Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Success Path Method: Introduction to the Success Path Method Software Tool©

As part of its commitment to advancing safety and reliability assessment methodologies, Argonne National Laboratory pioneered the use of an evaluation method called the Success Path Method (SPM) to improve risk management for offshore oil and gas operations. The development of the SPM at Argonne has been driven by the need to improve existing risk assessment methodologies by focusing on the steps necessary for success rather than failure modes alone. This is particularly important for industrial environments like offshore facilities that perform multiple functions under a continuously evolving set of operational conditions – such as water depth and temperature, currents, and weather conditions. In these dynamic environments, the traditional Probabilistic Risk Assessment (PRA) approach is far too complex as it focuses on what can go wrong – which comprises an infinite failure space that must be fully explored and understood. By shifting the focus to a finite space of success paths, the SPM enables operators and decision makers to prioritize a manageable number of steps that must go right to ensure success. Building on its five decades of experience in safety assessments for the nuclear industry, Argonne made major adaptations to existing risk assessment methods utilizing features similar to fault trees that are traditionally used in PRA to map all pathways in which the system can malfunction. In contrast, SPM identifies the components and processes that must function correctly to achieve specific outcomes – such as preventing the uncontrolled release of hydrocarbons during drilling operations. The SPM framework integrates equipment, procedures, software, processes, and human actions to ensure that physical barriers meet critical safety functions in dynamic operational conditions. This approach helps identify failure modes and improve operational risk management by narrowing the focus to key success elements, which in turn reduces uncertainty and helps users understand, manage, and respond to failures.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the Applicability of Solar and Lamp Radiometric Calibrations of a Precision Sun Photometer Operating Between 300 and 1025 nm

Over a period of 3 year a precision Sun photometer (SPM) operating between 300 and 1025 nm was calibrated four times at three different high-mountain sites in Switzerland, Germany, and the United States by means of the Langley-plot technique. We found that for atmospheric window wavelengths the total error (2 sigma-statistical plus systematic errors) of the calibration constants V(sub 0)(lambda), the SPM voltage in the absence of any attenuating atmosphere, can be kept below 1.60% in the UV-A and blue, 0.9% in the mid-visible, and 0.6% in the near-infra red spectral region. For SPM channels within strong water-vapor or ozone absorption bands a modified Langley-plot technique was used to determine V(sub 0)(lambda) with a lower accuracy. Within the same period of time, we calibrated the SPM five times using irradiance standard lamps in the optical labs of the Physikalisch-Meteorologisches Observatorium Davos and World Radiation Center, Switzerland, and of the Remote Sensing Group of the Optical Sciences Center, University of Arizona, Tucson, Arizona. The lab calibration method requires knowledge of the extraterrestrial spectral irradiance. When we refer the standard lamp results to the World Radiation Center extraterrestrial solar irradiance spectrum, they agree with the Langley results within 2% at 6 or 13 SPM wavelengths. The largest disagreement (4.4%) is found for the channel centered at 610 nm. The results of these intercomparisons change significantly when the lamp results are referred to two different extraterrestrial solar irradiance spectra that have become recently available.

Schmid, Beat↗

Perspectives in Scanning Probe Microscopy from the 2021 Joint International Scanning Probe Microscopy and Scanning Probe Microscopy on Soft and Polymeric Materials Conference

In March of 2020 we were well on our way to organizing and hosting one of the premier scanning probe microscopy (SPM) conferences in Breckenridge, Colorado, USA. For the first time, the meeting would synergistically combine International Scanning Probe Microscopy (ISPM) and Scanning Probe Microscopy on Soft and Polymeric Materials (SPMonSPM), to increase the breadth of audience expertise and experience. We coined the joint conference iSPM 3 – a moniker we hope will persist in future events. The plan for 2020 iSPM 3 screeched to a halt in mid-March, amidst the COVID-19 pandemic. Luckily, we were able to regroup and reimagine the conference for 2021 as a virtual experience. The conference took place June 28th to July 2nd with a mix of live and pre-recorded content. Spread throughout the week were 4 live panel discussions, 3 plenary talks, 23 invited talks, 75 contributed talks, 15 posters and 3 social events. The technical program represented much of the latest and most impactful research in the field. The panel discussions sought to step back from specific research findings and assess the state of SPM as it pertains to some of the most pressing opportunities and influential successes. The lively discussions painted a vibrant future for SPM in both breadth and detail, and we hope that similar discussion can be a mainstay of future SPM conferences. In this work, we attempt to distill some of that discussion to motivate researchers across the field of SPM in the coming years.

47 OTHER INSTRUMENTATION↗

Enhancing Lithium-Ion Battery Aging Simulations: Coupling a High-Resolution, 3D, Grain-Scale Electromechanical Model to a Single-Particle Model

One of the main goals in modeling lithium-ion batteries is to improve/predict longevity and resilience of new chemistries. Unfortunately, this requires simulation of thousands of charge/discharge cycles, which can be rather time consuming depending on the fidelity of the simulation. The purpose of this talk is to discuss a new modeling framework that couples a high-resolution, continuous damage model (CDM) to a single particle model (SPM) resulting in a good combination of speed and fidelity. In previous work, a 3D, continuum-level chemo-mechanical model was developed to investigate cracking within a single cathode particle comprised of hundreds to thousands of randomly oriented grains. The CDM predicted that particle fracture is primarily due to non-ideal grain interactions with slight dependence on high-rate charge demands. Essentially, when neighboring grains were misaligned, they expanded different rates relative to one another leading to high stresses and ultimately the formation of intraparticle cracks. The model predicted that small particles with large grains develop significantly less damage than larger particles with small grains. Finally, the model predicted most of the chemo-mechanical damage accumulates in the first charge after formation. This chemo-mechanical "damage saturation" effect indicated that initial particle fracture occurs within the first few cycles, while long-term cathode degradation is not solely chemo-mechanically induced. This led to a need for simulating fatigue-like mechanism that degrade the battery over longer time scales. In order to reach the time scales, need to resolve fatigue-like degradation, the CDM needs to be complemented by a faster model. Therefore, recent efforts have been focused on using results from the CDM to inform parameters within the SPM. These parameters are homogenization factors that are associated with diffusion, particle radius, and/or exchange current density. By coupling the CDM to the SPM, the aging simulation is broken up into two domains: short-term and long-term degradation. The short-term degradation occurs over a single cycle and is handled by the CDM due of its high fidelity, but relatively expensive computational cost. Such mechanism include break-in crack caused by mismatches in grain orientation. The long-term degradation occurs over tens of cycles and is handled by the SPM due it's computational efficiency. Most of the fatigue-like mechanism fall into this category. The eventual goal of this modeling framework is to upscale to a psudo-2D model allowing for full electrode simulation, which are informed by high-fidelity grain-scale simulations.

electrochemistry↗

Comparison of Total Solar Irradiance with NASA/NSO Spectromagnetograph Data in Solar Cycles 22 and 23

An earlier study compared NASA/NSO Spectromagnetograph (SPM) data with spacecraft measurements of total solar irradiance (TSI) variations over a 1.5 year period in the declining phase of solar cycle 22. This paper extends the analysis to an eight-year period which also spans the rising and early maximum phases of cycle 23. The conclusions of the earlier work appear to be robust: three factors (sunspots, strong unipolar regions, and strong mixed polarity regions) describe most of the variation in the SPM record, but only the first two are associated with TSI. Additionally, the residuals of a linear multiple regression of TSI against SPM observations over the entire eight-year period show an unexplained, increasing, linear time variation with a rate of about 0.05 W m(exp -2) per year. Separate regressions for the periods before and after 1996 January 01 show no unexplained trends but differ substantially in regression parameters. This behavior may reflect a solar source of TSI variations beyond sunspots and faculae but more plausibly results from uncompensated non-solar effects in one or both of the TSI and SPM data sets.

Jones, Harrison P.↗

A Singular Perturbation Approach for Time-Domain Assessment of Phase Margin

This paper considers the problem of time-domain assessment of the Phase Margin (PM) of a Single Input Single Output (SISO) Linear Time-Invariant (LTI) system using a singular perturbation approach, where a SISO LTI fast loop system, whose phase lag increases monotonically with frequency, is introduced into the loop as a singular perturbation with a singular perturbation (time-scale separation) parameter Epsilon. First, a bijective relationship between the Singular Perturbation Margin (SPM) max and the PM of the nominal (slow) system is established with an approximation error on the order of Epsilon(exp 2). In proving this result, relationships between the singular perturbation parameter Epsilon, PM of the perturbed system, PM and SPM of the nominal system, and the (monotonically increasing) phase of the fast system are also revealed. These results make it possible to assess the PM of the nominal system in the time-domain for SISO LTI systems using the SPM with a standardized testing system called "PM-gauge," as demonstrated by examples. PM is a widely used stability margin for LTI control system design and certification. Unfortunately, it is not applicable to Linear Time-Varying (LTV) and Nonlinear Time-Varying (NLTV) systems. The approach developed here can be used to establish a theoretical as well as practical metric of stability margin for LTV and NLTV systems using a standardized SPM that is backward compatible with PM.

Zhu, J. Jim↗

Metal (Fe, Cu, and As) transformation and association within secondary minerals in neutralized acid mine drainage characterized using X-ray absorption spectroscopy

The formation and transformation of secondary minerals in areas affected by neutralized acid mine drainage (AMD) determine the behavior of toxic elements. To better understand the binding form of toxic elements in the secondary minerals, we focused on the distribution of secondary precipitates and heavy metals in neutralized AMD near a typical Cu-polymetallic deposit located in central Tibet. Compared to background values, the average heavy metal (As, Cu, Co, Cu, Mo, Pb, and Zn) content is higher in sediments close to the neutralized AMD drain. X-ray absorption spectroscopy (XAS) characterization shows the Fe in the suspended particulate matter (SPM) first aggregate as small Fe(III) octahedra clusters and then precipitate as ferrihydrite along the river. The XAS results also show the by-products of neutralization-ferrihydrite and sulfate-are the primary forms of Fe and S in the sediments, respectively. Gypsum retains Cu in the sediments via structural fixation, surface adsorption, and surface coprecipitation. The difference of Cu-O coordination number between the SPM and the sediments reveals the Cu sulfate coprecipitation on the surface of gypsum accompanied by SPM transporting along the river. XAS results confirm that ferrihydrite act as an essential sink for heavy metals, especially As. As (III) mineral in the sediment near the neutralized AMD outfall is dissolved and oxidized to arsenate downstream, which then adsorb to ferrihydrite and/or form As(V)-Fe minerals along the river. Gypsum and ferrihydrite have the potential to release heavy metals with changes in water chemistry, which may pose a threat to the safety of drinking water for downstream residents. These results deepen the understanding of the influence of secondary minerals (especially gypsum and ferrihydrite) on the migration and transformation process of heavy metal pollutants in mine drainage system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PINN surrogate of Li-ion battery models for parameter inference, Part I: Implementation and multi-fidelity hierarchies for the single-particle model

To plan and optimize energy storage demands that account for Li-ion battery aging dynamics, techniques need to be developed to diagnose battery internal states accurately and rapidly. Here, this study seeks to reduce the computational resources needed to determine a battery's internal states by replacing physics-based Li-ion battery models - such as the single-particle model (SPM) and the pseudo-2D (P2D) model - with a physics-informed neural network (PINN) surrogate. The surrogate model makes high-throughput techniques, such as Bayesian calibration, tractable to determine battery internal parameters from voltage responses. This manuscript is the first of a two-part series that introduces PINN surrogates of Li-ion battery models for parameter inference (i.e., state-of-health diagnostics). In this first part, a method is presented for constructing a PINN surrogate of the SPM. A multi-fidelity hierarchical training, where several neural nets are trained with multiple physics-loss fidelities is shown to significantly improve the surrogate accuracy when only training on the governing equation residuals. The implementation is made available in a companion repository (https://github.com/NREL/PINNSTRIPES). The techniques used to develop a PINN surrogate of the SPM are extended in Part II for the PINN surrogate for the P2D battery model, and explore the Bayesian calibration capabilities of both surrogates.

25 ENERGY STORAGE↗

PINN surrogate of Li-ion battery models for parameter inference, Part II: Regularization and application of the pseudo-2D model

Bayesian parameter inference is useful to improve Li-ion battery diagnostics and can help formulate battery aging models. However, it is computationally intensive and cannot be easily repeated for multiple cycles, multiple operating conditions, or multiple replicate cells. To reduce the computational cost of Bayesian calibration, numerical solvers for physics-based models can be replaced with faster surrogates. A physics-informed neural network (PINN) is developed as a surrogate for the pseudo-2D (P2D) battery model calibration. For the P2D surrogate, additional training regularization was needed as compared to the PINN single-particle model (SPM) developed in Part I. Both the PINN SPM and P2D surrogate models are exercised for parameter inference and compared to data obtained from a direct numerical solution of the governing equations. A parameter inference study highlights the ability to use these PINNs to calibrate scaling parameters for the cathode Li diffusion and the anode exchange current density. By realizing computational speed-ups of ~2250x for the P2D model, as compared to using standard integrating methods, the PINN surrogates enable rapid state-of-health diagnostics. Finally, in the low-data availability scenario, the testing error was estimated to ~2 mV for the SPM surrogate and ~10 mV for the P2D surrogate which could be mitigated with additional data.

25 ENERGY STORAGE↗

Bayesian inference in band excitation scanning probe microscopy for optimal dynamic model selection in imaging

The universal tendency in scanning probe microscopy (SPM) over the last two decades is to transition from simple 2D imaging to complex detection and spectroscopic imaging modes. The emergence of complex SPM engines brings forth the challenge of reliable data interpretation, i.e., conversion from detected signals to descriptors specific to tip–surface interactions and subsequently to material’s properties. In this work, we implemented a Bayesian inference approach for the analysis of the image formation mechanisms in band excitation SPM. Compared to the point estimates in classical functional fit approaches, Bayesian inference allows for the incorporation of extant knowledge of materials and probe behavior in the form of corresponding prior distribution and return the information on the material functionality in the form of readily interpretable posterior distributions. We explore the nonlinear mechanical behaviors spatially in a classical ferroelectric material, PbTiO 3 . We observe the non-trivial evolution of the Duffing stiffness term and the nonlinearity of the sample surface, determine spatial clustering of the nonlinear response, and perform a Landau analysis on predicting the nonlinear coefficient, which indicates that ferroelectric behavior can be a cause of the observed results. These observations suggest that the spectrum of anomalous behaviors at the ferroelectric domain walls may be broader than previously believed and can extend to non-conventional mechanical properties in addition to static and microwave conductance.

36 MATERIALS SCIENCE↗

Exploring leakage in dielectric films via automated experiments in scanning probe microscopy

Here electronic conduction pathways in dielectric thin films are explored using automated experiments in scanning probe microscopy (SPM). In this study, we use large field of view scanning to identify the position of localized conductive spots and develop an SPM workflow to probe their dynamic behavior at higher spatial resolution as a function of time, voltage, and scanning process in an automated fashion. Using this approach, we observe the variable behaviors of the conductive spots in a 20-nm-thick ferroelectric Hf 0.54 Zr 0.48 O 2 film, where conductive spots disappear and reappear during continuous scanning. There are also fresh conductive spots that develop during scanning. The automated workflow is universal and can be integrated into a wide range of microscopy techniques, including SPM, electron microscopy, optical microscopy, and chemical imaging.

36 MATERIALS SCIENCE↗

Automated scanning probe microscopy of combinatorial ferroelectric libraries: Gaussian-process-guided exploration and noise-aware experiment planning

Combinatorial materials libraries provide an efficient route for mapping composition–property relationships, but their broader impact depends on rapid, quantitative, and functionally relevant characterization. Scanning Probe Microscopy (SPM), including piezoresponse force microscopy (PFM), offers significant potential for quantitative, functionally relevant combi-library readouts. Here, we implement a fully automated SPM workflow for ferroelectric combinatorial libraries and benchmark Gaussian-process-based Bayesian optimization strategies for autonomous experiment planning. The workflow integrates automated probe motion, contact optimization, imaging, and dual amplitude resonance tracking-PFM spectroscopy, and uses scalarized spectroscopic observables to guide subsequent measurements. Stage motion, probe engagement, in-contact tuning, imaging, spectroscopy, and the choice of the next measurement location all proceed without human input. We demonstrate the approach on Sm-doped BiFeO 3 and Zn x Mg 1−x O libraries. By comparing vanilla Bayesian optimization with a measured-noise variant, we show that explicit treatment of local reproducibility can improve modeling of composition-dependent response when the measured variance is physically meaningful, but can also reduce robustness when variability is dominated by outliers or topographic artifacts. Furthermore, these results establish automated SPM as a bridge between combinatorial synthesis and quantitative functional characterization.

Liu, Yu [University of Tennessee, Knoxville, TN (U↗

Imaging the flow of holes from a collimating contact in graphene

A beam of holes formed in graphene by a collimating contact is imaged using a liquid-He cooled scanning probe microscope (SPM). The mean free path of holes is greater than the device dimensions. A zigzag shaped pattern on both sides of the collimating contact absorbs holes that enter at large angles. The image charge beneath the SPM tip defects holes, and the pattern of flow is imaged by displaying the change in conductance between contacts on opposite sides, as the tip is raster scanned across the sample. Collimation is confirmed by bending hole trajectories away from the receiving contact with an applied magnetic field. The SPM images agree well with ray-tracing simulations.

36 MATERIALS SCIENCE↗

Design of a 100 kW Surface Permanent Magnet Machine with Wide Constant Power Speed Ratio for Traction Applications

Surface permanent magnet (SPM) machines are considered to be strong candidates for traction applications due to their high power density and high efficiency. By adopting fractional-slot concentrated windings, SPM machines can achieve a wide constant power speed range. A carbon fiber sleeve is applied to ensure the retainment of the magnets at high speed operating conditions. The purpose of this paper is to present the design of a high speed SPM machine for traction applications with 25 kW/Liter active power density and a wide constant-power speed range that is consistent with guidelines and targets presented in the Electrical and Electronics Technical Team Roadmap published by the US Department of Energy. The predicted electromagnetic performance and structural characteristics are presented based on both analytical and FEA results.

42 ENGINEERING↗

Signal Differentiation of Moving Magnetic Nanoparticles for Enhanced Biodetection and Diagnostics

Magnetic nanoparticles are extensively utilized as markers/signal labelling in various biomedical applications. Detecting and distinguishing magnetic signals from similarly sized moving magnetic nanoparticles in microfluidic systems is crucial yet challenging for biosensing. In this study, we have developed an original method to detect and differentiate magnetic signals from moving superparamagnetic (SPM) and ferrimagnetic (FM) nanoparticles of comparable sizes. Our approach utilizes a highly sensitive magnetic-coil-based sensor that harnesses the combined effects of giant magnetoimpedance (GMI) and an LC-resonance circuit, offering performance superior to that of conventional GMI sensors. Iron oxide nanoparticles, which have similar particle sizes but differing coercivities (zero for SPM and non-zero for FM) or similar zero coercivities but differing particle sizes, flow through the magnetic coil at controlled velocities. Their distinct effects are analyzed through changes in the complex impedance of the sensing system. Our findings provide a unique pathway for utilizing SPM and FM nanoparticles as innovative magnetic markers to identify specific biological entities, thereby expanding their potential applications.

Hwang, Kee Young↗

Beta systems error analysis

The atmospheric backscatter coefficient, beta, measured with an airborne CO Laser Doppler Velocimeter (LDV) system operating in a continuous wave, focussed model is discussed. The Single Particle Mode (SPM) algorithm, was developed from concept through analysis of an extensive amount of data obtained with the system on board a NASA aircraft. The SPM algorithm is intended to be employed in situations where one particle at a time appears in the sensitive volume of the LDV. In addition to giving the backscatter coefficient, the SPM algorithm also produces as intermediate results the aerosol density and the aerosol backscatter cross section distribution. A second method, which measures only the atmospheric backscatter coefficient, is called the Volume Mode (VM) and was simultaneously employed. The results of these two methods differed by slightly less than an order of magnitude. The measurement uncertainties or other errors in the results of the two methods are examined.

Source record↗

Airborne particulate matter and spacecraft internal environments

Instrumentation, consisting of a Shuttle Particle Sampler (SPS) and a Shuttle Particle Monitor (SPM), has been developed to characterize the airborne particulate matter in the Space Shuttle cabin during orbital flight. The SPS size selectively collects particles in four size fractions (0-2.5, 2.5-10, 10-100, and greater than 100 microns) which are analyzed postflight for mass concentration and size distribution, elemental composition, and morphology. The SPM provides a continuous record of particle concentration through photometric light scattering. Measurements were performed onboard Columbia, OV-102, during the flight of STS-32 in January 1990. No significant changes were observed in the particle mass concentration, size distribution, or chemical composition in samples collected during flight-day 2 and flight-day 7. The total mass concentration was 56 microg/cu cm with approximately half of the particles larger than 100 microns. Elemental analysis showed that roughly 70 percent of the particles larger than 2.5 microns were carbonaceous with small amounts of other elements present. The SPM showed no temporal or spatial variation in particle mass concentration during the mission.

Liu, Benjamin Y. H.↗

Carbon Nanotube Based Nano-Electro-Mechanical Systems (NEMS)

Carbon nanotubes (CNT) enable nanoelectromechanical systems (NEMS) because of their inherent nanostructure, intrinsic electric conductivity and mechanical resilience. The collaborative work between Stanford (experiment) and NASA Ames (theory and simulation) has made progress in two types of CNT based NEMS for nanoelectronics and sensor applications. The CNT tipped scanning probe microscopy (SPM) is a NEMS in which CNT tips are used for nanoscale probing, imaging and manipulating. It showed great improvement in probing surfaces and biological systems over conventional tips. We have recently applied it to write (lithography) and read (image) uniform SiO2 lines on large Si surface area at speed up to 0.5 mm per s. Preliminary work using approximately 10 nm multiwall nanotube tips produced approximately 10 nm structures and showed that the CNT tips didn't wear down when crashed as conventional tips often do. This presents a solution to the long standing tip-wear problem in SPM nanolithography. We have also explored potential of CNT tips in imaging DNA in water. Preliminary experiment using 10 nm CNT tips reached 5 nm resolution. The 1 nm nanolithography and 1 nm DNA imaging can be expected by using approximately 1 nm CNT tips. In contrast to CNT tipped SPM, we also fabricated CNT devices on silicon wafer in which CNTs connect patterned metallic lines on SiO2/Si by a simple chemical vapor deposition process. Using conventional lithography for silicon wafer, we have been able to obtain CNT based transistors and sensors. Investigations of the CNT NEMS as physical, biological and chemical sensors are in progress and will be discussed.

Han, Jie↗