Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SQUID DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Proximity effect bilayer nano superconducting quantum interference devices for millikelvin magnetometry

Superconducting quantum interference devices (SQUIDs) incorporating thin film nanobridges as weak links have sensitivities approaching that required for single spin detection at 4.2 K. However, due to thermal hysteresis they are difficult to operate at much lower temperatures which hinder their application to many quantum measurements. To overcome this, we have developed nanoscale SQUIDs made from titanium-gold proximity bilayers. We show that their electrical properties are consistent with a theoretical model developed for heat flow in bilayers and demonstrate that they enable magnetic measurements to be made on a sample at system temperatures down to 60 mK.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Optical transmission modules for multi-channel superconducting quantum interference device readouts

We developed an optical transmission module consisting of 16-channel analog-to-digital converter (ADC), digital-noise filter, and one-line serial transmitter, which transferred Superconducting Quantum Interference Device (SQUID) readout data to a computer by a single optical cable. A 16-channel ADC sent out SQUID readouts data with 32-bit serial data of 8-bit channel and 24-bit voltage data at a sample rate of 1.5 kSample/s. A digital-noise filter suppressed digital noises generated by digital clocks to obtain SQUID modulation as large as possible. One-line serial transmitter reformed 32-bit serial data to the modulated data that contained data and clock, and sent them through a single optical cable. When the optical transmission modules were applied to 152-channel SQUID magnetoencephalography system, this system maintained a field noise level of 3 fT/√Hz @ 100 Hz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of spin canting in Li{sub 3}Fe{sub 2}(PO{sub 4}){sub 3} with Mössbauer spectroscopy under 5 T

Li{sub 3}Fe{sub 2}(PO{sub 4}){sub 3} has been actively studied as a Lithium ion battery cathode material for the next-generation energy storage application. Here, we have investigated the changes of magnetic coupling between two different magnetic sub-lattices in Li{sub 3}Fe{sub 2}(PO{sub 4}){sub 3} with x-ray diffraction (XRD), superconducting quantum interference device (SQUID), and Mössbauer spectroscopy measurements. The experimental XRD pattern was analyzed using Rietveld refinement, confirming single phase. In order to investigate the magnetic property, the SQUID measurement under applied field of 5 T was performed between 4.2 and 295 K. From the temperature-dependent zero-field-cooled and field-cooled magnetization curves, we observed the magnetization decreasing with increasing temperature up to T{sub min} = 13 K, at which the magnetization showed a minimum value. With continuing increase in temperature, the magnetization starts increasing with a maximum value at T{sub max} = 28 K and beyond T{sub max}, the magnetization decreases with the further increase in temperature. Based on the experimentally measured Mössbauer spectra, we identified that the ratios of first and sixth to second and fifth absorption lines were identical around T{sub min}, while with increasing temperature the area of second and fifth absorption line rapidly decreased up to T{sub max}. Our study suggests that the spin canting angle between the applied field and hyperfine field of Li{sub 3}Fe{sub 2}(PO{sub 4}){sub 3} is constant up to T{sub min}. However, the spin canting angle starts decreasing with increasing temperature, reaching a minimum value at T{sub max}, and beyond T{sub max} it is increasing. We expect that around T{sub max}, the ferrimagnetically coupled spin arrangement is appeared to be collinear along the applied field direction under applied field of 5 T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication and long-wavelength characterization of neat and chemically modified graphene

Graphene, a single- or several layer-thick carbon, attracts significant research activity because of its exceptional material properties. Graphene is a promising material for optoelectronic applications. Neat graphene demonstrates potential as a material for long wavelength photodetectors working at elevated temperatures. Chemical modification of graphene opens up many new applications of this material in electronics, in new composite materials, and in new catalysts for different chemical processes. Chemical vapor deposition-grown large-area graphene can be successfully modified with the creation of benzyne attachments. The investigation of microwave properties is an important part of graphene research. Two variants of near-field long wavelength microscopy were found efficient with graphene. Measurements with a probe formed by an electrically open end of a 4 GHz half-lambda parallel-strip transmission line resonator allow the implementation of an electrodynamic model of graphene microwave impedance. The results of near-field scanning superconducting quantum interference device (SQUID) RF microscopy of graphite and graphene at 200 MHz shed light on mechanisms of AC graphene response: screening currents induced in graphene by an external RF magnetic field tend to localize near structural defects.

36 MATERIALS SCIENCE↗

Investigation and optimization of low-frequency noise performance in readout electronics of dc superconducting quantum interference device

We investigated and optimized the low-frequency noise characteristics of a preamplifier used for readout of direct current superconducting quantum interference devices (SQUIDs). When the SQUID output was detected directly using a room-temperature low-voltage-noise preamplifier, the low-frequency noise of a SQUID system was found to be dominated by the input current noise of the preamplifiers in case of a large dynamic resistance of the SQUID. To reduce the current noise of the preamplifier in the low-frequency range, we investigated the dependence of total preamplifier noise on the collector current and source resistance. When the collector current was decreased from 8.4 mA to 3 mA in the preamplifier made of 3 parallel SSM2220 transistor pairs, the low-frequency total voltage noise of the preamplifier (at 0.1 Hz) decreased by about 3 times for a source resistance of 30 Ω whereas the white noise level remained nearly unchanged. Since the relative contribution of preamplifier's input voltage and current noise is different depending on the dynamic resistance or flux-to-voltage transfer of the SQUID, the results showed that the total noise of a SQUID system at low-frequency range can be improved significantly by optimizing the preamplifier circuit parameters, mainly the collector current in case of low-noise bipolar transistor pairs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source localization of brain activity using helium-free interferometer

To detect extremely small magnetic fields generated by the human brain, currently all commercial magnetoencephalography (MEG) systems are equipped with low-temperature (low-T{sub c}) superconducting quantum interference device (SQUID) sensors that use liquid helium for cooling. The limited and increasingly expensive supply of helium, which has seen dramatic price increases recently, has become a real problem for such systems and the situation shows no signs of abating. MEG research in the long run is now endangered. In this study, we report a MEG source localization utilizing a single, highly sensitive SQUID cooled with liquid nitrogen only. Our findings confirm that localization of neuromagnetic activity is indeed possible using high-T{sub c} SQUIDs. We believe that our findings secure the future of this exquisitely sensitive technique and have major implications for brain research and the developments of cost-effective multi-channel, high-T{sub c} SQUID-based MEG systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superconducting inductive displacement detection of a microcantilever

We demonstrate a superconducting inductive technique to measure the displacement of a micromechanical resonator. In our scheme, a type I superconducting microsphere is attached to the free end of a microcantilever and approached to the loop of a dc Superconducting Quantum Interference Device (SQUID) microsusceptometer. A local magnetic field as low as 100 μT, generated by a field coil concentric to the SQUID, enables detection of the cantilever thermomechanical noise at 4.2 K. The magnetomechanical coupling and the magnetic spring are in good agreement with image method calculations assuming pure Meissner effect. These measurements are relevant to recent proposals of quantum magnetomechanics experiments based on levitating superconducting microparticles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic anisotropy in ultrathin Fe films on GaAs, ZnSe, and Ge (001) substrates

We discuss magnetic anisotropy parameters of ferromagnetic body-centered cubic (bcc) Fe films grown by molecular beam epitaxy (MBE) on (001) substrates of face-centered cubic (fcc) GaAs, ZnSe, and Ge. High-quality MBE growth of these metal/semiconductor combinations is made possible by the fortuitous atomic relationship between the bcc Fe and the underlying fcc semiconductor surfaces, resulting in excellent lattice match. Magnetization measurements by superconducting quantum interference device (SQUID) indicate that the Fe films grown on (001) GaAs surfaces are characterized by a very strong uniaxial in-plane anisotropy; those grown on (001) Ge surfaces have a fully cubic anisotropy; and Fe films grown on ZnSe represent an intermediate case between the preceding two combinations. Ferromagnetic resonance measurements carried out on these three systems provide a strikingly clear quantitative picture of the anisotropy parameters, in excellent agreement with the SQUID results. Based on these results, we propose that the observed anisotropy of cubic Fe films grown in this way results from the surface reconstruction of the specific semiconductor substrate on which the Fe film is deposited. These results suggest that, by controlling surface reconstruction of the substrate during the MBE growth, one may be able to engineer the magnetic anisotropy in Fe, and possibly also in other MBE-grown ferromagnetic films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental studies and micromagnetic simulations of electrodeposited Co nanotube arrays

Magnetic hollow nanotubes of cobalt forming close-packed arrays are synthesized by controlling the growth during electrodeposition in AAO template. Superconducting quantum interference device (SQUID) magnetometry is used to experimentally measure the static magnetization of the array of nanotubes. Excellent qualitative agreements of SQUID and micromagnetic simulations for static measurements are observed. This motivates us to evaluate dynamic response measurements via micromagnetic simulations. The coercivity simulated along the longitudinal axis of the nanotube is found increase with the length of isolated as well as for array of nanotubes. The effect of interactions is also clearly observed both in static as well as in dynamic evaluations. The interactions cause reduction in coercivity along with the switching which depends upon the length of the nanotubes. The calculation for FMR modes also indicates that propagation of the spin waves are greatly influenced by the hollow centre of nanotube as compare to nanowire and support to maintain the stable vortex configuration. For array of nanotubes, multiple peaks are found over larger number of frequencies which is anticipated due the interactions between nanotubes. Simulation for bias field and angular dependence of spin wave modes also yields a significant influenced by the presence of neighbouring nanotubes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cryogen-free ultralow-field superconducting quantum interference device magnetic resonance imaging system

Magnetic resonance imaging (MRI) at microtesla fields using superconducting quantum interference device (SQUID) detection has previously been demonstrated, and advantages have been noted. Although the ultralow-field SQUID MRI technique would not need the heavy superconducting magnet of conventional MRI systems, liquid helium required to cool the low-temperature detector still places a significant burden on its operation. We have built a prototype cryocooler-based SQUID MRI system that does not require a cryogen. The SQUID detector and the superconducting gradiometer were cooled down to 3.7 K and 4.3 K, respectively. We describe the prototype design, characterization, a phantom image, and areas of further improvements needed to bring the imaging performance to parity with conventional MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Increasing dynamic range of digital-to-analog converter using a superconducting quantum interference device

Responses of a superconducting quantum interference device (SQUID) are periodically dependent on magnetic flux coupling to its superconducting ring and the period is a flux quantum (Φ{sub o} = h/2e, where h and e, respectively, express Planck's constant and elementary charge). Using this periodicity, we had proposed a digital to analog converter using a SQUID (SQUID DAC) of first generation with linear current output, interval of which corresponded to Φ{sub o}. Modification for increasing dynamic range by interpolating within each interval is reported. Linearity of the interpolation was also based on the quantum periodicity. A SQUID DAC with dynamic range of about 1.4 × 10{sup 7} was created as a demonstration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range

In several low-field Nuclear Magnetic Resonance (LF-NMR) and surface nuclear magnetic resonance applications, i.e., in the frequency range of kHz, high sensitivity magnetic field detectors are needed. Usually, low-T{sub c} superconducting quantum interference devices (SQUIDs) with a high field sensitivity of about 1 fT/Hz{sup 1/2} are employed as detectors. Considering the flux trapping and operational difficulties associated with low-T{sub c} SQUIDs, we designed and fabricated liquid-nitrogen-cooled Cu coils for NMR detection in the kHz range. A cooled coil system consisting of a 9-cm diameter Cu coil and a low noise preamplifier was systematically investigated and reached a sensitivity of 2 fT/Hz{sup 1/2} at 77 K, which is 3 times better compared to the sensitivity at 300 K. A Q-switch circuit as an essential element for damping the ringing effects of the pickup coil was developed to acquire free induction decay signals of a water sample with minimum loss of signal. Our studies demonstrate that cooled Cu coils, if designed properly, can provide a comparable sensitivity to low-T{sub c} SQUIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging

Pulse-induced transients such as eddy currents can cause problems in measurement techniques where a signal is acquired after an applied preparatory pulse. In ultra-low-field magnetic resonance imaging, performed in magnetic fields typically of the order of 100 μT, the signal-to-noise ratio is enhanced in part by prepolarizing the proton spins with a pulse of much larger magnetic field and in part by detecting the signal with a Superconducting QUantum Interference Device (SQUID). The pulse turn-off, however, can induce large eddy currents in the shielded room, producing an inhomogeneous magnetic-field transient that both seriously distorts the spin dynamics and exceeds the range of the SQUID readout. It is essential to reduce this transient substantially before image acquisition. We introduce dynamical cancellation (DynaCan), a technique in which a precisely designed current waveform is applied to a separate coil during the later part and turn off of the polarizing pulse. This waveform, which bears no resemblance to the polarizing pulse, is designed to drive the eddy currents to zero at the precise moment that the polarizing field becomes zero. We present the theory used to optimize the waveform using a detailed computational model with corrections from measured magnetic-field transients. SQUID-based measurements with DynaCan demonstrate a cancellation of 99%. Dynamical cancellation has the great advantage that, for a given system, the cancellation accuracy can be optimized in software. This technique can be applied to both metal and high-permeability alloy shielded rooms, and even to transients other than eddy currents.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Silicon superconducting quantum interference device

We have studied a Superconducting Quantum Interference Device (SQUID) made from a single layer thin film of superconducting silicon. The superconducting layer is obtained by heavily doping a silicon wafer with boron atoms using the gas immersion laser doping technique. The SQUID is composed of two nano-bridges (Dayem bridges) in a loop and shows magnetic flux modulation at low temperature and low magnetic field. The overall behavior shows very good agreement with numerical simulations based on the Ginzburg-Landau equations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

One-step implementation of the 1->3 orbital state quantum cloning machine via quantum Zeno dynamics

We present an approach for implementation of a 1->3 orbital state quantum cloning machine based on the quantum Zeno dynamics via manipulating three rf superconducting quantum interference device (SQUID) qubits to resonantly interact with a superconducting cavity assisted by classical fields. Through appropriate modulation of the coupling constants between rf SQUIDs and classical fields, the quantum cloning machine can be realized within one step. We also discuss the effects of decoherence such as spontaneous emission and the loss of cavity in virtue of master equation. The numerical simulation result reveals that the quantum cloning machine is especially robust against the cavity decay, since all qubits evolve in the decoherence-free subspace with respect to cavity decay due to the quantum Zeno dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entanglement generation of nitrogen-vacancy centers via coupling to nanometer-sized resonators and a superconducting interference device

We present a potential scheme to entangle negatively charged nitrogen-vacancy (N-V) centers in distance using nanomechanical resonators (NAMRs) and a common superconducting quantum interference device (SQUID). By virtually exciting the vibrational modes of the NAMRs, we show the effective coupling between the N-V centers and the SQUID, which is a promising step toward large-sized quantum-information processing with separate N-V centers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum logical gates with four-level superconducting quantum interference devices coupled to a superconducting resonator

We propose a way for realizing a two-qubit controlled phase gate with superconducting quantum interference devices (SQUIDs) coupled to a superconducting resonator. In this proposal, the two lowest levels of each SQUID serve as the logical states and two intermediate levels of each SQUID are used for the gate realization. We show that neither adjustment of SQUID level spacings during the gate operation nor uniformity in SQUID parameters is required by this proposal. In addition, this proposal does not require the adiabatic passage or a second-order detuning and thus the gate is much faster.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗