. IMRT significantly (all p < 0.05) reduced the D{sub mean}, V30, and V40 for all OAR in the adjuvant setting. The V45 was also significantly reduced for all OAR except the bladder. For patients treated in the def-group, all IMRT techniques significantly reduced the D{sub mean}, V40, and V45 for all OAR. The mean femur doses with SIB-IMRT and SIB-IMRT-esc were 47% and 49% lower compared with 3D-CRT. SIB-IMRT-esc reduced the doses to the OAR compared with seq-3D-CRT but increased the D{sub max.} for the small bowel, rectum, and bladder. IMRT reduces the dose to the OAR compared with 3D-CRT in patients with vulvar cancer receiving irradiation to a volume covering the vulvar region and nodal areas without compromising the dosimetric coverage of the target volume. IMRT for vulvar cancer is feasible and an attractive option for dose escalation studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer

Purpose: To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer.Method: Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermoluminescent dosimeter measurements in an anthropomorphic phantom in which the positions of radiosensitive organs were delineated. Five treatment deliveries were investigated: (i) conventional tangential field whole breast radiotherapy (WBRT), (ii) noncoplanar conformal delivery applicable to accelerated partial beast irradiation (APBI), (iii) two-volume simultaneous integrated boost (SIB) treatment, (iv) forward planned three-volume SIB, and (v) inverse-planned three volume SIB. Conformal and intensity modulated radiotherapy methods were used to plan the complex treatments. Techniques spanned the range from simple methods appropriate for patient cohorts with a low cancer recurrence risk to complex plans relevant to cohorts with high recurrence risk. Delineated organs at risk included brain, salivary glands, thyroid, contralateral breast, left and right lung, esophagus, stomach, liver, colon, and bladder. Biological Effects of Ionizing Radiation (BEIR) VII cancer incidence models were applied to the measured mean organ doses to determine lifetime attributable risk (LAR) for ages at exposure from 35 to 80 yr according to radiotherapy techniques, and included dose from the CBCT imaging. Results: All LAR decreased with age at exposure and were lowest for brain, thyroid, liver, and bladder (<0.1%). There was little dependence of LAR on radiotherapy technique for these organs and for colon and stomach. LAR values for the lungs for the three SIB techniques were two to three times those from WBRT and APBI. Uncertainties in the LAR models outweigh any differences in lung LAR between the SIB methods. Constraints in the planning of the SIB methods ensured that contralateral breast doses and LAR were comparable to WBRT, despite their added complexity. The smaller irradiated volume of the ABPI plan contributed to a halving of LAR for contralateral breast compared with the other plan types. Daily image guided radiotherapy (IGRT) for a left breast protocol using kilovoltage CBCT contributed <10% to LAR for the majority of organs, and did not exceed 22% of total organ dose. Conclusions: Phantom measurements and calculations of LAR from the BEIR VII models predict that complex breast radiotherapy techniques do not increase the theoretical risk of second cancer incidence for organs distant from the treated breast, or the contralateral breast where appropriate plan constraints are applied. Complex SIB treatments are predicted to increase the risk of second cancer incidence in the lungs compared to standard whole breast radiotherapy; this is outweighed by the threefold reduction in 5 yr local recurrence risk for patients of high risk of recurrence, and young age, from the use of radiotherapy. APBI may have a favorable impact on risk of second cancer in the contralateral breast and lung for older patients at low risk of recurrence. Intensive use of IGRTincreased the estimated values of LAR but these are dominated by the effect of the dose from the radiotherapy, and any increase in LAR from IGRT is much lower than the models' uncertainties.

60 APPLIED LIFE SCIENCES↗

Effects of implementing the Simple Biosphere Model in a general circulation model

The Simple Biosphere Model (SiB) of Sellers et al., was designed to simulate the interactions between the earth's land surface and the atmosphere by treating the vegetation explicitly and realistically, thereby incorporating the biophysical controls on the exchanges of radiation, momentum, sensible and latent heat between the two systems. This paper describes the steps taken to implement SiB in a modified version of the National Meteorological Center's global spectral general circulation model (GCM) and explores the impact of the implementation on the simulated land surface fluxes and near-surface meteorological conditions. The coupled model (SiB-GCM) was used to produce summer and winter simulations. The same GCM was used with a conventional hydrological model (Ctl-GCM) to produce comparable 'control' summer and winter simulations for comparison. It was found that SiB-GCM produced a more realistic partitioning of energy at the land surface than Ctl-GCM. Generally, SiB-GCM, produced more sensible heat flux and less latent heat flux over vegetated land than did Ctl-GCM and this resulted in a much deeper daytime planetary boundary layer and reduced precipitation rates over the continents in SiB-GCM. In the summer simulation, the 200 mb jet stream was slightly weakened in the SiB-GCM relative to the Ctl-GCM results and analyses made from observations.

Sato, N.↗

A Perspective on Pathways Toward Commercial Sodium‐Ion Batteries

Lithium-ion batteries (LIBs) have been widely adopted in the automotive industry, with an annual global production exceeding 1000 GWh. Despite their success, the escalating demand for LIBs has created concerns on supply chain issues related to key elements, such as lithium, cobalt, and nickel. Sodium-ion batteries (SIBs) are emerging as a promising alternative due to the high abundance and low cost of sodium and other raw materials. Nevertheless, the commercialization of SIBs, particularly for grid storage and automotive applications, faces significant hurdles. This perspective article aims to identify the critical challenges in making SIBs viable from both chemical and techno-economic perspectives. First, a brief comparison of the materials chemistry, working mechanisms, and cost between mainstream LIB systems and prospective SIB systems is provided. The intrinsic challenges of SIBs regarding storage stability, capacity utilization, cycle stability, calendar life, and safe operation of cathode, electrolyte, and anode materials are discussed. Furthermore, issues related to the scalability of material production, materials engineering feasibility, and energy-dense electrode design and fabrication are illustrated. Finally, promising pathways are listed and discussed toward achieving high-energy-density, stable, cost-effective SIBs.

25 ENERGY STORAGE↗

Role of Intensity-Modulated Radiotherapy in Reducing Toxicity in Dose Escalation for Localized Prostate Cancer

Purpose: To compare the acute and late gastrointestinal (GI) and genitourinary (GU) toxicity in prostate cancer patients treated to a total dose of 78 Gy with either a three-conformal radiotherapy technique with a sequential boost (SEQ) or a simultaneous integrated boost using intensity-modulated radiotherapy (SIB-IMRT). Patients and Methods: A total of 78 prostate cancer patients participating in the randomized Dutch trial comparing 68 Gy and 78 Gy were the subject of this analysis. They were all treated at the same institution to a total dose of 78 Gy. The median follow-up was 76 and 56 months for the SEQ and SIB-IMRT groups, respectively. The primary endpoints were acute and late GI and GU toxicity. Results: A significantly lower incidence of acute Grade 2 or greater GI toxicity occurred in patients treated with SIB-IMRT compared with SEQ (20% vs. 61%, p = 0.001). For acute GU toxicity and late GI and GU toxicity, the incidence was lower after SIB-IMRT, but these differences were not statistically significant. No statistically significant difference were found in the 5-year freedom from biochemical failure rate (Phoenix definition) between the two groups (70% for the SIB-IMRT group vs. 61% for the SEQ group, p = 0.3). The same was true for the 5-year freedom from clinical failure rate (90% vs. 72%, p = 0.07). Conclusion: The results of our study have shown that SIB-IMRT reduced the toxicity without compromising the outcome in patients with localized prostate cancer treated to 78 Gy radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole Brain Irradiation With Hippocampal Sparing and Dose Escalation on Multiple Brain Metastases: A Planning Study on Treatment Concepts

Purpose: To develop a new treatment planning strategy in patients with multiple brain metastases. The goal was to perform whole brain irradiation (WBI) with hippocampal sparing and dose escalation on multiple brain metastases. Two treatment concepts were investigated: simultaneously integrated boost (SIB) and WBI followed by stereotactic fractionated radiation therapy sequential concept (SC). Methods and Materials: Treatment plans for both concepts were calculated for 10 patients with 2-8 brain metastases using volumetric modulated arc therapy. In the SIB concept, the prescribed dose was 30 Gy in 12 fractions to the whole brain and 51 Gy in 12 fractions to individual brain metastases. In the SC concept, the prescription was 30 Gy in 12 fractions to the whole brain followed by 18 Gy in 2 fractions to brain metastases. All plans were optimized for dose coverage of whole brain and lesions, simultaneously minimizing dose to the hippocampus. The treatment plans were evaluated on target coverage, homogeneity, and minimal dose to the hippocampus and organs at risk. Results: The SIB concept enabled more successful sparing of the hippocampus; the mean dose to the hippocampus was 7.55 {+-} 0.62 Gy and 6.29 {+-} 0.62 Gy, respectively, when 5-mm and 10-mm avoidance regions around the hippocampus were used, normalized to 2-Gy fractions. In the SC concept, the mean dose to hippocampus was 9.8 {+-} 1.75 Gy. The mean dose to the whole brain (excluding metastases) was 33.2 {+-} 0.7 Gy and 32.7 {+-} 0.96 Gy, respectively, in the SIB concept, for 5-mm and 10-mm hippocampus avoidance regions, and 37.23 {+-} 1.42 Gy in SC. Conclusions: Both concepts, SIB and SC, were able to achieve adequate whole brain coverage and radiosurgery-equivalent dose distributions to individual brain metastases. The SIB technique achieved better sparing of the hippocampus, especially when a10-mm hippocampal avoidance region was used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transforming CO 2 to Porous Carbon as a High-Performing Sodium-Ion Battery Anode via Electrochemical Reduction in Molten Carbonates

The prevalence of sodium over lithium prompts exploration of sodium-ion batteries (SIBs) as a viable alternative to lithium-ion batteries (LIBs). Hard carbon has emerged as a promising anode material for SIBs, yet its synthesis poses sustainability challenges and emits pollutants. Here, in this study, we introduce CO 2 -derived porous carbon (graphitic and amorphous) as an anode for SIBs via electrochemical reduction of CO 2 in a molten eutectic carbonate salt at a lower temperature that yields materials with controlled microstructure, morphology, and porosity conducive to energy storage. Our CO 2 -derived carbon demonstrates remarkable specific capacity, superior rate capability, and stable cycling performance as a SIB anode. This innovative strategy harnesses waste CO 2 toward advancing SIB energy technology.

CO2-derived carbon↗