Improving the Pitting Corrosion Performance of Additively Manufactured 316L Steel Via Optimized Selective Laser Melting Processing Parameters
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Purpose: There are clinical decision challenges to select optimal treatment positions for left-sided breast cancer patients—supine free breathing (FB), supine Deep Inspiration Breath Hold (DIBH) and prone free breathing (prone). Physicians often make the decision based on experiences and trials, which might not always result optimal OAR doses. We herein propose a mathematical model to predict the lowest OAR doses among these three positions, providing a quantitative tool for corresponding clinical decision. Methods: Patients were scanned in FB, DIBH, and prone positions under an IRB approved protocol. Tangential beam plans were generated for each position, and OAR doses were calculated. The position with least OAR doses is defined as the optimal position. The following features were extracted from each scan to build the model: heart, ipsilateral lung, breast volume, in-field heart, ipsilateral lung volume, distance between heart and target, laterality of heart, and dose to heart and ipsilateral lung. Principal Components Analysis (PCA) was applied to remove the co-linearity of the input data and also to lower the data dimensionality. Feature selection, another method to reduce dimensionality, was applied as a comparison. Support Vector Machine (SVM) was then used for classification. Thirtyseven patient data were acquired; up to now, five patient plans were available. K-fold cross validation was used to validate the accuracy of the classifier model with small training size. Results: The classification results and K-fold cross validation demonstrated the model is capable of predicting the optimal position for patients. The accuracy of K-fold cross validations has reached 80%. Compared to PCA, feature selection allows causal features of dose to be determined. This provides more clinical insights. Conclusion: The proposed classification system appeared to be feasible. We are generating plans for the rest of the 37 patient images, and more statistically significant results are to be presented.
Multi‑gear transmission systems are commonly used in electric traction drives for medium and heavy‑duty vehicles, while most passenger‑vehicle electric drivetrains rely on a single fixed ratio to reduce cost, weight, and complexity. Using multiple gear ratios can enable downsizing of the motor and inverter while still meeting performance requirements. Additionally, appropriately chosen ratios allow the motor to operate more frequently in high‑efficiency regions, improving overall energy usage and reducing operating costs over the drive cycle. This paper presents a systematic approach for selecting optimal gear ratios for electric drive systems. A neural‑network model is first developed to represent motor losses across the full torque–speed range using data generated from finite element analysis. This model enables fast, accurate evaluation of motor efficiency under varying operating conditions. A genetic‑algorithm‑based optimization framework is then applied to identify gear ratios that maximize energy cost savings over the drive cycle, with the resulting optimal ratios stored for real‑time implementation.
This paper presents the results of two case studies regarding the wind farm layout optimization problem. We asked a general audience to take part in the studies that we designed, and nine individuals participated. Case study 1 considered variations in optimization strategies for a given simple Gaussian wake model. Participants were provided with a wake model that outputs annual energy production (AEP) for an input set of wind turbine locations. Participants used an optimization method of their choosing to find an optimal wind farm layout. Case study 2 looked at trade-offs in performance resulting from variation in both physics model and optimization strategy. For case study 2, participants calculated AEP using a wake model of their choice while also implementing their chosen optimization method. Participants then used their wake model to calculate the AEP all other participant submitted turbine configurations produce for cross-comparison results. for optimized turbine locations were then cross-compared by recalculating the AEP using every other participant's wake model. Results for case study 1 show that the best optimal wind farm layouts in this study were achieved by participants who used gradient-based optimization methods. A front-runner emerged with the Sparse Nonlinear OPTimizer plus Wake Expansion Continuation (SNOPTplusWEC) optimization method, which consistently discovered a higher AEP for each scenario. Results for case study 2 show that for small wind farms with few turbines, turbine placement on the wind farm boundary is superior. Conclusions for case study 2 were drawn from participant cross-comparison of results.
This paper presents the results of two case studies regarding the wind farm layout optimization problem. We asked a general audience to take part in the studies that we designed, and nine individuals participated. Case study 1 considered variations in optimization strategies for a given simple Gaussian wake model. Participants were provided with a wake model that outputs annual energy production (AEP) for an input set of wind turbine locations. Participants used an optimization method of their choosing to find an optimal wind farm layout. Case study 2 looked at trade-offs in performance resulting from variation in both physics model and optimization strategy. For case study 2, participants calculated AEP using a wake model of their choice while also implementing their chosen optimization method. Participants then used their wake model to calculate the AEP all other participant submitted turbine configurations produce for cross-comparison results. for optimized turbine locations were then cross-compared by recalculating the AEP using every other participant's wake model. Results for case study 1 show that the best optimal wind farm layouts in this study were achieved by participants who used gradient-based optimization methods. A front-runner emerged with the Sparse Nonlinear OPTimizer plus Wake Expansion Continuation (SNOPTplusWEC) optimization method, which consistently discovered a higher AEP for each scenario. Results for case study 2 show that for small wind farms with few turbines, turbine placement on the wind farm boundary is superior. Conclusions for case study 2 were drawn from participant cross-comparison of results.
BOOTS is a package for optimal selection of candidate operating points in large-scale manufacturing applications. It is designed to optimally select operating points to maximize predicted values of product quality and resource efficiency according to a data-driven model. The package is based on the use of a multi-input multi-output (MIMO) Gaussian process model to describe the relationships between inputs (operating points) and outputs (product quality and resource efficiency). This package does not provide any site- or process-specific information.
Tailoring the emission spectra of a thermophotovoltaic (TPV) emitter away from that of a blackbody has the potential to minimize transmission and thermalization loss in a photovoltaic receiver. Selective TPV emitters can lead to solar energy conversion with efficiency greater than the Shockley-Queisser limit and can facilitate the generation of useful energy from waste heat. A new design is introduced to radically tune thermal emission that leverages the interplay between two resonant phenomena in simple planar nanostructures-absorption in weakly absorbing nanofilms and reflection in multilayer dielectric stacks. A virtual screening approach is employed to identify promising structures for a selective thermal emitter from a search space of millions, several of which approach the ideal values of a step-function selective thermal emitter. One of these structures is experimentally fabricated and evaluated, which includes a weakly absorbing alloy with tailored optical properties fabricated by atomic layer deposition (ALD). The versatility of the design and fabrication approach result in an emitter with excellent spectral density (0.8 W cm(-2) sr(-1)) and spectral efficiency (46.8%) at 1373 K. Future experimental challenges to a more accurate realization of the optimal structures calculated are also considered.
Full configuration interaction (FCI) solvers are limited to small basis sets due to their expensive computational costs. An optimal orbital selection for FCI (OptOrbFCI) is proposed to boost the power of existing FCI solvers to pursue the basis set limit under a computational budget. The optimization problem coincides with that of the complete active space SCF method (CASSCF), while OptOrbFCI is algorithmically quite different. OptOrbFCI effectively finds an optimal rotation matrix via solving a constrained optimization problem directly to compress the orbitals of large basis sets to one with a manageable size, conducts FCI calculations only on rotated orbital sets, and produces a variational ground-state energy and its wave function. Coupled with coordinate descent full configuration interaction (CDFCI), we demonstrate the efficiency and accuracy of the method on the carbon dimer and nitrogen dimer under basis sets up to cc-pV5Z. We also benchmark the binding curve of the nitrogen dimer under the cc-pVQZ basis set with 28 selected orbitals, which provide consistently lower ground-state energies than the FCI results under the cc-pVDZ basis set. Furthermore, the dissociation energy in this case is found to be of higher accuracy.
Multispectral imaging can offer many benefits in cost, complexity, resolution, size, weight, and power, relative to hyperspectral imaging. When designing a multispectral system, spectral bandpasses can be selected using optimization algorithms configured to maximally separate target detection scores between target and background regions. A hyperspectral image (HSI) can serve as the source of data from which band groupings can be tested for optimality. The output of an adaptive cosine estimator target detection algorithm is used in an objective function. Three optimization algorithms are compared: particle swarm, dual annealing, and differential evolution. A global optimum is also found using a brute force approach on the Livermore Computing Syrah supercomputer. Three materials are investigated: calcite, gypsum, and limestone. This is done for 3-, 4-, and 5-band systems. The data originate from a longwave infrared HSI of a material display board. The optimization algorithms were run 30 times for every scenario. Performance statistics (maximum, minimum, mean, standard deviation, and median) based on the separation values are given. Additional characterization was performed using receiver operator characteristic (ROC) curves and the area under the ROC curve. While good performance was obtained for the three optimization algorithms, the dual annealing algorithm produced the highest and most consistent detection separation scores on average.
Purpose: To develop an evidential reasoning approach for selecting the optimal solution from a Pareto solution set obtained by a multi-objective radiomics model for predicting distant failure in lung SBRT. Methods: In the multi-objective radiomics model, both sensitivity and specificity are considered as the objective functions simultaneously. A Pareto solution set with many feasible solutions will be resulted from the multi-objective optimization. In this work, an optimal solution Selection methodology for Multi-Objective radiomics Learning model using the Evidential Reasoning approach (SMOLER) was proposed to select the optimal solution from the Pareto solution set. The proposed SMOLER method used the evidential reasoning approach to calculate the utility of each solution based on pre-set optimal solution selection rules. The solution with the highest utility was chosen as the optimal solution. In SMOLER, an optimal learning model coupled with clonal selection algorithm was used to optimize model parameters. In this study, PET, CT image features and clinical parameters were utilized for predicting distant failure in lung SBRT. Results: Total 126 solution sets were generated by adjusting predictive model parameters. Each Pareto set contains 100 feasible solutions. The solution selected by SMOLER within each Pareto set was compared to the manually selected optimal solution. Five-cross-validation was used to evaluate the optimal solution selection accuracy of SMOLER. The selection accuracies for five folds were 80.00%, 69.23%, 84.00%, 84.00%, 80.00%, respectively. Conclusion: An optimal solution selection methodology for multi-objective radiomics learning model using the evidential reasoning approach (SMOLER) was proposed. Experimental results show that the optimal solution can be found in approximately 80% cases.
The adoption of distributed energy resources such as photovoltaics (PVs) has increased dramatically during the previous decade. The increased penetration of PVs into distribution networks (DNs) can cause voltage fluctuations that have to be mitigated. One of the key utility assets employed to this end are step-voltage regulators (SVRs). It is desirable to include tap selection of SVRs in optimal power flow (OPF) routines, a task that turns out to be challenging because the resultant OPF problem is nonconvex with added complexities stemming from accurate SVR modeling. While several convex relaxations based on semi-definite programming (SDP) have been presented in the literature for optimal tap selection, SDP based schemes do not scale well and are challenging to implement in large-scale planning or operational frameworks. This paper deals with the optimal tap selection (OPTS) problem for wye-connected SVRs using linear approximations of power flow equations. Specifically, the LinDist3Flow model is adopted and the effective SVR ratio is assumed to be continuous- enabling the formulation of a problem called LinDist3Flow-OPTS, which amounts to a linear program. The scalability and optimality gap of LinDist3Flow-OPTS are evaluated with respect to existing SDP-based and nonlinear programming techniques for optimal tap selection in three standard feeders, namely, the IEEE 13-bus, 123-bus, and 8500-node DNs. For all DNs considered, LinDist3Flow-OPTS achieves an optimality gap of approximately 1% or less while significantly lowering the computational burden.
The adoption of distributed energy resources such as photovoltaics (PVs) has increased dramatically during the previous decade. The increased penetration of PVs into distribution networks (DNs) can cause voltage fluctuations that have to be mitigated. One of the key utility assets employed to this end are step-voltage regulators (SVRs). It is desirable to include tap selection of SVRs in optimal power flow (OPF) routines, a task that turns out to be challenging because the resultant OPF problem is nonconvex with added complexities stemming from accurate SVR modeling. While several convex relaxations based on semi-definite programming (SDP) have been presented in the literature for optimal tap selection, SDP based schemes do not scale well and are challenging to implement in large-scale planning or operational frameworks. This paper deals with the optimal tap selection (OPTS) problem for wye-connected SVRs using linear approximations of power flow equations. Specifically, the LinDist3Flow model is adopted and the effective SVR ratio is assumed to be continuous–enabling the formulation of a problem called LinDist3Flow-OPTS, which amounts to a linear program. The scalability and optimality gap of LinDist3Flow-OPTS are evaluated with respect to existing SDP-based and nonlinear programming techniques for optimal tap selection in three standard feeders, namely, the IEEE 13-bus, 123-bus, and 8500-node DNs. For all DNs considered, LinDist3Flow-OPTS achieves an optimality gap of approximately 1% or less while significantly lowering the computational burden.
The separation and optimization of noise components is critical to microwave-kinetic inductance detector (MKID) development. We analyze the effect of several changes to the lumped-element inductor and interdigitated capacitor geometry on the noise performance of a series of MKIDs intended for millimeter-wavelength experiments. We extract the contributions from two-level system noise in the dielectric layer, the generation-recombination noise intrinsic to the superconducting thin-film, and system white noise from each detector noise power spectrum and characterize how these noise components depend on detector geometry, material, and measurement conditions such as driving power and temperature. We observe a reduction in the amplitude of two-level system noise with both an elevated sample temperature and an increased gap between the fingers within the interdigitated capacitors for both aluminum and niobium detectors. We also verify the expected reduction of the generation-recombination noise and associated quasiparticle lifetime with reduced inductor volume. This study also iterates over different materials, including aluminum, niobium, and aluminum manganese, and compares the results with an underlying physical model.
Purpose: To develop a new robust optimization strategy for intensity-modulated proton therapy as an important step in translating robust proton treatment planning from research to clinical applications. Methods: In selective robust optimization, a worst-case-based robust optimization algorithm is extended, and terms of the objective function are selectively computed from either the worst-case dose or the nominal dose. Two lung cancer cases and one head and neck cancer case were used to demonstrate the practical significance of the proposed robust planning strategy. The lung cancer cases had minimal tumor motion less than 5 mm, and, for the demonstration of the methodology, are assumed to be static. Results: Selective robust optimization achieved robust clinical target volume (CTV) coverage and at the same time increased nominal planning target volume coverage to 95.8%, compared to the 84.6% coverage achieved with CTV-based robust optimization in one of the lung cases. In the other lung case, the maximum dose in selective robust optimization was lowered from a dose of 131.3% in the CTV-based robust optimization to 113.6%. Selective robust optimization provided robust CTV coverage in the head and neck case, and at the same time improved controls over isodose distribution so that clinical requirements may be readily met. Conclusions: Selective robust optimization may provide the flexibility and capability necessary for meeting various clinical requirements in addition to achieving the required plan robustness in practical proton treatment planning settings.
Demand Response (DR) events are initiated by utilities during peak demand periods to curtail consumption. They ensure system reliability and minimize the utility’s expenditure. Selection of the right customers and strategies is critical for a DR event. An effective DR scheduling algorithm minimizes the curtailment error which is the absolute difference between the achieved curtailment value and the target. State-of-the-art heuristics exist for customer selection, however their curtailment errors are unbounded and can be as high as 70%. In this work, we develop an Integer Linear Programming (ILP) formulation for optimally selecting customers and curtailment strategies that minimize the curtailment error during DR events in SmartGrids. We perform experiments on real world data obtained from the University of Southern California’s SmartGrid and show that our algorithm achieves near exact curtailment values with errors in the range of 10 -7 to 10 -5 , which are within the range of numerical errors. We compare our results against the state-of-the-art heuristic being deployed in practice in the USC SmartGrid. We show that for the same set of available customer strategy pairs our algorithm performs 103 to 107 times better in terms of the curtailment errors incurred.
Selection of primary controlled variables (CVs) with due consideration of economic loss and ease of control is an important step for achieving optimal plant operation under design and off-design conditions. However, the computational expense of the combinatorial optimization step that is undertaken for CV selection renders the existing approaches unaffordable for fast selection of optimal CVs. Two approaches are proposed in this paper for improving the computational efficiency of the optimization step. Typically, the CV selection process is typically executed by considering the entire plant together. Opposed to that, the first approach proposed here seeks to decompose the process plant into multiple partitions based on the connectivity strength. Then the CV selection algorithm can be executed on each partition independently. The decomposition algorithm is biomimetic and has been developed, in analogy to neuroscience, mimicking how the information about the connectivity information is extracted using a dynamic casual model. This approach can significantly decrease the number of combinatorial optimization problems that needs to be solved and facilitates parallelization of the solution. In the second approach, a multiagent optimization framework is proposed that utilizes metaheuristic optimization strategies such as the efficient ant colony algorithm, simulated annealing and the genetic algorithm. These two approaches can be used by themselves or in combination. This framework enables cooperative search by a group of algorithmic agents facilitated through an information sharing protocol. These two approaches are applied to a toy problem and an acid gas removal unit as part of an integrated gasification combined cycle. This study shows how the computational time and economic and control performance of the optimal CV sets vary as the number of partitions are changed.
Automatic generation control (AGC) is used to maintain acceptable frequencies during operation owing to fluctuations in load and variable resources. In conventional industry applications, the AGC signal is allocated to each generator according to the predispatched frequency regulation capacity or the order of economic efficiency. However, with the increasing integration of inverter-based resources (IBRs), the retirement of conventional synchronous generators (SGs) has posed new challenges to frequency control schemes because fewer of them are optional for AGC regulation. In this paper, we propose a novel model predictive control (MPC)-based frequency regulation model to reduce control cost and ensure stability, by considering different critical dynamic factors when optimally selecting the AGC units. The proposed control model – developed in a general form – comprehensively embeds characteristics such as generator ramping rates, reserve capacity, and operation cost. The model predictive control–based two-timescale AGC scheme enhances the capability of immunizing the power disturbance from types of resources by coordinating the control signals between faster IBRs and slower SGs. The case study’s proposed model is verified to be effective in synergistically enforcing different dynamic properties of AGC units into the frequency regulation scheme.