Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STRATIFICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Satellite-Derived Upper-Ocean Stratification Data Set for the Tropical North Atlantic With Potential Applications for Hurricane Intensity Prediction

Upper-ocean stratification strongly impacts vertical mixing and the heat flux between the ocean and atmosphere, especially under extreme conditions of tropical cyclones (TCs). Knowledge of prestorm stratification is important for accurate TC intensity prediction. In situ observations of the tropical ocean have significantly increased in the past decade. However, they are still too sparse to resolve ocean stratification variability in near-real time and on small spatial scales. Here, in this study, based on long-term observations and an ocean reanalysis data set from 2004–2017, we investigate the possibility of retrieving upper-ocean stratification from sea surface temperature (SST), sea surface salinity (SSS), and sea surface height (SSH) using a simple regression method. It is found that more than 90% of the mean seasonal cycle and about 30% to 80% of temperature and salinity stratification anomalies can be reconstructed using surface data from either observations or an ocean reanalysis. Simple regression can be used with satellite observations to create a high-resolution, near-real-time-gridded ocean stratification data set that successfully reproduces both the large and mesoscale variability of ocean stratification. When used in a simple expression for TC-induced SST cooling, the satellite-derived stratification shows improvements over an ocean analysis in terms of variance explained of SST cooling, offering promise as a near-real-time indicator of the ocean's impact on TC intensification.

54 ENVIRONMENTAL SCIENCES↗

ASSESSMENT OF STELLAR STRATIFICATION IN THREE YOUNG STAR CLUSTERS IN THE LARGE MAGELLANIC CLOUD

We present a comprehensive study of stellar stratification in young star clusters in the Large Magellanic Cloud (LMC). We apply our recently developed effective radius method for the assessment of stellar stratification on imaging data obtained with the Advanced Camera for Surveys of three young LMC clusters to characterize the phenomenon and develop a comparative scheme for its assessment in such clusters. The clusters of our sample, NGC 1983, NGC 2002, and NGC 2010, are selected on the basis of their youthfulness, and their variety in appearance, structure, stellar content, and surrounding stellar ambient. Our photometry is complete for magnitudes down to m{sub 814} approx = 23 mag, allowing the calculation of the structural parameters of the clusters, the estimation of their ages, and the determination of their stellar content. Our study shows that each cluster in our sample demonstrates stellar stratification in a quite different manner and at different degree from the others. Specifically, NGC 1983 shows partial segregation, with the effective radius increasing with fainter magnitudes only for the faintest stars of the cluster. Our method on NGC 2002 provides evidence of strong stellar stratification for both bright and faint stars; the cluster demonstrates the phenomenon with the highest degree in the sample. Finally, NGC 2010 is not segregated, as its bright stellar content is not centrally concentrated, the relation of effective radius to magnitude for stars of intermediate brightness is rather flat, and we find no evidence of stratification for its faintest stars. For the parameterization of the phenomenon of stellar stratification and its quantitative comparison among these clusters, we propose the slope derived from the change in the effective radius over the corresponding magnitude range as indicative parameter of the degree of stratification in the clusters. A positive value of this slope indicates mass segregation in the cluster, while a negative or zero value signifies the lack of the phenomenon.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of Sodium Thermal Stratification Models Utilizing the TSTF Benchmark

As a result of certain transient scenarios, a thermally stratified layer of liquid sodium can develop in the bulk coolant volumes of a sodium-cooled fast reactor (SFR). In addition to the effects a stratification layer has on the temperature of the heat transport system, a stratification layer can also influence the transition to and establishment of natural circulation flow, which plays an important role in passive cooling and the inherent safety of a pool-type SFR. Therefore, the ability to accurately capture thermal stratification phenomena is important when demonstrating the safety basis of a pool-type SFR during transient sequences. The present work assesses various computational models with different fidelities in their ability to predict thermal stratification in the upper plenum of an SFR. Each computational model will be assessed using the data generated at the Thermal Stratification Test Facility (TSTF) located at the University of Wisconsin-Madison. Using measured flow rate and inlet temperature data, the measured temperature distributions of the tests are compared to the predictions of the lumped volume-based models in SAS4A/SASSYS-1, a 1D-based model in SAM, and a 3-D computational fluid dynamics (CFD) model using STAR-CCM+. The relative performance of the various computational methods is assessed with respect to key metrics such as bulk coolant temperature distribution and plenum exit temperature. A total of eight tests are analyzed, covering different combinations of flow rates (3 and 10 GPM) and upper internal structure (UIS) configurations (none, solid, porous, and open) The perfect mixing model of SAS4A/SASSYS-1 provides the highest accuracy when the flow rate is high and there is no UIS in the test vessel, as high flow rate injection promotes thermal mixing of the sodium in the test vessel. For most of the analyzed tests, the stratified volume model of SAS4A/SASSYS-1 is able to predict the delay in the outlet temperature drop and temperature distribution in the test vessel by a small number of layers to represent thermal stratification. However, the stratified volume model can only simulate a maximum of three temperature layers within a volume and when a layer approaches the elevation of the outlet, the predicted outlet temperature can demonstrate rapid, non-physical changes. The 1-D axial mixing model of SAM provides results that agree reasonably well with the measured data in the prediction of the temporal evolution of the outlet temperature with the exception of the case with a high flow rate and no UIS. The SAM 1-D model has a similar level of accuracy to CFD results when it comes to predicting the outlet temperature. CFD shows overall good agreement in predicting the temperature distribution in the test vessel and outlet temperature. As CFD can model the test vessel geometry in detail, it performs well in the cases of complex geometries such as tests that included a UIS and internal flow through the UIS resulting in active mixing of the coolant in the test vessel. Each of the models discussed in the present work has the potential to be useful during the various stages of reactor design, analysis, and licensing. The lumped-volume approach can be applied for fast turnaround safety calculations to obtain overall reactor behavior during transients. The 1-D models provide improved accuracy when stratification is expected for a relatively low increase in the computational cost. The CFD model can be utilized for confirmatory analysis of the 1-D model, when experimental measurements are not available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validating a Local Failure Risk Stratification for Use in Prospective Studies of Adjuvant Radiation Therapy for Bladder Cancer

Purpose: To inform prospective trials of adjuvant radiation therapy (adj-RT) for bladder cancer after radical cystectomy, a locoregional failure (LF) risk stratification was proposed. This stratification was developed and validated using surgical databases that may not reflect the outcomes expected in prospective trials. Our purpose was to assess sources of bias that may affect the stratification model's validity or alter the LF risk estimates for each subgroup: time bias due to evolving surgical techniques; trial accrual bias due to inclusion of patients who would be ineligible for adj-RT trials because of early disease progression, death, or loss to follow-up shortly after cystectomy; bias due to different statistical methods to estimate LF; and subgrouping bias due to different definitions of the LF subgroups. Methods and Materials: The LF risk stratification was developed using a single-institution cohort (n=442, 1990-2008) and the multi-institutional SWOG 8710 cohort (n=264, 1987-1998) treated with radical cystectomy with or without chemotherapy. We evaluated the sensitivity of the stratification to sources of bias using Fine-Gray regression and Kaplan-Meier analyses. Results: Year of radical cystectomy was not associated with LF risk on univariate or multivariate analysis after controlling for risk group. By use of more stringent inclusion criteria, 26 SWOG patients (10%) and 60 patients from the single-institution cohort (14%) were excluded. Analysis of the remaining patients confirmed 3 subgroups with significantly different LF risks with 3-year rates of 7%, 17%, and 36%, respectively (P<.01), nearly identical to the rates without correcting for trial accrual bias. Kaplan-Meier techniques estimated higher subgroup LF rates than competing risk analysis. The subgroup definitions used in the NRG-GU001 adj-RT trial were validated. Conclusions: These sources of bias did not invalidate the LF risk stratification or substantially change the model's LF estimates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Studying the effect of the upper internal structure design on thermal stratification in sodium fast reactors

Thermal stratification and mixing in large reactor pools can pose significant issues with regard to operation and safety of nuclear plants. While significant work has been done in this area on light water reactors it is more critical for sodium reactors and there is far less data with regard to low Prandtl number fluids. Here this paper focuses on the effect of the upper internal structure on the formation of thermal stratification in a scaled sodium fast reactor upper plenum. Six different upper internal structure configurations were tested to observe the effect on thermal stratification. The degree of stratification was quantified using the stratification number. Each configuration was tested from low to high flow rates at a temperature difference of 50 and 100 °C. Over this broad array of testing, it was observed that higher flow rates, more porosity in the upper internal structure design, and a smaller temperature difference yielded a lower degree of stratification. This information can be used to aid in the design of the upper internal structure in a sodium fast reactor. Furthermore, this high resolved temperature data can be used to verify models under prototypic low Prandtl numbers.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Smoothing HCCI heat release with vaporization-cooling-induced thermal stratification using ethanol.

Ethanol and ethanol/gasoline blends are being widely considered as alternative fuels for light-duty automotive applications. At the same time, HCCI combustion has the potential to provide high efficiency and ultra-low exhaust emissions. However, the application of HCCI is typically limited to low and moderate loads because of unacceptably high heat-release rates (HRR) at higher fueling rates. This work investigates the potential of lowering the HCCI HRR at high loads by using partial fuel stratification to increase the in-cylinder thermal stratification. This strategy is based on ethanol's high heat of vaporization combined with its true single-stage ignition characteristics. Using partial fuel stratification, the strong fuel-vaporization cooling produces thermal stratification due to variations in the amount of fuel vaporization in different parts of the combustion chamber. The low sensitivity of the autoignition reactions to variations of the local fuel concentration allows the temperature variations to govern the combustion event. This results in a sequential autoignition event from leaner and hotter zones to richer and colder zones, lowering the overall combustion rate compared to operation with a uniform fuel/air mixture. The amount of partial fuel stratification was varied by adjusting the fraction of fuel injected late to produce stratification, and also by changing the timing of the late injection. The experiments show that a combination of 60-70% premixed charge and injection of 30-40 % of the fuel at 80{sup o}CA before TDC is effective for smoothing the HRR. With CA50 held fixed, this increases the burn duration by 55% and reduces the maximum pressure-rise rate by 40%. Combustion stability remains high but engine-out NO{sub x} has to be monitored carefully. For operation with strong reduction of the peak HRR, ISNO{sub x} rises to around 0.20 g/kWh for an IMEP{sub g} of 440 kPa. The single-cylinder HCCI research engine was operated naturally aspirated without EGR at 1200 rpm, and had low residual level using a CR = 14 piston.

09 BIOMASS FUELS↗

Phenological shifts in lake stratification under climate change

One of the most important physical characteristics driving lifecycle events in lakes is stratification. Already subtle variations in the timing of stratification onset and break-up (phenology) are known to have major ecological effects, mainly by determining the availability of light, nutrients, carbon and oxygen to organisms. Despite its ecological importance, historic and future global changes in stratification phenology are unknown. Here, we used a lake-climate model ensemble and long-term observational data, to investigate changes in lake stratification phenology across the Northern Hemisphere from 1901 to 2099. Under the high-greenhouse-gas-emission scenario, stratification will begin 22.0 ± 7.0 days earlier and end 11.3 ± 4.7 days later by the end of this century. It is very likely that this 33.3 ± 11.7 day prolongation in stratification will accelerate lake deoxygenation with subsequent effects on nutrient mineralization and phosphorus release from lake sediments. Further misalignment of lifecycle events, with possible irreversible changes for lake ecosystems, is also likely.

54 ENVIRONMENTAL SCIENCES↗

A perspective on the range of gasoline compression ignition combustion strategies for high engine efficiency and low NOx and soot emissions: Effects of in-cylinder fuel stratification

Many research studies have shown that low temperature combustion in compression ignition engines has the ability to yield ultra-low NOx and soot emissions while maintaining high thermal efficiency. To achieve low temperature combustion, sufficient mixing time between the fuel and air in a globally dilute environment is required, thereby avoiding fuel-rich regions and reducing peak combustion temperatures, which significantly reduces soot and NOx formation, respectively. It has been demonstrated that achieving low temperature combustion with diesel fuel over a wide range of conditions is difficult because of its properties, namely, low volatility and high chemical reactivity. On the contrary, gasoline has a high volatility and low chemical reactivity, meaning it is easier to achieve the amount of premixing time required prior to autoignition to achieve low temperature combustion. In order to achieve low temperature combustion while meeting other constraints, such as low pressure rise rates and maintaining control over the timing of combustion, in-cylinder fuel stratification has been widely investigated for gasoline low temperature combustion engines. The level of fuel stratification is, in reality, a continuum ranging from fully premixed (i.e. homogeneous charge of fuel and air) to heavily stratified, heterogeneous operation, such as diesel combustion. However, to illustrate the impact of fuel stratification on gasoline compression ignition, the authors have identified three representative operating strategies: partial, moderate, and heavy fuel stratification. Thus, this article provides an overview and perspective of the current research efforts to develop engine operating strategies for achieving gasoline low temperature combustion in a compression ignition engine via fuel stratification. In this paper, computational fluid dynamics modeling of the in-cylinder processes during the closed valve portion of the cycle was used to illustrate the opportunities and challenges associated with the various fuel stratification levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical Study of Wake Vortex Behavior in Turbulent Domains with Ambient Stratification

A three-dimensional large eddy simulation model is used to investigate the sensitivity of ambient stratification with turbulence on the behavior of aircraft wake vortices. Modeled ambient turbulence levels range from very weak to moderate, and stratification levels range from strongly stable to unstable. The results of profound significance from this study are: 1) very little sensitivity between vortex linking time and the level of stratification, 2) the mean vortex separation remained nearly constant regardless of stratification and turbulence (at least prior to linking), 3) the wake vortices did not rise regardless of the level of stratification, and 4) for very strong stratification, the vortex stopped descending and quickly dissipated even before vortex linking could occur. These results are supported by experimental data and are contrary to conclusions from other numerical studies that assume laminar flow and/or relatively-low Reynolds numbers.

Switzer, George F.↗

Simulation of Thermal Stratification in BWR Suppression Pools with One Dimensional Modeling Method

The suppression pool in a boiling water reactor (BWR) plant not only is the major heat sink within the containment system, but also provides the major emergency cooling water for the reactor core. In several accident scenarios, such as a loss-of-coolant accident and extended station blackout, thermal stratification tends to form in the pool after the initial rapid venting stage. Accurately predicting the pool stratification phenomenon is important because it affects the peak containment pressure; the pool temperature distribution also affects the NPSHa (available net positive suction head) and therefore the performance of the Emergency Core Cooling System and Reactor Core Isolation Cooling System pumps that draw cooling water back to the core. Current safety analysis codes use zero dimensional (0-D) lumped parameter models to calculate the energy and mass balance in the pool; therefore, they have large uncertainties in the prediction of scenarios in which stratification and mixing are important. While three-dimensional (3-D) computational fluid dynamics (CFD) methods can be used to analyze realistic 3-D configurations, these methods normally require very fine grid resolution to resolve thin substructures such as jets and wall boundaries, resulting in a long simulation time. For mixing in stably stratified large enclosures, the BMIX++ code (Berkeley mechanistic MIXing code in C++) has been developed to implement a highly efficient analysis method for stratification where the ambient fluid volume is represented by one-dimensional (1-D) transient partial differential equations and substructures (such as free or wall jets) are modeled with 1-D integral models. This allows very large reductions in computational effort compared to multi-dimensional CFD modeling. One heat-up experiment performed at the Finland POOLEX facility, which was designed to study phenomena relevant to Nordic design BWR suppression pool including thermal stratification and mixing, is used for validation. Comparisons between the BMIX++, GOTHIC, and CFD calculations against the POOLEX experimental data are discussed in detail.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluating temperature and fuel stratification for heat-release rate control in a reactivity-controlled compression-ignition engine using optical diagnostics and chemical kinetics modeling

We investigated the combustion process in a dual-fuel, reactivity-controlled compression-ignition (RCCI) engine using a combination of optical diagnostics and chemical kinetics modeling to explain the role of equivalence ratio, temperature, and fuel reactivity stratification for heat-release rate control. An optically accessible engine is operated in the RCCI combustion mode using gasoline primary reference fuels (PRF). A well-mixed charge of iso-octane (PRF = 100) is created by injecting fuel into the engine cylinder during the intake stroke using a gasoline-type direct injector. Later in the cycle, n-heptane (PRF = 0) is delivered through a centrally mounted diesel-type common-rail injector. This injection strategy generates stratification in equivalence ratio, fuel blend, and temperature. The first part of this study uses a high-speed camera to image the injection events and record high-temperature combustion chemiluminescence. Moreover, the chemiluminescence imaging showed that, at the operating condition studied in the present work, mixtures in the squish region ignite first, and the reaction zone proceeds inward toward the center of the combustion chamber. The second part of this study investigates the charge preparation of the RCCI strategy using planar laser-induced fluorescence (PLIF) of a fuel tracer under non-reacting conditions to quantify fuel concentration distributions prior to ignition. The fuel-tracer PLIF data show that the combustion event proceeds down gradients in the n-heptane distribution. The third part of the study uses chemical kinetics modeling over a range of mixtures spanning the distributions observed from the fuel-tracer fluorescence imaging to isolate the roles of temperature, equivalence ratio, and PRF number stratification. The simulations predict that PRF number stratification is the dominant factor controlling the ignition location and growth rate of the reaction zone. Equivalence ratio has a smaller, but still significant, influence. Lastly, temperature stratification had a negligible influence due to the NTC behavior of the PRF mixtures.

42 ENGINEERING↗

Experimental studies on the thermal stratification and its influence on BLEVEs

The thermal stratification of Liquefied Petroleum Gas (LPG) and its effect on the occurrence of the boiling liquid expanding vapor explosion (BLEVE) have been investigated experimentally. Stratifications in liquid and vapor occur when the LPG tank is heated. The degree of the liquid stratification {beta} increases with an increasing heat flux and decreasing filling ratio. The effect of stratification on the BLEVE has been examined with depressurization tests of LPG. The results show that the pressure recovery for the stratified LPG ({beta} = 1.4) upon sudden depressurization is much lower than that for the isothermal LPG ({beta} = 1). It can be concluded that the liquid stratification decreases the liquid energy and the occurrence of the BLEVE. (author)

03 NATURAL GAS↗

Percentage of Positive Biopsy Cores: A Better Risk Stratification Model for Prostate Cancer?

Purpose: To assess the prognostic value of the percentage of positive biopsy cores (PPC) and perineural invasion in predicting the clinical outcomes after radiotherapy (RT) for prostate cancer and to explore the possibilities to improve on existing risk-stratification models. Methods and Materials: Between 1993 and 2004, 1,056 patients with clinical Stage T1c-T3N0M0 prostate cancer, who had four or more biopsy cores sampled and complete biopsy core data available, were treated with external beam RT, with or without a high-dose-rate brachytherapy boost at William Beaumont Hospital. The median follow-up was 7.6 years. Multivariate Cox regression analysis was performed with PPC, Gleason score, pretreatment prostate-specific antigen, T stage, PNI, radiation dose, androgen deprivation, age, prostate-specific antigen frequency, and follow-up duration. A new risk stratification (PPC classification) was empirically devised to incorporate PPC and replace the T stage. Results: On multivariate Cox regression analysis, the PPC was an independent predictor of distant metastasis, cause-specific survival, and overall survival (all p < .05). A PPC >50% was associated with significantly greater distant metastasis (hazard ratio, 4.01; 95% confidence interval, 1.86-8.61), and its independent predictive value remained significant with or without androgen deprivation therapy (all p < .05). In contrast, PNI and T stage were only predictive for locoregional recurrence. Combining the PPC ({<=}50% vs. >50%) with National Comprehensive Cancer Network risk stratification demonstrated added prognostic value of distant metastasis for the intermediate-risk (hazard ratio, 5.44; 95% confidence interval, 1.78-16.6) and high-risk (hazard ratio, 4.39; 95% confidence interval, 1.70-11.3) groups, regardless of the use of androgen deprivation and high-dose RT (all p < .05). The proposed PPC classification appears to provide improved stratification of the clinical outcomes relative to the National Comprehensive Cancer Network classification. Conclusions: The PPC is an independent and powerful predictor of clinical outcomes of prostate cancer after RT. A risk model replacing T stage with the PPC to reduce subjectivity demonstrated potentially improved stratification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A status review on the thermal stratification modeling methods for Sodium-cooled Fast Reactors

The thermal stratification phenomenon plays a crucial role in the safety of various nuclear systems, including the Gen-III + Light Water Reactors (LWR) and the Gen-IV reactors. The phenomenon is of particular importance for the pool-type Sodium-cooled Fast Reactors (SFRs) because it may cause neutronic and thermal-hydraulic in- stabilities in the reactor core, or lead to damages of both the reactor vessel and in-vessel components due to the growth of thermal fatigue cracking. More significantly, thermal stratification could impede the establishment of the natural circulation during accidental scenarios and introduce uncertainties to the core safety of SFRs. Efforts for modeling of the thermal stratification in SFRs have been made for decades to prevent or mitigate the damage caused by the phenomenon. This paper gives a review of the advances that have been made in recent 10 years on the computational modeling methods for thermal stratification phenomenon in SFRs. These methods can be generally drawn into two categories. The first one is the system-level methods which provide fast-running but approximate calculations, and the second one is the CFD methods which provide high-resolution calculations at high computational expense. Finally, after introducing the efforts that have been made to improve the one- dimensional (1-D) models, the paper envisioned the possible research directions that could be pursued to enhance the modeling of thermal stratification in the near future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A New 1D Model for Thermal Mixing and Stratification in Advanced Reactor Transients

Thermal mixing and stratification in large pools and enclosures play a critical role in the safety and performance of pool-type nuclear reactors, particularly during transient scenarios involving significant temperature differences between incoming and bulk coolant. Accurate modeling of these phenomena is essential for predicting system behavior and supporting passive safety features such as natural circulation. Here, this paper presents a new 1D model for thermal mixing and stratification, developed and implemented in the SAM code. The model represents a large pool as 1D coolant jet channels and zero-dimensional bulk pool volumes, enabling the simulation of a wide range of flow configurations, including hot and cold jet interactions, stratified layers, and the influence of complex geometries such as ceilings, free surfaces, and internal obstacles. Heat exchange between jet and pool regions is governed by closure relations calibrated against 3D computational fluid dynamics (CFD) simulations. The model improves upon earlier approaches by incorporating time-dependent jet characteristics and capturing the associated delay effects more accurately. Code-to-code comparisons and validation against experimental data from the Thermal Stratification Test Facility demonstrate the model’s accuracy and flexibility. This work offers two key contributions: (1) an efficient and robust method for simulating thermal mixing and stratification at the system level, eliminating the need for external coupling between system analysis codes and CFD, and (2) a significant enhancement of SAM’s capabilities to analyze thermal stratification phenomena in advanced reactor systems.

SAM↗

An efficient modeling method for thermal stratification simulation in a BWR suppression pool

The suppression pool in a BWR plant not only is the major heat sink within the containment system, but also provides major emergency cooling water for the reactor core. In several accident scenarios, such as LOCA and extended station blackout, thermal stratification tends to form in the pool after the initial rapid venting stage. Accurately predicting the pool stratification phenomenon is important because it affects the peak containment pressure; and the pool temperature distribution also affects the NPSHa (Available Net Positive Suction Head) and therefore the performance of the pump which draws cooling water back to the core. Current safety analysis codes use 0-D lumped parameter methods to calculate the energy and mass balance in the pool and therefore have large uncertainty in prediction of scenarios in which stratification and mixing are important. While 3-D CFD methods can be used to analyze realistic 3D configurations, these methods normally require very fine grid resolution to resolve thin substructures such as jets and wall boundaries, therefore long simulation time. For mixing in stably stratified large enclosures, the BMIX++ code has been developed to implement a highly efficient analysis method for stratification where the ambient fluid volume is represented by 1-D transient partial differential equations and substructures such as free or wall jets are modeled with 1-D integral models. This allows very large reductions in computational effort compared to 3-D CFD modeling. The POOLEX experiments at Finland, which was designed to study phenomena relevant to Nordic design BWR suppression pool including thermal stratification and mixing, are used for validation. GOTHIC lumped parameter models are used to obtain boundary conditions for BMIX++ code and CFD simulations. Comparison between the BMIX++, GOTHIC, and CFD calculations against the POOLEX experimental data is discussed in detail.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Winter inverse lake stratification under historic and future climate change

Millions of lakes inversely stratify during winter. Seemingly subtle variations in the duration of winter stratification can have major ecological effects by, for example, altering the vertical distribution of oxygen and nutrients in lakes. Yet, the influence of climate change on winter stratification has been largely unexplored. To fill this knowledge gap, here we used a lake-climate model ensemble to investigate changes in winter stratification from 1901 to 2099 across 12,242 representative lakes situated throughout the Northern Hemisphere. By the end of the 21st century, winter stratification duration is projected to shorten by an average of 18.5–53.9 d under Representative Concentration Pathways (RCPs) 2.6–8.5. Projected changes are faster in warmer geographical regions, in which 35–69% of lakes will no longer inversely stratify by 2070–2099 under RCPs 2.6–8.5. This shortening and loss of winter stratification will likely have numerous implications for lakes, including the misalignment of lifecycle events causing shifts in biodiversity.

54 ENVIRONMENTAL SCIENCES↗

Towards a classification of rank r $\mathscr{N}$ = 2 SCFTs. Part II. Special Kahler stratification of the Coulomb branch

We study the stratification of the singular locus of four dimensional $\mathscr{N}$ = 2 Coulomb branches. We present a set of self-consistency conditions on this stratification which can be used to extend the classification of scale-invariant rank 1 Coulomb branch geometries to two complex dimensions, and beyond. The calculational simplicity of the arguments presented here stems from the fact that the main ingredients needed - the rank 1 deformation patterns and the pattern of inclusions of rank 2 strata - are discrete topological data which satisfy strong self-consistency conditions through their relationship to the central charges of the SCFT. This relationship of the stratification data to the central charges is used here, but is derived and explained in a companion paper by one of the authors. We illustrate the use of these conditions by re-analyzing many previously-known examples of rank 2 SCFTs, and also by finding examples of new theories. The power of these conditions stems from the fact that for Coulomb branch stratifications a conjecturally complete list of physically allowed “elementary slices” is known. By contrast, constraining the possible elementary slices of symplectic singularities relevant for Higgs branch stratifications remains an open problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗