Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STRAINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A resistance strain gage with repeatable and cancellable apparent strain for use to 1500 F

A temperature compensated static strain gauge, which is fabricated from Pd13Cr alloy and a Pt compensator, is being developed and has been tested over a temperature range to 1500 F at NASA-Lewis. The PdCr compensated strain gage has significantly lower apparent strain to 500 F than other high temperature strain gages. The PdCr compensated gage is protected from oxidation by a flame-sprayed alumina-4 wt pct zirconia overcoating. Test Results to 1500 F indicate apparent strain variations of less than 250 micro-epsilon and reproducibility between thermal cycles within 50 micro-epsilon. The apparent strain of the coated PdCr compensated gage can be predicted and cancelled due to its reproducibility and low value.

Lei, Jih-Fen↗

Creep Strain and Strain Rate Response of 2219 Al Alloy at High Stress Levels

As a result of high localized plastic deformation experienced during proof testing in an International Space Station connecting module, a study was undertaken to determine the deformation response of a 2219-T851 roll forging. After prestraining 2219-T851 Al specimens to simulate strains observed during the proof testing, creep tests were conducted in the temperature range from ambient temperature to 107 C (225 F) at stress levels approaching the ultimate tensile strength of 2219-T851 Al. Strain-time histories and strain rate responses were examined. The strain rate response was extremely high initially, but decayed rapidly, spanning as much as five orders of magnitude during primary creep. Select specimens were subjected to incremental step loading and exhibited initial creep rates of similar magnitude for each load step. Although the creep rates decreased quickly at all loads, the creep rates dropped faster and reached lower strain rate levels for lower applied loads. The initial creep rate and creep rate decay associated with primary creep were similar for specimens with and without prestrain; however, prestraining (strain hardening) the specimens, as in the aforementioned proof test, resulted in significantly longer creep life.

Taminger, Karen M. B.↗

Controlled-strain rate tests at very low strain rates of 2618 aluminum at 200 C

Constant strain rate tests and constant load creep tests were performed on 2618 aluminum at 200 C. The strain rates used in the constant strain rate tests were 10 to the minus 6, 10 to the minus 7, 10 to the minum 8, and 10 to the minus 9/sec. Due to the fact that the strain rates in both tests were comparable to each other, the similarities between them can therefore be studied. It was concluded that metals are essentially rate sensitive at elevated temperatures. The traditional definition of creep and plasticity used in the classical creep analysis is actually a reflection of the material behavior under different loading conditions. A constitutive equation based on the test data under one loading condition should work well for other loading conditions as long as the strain rates are in the same range as those under which the material constants are determined.

Ding, J. L.↗

Two-dimensional surface strain measurement based on a variation of Yamaguchi's laser-speckle strain gauge

A novel optical method of measuring 2-D surface strain is proposed. Two linear strains along orthogonal axes and the shear strain between those axes is determined by a variation of Yamaguchi's laser-speckle strain gage technique. It offers the advantages of shorter data acquisition times, less stringent alignment requirements, and reduced decorrelation effects when compared to a previously implemented optical strain rosette technique. The method automatically cancels the translational and rotational components of rigid body motion while simplifying the optical system and improving the speed of response.

Barranger, John P.↗

Application of strain gages to measure adhesive strains through the thickness of an adhesively-bonded stiffened strip

The purpose of the study is to measure the through-the-thickness strain distribution in an adhesively bonded stiffened strip subject to four-point bending and to compare the distribution with predicted results. Small-strain gages are used for measuring the normal strain in the adhesive layer of the strip. A total of 16 120-ohm encapsulated strain gages were mounted on the adhesive layer, and the specimen was loaded quasi-statistically and never to failure. Both the experimental and analytical results show good correlation and, in particular, a high strain gradient acting near the edge of the adhesive layer.

Lopez, O. F.↗

Two-dimensional surface strain measurement based on a variation of Yamaguchi's laser-speckle strain gauge

A novel optical method of measuring 2-D surface strain is proposed. Two linear strains along orthogonal axes and the shear strain between those axes is determined by a variation of Yamaguchi's laser-speckle strain gage technique. It offers the advantages of shorter data acquisition times, less stringent alignment requirements, and reduced decorrelation effects when compared to a previously implemented optical strain rosette technique. The method automatically cancels the translational and rotational components of rigid body motion while simplifying the optical system and improving the speed of response.

Barranger, John P.↗

Strain patterns and strain accumulation along plate margins

Observations of strain accumulation along plate margins in Japan, New Zealand, and the United States indicate that: (1) a typical maximum rate of secular strain accumulation is on the order of 0.3 ppm/a, (2) a substantial part of the strain accumulation process can be attributed to slip at depth on the major plate boundary faults, and (3) some plastic deformation in a zone 100 km or more in width is apparently involved in the strain accumulation process.

Savage, J. C.↗

Strain measurement within a single-lap joint using embedded strain gages

An experimental method used to measure the in-plane normal-axial strains produced within a single-lap joint is described in which a resistance-foil strain gage is embedded within the joint prior to curing of the adhesive. Nominal dimensions of the titanium Ti-6-4 adherends were 0.13 x 2.5 x 12.7 cm and an overlap of 2.5 cm was used. The joint was bonded with FM-300 structural adhesive. The average ultimate shear strength of the gaged specimens and control specimens was 16.1 MPa and 14.1 MPa. A significant advantage of the proposed method is that strains internal to the joint are measured, rather than strains at an external edge. The presence of the gage was found to be not detrimental to bond performance.

Tuttle, M. E.↗

Nondestructive Strain Measurement System Used to Determine Surface Strain on Fibers

Small-diameter structural fibers are being considered as reinforcements for high temperature ceramic matrix composite materials, and thus they require characterization. At the NASA Lewis Research Center, a nondestructive optical technique was used to determine surface strain on a structural fiber, in real time, as it was pulled in a tensile test machine. With this technique, interference or speckle patterns from the laser illuminated fiber test specimen are recorded. As the fiber is pulled, its speckle pattern shifts in proportion to the strain, translation, and rotation components of the sample deformation. Shifting speckle patterns are detected in real time by two linear charge-coupled discharge (CCD) camera arrays, and the images are processed by a hardware correlator. Surface strain is selectively detected on fibers with diameters on the order of 100 mm and can be resolved to 19 microstrain. This system was designed to be robust and compact and generally does not require surface preparation of the structural fibers. For strain detection, two laser beams are positioned incident on the structural fiber being tested, as shown in the photograph, where the test specimen is mounted in a tensile test machine via two coupons. As the fiber is pulled, the speckle pattern produced from each laser beam is detected by one of two CCD arrays located inside the tube on the right side of the photograph.

Tuma, Margaret L.↗

Dose, LET, time and strain dependence of radiation-induced 53BP1 foci in 15 mouse strains ex vivo and associations to in vivo radiation susceptibility

We present a comparative analysis on the repair of radiation-induced DNA damage ex vivo in 15 strains of mice, including 5 inbred reference strains and 10 collaborative-cross strains, of both sexes. Non-immortalized primary skin fibroblasts derived from 76 mice were subjected to both low- and high-LET radiation (0.1, 1 and 4 Gy of X rays; 1.1 and 3 particles/100μm2 of 350 MeV/n 40Ar and 600 MeV/n 56Fe). Automated image quantification of 53BP1 radiation-induced foci (RIF) during the first 4-48 h post-irradiation was performed as a function of dose and LET. Similarly to what we had previously reported for immortalized human cell lines [1], we observed a saturation of RIF number with dose at 4h post-irradiation, with more RIF/Gy for lower LET (X rays and 40Ar) compared to 56Fe. However at later time points (24h and above), the trend was inverted with more RIF/Gy for higher LET. Our data suggest that multiple DSBs cluster into RIF: as the linear density of DSBs increases with LET, so does the probability of having more DSBs per RIF, which makes it more difficult for cells to fully resolve high-LET-induced RIF, explaining the hypersensitivity to high-LET radiation despite a low number of RIF. Taking into account the amount of clustering at a given dose and LET, but also the kinetics of DNA damage repair, we introduced a novel mathematical formalism to evaluate the number of remaining RIF over time. We showed that the newly introduced kinetic metrics can be used as surrogate biomarkers for in vivo radiation toxicity, with potential applications in radiotherapy and human space exploration. In particular, we observed an association between the repairable fraction of RIF measured in vitro and survival levels of immune cells collected from irradiated mice. Moreover, the speed of DNA damage repair correlated with spontaneous cancer incidence data collected from the Mouse Tumor Biology database, suggesting a relationship between the efficiency of DSB repair after irradiation and cancer risk. In addition to the efficacy of repair and persistent RIF levels, even the amount of spontaneous foci without irradiation was shown to be strain dependent, indicating that these phenotypes are at least partially driven by genetics, and supporting their potential as indicators of individual radiation sensitivity. [1] Neumaier, T., et al., PNAS, 2012 (8) 109:443

Radiation, DNA damage, repair kinetics↗

Inversion of the strain-life and strain-stress relationships for use in metal fatigue analysis

The paper presents closed-form solutions (collocation method and spline-function method) for the constants of the cyclic fatigue life equation so that they can be easily incorporated into cumulative damage analysis. The collocation method involves conformity with the experimental curve at specific life values. The spline-function method is such that the basic life relation is expressed as a two-part function, one applicable at strains above the transition strain (strain at intersection of elastic and plastic lines), the other below. An illustrative example is treated by both methods. It is shown that while the collocation representation has the advantage of simplicity of form, the spline-function representation can be made more accurate over a wider life range, and is simpler to use.

Manson, S. S.↗

A resistance strain gage with repeatable apparent strain to 800 C

Experimental PdCr temperature-compensated resistance static-strain gages are described. The gages are developed in both fine-wire and thin-film forms. It is found that a PdCr wire strain gage coated with a flame-sprayed mixture of alumina and 4 wt pct zirconia demonstrates the smallest variation in and the best repeatability of apparent strain among the existing gages used at temperatures up to 800 C. Results of preliminary tests indicate uncompensated uncoated thin-film gages have potential usefulness at temperatures up to 1000 C.

Lei, J.-F.↗

High temperature strain measurement with a resistance strain gage

A PdCr based electrical resistance strain gage was demonstrated in the laboratory to be a viable sensor candidate for static strain measurement at high temperatures. However, difficulties were encountered while transferring the sensor to field applications. This paper is therefore prepared for recognition and resolution of the problems likely to be encountered with PdCr strain gages in field applications. Errors caused by the measurement system, installation technique and lead wire attachment are discussed. The limitations and some considerations related to the temperature compensation technique used for this gage are also addressed.

Lei, Jih-Fen↗

Systems and Methods for Implementing Bulk Metallic Glass-Based Strain Wave Gears and Strain Wave Gear Components

Bulk metallic glass-based strain wave gears and strain wave gear components. In one embodiment, a strain wave gear includes: a wave generator; a flexspline that itself includes a first set of gear teeth; and a circular spline that itself includes a second set of gear teeth; where at least one of the wave generator, the flexspline, and the circular spline, includes a bulk metallic glass-based material.

Hofmann, Douglas C.↗

Systems and Methods for Implementing Tailored Metallic Glass-Based Strain Wave Gears and Strain Wave Gear Components

Systems and methods in accordance with embodiments of the invention implement tailored metallic glass-based strain wave gears and strain wave gear components. In one embodiment, a method of fabricating a flexspline of a strain wave gear includes: forming a MG-based composition into a flexspline using one of a thermoplastic forming technique and a casting technique; where the forming of the MG-based composition results in a formed MG-based material; where the formed flexspline is characterized by: a minimum thickness of greater than approximately 1 mm and a major diameter of less than approximately 4 inches.

Hofmann, Douglas C.↗

A plane strain analysis of the blunted crack tip using small strain deformation plasticity theory

A deformation plasticity analysis of the tip region of a blunted crack in plane strain is presented. The power hardening material is incompressible both elastically and plastically, in order to simulate behavior of a stress freezing material above critical temperature. Stress and displacement fields surrounding the crack tip are presented. The results indicate that the maximum stress seen at the crack tip is indeed limited and is determined by the tensile properties; however, the scale over which the stresses act is dependent on the loading. Comparisons are good between the forward crack tip displacement and micro-fractographic measurments of stretch zones observed in plane strain fracture toughness tests.

Mcgowan, J. J.↗