Effects of sample preparation on photomicrographs of cadmium sulfide thin-film solar cells
Effects of preparation techniques on thin film CdS solar cells
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Effects of preparation techniques on thin film CdS solar cells
Changes in international relations, especially within the past several years, have dramatically affected the programmatic thrusts of the U.S. Department of Energy (DOE). The DOE now is addressing the environmental cleanup required as a result of 50 years of nuclear arms research and production. One major obstacle in the remediation of these areas is the chemical determination of potentially contaminated material using currently acceptable practices. Process bottlenecks and exposure to hazardous conditions pose problems for the DOE. One proposed solution is the application of modular automated chemistry using Standard Laboratory Modules (SLM) to perform Standard Analysis Methods (SAM). The Contaminant Analysis Automation (CAA) Program has developed standards and prototype equipment that will accelerate the development of modular chemistry technology and is transferring this technology to private industry.
Explore the source record for details and available documents.
An analyte selection device can include: a body defining a fluid channel having a channel inlet and channel outlet; a bipolar electrode (BPE) between the inlet and outlet; one of an anode or cathode electrically coupled with the BPE on a channel inlet side of the BPE and the other of the anode or cathode electrically coupled with the BPE on a channel outlet side of the BPE; and an electronic system operably coupled with the anode and cathode so as to polarize the BPE. The fluid channel can have any shape or dimension. The channel inlet and channel outlet can be longitudinal or lateral with respect to the longitudinal axis of the channel. The BPE can be any metallic member, such as a flat plate on a wall or mesh as a barrier BPE. The anode and cathode can be located at a position that polarizes the BPE.
Explore the source record for details and available documents.
Poster for the intern poster session on August 7th
Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.
Atmosphere- and/or moisture-sensitive materials can be challenging to characterize using electron microscopy techniques due to sample preparation workflows that generally require exposure to ambient conditions. Here, we describe a novel preparation method that uses aluminum foil in combination with a commercial cryo-EM transfer system to circumvent undesired exposure to the atmosphere. First, hygroscopic MgCl 2 was used as a model material, and prepared samples (both protected and unprotected) were placed in a controlled-humidity environment (> 80% relative humidity) for various exposure lengths (circa seconds to hours). Following this, the effectiveness of the sample preparation method was determined by comparing qualitative photos and quantitative X-ray diffraction patterns between the two sample subsets. The combined results of these experiments suggest that the outlined preparation method effectively protects MgCl 2 from atmospheric contamination compared to MgCl 2 samples that had no protective measures taken. Finally, the preparation method was utilized to protect a highly hygroscopic crystalline BaO thin film for characterization via scanning electron microscopy, thereby demonstrating a functional application of the outlined preparation technique and an additional use for the commercial cryo-EM transfer system beyond its intended application.
Monolayer submicron self supporting particle film samples preparation for sintering by transmission electron microscopy
Wiley et al. (1982) have studied sputtered amorphous films of Nb-Ni, Mo-Ni, Si-W, and Si-Mo. Kung et al. (1984) have found that amorphous Ni-Mo films as diffusion barriers between multilayer metallizations on silicon demonstrate good electrical and thermal stability. In the present investigation, the Ni-W system was selected because it is similar to the Ni-Mo system. However, W has a higher silicide formation temperature than Mo. Attention is given to aspects of sample preparation, sample characterization, the interaction between amorphous Ni-W films and Si, the crystallization of amorphous Ni(36)W(64) films on SiO2, amorphous Ni-N-W films, silicide formation and phase separation, and the crystallization of amorphous Ni(36)W(64) and Ni(30)N(21)W(49) layers.
Sample preparation is a common bottleneck in genetic analysis. Tools that reduce time and effort are of value in a laboratory setting. There is a need for a genetic analysis/detection system that is not only mobile, ruggedized, easy-to-use but also provides an enclosed fluid handling that diminishes the risks of Ribonucleic acid (RNA) contamination and degradation during processing. NASA has developed a novel assay methodology and suite of devices to isolate nucleic acids and prepare samples for real-time (quantitative) polymerase chain reaction (PCR) analysis that solves the problem of contamination and degradation because of the advanced microfluidics which provides better fluid handling. The assay employs an aqueous-based non-alcohol method that yields robust RNA quality. The suite of ready-to-use devices provide pre-loaded reagents in liquid and lyophilized formats to enable rapid, cost effective, and portable manual operation in the laboratory or remote field environments.
Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.
Explore the source record for details and available documents.
We are using innovative FIB techniques to prepare samples of planetary materials for different types of coordinated analyses using ion microprobes, synchrotron beamlines, and specialized transmission electron microscopy (TEM) techniques. In these cases, the FIB sample preparation is the critical step in enabling these specialized analyses. We discuss several examples below utilizing the FEI Quanta3D instrument at the NASA Johnson Space Center. Trace element analyses utilizing synchrotron x-ray fluorescence. The trace element content of mineral grains in comet dust provides important clues on their formation and processing in the early solar system. We preformed coordinated analyses of a comet dust particle that had been prepared using ultramicrotomy for TEM analysis. Following the TEM analyses, we extracted a 70 nm thick section from a region of the carbon (C) film of the TEM grid, for additional analyses. A carbon ring ~2-3 μm thick was deposited on top of the C film using the FIB. The C film on the outer rim of the ring was milled away using various patterns to uniformly release the stresses on the film, preventing rupture and collapse, and was attached to the micromanipulator needle. We then isolated the ring completely and transferred the section to a silicon sample holder for analysis using the HXN (hard X-ray nanoprobe) beamline at NSLSII at Brookhaven National Lab. Coordinated Analyses of Presolar Grains. Rare sub-m presolar grains that originate in evolved stars and supernovae, occur in primitive astromaterials and are identified by their exotic isotopic compositions. Coordinated analyses of these grains using NanoSIMS, TEM, and other techniques on the same grain is enabled by innovative FIB sample preparation. In order to obtain subsequent isotopic analyses of Mg and Fe, contributions from surrounding grains were minimized. We precisely deposited a protective cap of Pt on top of the grain to preserve the grain of interest and then milled away about 5 μm diameter of the surrounding material. Following the isotopic analyses, the spindle was extracted and thinned to electron transparency for TEM microstructural analyses. In situ heating TEM experiments on lunar samples. We extracted a FIB thin section from Apollo 17 lunar rock 76015. To avoid ion-beam damage, e-beam deposition was used to deposit the first 500 nm of the C strap, followed by ion beam-assisted deposition of ~3 μm carbon. We performed an ex situ lift-out of the section and placed the section on one of the elements of a microelectromechanical systems (MEMS) - specialized heating substrate and attached the section to the substrate by depositing small C straps with the FIB. The heating chips utilize silicon nitride windows to support the samples and provide uniform heating while enabling TEM imaging. The heating chip was loaded into a Hitachi “Blaze” heating holder and analyzed using a Hitachi HF5000 at the University of Arizona.
The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) project, funded by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Research Opportunities in Space and Earth Sciences (ROSES), will build upon previous miniaturized SEM designs and recent advancements in variable pressure SEM's to design and build a SEM to complete analyses of samples on the surface of Mars using the atmosphere as an imaging medium. This project is a collaboration between NASA Marshall Space Flight Center (MSFC), the Jet Propulsion Laboratory (JPL), electron gun and optics manufacturer Applied Physics Technologies, and small vacuum system manufacturer Creare. Dr. Ralph Harvery and environmental SEM (ESEM) inventor Dr. Gerry Danilatos serve as advisors to the team. Variable pressure SEMs allow for fine (nm-scale) resolution imaging and micron-scale chemical study of materials without sample preparation (e.g., carbon or gold coating). Charging of a sample is reduced or eliminated by the gas surrounding the sample. It is this property of ESEMs that make them ideal for locations where sample preparation is not yet feasible, such as the surface of Mars. In addition, the lack of sample preparation needed here will simplify the sample acquisition process and allow caching of the samples for future complementary payload use.
Here, this paper presents a novel method for preparing metallographic samples of laminated dissimilar metals, specifically a layered structure of zirconium (Zr), vanadium (V), and tungsten (W), which pose a challenge due to their differing crystal structures and hardness levels. The work was motivated by the need to develop a cladding for tungsten targets in spallation neutron sources, where a zirconium face is applied over an interlayer of either vanadium or titanium to prevent the formation of brittle intermetallic compounds such as ZrW 2 . Traditional polishing techniques prove inadequate because each constituent metal requires a different polishing approach based on its unique material properties. The methodology outlined includes a sequential process involving conductive epoxy mounting, successive grinding and polishing with specific abrasives, and a final chemical-mechanical polish using a colloidal silica-based solution. Optical microscopy confirmed that this multi-step process successfully produced scratch-free surfaces and minimized surface relief across the different metal interfaces. Although developed for refractory metals, this approach shows promise for other layered structures comprised of transition metals, offering a meticulous yet effective technique for high-quality metallographic sample preparation.
In this paper, we study the electrodeposited Ni—Pt magnetic wires, exploring the mechanisms by which changes in geometry and composition influence the local magnetic structure. The samples were prepared by electrodeposition, their elemental composition was analyzed by energy dispersive X-ray spectroscopy, and phase analysis was carried out by an X-ray diffraction measurement. Magnetic force microscopy measurements, and magnetic force microscopy measurements in magnetic field were carried out to study the domain morphology of the prepared samples. Magnetization characteristics were measured via vibrating sample magnetometry mode of a superconducting quantum interference device. Here, the results were analyzed and compared with micromagnetic simulations. It is shown that a strong perpendicular magnetic anisotropy is responsible for the characteristic checkerboard-like surface magnetization patterns, which can be tuned by geometrical constriction and Ni content. Understanding these relationships provides insights into the design of magnetic materials with tailored properties for advanced applications, like magnetic sensors.
High resolution emission and excitation fluorescent spectra were obtained for several samples in an effort to determine the optimum operational design for the instrument. The instrument was used to determine the required nature of a sample which could be detected, and in so doing, several different sample preparation techniques were considered. Numerous experiments were performed to determine the capabilities of the instrument with regard to the detection of suitably prepared virus specimens. Significant results were obtained in several areas. The fluorescent spectra indicated that substantial changes in the laser might be used advantageously to greatly improve the performance of the instrument. In the existing configuration, the instrument was shown to be capable of detecting the presence of suitably prepared virus samples.