Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Self-Sealing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

31 records · Page 2

A decade of progress in understanding and managing legacy well integrity for geologic carbon storage

This study reviews a decade of research progress in legacy well integrity and risk management for geologic carbon storage (GCS) to commemorate the 20 th anniversary of the Intergovernmental Panel on Climate Change’s 2005 Special Report on Carbon Capture and Storage. In the past ten years, legacy well research has benefited from global efforts to constrain emissions from abandoned oil and gas wells, a continued focus on well materials performance in the presence of CO 2 -rich fluids, and practical experience gained through GCS implementation. Field measurements of abandoned well emissions show that leakage is not universal or catastrophic but forms a continuum of low-to-moderate fluxes that depend on isolation integrity and environmental attenuation. Materials research has constrained the conditions under which Portland cements exhibit self-sealing and non-sealing behaviors, and has identified the impact of geomechanical properties, non-uniform pathway apertures, multi-phase flow, and impurities in the CO 2 stream, on leakage pathways as important new areas for investigation. GCS projects at brownfield sites have inspired the creation of new workflows that integrate various tools and technologies to manage legacy well leakage risks. GCS implementation has also motivated a push towards scenario-based well modeling that directly informs permit applications. These advances inspire new research questions for the coming decade, particularly around the level of legacy well leakage risk that is environmentally acceptable and tolerable to stakeholders when sequestering millions of tonnes of CO 2 annually.

Carbon capture and storage

RANGERS: Methodology Report on Design and Performance Assessment of Engineered Barrier Systems in a Salt Repository for HLW/SNF

Salt formations are one of the potential host rocks for the final disposal of high-level radioactive waste (HLW) in deep geological repositories, both in Germany and the United States. The safe isolation of radioactive waste in these repositories relies on a multi-barrier system, combining engineered and natural barriers. The natural barrier is provided by the salt rock itself, known for its self-sealing properties and long-term stability. The engineered barrier, on the other hand, comprises sealing components strategically placed within the repository to enhance its containment capabilities. In both Germany and the United States, long-term safety assessments require demonstrating the integrity of the natural barrier for a period of up to 1 million years. Concurrently, the engineered barrier system (EBS) must maintain its structural and functional integrity until the long-term sealing, such as the granular salt backfill material, has re-consolidated to its final low porosity and permeability. Based on extensive expertise and experience with engineered barriers in salt formations, BGE TECHNOLOGY GmbH and Sandia National Laboratories have partnered to develop a robust methodology for the integrity and performance assessment of EBS in HLW repositories through the RANGERS project. This collaborative effort aims to establish a unified approach to geotechnical engineering, repository design, integrity and performance evaluation of EBS in salt repositories.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Two hundred passage three-way valve: Fraction collector

This paper describes the design and operation of a fraction collector used to direct flow of separated biological materials from 197 capillary tubes to either a collection tray or to a waste tank. This mechanism uses a 28-volt dc gear motor driving twin cams to force 197 needles through a self-sealing silicone rubber septum, where they inject the material in 197 separate pockets in a collection tray. The position of the collector tray is sensed by two optical limit switches. The time sequences are controlled automatically by an electronics control monitoring module.

Keffer, J. L.

Seals Related Research at NASA. Lewis Research Center

Some current efforts in seal research at the Lewis Research Center include self-sealing linear segmented ceramic configurations, the T700 brush seal engine test, flow and duration characteristics of brush seals and other configurations, cryogenic hydrogen brush seal tests, and a brush seal tester. Information is given in diagram and graphs for a labyrinth seal and a straight cylindrical seal.

Hendricks, Robert C.

Space Suit Survivability Enhancement NASA Research Announcement 96-OLMSA-01B: Advanced Life Support and Environmental Technologies for Human Exploration and Development of Space

Conducted two meetings to review the project scope and develop concepts for self-sealing material compositions, Focus has been on developing concepts that would seal a penetration enough to allow the astronauts to re-enter the spacecraft within the window provided by the emergency air supply. Concepts discussed include: quilted fabrics containing a viscous flow material in the quilted cells which would seal the bladder breach when forced to flow by the internal suit pressure; a sealant impregnated felt liner which acts similar to above; and a "blousy" fibrous layer which would mechanically plug a rupture under pressure. Illustrations of the above concepts are included in the attached viewgraphs, which were used in a presentation. The most promising of these concepts will be made into prototypes for testing. ILC has developed a test fixture to test the scaling characteristics of various material layups by measuring real-time changes in pressure and make-up flow in a pressurized cylinder. Candidate viscous sealing compounds such as silicones and urethanes have been identified. These compounds will be coated on existing bladder cloth for initial tests. The most promising compounds will be integrated into the above material structures for final testing. Design and analysis of fabric weaves to improve cut and puncture resistance of the suit TMG layers is underway. Philadelphia Textile is developing a mathematical model to correlate yarn type and weave structure to cut and tear resistance. The computer mathematical modeling of the fabric failure mechanisms by Cornell University, as originally proposed, will be replaced with the above model and empirical testing methods, due to the loss of key Cornell personnel.

Source record

NASA Research Announcement for Space Suit Survivability Enhancement

This report documents the research activities for space suit survivability material enhancements. Self-sealing mechanisms for the pressure envelope were addressed, as were improvements in materials for cut, puncture, and hypervelocity impact resistance.

Fredrickson, Thad H.

Developing Flexible, High Performance Polymers with Self-Healing Capabilities

Flexible, high performance polymers such as polyimides are often employed in aerospace applications. They typically find uses in areas where improved physical characteristics such as fire resistance, long term thermal stability, and solvent resistance are required. It is anticipated that such polymers could find uses in future long duration exploration missions as well. Their use would be even more advantageous if self-healing capability or mechanisms could be incorporated into these polymers. Such innovative approaches are currently being studied at the NASA Kennedy Space Center for use in high performance wiring systems or inflatable and habitation structures. Self-healing or self-sealing capability would significantly reduce maintenance requirements, and increase the safety and reliability performance of the systems into which these polymers would be incorporated. Many unique challenges need to be overcome in order to incorporate a self-healing mechanism into flexible, high performance polymers. Significant research into the incorporation of a self-healing mechanism into structural composites has been carried out over the past decade by a number of groups, notable among them being the University of I1linois [I]. Various mechanisms for the introduction of self-healing have been investigated. Examples of these are: 1) Microcapsule-based healant delivery. 2) Vascular network delivery. 3) Damage induced triggering of latent substrate properties. Successful self-healing has been demonstrated in structural epoxy systems with almost complete reestablishment of composite strength being achieved through the use of microcapsulation technology. However, the incorporation of a self-healing mechanism into a system in which the material is flexible, or a thin film, is much more challenging. In the case of using microencapsulation, healant core content must be small enough to reside in films less than 0.1 millimeters thick, and must overcome significant capillary and surface tension forces to flow, mix and react to achieve healing. Vascular networks small enough to fit into such films must also overcome these same flow limitations. Self-healing has also been demonstrated in ionomeric substrates such as Surlyn , wherein the heat generated by a projectile impact triggers the latent ability of this substrate to flow back to its original shape. Recent work using Diels-Alder reactions have shown promise in bringing about actual reforming of broken chemical bonds to achieve self-healing [2]. All self-healing mechanisms that rely on the use of inherent latent substrate properties require some degree of polymer chain flow to achieve any significant level of healing.

Jolley, Scott T.

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record

Self-Healing Technologies for Wiring and Surfaces in Aerospace and Deep Space Exploration Applications

Self-healing technologies have been identified as critical technology gaps for future exploration. NASA and KSC have been working in this area for multiple years with established intellectual property; however, there are many challenges that remain in this area of research. How do we mimic what the body does so naturally when we as NASA have unique requirements? We have been investigating several mechanisms for self-healing: microencapsulation with a healant core to fill in voids in the case of mechanical puncture and flowable (or sealable)systems that have inherent chemical properties that allow the materials to flow back together when cut or damaged. The microcapsules containing healant have to be durable and robust, must be able to take high temperatures to meet NASA unique requirements, provide good capillary flow of the healant, and be small in diameters to fill in damage voids in thin films or surfaces. Sealable systems have to flow in a range of temperatures and yet be lightweight and chemically resistant. The systems currently being developed are based on polyimide and polyurethane matrices and have been studied for use in high performance wiring systems, inflatable systems, and habitation structures. Self-healing or self-sealing capability would significantly reduce maintenance requirements and increase the safety and reliability performance of critical systems. Advances in these self-healing technologies and some of the unique challenges needed to be overcome in order to incorporate a self-healing mechanism into wiring or thin films systems will be addressed.

Self-healing technologies

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller