Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYSTEM EFFICIENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Energy Savings From System Efficiency Improvements in Iowa's HVAC SAVE Program

The objective of this project is to explore the energy savings potential of maximizing furnace and distribution system performance by adjusting operating, installation, and distribution conditions. The goal of the Iowa HVAC System Adjusted and Verified Efficiency (SAVE) program is to train contractors to measure installed system efficiency as a diagnostic tool to ensure that the homeowner achieves the energy reduction target for the home rather than simply performing a tune-up on the furnace or having a replacement furnace added to a leaky system. The PARR research team first examined baseline energy usage from a sample of 48 existing homes, before any repairs or adjustments were made, to calculate an average energy savings potential and to determine which system deficiencies were prevalent. The results of the baseline study of these homes found that, on average, about 10% of the space heating energy available from the furnace was not reaching the conditioned space. In the second part of the project, the team examined a sample of 10 homes that had completed the initial evaluation for more in-depth study. For these homes, the diagnostic data shows that it is possible to deliver up to 23% more energy from the furnace to the conditioned space by doing system tune ups with or without upgrading the furnace. Replacing the furnace provides additional energy reduction. The results support the author's belief that residential heating and cooling equipment should be tested and improved as a system rather than a collection of individual components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NASA Acoustic Stirling IRAD Thermal Recovery Energy Efficient System (TREES) Energy Conversion and Management in Aircraft

NASA Acoustic Stirling IRAD (Internal Research and Development) Thermal Recovery Energy Efficient System (TREES) Energy Conversion and Management in Aircraft. Presentation on energy conversion on aircraft. Thermal energy recovery changes aircraft thermal management from being a necessary burden on aircraft performance to a desirable asset. It improves the engine performance by recycling waste heat and ultimately rejecting all collected aircraft heat out through the engine nozzle.

Dyson, Rodger↗

An efficient system for reliably transmitting image and video data over low bit rate noisy channels

This research project is intended to develop an efficient system for reliably transmitting image and video data over low bit rate noisy channels. The basic ideas behind the proposed approach are the following: employ statistical-based image modeling to facilitate pre- and post-processing and error detection, use spare redundancy that the source compression did not remove to add robustness, and implement coded modulation to improve bandwidth efficiency and noise rejection. Over the last six months, progress has been made on various aspects of the project. Through our studies of the integrated system, a list-based iterative Trellis decoder has been developed. The decoder accepts feedback from a post-processor which can detect channel errors in the reconstructed image. The error detection is based on the Huber Markov random field image model for the compressed image. The compression scheme used here is that of JPEG (Joint Photographic Experts Group). Experiments were performed and the results are quite encouraging. The principal ideas here are extendable to other compression techniques. In addition, research was also performed on unequal error protection channel coding, subband vector quantization as a means of source coding, and post processing for reducing coding artifacts. Our studies on unequal error protection (UEP) coding for image transmission focused on examining the properties of the UEP capabilities of convolutional codes. The investigation of subband vector quantization employed a wavelet transform with special emphasis on exploiting interband redundancy. The outcome of this investigation included the development of three algorithms for subband vector quantization. The reduction of transform coding artifacts was studied with the aid of a non-Gaussian Markov random field model. This results in improved image decompression. These studies are summarized and the technical papers included in the appendices.

Costello, Daniel J., Jr.↗

Systems efficiency and specific mass estimates for direct and indirect solar-pumped closed-cycle high-energy lasers in space

Based on expected advances in technology, the maximum system efficiency and minimum specific mass have been calculated for closed-cycle CO and CO2 electric-discharge lasers (EDL's) and a direct solar-pumped laser in space. The efficiency calculations take into account losses from excitation gas heating, ducting frictional and turning losses, and the compressor efficiency. The mass calculations include the power source, radiator, compressor, fluids, ducting, laser channel, optics, and heat exchanger for all of the systems; and in addition the power conditioner for the EDL's and a focusing mirror for the solar-pumped laser. The results show the major component masses in each system, show which is the lightest system, and provide the necessary criteria for solar-pumped lasers to be lighter than the EDL's. Finally, the masses are compared with results from other studies for a closed-cycle CO2 gasdynamic laser (GDL) and the proposed microwave satellite solar power station (SSPS).

Monson, D. J.↗

Design of Thermophotovoltaic Cells for Optimal System Efficiency, Accounting for Photon Reuse from Front and Back Contacts

We develop a model showing how reflection from both the front and back contacts of thermophotovoltaic (TPV) cells affects the system efficiency. From this foundation we determine the design rules for front grids for TPV cells, and assess the consequences of those rules on cell design and system performance. We show that these design rules are different and more complex than the corresponding design rules for solar photovoltaic (PV) cells, and can lead to substantially different grid design and system performance than if the simpler solar PV design rules were used.

14 SOLAR ENERGY↗

Radiated microwave power transmission system efficiency measurements

The measured and calculated results from determining the operating efficiencies of a laboratory version of a system for transporting electric power from one point to another via a wireless free space radiated microwave beam are reported. The system's overall end-to-end efficiency as well as intermediated conversion efficiencies were measured. The maximum achieved end-to-end dc-to-ac system efficiency was 54.18% with a probable error of + or - 0.94%. The dc-to-RF conversion efficiency was measured to be 68.87% + or - 1.0% and the RF-to-dc conversion efficiency was 78.67 + or - 1.1%. Under these conditions a dc power of 495.62 + or - 3.57 W was received with a free space transmitter antenna receiver antenna separation of 170.2 cm (67 in).

Dickinson, R. M.↗

Fission Gas Monitoring System Efficiency Calibration Summary Report

The Fission Gas Monitoring System was designed to work in conjunction with the Fuel Accident Condition Simulator Furnace and is used to measure fission gas releases during post-irradiation fuel heating tests. A high-purity helium sweep gas is swept past the heated fuel sample in the furnace and routed to a fission gas monitoring system, which cryrogenically traps the krypton (Kr) and xenon (Xe) fission gases. As the radioactive species of the trapped gas decays, high-purity germanium detectors monitor the amount of fission gas in each trap. The primary fission product present in this test is 85Kr, which has a 10.76-year half-life. The presence of 85Kr indicates particle defects and iodine release. There is also the potential for re-irradiating the fuel compacts in the Neutron Radiography Reactor in the Hot Fuel Examination Facility basement. With re-irradiation, it is possible to have xenon fission gas present, specifically 133Xe, which has a 5.243-day half-life. Re-irradiation also produces 131I, which is important for design-basis accidents and regulatory licensing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Total System Performance Ratio—A Systems Based Approach for Evaluating HVAC System Efficiency

The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying Systemic Efficiency using Exergy and Energy Analysis for Ground Source Heat Pumps: Domestic Space Conditioning and Water Heating Applications.

Although air temperatures over land surfaces show wide seasonal and daily variations, the ground, approximately 10 meters below the earth s surface, remains relatively stable in temperature thereby serving as an energy source or sink. Ground source heat pumps can heat, cool, and supply homes with hot water efficiently by utilizing the earth s renewable and essentially inexhaustible energy resources, saving fossil fuels, reducing greenhouse gas emissions, and lowering the environmental footprint. In this paper, evidence is shown that ground source heat pumps can provide up to 79%-87% of domestic hot water energy needs, and up to 77% of space heating needs with the ground s thermal energy resources. The case refers to a 12-month study conducted at a 253 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days and CDD of 723 C-days under simulated occupancy conditions. A single 94.5m vertical bore interfaced the heat pump with the ground. The research shows that this technology is capable of achieving US DOE targets of 25 % and 35% energy savings in HVAC, and in water heating, respectively by 2030. It is also a viable technology to meet greenhouse gas target emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources. The paper quantifies systemic efficiencies using Exergy analysis of the major components, clearly pointing areas for further improvement.

exergy↗

Connected Lighting Systems Efficiency Study: PoE Cable Energy Losses, Part 2

DOE published a report in November 2017 (herein referred to as “Part 1”) summarizing the results of an exploratory study investigating power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the Pacific Northwest National Laboratory (PNNL) Connected Lighting Test Bed (CLTB) in September 2017. The results were analyzed to explore the impact of cable selection on PoE lighting system energy efficiency, as well as the effectiveness of guidelines published by the American National Standards Institute (ANSI) C137 Lighting Systems Committee in 2017. The guidance offered in ANSI C137.3-2017 was found to be effective in limiting cable energy losses to 5% in PoE lighting applications, provided that the average cable length on a project does not exceed 50 m. This Part 2 report summarizes the results of a continued investigation of the power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the PNNL CLTB in July-August 2018. A test setup comprising a PoE switch, a set of luminaires, and a reference meter was again used to test multiple cable models of varying design. The results were analyzed to explore the impact of cable selection and installation practices (e.g., cable bending, cable bundling, and installation in conduit) on PoE lighting system energy efficiency, as well as the effectiveness of the ANSI C137.3 guidelines. Notably, three cables—two of which were shielded—were previously excluded from the Part 1 study due to compatibility issues. All three cables were included in this Part 2 study, along with a fourth model cable introduced in Part 2. In addition, whereas no patch cords were used in Part 1, patch cords were used in some Part 2 testing. The ANSI C137.3 guidance was again shown to effectively limit power losses to less than 5% in the cables tested (varying in AWG, Category, shielding, fire rating, and manufacturer), and AWG again proved to be the most important cable design variable for energy performance, as expected. However, these findings should not be construed as being representative of all cable models and installation practices. For example, energy losses would be greater when cables are connected to patch cords, bundled in conduit, and loaded with powered devices (PDs) approaching 100 W input power. The other key finding was that with 44 W luminaires as PDs and room ambient temperatures below 30°C, cable energy losses were not substantially increased by cable bending or bundling in uninsulated conduit. However, environments with higher ambient temperatures will have greater energy losses due to increased conductor DCR. In addition, product selection and installation practices will have increased importance as PDs approaching 100 W input power—conveyed by a single Ethernet cable—are introduced following publication of the forthcoming Institute of Electrical and Electronics Engineers (IEEE) Standard 802.3bt. The report also provides recommendations and next steps, which include plans for additional PoE cable energy losses testing with higher-power PDs to more fully explore the potential of PoE lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TSPR: The Total System Performance Ratio as a Metric for HVAC System Efficiency

North American energy codes do not typically discriminate between high-performing and poorly-performing HVAC system types, thereby perpetuating the installation of systems with high energy consumption and carbon emissions. The problem is compounded in the US by federal preemption rules, prohibiting state and local energy codes from mandating more efficient equipment than is defined in federal standards. The lack of a total system efficiency metric for HVAC effectively blocks an eventual transition to a performance-based code structure. To surmount this problem, the City of Seattle and Pacific Northwest National Laboratory have developed the Total System Performance Ratio (TSPR) as a proposed amendment to the 2018 Washington State Energy Code. The TSPR is a ratio that compares the annual space heating and cooling load of a building to the annual energy consumed by the building’s entire HVAC system. In the TSPR, target ratios for several building types are calculated in relation to those of the HVAC systems judged to be the most appropriate for each building type. Installation of the lowest-performing HVAC system types will be severely constrained, while exceptional design flexibility will still be provided. With financial support from an international nonprofit, a calculation software tool has been developed as a module of the US DOE Asset Score tool, using simplified building energy modeling. Taken together with whole-system evaluation options for lighting and building envelope systems, a whole-system HVAC performance evaluation would create a path for a transition away from prescriptive-based and towards performance-based codes.

Total System Performance Ratio, Performanced Based↗

Strategies for Wide Bandgap, Inexpensive Transistors for Controlling High-efficiency Systems

Wide bandgap power semiconductor devices offer enormous energy efficiency gains in a wide range of potential applications. However, today, they remain too costly relative to Si devices to gain ubiquitous adoption in many higher power applications. In 2014, ARPA-E launched a new research program entitled SWITCHES, that seeks to enable the development of high voltage (1200 V+), high current (100 A) single die power semiconductor devices that, upon ultimately reaching scale, have the potential to reach functional cost parity ($/A) with silicon power transistors while also offering breakthrough relative circuit performance (low losses, high switching frequencies, and high temperature operation).

36 MATERIALS SCIENCE↗

20% of US electricity from wind will have limited impacts on system efficiency and regional climate

Abstract Impacts from current and future wind turbine (WT) deployments necessary to achieve 20% electricity from wind are analyzed using high resolution numerical simulations over the eastern USA. Theoretical scenarios for future deployments are based on repowering (i.e. replacing with higher capacity WTs) thus avoiding competition for land. Simulations for the contemporary climate and current WT deployments exhibit good agreement with observed electricity generation efficiency (gross capacity factors (CF) from simulations = 45–48%, while net CF for WT installed in 2016 = 42.5%). Under the scenario of quadrupled installed capacity there is a small decrease in system-wide efficiency as indicated by annual mean CF. This difference is approximately equal to that from the two simulation years and may reflect saturation of the wind resource in some areas. WT modify the local near-surface climate in the grid cells where they are deployed. The simulated impact on near-surface climate properties at both the regional and local scales does not increase with increasing WT installed capacity. Climate impacts from WT are modest compared to regional changes induced by historical changes in land cover and to the global temperature perturbation induced by use of coal to generate an equivalent amount of electricity.

17 WIND ENERGY↗