Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Some New Results on Stopping Power for Fast Ions

Using our large collection of experimental stopping power data, we compare these data with various theories and stopping codes, in order to judge the quality of both data and theories. We discuss the influence of the state of aggregation of the target upon stopping power, and the importance of choosing the best value of the ionization potential of water for medical applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

A theoretical model for calculation of molecular stopping power

A modified local plasma model is established. The Gordon-Kim's molecular charged density model is employed to obtain a formula to evaluate the stopping power of many useful molecular systems. The stopping power of H2 and He gas was calculated for incident proton energy ranging from 100 keV to 2.5 MeV. The stopping power of O2, N2, and water vapor was also calculated for incident proton energy ranging from 40 keV. to 2.5 MeV. Good agreement with experimental data was obtained. A discussion of molecular effects leading to department from Bragg's rule is presented. The equipartition rule and the effect of nuclear momentum recoiling in stopping power are also discussed.

Xu, Y. J.↗

Validation of the single-event method for low-energy electron transport via stopping power calculations with $\mathrm{MCNP}$

Monte Carlo simulations of low-energy ( <50 keV) electron transport in matter are essential for a broad range of application fields. Several Monte Carlo codes have developed specialized treatments for this case, but a comprehensive validation of low-energy electron transport for general-purpose simulations remains lacking in the literature. One approach to accomplish this validation is calculation of stopping power using low-energy electron transport physics, as stopping power is a fundamental radiation transport quantity which must be simulated accurately for nearly any application. Here in this work, we use the Monte Carlo N-Particle (MCNP) radiation transport code with the single-event method for electron transport to calculate stopping powers of low-energy electrons (50 eV to 30 keV) in 41 elemental solids, 14 compound solids, and five rare gas solids, comparing simulation results to published semi-empirical stopping power calculations from optical measurements. In general, the simulations give good agreement (typically within ±10%) with semi-empirical stopping power values at higher energies: 300 eV and above for most elemental solids, 1 keV and above for compound solids, and 400 eV and above for rare gas solids. Agreement between MCNP and semi-empirical values is worse below these energies. The most significant source of error is the EPRDATA14 cross section data, which does not account for changes in electronic structure due to solid-state bonding, particularly in compound materials. The simplistic model of atomic excitation used to generate the EPRDATA14 cross sections is another key source of error. Additionally, the breakdown of the continuous slowing-down approximation introduces significant uncertainty at low energies, although this is a limitation of the calculation method and not of the simulation procedure. Accounting for these and other uncertainty sources, the single event method in MCNP is robust and able to give good accuracy for a variety of low-energy electron transport problems through diverse kinds of materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of the Stopping Power of Water for Carbon Ions Using Inverted Doppler Shift Attenuation

Carbon ion therapy has gained importance in cancer treatment due to its locally well confined dose distribution, but there is a significant lack of experimental data which is needed for dose calculations and estimation of biological damage. Since tissue is mainly comprised of water, the energy-dependent stopping power of water is the critical measure. Importantly, previous data gathered from experiments with light ions has been limited to water vapour and ice and neglected water in its liquid phase. Additionally, theoretical models regarding the stopping power cannot yet describe the complex charge transfer interactions of the projectile at velocities in the range of the mean velocity of the valence electrons of the traversed medium. There are also discrepancies in the amount of phase effects concerning water and water vapour cross sections. Despite its importance there exists no experimental data for the stopping power of water for carbon ions in the energy region between 1 MeV and 5 MeV. This may be due to the short track length of carbon ions which makes traditional transmission experiments unfeasible. Therefore a project was launched to measure the stopping power of liquid water for carbon ions in the vicinity of the Bragg peak which corresponds to the energy regime of the maximum stopping power. For this measurement the inverted Doppler shift attenuation method was used. This uses the gamma quanta emitted from excited carbon nuclei which are produced by means of the {sup 12}C(α,α'){sup 12}C* reaction. The recorded γ-spectra contain the information of the projectiles velocity at the time they decay to their ground state and an internal clock provided by the exponential decay law. The deceleration of the projectile is directly connected to the stopping power which can be determined with this method as a function of the projectiles kinetic energy. Further measurements have been carried out to improve the experimental method. The setup and the preliminary results of this study will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-415: Experimental Determination of the Relative Stopping Power of TRUFILL N-BCA Liquid Embolic System in a Clinical Proton Beam

Purpose: Patients who undergo n-BCA glue embolization as part of treatment for AVMs are later referred for proton therapy. Knowing the relative stopping power of the glue accurately allows us to perform accurate dose calculations. In this study we experimentally determine the relative stopping power of an n-BCA mixture in a 126 MeV and 149.6 MeV proton beams. Methods: One unit of the TRUFILL™ n-BCA liquid embolic system consists of 1g unit of n-BCA, 1g unit of Tantalum powder and one 10mL vial of Ethiodized oil. The physician mixed 3:1 Ethiodized oil to n-BCA. Five units (20cc) of the n-BCA liquid embolic glue were prepared and placed in a 6cm x 3cm x3cm Lucite container. The container was placed in front of a water tank in the proton beam path. A diamond detector (active volume 0.004mm3) was used to measure distal edge of depth dose of a modulated 126 MeV proton beam collimated using a 3cm brass aperture. The procedure was repeated with a container carrying the same amount of water placed in front of the water tank. The difference in the depth dose measured with glue and with water was used to determine the relative stopping power of the glue. The same determination was done earlier at 149.6 MeV using a different smaller sample (4cc) of n-BCA. Results: The relative stopping power of this particular n-BCA mixture was determined to be 1.06 at both 126 MeV and 149.6 MeV. We are working on obtaining the composition data of the n-BCA glue so we can perform Monte Carlo calculations. Conclusion: Accurate value of the stopping power of the n-BCA glue in the proton beam was determined to be 1.06. It will improve the accuracy of dose calculations in proton radiosurgery procedures on AVM patients with n-BCA embolization.

60 APPLIED LIFE SCIENCES↗

Stopping power measurements with the Time-of-Flight (ToF) technique

In our review of measurements of the stopping power of ions in matter is presented along with new measurements of the stopping powers of O, Si, Ti, and Au ions in self-supporting thin foils of SiO 2 , Nb 2 O 5 , and Ta 2 O 5 . Moreover, a Time-of-Flight system at the Ion Beam Materials Laboratory at the University of Tennessee, Knoxville, was used in transmission geometry in order to reduce experimental uncertainties. Finally, the resulting stopping powers show good precision and accuracy and corroborate previously quoted values in the literature. New stopping data are determined.

36 MATERIALS SCIENCE↗

Influence of a strong laser field on Coulomb explosion and stopping power of energetic H{sub 3}{sup +} clusters in plasmas

The influence of a high-intensity laser field on the Coulomb explosion and stopping power for a swift H{sub 3}{sup +} cluster ion in a plasma target is studied by means of the molecular dynamic (MD) method based on the linearized Vlasov-Poisson theory. Excitations of the plasma are described by the classical plasma dielectric function. In the presence of the laser field, the general expressions for the induced potential in the target and the interaction force among the ions within the cluster are derived. Based on the numerical solution of the equations of motion for the constituent ions, the Coulomb explosion patterns and the cluster's stopping power are discussed for a range of laser parameters. Numerical results show that the laser field affects the correlation between the ions and contributes to weaken the wake effect and the stopping power as compared to the laser-free case. On the other hand, the stopping power ratio of H{sub 3}{sup +} cluster is higher than the situation of dicluster of H{sub 2}{sup +} due to the vicinage effect in the cluster.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intermediate energy proton stopping power for hydrogen molecules and monoatomic helium gas

Stopping power in the intermediate energy region (100 keV to 1 MeV) was investigated, based on the work of Lindhard and Winther, and on the local plasma model. The theory is applied to calculate stopping power of hydrogen molecules and helium gas for protons of energy ranging from 100 keV to 2.5 MeV. Agreement with the experimental data is found to be within 10 percent.

Xu, Y. J.↗

Intermediate energy proton stopping power for hydrogen molecules and monoatomic helium gas

Stopping power in the intermediate energy region (100 keV to 1 MeV) was investigated, based on the work of Lindhard and Winther, and on the local plasma model. The theory is applied to calculate stopping power of hydrogen molecules and helium gas for protons of energy ranging from 100 keV to 2.5 MeV. Agreement with the experimental data is found to be within 10 percent. Previously announced in STAR as N84-16955

Xu, Y. J.↗

Time-dependent orbital-free density functional theory for electronic stopping power: Comparison to the Mermin-Kohn-Sham theory at high temperatures

Electronic stopping power in warm dense matter can affect energy transport and heating in astrophysical processes and internal confinement fusion. For cold condensed matter systems, stopping power can be modeled from first-principles using real-time time-dependent density functional theory (DFT). However, high temperatures (10's to 100's of eV) may be computationally prohibitive for traditional Mermin-Kohn-Sham DFT. New experimental measurements in the warm dense regime motivates the development of first-principles approaches, which can reach these temperatures. Here, we have developed a time-dependent orbital-free density functional theory, which includes a novel nonadiabatic and temperature-dependent kinetic energy density functional, for the simulation of stopping power at any temperature. The approach is nonlinear with respect to the projectile perturbation, includes all ions and electrons, and does not require a priori determination of screened interaction potentials. Finally, our results compare favorably with Kohn-Sham for temperatures in the WDM regime, especially nearing 100 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stopping Power of Different Ions in Si Measured with a Bulk Sample Method and Bayesian Inference Data Analysis

The accuracy of ion beam analysis experiments depends critically on the stopping power values available. While for H and He ions accuracies normally better than 5% are achieved by usual interpolative schemes such as SRIM, for heavier ions the accuracy is worse. One of the main reasons is that the experimental data bases are very sparse, even for important materials such as Si. New measurements are therefore needed. Measurement of stopping power is often made with transmission in thin films, with the usual problems of film thickness homogeneity. We have previously developed an alternative method based on measuring bulk spectra, and fitting the yield by treating the stopping power as a fit parameter in a Bayesian inference Markov chain Monte Carlo procedure included in the standard IBA code NDF. We report on improvements of the method and on its application to the determination of the stopping power of {sup 7}Li in Si. To validate the method, we also apply it to the stopping of {sup 4}He in Si, which is known with 2% accuracy.

36 MATERIALS SCIENCE↗

Reproducibility of real-time time-dependent density functional theory calculations of electronic stopping power in warm dense matter

Real-time time-dependent density functional theory (TDDFT) is widely considered to be the most accurate available method for calculating electronic stopping powers from first principles, but there have been relatively few assessments of the consistency of its predictions across different implementations. This problem is particularly acute in the warm dense regime, where computational costs are high and experimental validation is rare and resource intensive. We report a comprehensive cross-verification of stopping power calculations in conditions relevant to inertial confinement fusion conducted using four different TDDFT implementations. We find excellent agreement among both the post-processed stopping powers and relevant time-resolved quantities for alpha particles in warm dense hydrogen. We also analyze sensitivities to a wide range of methodological details, including the exchange-correlation model, pseudopotentials, initial conditions, observable from which the stopping power is extracted, averaging procedures, projectile trajectory, and finite-size effects. We show that among these details, pseudopotentials, trajectory-dependence, and finite-size effects have the strongest influence, and we discuss different strategies for controlling the latter two considerations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 11: Commissioning of a system for the measurement of electron stopping powers

Purpose: To develop the techniques required to experimentally determine electron stopping powers for application in primary standards and dosimetry protocols. Method and Materials: A large-volume HPGe detector system (>80% efficiency) was commissioned for the measurement of high energy (5–35 MeV) electron beams. As a proof of principle the system was used with a Y-90/Sr-90 radioactive source. Thin plates of absorbing material (< 0.1 gcm-2) were then placed between the source and detector and the emerging electron spectrum was acquired. The full experimental geometry was modelled using the EGSnrc package to validate the detector design, optimize the experimental setup and compare measured and calculated spectra. Results: The biggest challenge using a beta source was to identify a robust spectral parameter to determine for each measurement. An end-point-fitting routine was used to determine the maximum energy, Emax, of the beta spectrum for each absorber thickness t. The parameter dEmax/dt is related to the electron stopping power and the same routine was applied to both measured and simulated spectra. Although the standard uncertainty in dEmax/dt was of the order of 5 %, by taking the ratio of measured and Monte Carlo values for dEmax/dt the uncertainty of the fitting routine was eliminated and the uncertainty was reduced to less than 2 %. The agreement between measurement and simulation was within this uncertainty estimate. Conclusion: The investigation confirmed the experimental approach and demonstrated that EGSnrc could accurately determine correction factors that will be required for the final measurement setup in a linac beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nonlinear stopping power for ions moving in magnetized two-component plasmas

Energy losses of test particles in magnetized two-component plasmas are investigated by means of particle-in-cell (PIC) simulations, taking into account the dynamic polarization effects of both the plasma ions and electrons. The influences of the magnetic field, the angle between the test particle velocity and magnetic field, and certain plasma parameters on the nonlinear stopping power are studied. Comparisons are made between the PIC simulations and the linearized dielectric theory to show the nonlinear effects on the stopping power. Simulation results show that the dynamic polarization effects of the plasma ions become significant and contribute mainly to the nonlinear stopping power for low particle velocities and strong magnetic field. The nonlinear effects are found to enhance the stopping power in low particle velocity regions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Coulomb coupling on stopping power and a link to macroscopic transport

Molecular dynamics simulations are used to assess the influence of Coulomb coupling on the energy evolution of charged projectiles in the classical one-component plasma. The average projectile kinetic energy is found to decrease linearly with time when ν α /ω p ≲ 10 –2 , where να is the Coulomb collision frequency between the projectile and the medium, and ω p is the plasma frequency. Stopping power is obtained from the slope of this curve. In comparison to the weakly coupled limit, strong Coulomb coupling causes the magnitude of the dimensionless stopping power, ( a/k B T ) dE / dx , to increase, the Bragg peak to shift to several times the plasma thermal speed, and for the stopping power curve to broaden substantially. The rate of change of the total projectile kinetic energy averaged over many independent simulations is shown to consist of two measurable components: a component associated with a one-dimensional friction force and a thermal energy exchange rate. In the limit of a slow and massive projectile, these can be related to the macroscopic transport rates of self-diffusion and temperature relaxation in the plasma. Simulation results are compared with available theoretical models for stopping power, self-diffusion, and temperature relaxation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-J-195: On the Performance of Four Dual Energy CT Formalisms for Extracting Proton Stopping Powers

Purpose: Dual energy CT can predict stopping power ratios (SPR) for ion therapy treatment planning. Several approaches have been proposed recently, however accuracy and practicability in a clinical workflow are unaddressed. The aim of this work is to provide a fair comparison of available approaches in a human-like phantom to find the optimal method for tissue characterization in a clinical situation. Methods: The SPR determination accuracy is investigated using simulated DECT images. A virtual human-like phantom is created containing 14 different standard human tissues. SECT (120 kV) and DECT images (100 kV and 140 kV Sn) are simulated using the software ImaSim. The single energy CT (SECT) stoichiometric calibration method and four recently published calibration-based DECT methods are implemented and used to predict the SPRs from simulated images. The difference between SPR predictions and theoretical SPR are compared pixelwize. Mean, standard deviation and skewness of the SPR difference distributions are used as measures for bias, dispersion and symmetry. Results: The average SPR differences and standard deviations are (0.22 ± 1.27)% for SECT, and A) (−0.26 ± 1.30)%, B) (0.08 ± 1.12)%, C) (0.06 ± 1.15)% and D) (−0.05 ± 1.05)% for the four DECT methods. While SPR prediction using SECT is showing a systematic error on SPR, the DECT methods B, C and D are unbiased. The skewness of the SECT distribution is 0.57%, and A) −0.19%, B) −0.56%, C) −0.29% and D) −0.07% for DECT methods respectively. Conclusion: The here presented DECT methods B, C and D outperform the commonly used SECT stoichiometric calibration. These methods predict SPR accurately without a bias and within ± 1.2% (68th percentile). This indicates that DECT potentially improves accuracy of range predictions in proton therapy. A validation of these findings using clinical CT images of real tissues is necessary.

60 APPLIED LIFE SCIENCES↗

Theoretical studies on the stopping power of deuterium-tritium mixed with uranium plasmas for α particles

The stopping power of a compressed and highly ionized deuterium-tritium (DT) and uranium (U) plasma for α particles at very high temperatures (T = 5 keV) is examined theoretically with the dimensional continuation method. We show that with increasing density of U, both the magnitude and width of the resonance peak in the stopping power (as a function of the α particle energy), increases because of the ions, while the penetration distance of the α particles decreases. A simple relation of decreasing penetration distance as a function of plasma density is observed, which may be useful for inertial confinement fusion experiments. Moreover, by comparing the results with the case of a DT plasma mixed with beryllium, we find that the effect of a higher Z plasma is stronger, with regard to energy loss as well as the penetration distance of α particles, than that of a lower Z plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-37: Combining Proton Radiography and X-Ray CT Information to Better Estimate Relative Proton Stopping Power in a Clinical Environment

Purpose: In standard proton therapy clinical practice, proton stopping power uncertainties are in the order of 3.5%, which affects the ability of placing the proton Bragg peak at the edge of the tumor. The innovating idea of this project is to approach the uncertainty problem in RSP by using combined information from X-ray CT and proton radiography along a few beam angles. In addition, this project aims to quantify the systematic error introduced by the theoretical models (Janni, ICRU49, Bischel) for proton stopping power in media. Methods: A 3D phantom of 36 cm3 composed of 9 materials randomly placed is created. Measured RSP values are obtained using a Gammex phantom with a proton beam. Theoretical RSP values are calculated with Beth-Block equation in combination with three databases (Janni, ICRU49 and Bischel). Clinical RSP errors are simulated by introducing a systematic (1.5%, 2.5%, 3.5%) and a random error (+/−0.5%) to the theoretical RSP. A ray-tracing algorithm uses each of these RSP tables to calculate energy loss for proton crossing the phantom through various directions. For each direction, gradient descent (GD) method is done on the clinical RSP table to minimize the residual energy difference between the simulation with clinical RSP and with theoretical RSP. The possibility of a systematic material dependent error is investigated by comparing measured RSP to theoretical RSP as calculated from the three models. Results: Using 10,000 iterations on GD algorithm, RSP differences between theoretical values and clinical RSP have converged (<1%) for each error introduced. Results produced with ICRU49 have the smallest average difference (0.021%) to the measured RSP. Janni (1.168%) and Bischel (−0.372%) database shows larger systematic errors. Conclusion: Based on these results, ray-tracing optimisation using information from proton radiography and X-ray CT demonstrates a potential to improve the proton range accuracy in a clinical environment.

07 ISOTOPE AND RADIATION SOURCES↗