Analysis of PV Advanced Inverter Functions and Setpoints under Time Series Simulation.

Utilities are increasingly concerned about the potential negative impacts distributed PV may have on the operational integrity of their distribution feeders. Some have proposed novel methods for controlling a PV system's grid - tie inverter to mitigate poten tial PV - induced problems. This report investigates the effectiveness of several of these PV advanced inverter controls on improving distribution feeder operational metrics. The controls are simulated on a large PV system interconnected at several locations within two realistic distribution feeder models. Due to the time - domain nature of the advanced inverter controls, quasi - static time series simulations are performed under one week of representative variable irradiance and load data for each feeder. A para metric study is performed on each control type to determine how well certain measurable network metrics improve as a function of the control parameters. This methodology is used to determine appropriate advanced inverter settings for each location on the f eeder and overall for any interconnection location on the feeder.

14 SOLAR ENERGY↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Real-Time Control of an Ensemble of Heterogeneous Resources

This paper focuses on the problem of controlling an ensemble of heterogeneous resources connected to an electrical grid at the same point of common coupling (PCC). The controller receives an aggregate power setpoint for the ensemble in real time and tracks this setpoint by issuing individual optimal setpoints to the resources. The resources can have continuous or discrete nature (e.g., heating systems consisting of a finite number of heaters that each can be either switched on or off) and/or can be highly uncertain (e.g., photovoltaic (PV) systems or residential loads). A naive approach would lead to a stochastic mixed-integer optimization problem to be solved at the controller at each time step, which might be infeasible in real time. Instead, we allow the controller to solve a continuous convex optimization problem and compensate for the errors at the resource level by using a variant of the well-known error diffusion algorithm. We give conditions guaranteeing that our algorithm tracks the power setpoint at the PCC on average while issuing optimal setpoints to individual resources. We illustrate the approach numerically by controlling a collection of batteries, PV systems, and discrete loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Inverter Twin Model for Anomaly Detection

Smart inverters connected to a communication network are vulnerable to various anomalies in the form of cyberattacks. In this paper, a self-security approach is implemented using the digital twin concept for smart inverters. The digital twin is formed using the inverter’s dynamic model. Then, the incoming setpoints are autonomously examined using the digital twin, and only the safe setpoints are engaged to the inverter’s local controller. This paper demonstrates the details of the self-security algorithm and how the inverter’s digital twin is formed. In particular, the stable and unstable operation region is experimentally verified by changing the power setpoints engaged to the local controller, using a laboratory setup including a three-phase 1.5-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative power grid emulator. The results demonstrate that the digital twin model can potentially protect inverters from abnormal operation by examining the incoming commands (new setpoints) using the inverter’s digital twin before engaging the setpoints to the local controller.

Hossen, Tareq↗

Digital Twin for Self-Security of Smart Inverters

Smart inverters connected to a communication network are susceptible to man-in-the-middle attacks. In this paper, a self-security approach is implemented using the digital twin concept for smart inverters. The digital twin is formed using the inverter’s normal operating region and the inverter’s dynamic model. Then, the incoming setpoints are autonomously examined using the digital twin, and only the safe setpoints are engaged to the inverter’s local controller. This paper demonstrates how the inverter’s normal operating region and dynamic model are formed. In particular, the normal operation region is experimentally verified by changing the P and Q setpoints engaged to the local controller, using a laboratory setup including a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative power grid emulator. The results demonstrate that the self-security technique can potentially protect inverters from man-in-the-middle attacks by examining the incoming commands (new setpoints) using the inverter’s digital twin before engaging the setpoints to the local controller.

Hossen, Tareq↗

Resident Tolerance to Transitional Temperature Deviation in Smart Communities

Choosing the right HVAC system or the right algorithm of implementing demand response may create significant energy and environmental gains while maintaining resident comfort. But these questions are closely related to the concept of user comfort, which in turn requires a reasonable fit between user preferences and temperature setpoints. While setting the temperature right is a well-researched question, systems in transition from one setpoint to another are currently not thoroughly addressed in research. But how tolerant the residents really are if a system spends a large share of time outside of the comfort setpoint. This study gives some early insights on how the deviation of temperature from the setpoint affect perceived resident comfort. We use two weeks of data for a smart neighborhood located in Atlanta, GA. We find that the system spends 20% - 50% of time deviating from the setpoint by more than 1℉. However, we do not find that increasing deviations cause resident complaints or increasing overrides.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application Deconfliction Characterization and Alternatives Analysis

This report provides an overview of the domain space and solution techniques that could be used to create a robust, flexible app deconfliction service. Three approaches are reviewed with summaries of the characteristics, elements, and results from preliminary demonstrations of solution techniques based on each approach: 1) rules and heuristics, 2) cooperation, and 3) optimization. The strengths and weaknesses of each solution technique were explored through a set of numerical demonstrations on modified IEEE 123 node and 9500 node test feeders. An alternatives analysis of individual deconfliction elements was performed with each solution technique element evaluated against criteria reflecting the dynamic app environment, need to balance app objectives, and scalability issues versus the number of applications, setpoints, and distributed control areas. It is anticipated that a combined solution for a GridAPPS-D Deconfliction Service can be formulated using a combination of elements from each solution technique. The combined solution would combine 1) device control budgets to reduce the size of the solution space by constraining system setpoints to those will not result in accelerated degradation of physical assets, 2) system operations rules to constrain the solution space by eliminating setpoints that result in violations of system limits or operational best practices, 3) contextual status signals shared with or among apps such that they could update their desired setpoints based on the evolving context, 4) a mediator that incentivizes apps to come to a cooperative solution, and 5) Setpoint-informed optimization as a fallback mechanism if a cooperative solution cannot be agreed upon by applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determination methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus, the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique. Therefore, the proposed methodology in this paper plays a crucial role in guaranteeing the safety of the nuclear power plants systematically satisfying one of two critical requirements from the safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Autonomous control for Heat-Pipe microreactor using Data-Driven model predictive control

To enable a self-regulating capability for heat pipe (HP) microreactors, an anticipatory control strategy achieved via model predictive control (MPC) could proactively respond to potential disturbances and deviations in operating setpoints. This paper demonstrates data-driven methods for predicting the distribution and transient of temperatures and heat fluxes at selected components and regions in a 37-HP system, based on which the optimal control actions in response to changes in user-defined setpoints can be found. We present the development and validation of linear state-space model, feedfoward, and recurrent neural networks. Here, we compare the performance of MPCs with different modeling approaches in terms of following setpoints for temperatures and averaged output heat fluxes. The accuracies of the three data-driven models are similar, but the control actions initiated by neural-network-based MPC can better adapt to drastic changes in setpoints yet generate the smallest errors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of pre-cooling as a recommended measure to improve residential buildings’ thermal resilience during heat waves

More intense heat waves are expected to occur more frequently in the twenty-first century. During severe heat waves, cooling capacity shortfall and overheating are likely to occur in residential buildings, and this will adversely affect occupant's thermal comfort and productivity. We propose a strategy of pre-cooling the house during off-peak hours to mitigate overheating during heat waves. Additionally, simulation results of a prototype single-family house show that adopting the rule-based control (RBC) of pre-cooling thermostat setpoint schedule is effective in reducing thermal discomfort, and that the efficacy of pre-cooling depends upon several building characteristics. An optimized control (OC) of the thermostat setpoint schedule was developed based on the simulation of a prototype building. A simplified yet improved RBC (IRBC) pre-cooling schedule was then extracted from the OC schedule for practical implementation at a larger scale. The effects of the RBC schedule and IRBC schedule were evaluated in the King District of Fresno, which contains 814 residential buildings. Results show that both thermostat setpoint schedules can reduce overheating effectively and that IRBC is slightly better than RBC for most buildings. The findings support the California government's recommendation on pre-cooling to mitigate overheating, which can be further improved with an optimized thermostat setpoint schedule broadcast to residents through early alert messages before a heat wave.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transactive Control Design for Commercial Buildings to Provide Demand Response

Transactive coordination and control is a new type of distributed strategy that is designed to engage various self-interested distributed energy resources such as controllable loads, distributed generators, and energy storage for providing demand response. In this paper, a novel transactive control design is proposed for commercial buildings to coordinate the electricity demand of the package rooftop air conditioning units (RTUs) for demand response. Such a coordination is realized by introducing a local relationship between the temperature setpoint and the market clearing price. With the proposed market-based control, the demand of individual RTUs is adjusted by changing their temperature setpoints as a response to the market clearing prices. Two dierent scenarios of demand response are considered herein. One is to limit the peak demand of commercial buildings, in which a new market clearing strategy based on proportionalintegral- derivative control with respect to the demand limit is proposed. The other one is to perform price responsive control, in which the total demand of commercial buildings will respond to the real-time pricing. The proposed transactive strategy is also tested and demonstrated on a real occupied building located at Pacic Northwest National Laboratory. The eld testing results conrm the eectiveness of the proposed transactive coordination and control for commercial building with RTUs to provide demand response.

Huang, Sen↗

Self-Security for Grid-Interactive Smart Inverters Using Steady-State Reference Model

Smart inverters exchange information with other devices through a shared communication link, making the inverters more prone to receive harmful commands from external parties. This erroneous data can be received due to an anomaly in the system, such as a device fault, unintentional utility operator action, or a cyber-attack. In this paper, a device-level self-security strategy is implemented using reference models for a grid-interactive inverter to examine the incoming power setpoints, detect the anomalies, and protect the system accordingly. The PQ setpoints received from the utility supervisory controller are autonomously examined using the inverter’s normal and stable operating regions before engaging the setpoints to the inverter’s local controller. Grid parameters are estimated in real-time during the examination process. The efficacy of the self-security algorithm is tested using a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative grid emulator. The results verify that the proposed method can detect harmful PQ setpoints that can cause abnormal or unstable inverter operation.

Gursoy, Mehmetcan↗

Peak Reduction Using Mode Adjustment of Heat Pump Water Heaters in a Residential Neighborhood

Building electrification is putting pressure on distribution grid worldwide. Peak reduction is an important concern that can help reduce the growing stress and allow to defer investments in new capacity. Water heaters represent a convenient way of reducing peak because they are less dependent on weather, and their storage volume allows for asynchronous water heating and hot water use. Previous empirical studies investigated the ability of water heaters to reduce peak through the adjustment of the temperature setpoint. However, not all equipment vendors offer this option. This study aims at understanding the feasibility of peak reduction with an alternative configuration available in the market - by adjusting the device mode rather than temperature setpoint. The peak reduction methodology is tested in an occupied 46-townhome neighborhood located in Atlanta, GA. We find that peak shifting is possible with the adjustable mode approach, with the change in the peak load by 30-60%.

demand response↗