Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample size determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Intrinsic Lyα Profiles of High-velocity G, K, and M Dwarfs

Observations of HILymanα, the brightest UV emission line of late-type stars, are critical for understanding stellar chromospheres and transition regions, modeling photochemistry in exoplanet atmospheres, and measuring the abundances of neutral hydrogen and deuterium in the interstellar medium. Yet Lyαobservations are notoriously challenging owing to severe attenuation from interstellar gas, hindering our understanding of this important emission line’s basic morphology. We present high-resolution far- and near-UV spectroscopy of five G, K, and M dwarfs with radial velocities large enough to Doppler-shift the stellar Lyαemission line away from much of the interstellar attenuation, allowing the line core to be directly observed. We detect self-reversal in the Lyαemission-line core for all targets, and we show that the self-reversal depth decreases with increasing surface gravity. Mg II self-reversed emission-line profiles provide some useful information to constrain the Lyαline core, but the differences are significant enough that Mg II cannot be used directly as an intrinsic Lyαtemplate during reconstructions. We show that reconstructions that neglect self-reversal could overestimate intrinsic Lyαfluxes by as much as 60%–100% for G and K dwarfs and 40%–170% for M dwarfs. The five stars of our sample have low magnetic activity and subsolar metallicity; a larger sample size is needed to determine how sensitive these results are to these factors.

Allison Youngblood↗

A Monte Carlo investigation of experimental data requirements for fitting polynomial functions

This report examines the extent to which sample size affects the accuracy of a low order polynomial approximation of an experimentally observed quantity and establishes a trend toward improvement in the accuracy of the approximation as a function of sample size. The task is made possible through a simulated analysis carried out by the Monte Carlo method, in which data are generated by using several transcendental or algebraic functions as models. Contaminated data of varying amounts are fitted to linear quadratic or cubic polynomials, and the behavior of the mean-squared error of the residual variance is determined as a function of sample size. Results indicate that the effect of the size of the sample is significant only for relatively small sample sizes and diminishes drastically for moderate and large amounts of experimental data.

Canavos, G. C.↗

An empirical analysis of the quantitative effect of data when fitting quadratic and cubic polynomials

A study is made of the extent to which the size of the sample affects the accuracy of a quadratic or a cubic polynomial approximation of an experimentally observed quantity, and the trend with regard to improvement in the accuracy of the approximation as a function of sample size is established. The task is made possible through a simulated analysis carried out by the Monte Carlo method in which data are simulated by using several transcendental or algebraic functions as models. Contaminated data of varying amounts are fitted to either quadratic or cubic polynomials, and the behavior of the mean-squared error of the residual variance is determined as a function of sample size. Results indicate that the effect of the size of the sample is significant only for relatively small sizes and diminishes drastically for moderate and large amounts of experimental data.

Canavos, G. C.↗

Probing the Magnetic Causes of CMEs: Free Magnetic Energy More Important Than Either Size Or Twist

To probe the magnetic causes of CMEs, we have examined three types of magnetic measures: size, twist and total nonpotentiality (or total free magnetic energy) of an active region. Total nonpotentiality is roughly the product of size times twist. For predominately bipolar active regions, we have found that total nonpotentiality measures have the strongest correlation with future CME productivity (approx. 75% prediction success rate), while size and twist measures each have a weaker correlation with future CME productivity (approx. 65% prediction success rate) (Falconer, Moore, & Gary, ApJ, 644, 2006). For multipolar active regions, we find that the CME-prediction success rates for total nonpotentiality and size are about the same as for bipolar active regions. We also find that the size measure correlation with CME productivity is nearly all due to the contribution of size to total nonpotentiality. We have a total nonpotentiality measure that can be obtained from a line-of-sight magnetogram of the active region and that is as strongly correlated with CME productivity as are any of our total-nonpotentiality measures from deprojected vector magnetograms. We plan to further expand our sample by using MDI magnetograms of each active region in our sample to determine its total nonpotentiality and size on each day that the active region was within 30 deg. of disk center. The resulting increase in sample size will improve our statistics and allow us to investigate whether the nonpotentiality threshold for CME production is nearly the same or significantly different for multipolar regions than for bipolar regions. In addition, we will investigate the time rates of change of size and total nonpotentiality as additional causes of CME productivity.

Falconer, D. A.↗

Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

Juarez, Alfredo↗

Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

Juarez, Alfredo↗

Mechanical Impact Testing: A Statistical Measurement

In the decades since the 1950s, when NASA first developed mechanical impact testing of materials, researchers have continued efforts to gain a better understanding of the chemical, mechanical, and thermodynamic nature of the phenomenon. The impact mechanism is a real combustion ignition mechanism that needs understanding in the design of an oxygen system. The use of test data from this test method has been questioned due to lack of a clear method of application of the data and variability found between tests, material batches, and facilities. This effort explores a large database that has accumulated over a number of years and explores its overall nature. Moreover, testing was performed to determine the statistical nature of the test procedure to help establish sample size guidelines for material characterization. The current method of determining a pass/fail criterion based on either light emission or sound report or material charring is questioned.

Engel, Carl D.↗

Measuring Shock Stage of ltokawa Regolith Grains by Electron Back-Scattered Diffraction and Synchrotron X-Ray Diffraction

We have been analyzing Itokawa samples in order to definitively establish the degree of shock experienced by the regolith of asteroid Itokawa, and to devise a bridge between shock determinations by standard light optical petrography, crystal structures as determined by electron and X-ray diffraction techniques. We are making measurements of olivine crystal structures and using these to elucidate critical regolith impact processes. We use electron back-scattered diffraction (EBSD) and synchrotron X-ray diffraction (SXRD). We are comparing the Itokawa samples to L and LL chondrite meteorites chosen to span the shock scale experienced by Itokawa, specifically Chainpur (LL3.4, Shock Stage 1), Semarkona (LL3.00, S2), Kilabo (LL6, S3), NWA100 (L6, S4) and Chelyabinsk (LL5, S4). In SXRD we measure the line broadening of olivine reflections as a measure of shock stage. In this presentation we concentrate on the EBSD work. We employed JSC's Supra 55 variable pressure FEG-SEM and Bruker EBSD system. We are not seeking actual strain values, but rather indirect strain-related measurements such as extent of intra-grain lattice rotation, and determining whether shock state "standards" (meteorite samples of accepted shock state, and appropriate small grain size) show strain measurements that may be statistically differentiated, using a sampling of particles (number and size range) typical of asteroid regoliths. Using our system we determined that a column pressure of 9 Pa and no C-coating on the sample was optimal. We varied camera exposure time and gain to optimize mapping performance, concluding that 320x240 pattern pixilation, frame averaging of 3, 15 kV, and low extractor voltage yielded an acceptable balance of hit rate (>90%), speed (11 fps) and map quality using an exposure time of 30 ms (gain 650). We found that there was no strong effect of step size on Grain Orientation Spread (GOS) and Grain Reference Orientation Deviation angle (GROD-a) distribution; there was some effect on grain average Kernel Average Misorientation (KAM) (reduced with smaller step size for the same grain), as expected. We monitored GOS, Maximum Orientation Spread (MOS) and GROD-a differences between whole olivine grains and sub-sampled areas, and found that there were significant differences between the whole grain dataset and subsets, as well as between subsets, likely due to sampling-related "noise". Also, in general (and logically) whole grains exhibit greater degrees of cumulative lattice rotation. Sampling size affects the apparent strain character of the grain, at least as measured by GOS, MOS and GROD-a. There were differences in the distribution frequencies of GOS and MOS between shock stages, and in plots of MOS and GOS vs. grain diameter. These results are generally consistent with those reported this year. However, it is unknown whether the differences between samples of different shock states exceeds the clustering of these values to the extent that shock stage determinations can still be made with confidence. We are investigating this by examination of meteorites with higher shock stage 4 to 5. Our research will improve our understanding of how small, primitive solar system bodies formed and evolved, and improve understanding of the processes that determine the history and future of habitability of environments on other solar system bodies. The results will directly enrich the ongoing asteroid and comet exploration missions by NASA and JAXA, and broaden our understanding of the origin and evolution of small bodies in the early solar system, and elucidate the nature of asteroid and comet regolith.

Zolensky, Michael↗

Calibrating the Ordovician Radiation of marine life: implications for Phanerozoic diversity trends

It has long been suspected that trends in global marine biodiversity calibrated for the Phanerozoic may be affected by sampling problems. However, this possibility has not been evaluated definitively, and raw diversity trends are generally accepted at face value in macroevolutionary investigations. Here, we analyze a global-scale sample of fossil occurrences that allows us to determine directly the effects of sample size on the calibration of what is generally thought to be among the most significant global biodiversity increases in the history of life: the Ordovician Radiation. Utilizing a composite database that includes trilobites, brachiopods, and three classes of molluscs, we conduct rarefaction analyses to demonstrate that the diversification trajectory for the Radiation was considerably different than suggested by raw diversity time-series. Our analyses suggest that a substantial portion of the increase recognized in raw diversity depictions for the last three Ordovician epochs (the Llandeilian, Caradocian, and Ashgillian) is a consequence of increased sample size of the preserved and catalogued fossil record. We also use biometric data for a global sample of Ordovician trilobites, along with methods of measuring morphological diversity that are not biased by sample size, to show that morphological diversification in this major clade had leveled off by the Llanvirnian. The discordance between raw diversity depictions and more robust taxonomic and morphological diversity metrics suggests that sampling effects may strongly influence our perception of biodiversity trends throughout the Phanerozoic.

Non-NASA Center↗

The Epiregolith

The physical properties of the lunar regolith were originally inferred from remotely sensed data, first from the Earth and later from orbiting spacecraft. The Surveyor landings and the Apollo surface explorations produced a more concrete characterization of the macroscopic properties. In general, the upper regolith consists of a loosely consolidated layer centimeters thick underlain by a particulate but extremely compacted layer to depths of meters or tens of meters. The median particle size as determined by mechanical sieving in terrestrial laboratories is several tens of micrometers. However, the comminuting processes that form the layer produce particles in all sizes down to manometers. The smallest particles, having a high surface to volume ratio, tend to be electrostatically bound to larger particles and are quite difficult to separate mechanically in the laboratory. Particle size distributions determined from lunar soil samples often group particles smaller than 10 micrometers.

Mendell, Wendell W.↗

Determining True Sensor Spatial Resolution of Very High Resolution Optical Imagery

Some satellite data is delivered in images with gridded pixels. This gridded pixel size is often assumed to be the spatial resolution of the satellite sensor; however, this is not always the case. An image can be grided to any arbitrary pixel size, but the sensor resolution will remain constant. For example, an image with a pixel grid size much smaller than the sensor resolution will appear blurry along what should be sharp transitions. This discrepancy between an image’s pixel size and true sensor spatial resolution can be the source of much confusion and even misinformation among data users, which may lead them to waste time and resources on using images that do not suit their spatial resolution needs. This presentation will highlight our evaluation of the true spatial resolution of various government and commercial images in the pixel size range of 0.3 m to 60 m. Images evaluated include ESA’s Sentinel-2 (60 m, 20 m, 10 m pixels), USGS’s Landsat 8/9 (30 m & 15 m pixels), Planet’s SuperDoves (3 m pixels), BlackSky’s Globals (~1 m pixels), and the optical bands of Maxar’s WorldView-2 (2.4 m – 0.41 m pixels) and WorldView-3 (1.38 m – 0.31 m pixels). Our evaluation of true sensor spatial resolution, or ‘footprint size’ is based on the sensor’s line spread function (LSF). We calculate the width at half the height of the LSF to find the full width at half maximum (FWHM). The FWHM is how we report sensor spatial resolution. Different objects are examined for constructing the LSF depending on the sensor spatial resolution. Coarser resolution sensors in this evaluation such as Sentinel-2 and Landsat 8/9 are examined at bridges over a dark water background. The bright bridge acts as a line impulse, giving a sensor’s line spread function (LSF) in one direction. Additionally, we simulate the impacts of bridge width on the apparent LSF to obtain a true LSF without the effects of bridge width for these sensors. Finer resolution sensors will image the irregularities in bridges such as trusses, sidewalks, and in some cases painted lines, interfering with the LSF construction. Instead, these sensors are evaluated at large (60 m – 140 m) black and white checkerboards known as Cal/Val sites. At these locations, the image’s transition from black to white is extracted as an edge spread function (ESF). We calculate the derivative of this ESF to obtain the sensor’s LSF. From there, we find the FWHM as we do for the coarser resolution images. With the FWHM and pixel size, we determine how over- or under-sampled the images are. When the ratio of a sensor’s spatial resolution and the gridded image’s pixel size is less than 1, the image is considered under-sampled. In this case, each pixel’s information is unique but only a portion of that pixel’s ground area has been measured. On the other side, if the ratio is greater than 1, the image is considered over-sampled. That is, each pixel’s information is sourced from within the ground extent of the pixel and some extent outside additionally. We will show the true spatial resolution and the extent of over-/under-sampling in the imagery from ESA’s Sentinel-2 (60 m, 20 m, 10 m pixels), USGS’s Landsat 8/9 (30 m & 15 m pixels), Planet’s SuperDoves (3 m pixels), BlackSky’s Globals (~1 m pixels), and the optical bands of Maxar’s WorldView-2 (2.4 m – 0.41 m pixels) and WorldView-3 (1.38 m – 0.31 m pixels).

Alana Semple↗

Soil Analysis Micro-Mission Concepts Derived from the MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatic environment, and arrays of material patches to study abrasion and adhesion. Heritage will be all-important for low cost micro-missions, and adaptations of instruments developed for the Pathfinder, '98 and '01 Landers should be strong contenders for '03 flights. This talk has three objectives: (1) Familiarize the audience with MECA instrument capabilities; (2) present concepts for stand-alone and/or mobile versions of MECA instruments; and (3) broaden the context of the MECA instruments from human exploration to a comprehensive scientific survey of Mars. Due to time limitations, emphasis will be on the chemistry and microscopy experiments. Ion-selective electrodes and related sensors in MECA's wet-chemistry laboratory will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential, and experiments will include cyclic voltammetry and anodic stripping. For experiments beyond 2001, enhancements could allow multiple use of the cells (for mobile experiments) and reagent addition (for quantitative mineralogical and exobiological analysis). MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Future implementations might enhance the optical microscopy with spectroscopy, or incorporate advanced AFM techniques for thermogravimetric and chemical analysis.

Hecht, M. H.↗

Computing Risk of Pyrotechnic Devices Using Lot Acceptance Testing

This paper presents an application of statistical engineering to solve the problem of determining the effects of reducing test sample sizes and environment levels in lot acceptance testing (LAT) of ordnance devices used by NASA and DoD space systems. Unlike environmental testing of dedicated qualification hardware, ordnance devices have a test-like-you-fly exception and use lot acceptance sampling or LAT. LAT is performed by randomly selecting a predefined number of devices from an individual lot and exposing them to a more severe dynamic shock and vibration testing environments than flight (sometimes as high as 6 decibels over flight environments) and then performing a destructive test on the device. Recent trends have been suggested to reduce LAT costs by reducing environment test levels or the number of devices per LAT, or both. A method is given here to compute flight risk, so the proposed methods can be compared by subject matter experts to the baseline LAT methods. In addition, this method can be used to determine the best methods to include in future LAT standards for pyrotechnic devices.

Computing Risk↗

Dry heat effects on survival of indigenous soil particle microflora and particle viability studies of Kennedy Space Center soil

Research efforts were concentrated on attempts to obtain data concerning the dry heat resistance of particle microflora in Kennedy Space Center soil samples. The in situ dry heat resistance profiles at selected temperatures for the aggregate microflora on soil particles of certain size ranges were determined. Viability profiles of older soil samples were compared with more recently stored soil samples. The effect of increased particle numbers on viability profiles after dry heat treatment was investigated. These soil particle viability data for various temperatures and times provide information on the soil microflora response to heat treatment and are useful in making selections for spacecraft sterilization cycles.

Ruschmeyer, O. R.↗

Determination of hydrogen in milligram quantities of titanium and its alloys

An accurate, versatile, and sensitive method for the determination of hydrogen in milligram-size titanium samples is presented. It involves extraction of hydrogen at 1070 K while a mercury diffusion pump transfers the evolved gases into the inlet of a mass spectrometer. All the evolved gases may then be positively identified and determined. This method can be readily adapted for use with other metals and for the study of the slow evolution of hydrogen. Reduction of interferences due to the evolution of hydrogen by reactions involving vapors such as those of water, acetone, and vacuum grease is discussed.

Otterson, D. A.↗

Computational requirements for a discrete Kalman filter.

Computational requirements - i.e., computing time per cycle (iteration) and required storage - which determine minimum sampling rates and computer memory size, were obtained as functions of the dimensions of the important system matrices for a discrete Kalman filter. Two types of measurement processing are discussed: simultaneous and sequential. It is shown that it is often better to process statistically independent measurements in more than one batch and then use sequential processing than to process them together via simultaneous processing.

Mendel, J. M.↗

Laser Diffraction Techniques Replace Sieving for Lunar Soil Particle Size Distribution Data

Sieving was used extensively until 1999 to determine the particle size distribution of lunar samples. This method is time-consuming, and requires more than a gram of material in order to obtain a result in which one may have confidence. This is demonstrated by the difference in geometric mean and median for samples measured by [1], in which a 14-gram sample produced a geometric mean of approx.52 micrometers, whereas two other samples of ~1.5 grams resulted in gave means of approx.63 and approx.69 micrometers. Sample allocations for sieving are typically much smaller than a gram, and many of the sample allocations received by our lab are 0.5 to 0.25 grams in mass. Basu [2] has described how the finest fraction of the soil is easily lost in the sieving process, and this effect is compounded when sample sizes are small.

Cooper, Bonnie L.↗

An Analysis of the Lightning Jump Algorithm Using Geostationary Lightning Mapper Flashes

This project aims to implement the two-sigma lightning jump algorithm (LJA) developed using Lightning Mapping Arrays (LMAs), with GOES-16 Geostationary Lightning Mapper (GLM) flashes, evaluate its performance, and identify any needed adjustments to the algorithm to optimize operational skill. The GLM is projected to have lower detection efficiency (DE) (70-90 percent) than operational LMAs (95-99 percent). The reduced GLM DE coupled with the coarser spatial resolution of the GLM could have impacts on flash rates and trends that could affect the LJA in various ways. Deep dives are conducted on four separate cases. Three of four cases show LMAs seeing two to three times as many flashes as the GLM. Only fifteen of twenty five GLM jumps saw increases in radar intensity while fourteen of nineteen LMA jumps did. These results suggest a larger sample sized study must be conducted to determine how to implement the LJA with the GLM.

Curtis, Nathan↗