Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SNR IMPROVEMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Landsat Data Continuity Mission

The Landsat Data Continuity Mission (LDCM) is currently under development and is on schedule to launch the 8th satellite in the Landsat series in December of 2012. LDCM is a joint project between the National Aeronautics and Space Administration (NASA) and the United States Geological Survey (USGS). NASA is responsible for developing and launching the flight hardware and on-orbit commissioning and USGS is responsible for developing the ground system and operating the system onorbit after commissioning. Key components of the flight hardware are the Operational Land Imager (OLI), nearing completion by Ball Aerospace & Technologies Corp in Boulder, CO, the Thermal Infrared Sensor (TIRS), being built by NASA's Goddard Space Flight Center and the spacecraft, undergoing integration at Orbital Sciences Corp in Gilbert, Arizona. The launch vehicle will be an Atlas-5 with launch services provided by NASA's Kennedy Space Center. Key ground systems elements are the Mission Operations Element, being developed by the Hammers Corporation, and the Collection Activity Planning Element, Ground Network Element, and Data Processing and Archive System, being developed internally by the USGS Earth Resources Observations and Science (EROS) Center. The primary measurement goal of LDCM is to continue the global coverage of moderate spatial resolution imagery providing continuity with the existing Landsat record. The science goal for this imagery is to monitor land use and land cover, particularly as it relates to global climate change. Together the OLI and TIRS instruments on LDCM replace the ETM+ instrument on Landsat-7 with significant enhancements. The OLI is a pushbroom design instrument where the scanning mechanism of the ETM+ is effectively replaced by a long line of detectors. The OLI has 9 spectral bands with similar spatial resolution to ETM+: 7 of them similar to the reflective spectral bands on ETM+ and two new bands. The two new bands cover (1) the shorter wavelength blue part of the spectrum to help with coastal studies and aerosol analyses/atmospheric correction and (2) an atmospheric water absorption band, where the Earth surface is generally not visible, but Cirrus clouds are, to aid in cloud detection and screening. The radiometry of OLI benefits from improved SNR, dynamic range and quantization. OLI is undergoing system testing with a delivery scheduled for Spring 2011. The TIRS is also a pushbroom design and used QWIPS detectors that require cooling to 43K using a cryocooler. It.has two spectral bands, effectively splitting the ETM+ band 6 in half, that can be used as a split window to aid in atmospheric correction. It has nominally 100 m spatial resolution as opposed to the 60 m of Landsat-7 ETM+: TIRS has commenced integration and test, with a delivery to the spacecraft vendor scheduled for Winter 2011-2012. The Orbital spacecraft currently being integrated for LDCM will have improved capabilities for pointing over previous missions. These capabilities will allow the OLI and TIRS instruments to point off-nadir the equivalent of one WRS-2 path to increase the chances of coverage for high priority targets, particularly in the event of natural disasters. Also, the pointing capability will allow the calibration of the OLI using the sun (roughly weekly), the moon (monthly), stars (during commissioning) and the Earth (at 90 deg from normal orientation, a.k.a., side slither) quarterly. The solar calibration will be used for OLI absolute and relative calibration, the moon for trending the stability of the OLI response, the stars will be used for Line of Sight determination and the side slither will be an alternate OLI and relative gain determination methodology. The spacecraft is scheduled to begin integration with the OLI instrument in Summer 2011. The LDCM data processing and archive system (DPAS), located at USGS EROS, generates the products for distribution to users. Like Landsat-7 this includes an image assessment system for characrizing instrument performance and updating calibration parameters. Products will be generated that include the spectral bands from both instruments, terrain corrected and registered to the geoid. Also, like Landsat-7, data products will be distributed at no charge to the user. The current status and plans of the space and ground segments of the LDCM project will be presented along with performance predictions as available. More detailed information on the two instruments is intended to be presented in separate papers.

Markham, Brian↗

Convergent laser beam shapes: Unveiling the dynamics of Laser-induced elastic waves in composite materials

Overcoming the low signal-to-noise ratio (SNR) in laser ultrasonic testing of composite materials remains a significant challenge. Current efforts focus on enhancing SNR by inserting more energy into the material through temporal and/or spatial modulation of the laser beam. However, potential SNR improvements through wave convergence and wave energy manipulation have been overlooked. This paper addresses this gap by demonstrating the convergence of different wave types to a designated point and by showing the feasibility of directing absorbed laser energy into a specific wave type through spatial modulation of the laser beam. To achieve this, mathematical expressions for the convergent laser beams are derived. Various laser beam profiles are then introduced to the thermoelastic equations and solved using the finite element method. The sample under investigation is a transversely isotropic unidirectional carbon fiber reinforced plastic, characterized by anisotropic thermal expansion coefficients and thermal conductivities. Results reveal pronounced convergence of the intended wave type at the center due to laser beam shaping. This study showcases the ability to direct absorbed laser energy toward a specific wave type through spatial modulation of the laser beam and highlights the role of material anisotropy in energy focusing.

composite materials↗

SU-C-201-03: Coded Aperture Gamma-Ray Imaging Using Pixelated Semiconductor Detectors

Purpose: Improved localization of gamma-ray emissions from radiotracers is essential to the progress of nuclear medicine. Polaris is a portable, room-temperature operated gamma-ray imaging spectrometer composed of two 3×3 arrays of thick CdZnTe (CZT) detectors, which detect gammas between 30keV and 3MeV with energy resolution of <1% FWHM at 662keV. Compton imaging is used to map out source distributions in 4-pi space; however, is only effective above 300keV where Compton scatter is dominant. This work extends imaging to photoelectric energies (<300keV) using coded aperture imaging (CAI), which is essential for localization of Tc-99m (140keV). Methods: CAI, similar to the pinhole camera, relies on an attenuating mask, with open/closed elements, placed between the source and position-sensitive detectors. Partial attenuation of the source results in a “shadow” or count distribution that closely matches a portion of the mask pattern. Ideally, each source direction corresponds to a unique count distribution. Using backprojection reconstruction, the source direction is determined within the field of view. The knowledge of 3D position of interaction results in improved image quality. Results: Using a single array of detectors, a coded aperture mask, and multiple Co-57 (122keV) point sources, image reconstruction is performed in real-time, on an event-by-event basis, resulting in images with an angular resolution of ∼6 degrees. Although material nonuniformities contribute to image degradation, the superposition of images from individual detectors results in improved SNR. CAI was integrated with Compton imaging for a seamless transition between energy regimes. Conclusion: For the first time, CAI has been applied to thick, 3D position sensitive CZT detectors. Real-time, combined CAI and Compton imaging is performed using two 3×3 detector arrays, resulting in a source distribution in space. This system has been commercialized by H3D, Inc. and is being acquired for various applications worldwide, including proton therapy imaging R&D.

60 APPLIED LIFE SCIENCES↗

SU-F-J-41: Experimental Validation of a Cascaded Linear System Model for MVCBCT with a Multi-Layer EPID

Purpose: The purpose of this study was to validate the use of a cascaded linear system model for MV cone-beam CT (CBCT) using a multi-layer (MLI) electronic portal imaging device (EPID) and provide experimental insight into image formation. A validated 3D model provides insight into salient factors affecting reconstructed image quality, allowing potential for optimizing detector design for CBCT applications. Methods: A cascaded linear system model was developed to investigate the potential improvement in reconstructed image quality for MV CBCT using an MLI EPID. Inputs to the three-dimensional (3D) model include projection space MTF and NPS. Experimental validation was performed on a prototype MLI detector installed on the portal imaging arm of a Varian TrueBeam radiotherapy system. CBCT scans of up to 898 projections over 360 degrees were acquired at exposures of 16 and 64 MU. Image volumes were reconstructed using a Feldkamp-type (FDK) filtered backprojection (FBP) algorithm. Flat field images and scans of a Catphan model 604 phantom were acquired. The effect of 2×2 and 4×4 detector binning was also examined. Results: Using projection flat fields as an input, examination of the modeled and measured NPS in the axial plane exhibits good agreement. Binning projection images was shown to improve axial slice SDNR by a factor of approximately 1.4. This improvement is largely driven by a decrease in image noise of roughly 20%. However, this effect is accompanied by a subsequent loss in image resolution. Conclusion: The measured axial NPS shows good agreement with the theoretical calculation using a linear system model. Binning of projection images improves SNR of large objects on the Catphan phantom by decreasing noise. Specific imaging tasks will dictate the implementation image binning to two-dimensional projection images. The project was partially supported by a grant from Varian Medical Systems, Inc. and grant No. R01CA188446-01 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Report to Lincoln Labs on TWPAs

This past spring LLNL’s Quantum Sensor’s team received two TWPA amplifiers from Lincoln Labs along with a data-sheet explaining handling, operations and expected performance. Here we will outline some of the initial tests performed on this amplifiers as part of LLNL’s Quantum Sensors Strategic Initiative (QSSI). Initial testing confirmed that both amplifiers worked and provided gain and SNR improvement similar to that called out in the data-sheets provided.

42 ENGINEERING↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

Model Card for WaveDP

WaveDP was trained using both earthquake signals and pure noise waveforms from the Stanford Earthquake Dataset (STEAD). The model achieved a median signal-to-noise ratio (SNR) improvement of 7 dB. Because the model uses seismograms as direct input, the model is four times faster than an existing model for signal denoising that uses spectral representations of seismograms as input.

47 OTHER INSTRUMENTATION↗

Delta modulation

The results are presented of a study dealing with the problems of source encoding using delta modulation. An algorithm is described which was employed in the design of an adaptive delta modulation. The algorithm is extremely inexpensive to implement and features extremely desirable characteristics such as a 40 db dynamic range and a 90 percent non-redundant word intelligibility at a bit rate of 9.6 kb/s. A new concept is presented in delta modulation design, the nth-order delta modulator. The nth order delta modulator increases the maximum SNR of a delta modulator but not its dynamic range. It is shown that a 2nd order delta modulator, which employs two delta modulators in cascade, results in a 15 db output SNR improvement over a linear delta modulator operating at 27 db. Two additional areas of research are discussed. The first area involves decomposition of voice and the second is concerned with the source encoding of video signals.

Schilling, D. L.↗

A superconducting time-variant filtering system.

Description of a laboratory test facility for studying the tracking capabilities of a superconducting time-varying filter system. An RF signal from an antenna is amplified and fed to a mixer; the IF signal modulates an optical diode, and the emitted light is directed through an optical system onto a high-purity high-resistance semiconductor terminating a quarter-wavelength stub in a lead-plated superconducting cavity. The resulting perturbation in the cavity resonant frequency is proportional to the signal modulation present in the light beam. The narrow-band superconducting cavity is thereby acting as a time-variant filter that tracks the instantaneous signal modulation. SNR improvement on the order of 25 dB can be obtained due to the noise rejection characteristics of such a modulation tracking filter.

Arndt, G. D.↗

Diffuse-direct ultraviolet ratios with a compact double monochromator

An improved system has been implemented for measuring the ratio of the diffuse skylight to the direct sunlight in the biologically active region of the UV near the atmospheric limit. It combines a double monochromator employing holographic gratings for reduction of stray light with a cooled photomultiplier tube to provide a greatly improved SNR below 300 nm. Data may be obtained in either a scan mode or a narrowband photometry mode; in the latter mode accurate ratios have been obtained near 290 nm. Representative data are discussed along with a theoretical model of the ratio. The system is compact enough for use in a mobile monitoring system.

Garrison, L. M.↗

Performance analysis of the DSN baseband assembly (Bba) Real-Time Combiner (RTC)

The operation of the BBA Real Time Combiner (RTC) is discussed and its performance investigated in detail. It is shown that each channel of the RTC can be modelled by a simple block diagram in the z-transform domain from which all pertinent transient and steady state behavioral characteristics can be determined. In particular, the characteristic equation of the tracking loop and its equivalent noise bandwidth are found and used to evaluate the closed loop transient response and steady-state mean squared timing jitter. The impact of the totality of these loop jitter contributions on the combiner output SNR is evaluated and illustrated numerically. These results show that for parameters of interest to various space missions, the RTC is capable of providing significant SNR improvement relative to a single receiving antenna.

Simon, M. K.↗

Performance analysis of the DSN baseband assembly (Bba) Real-Time Combiner (RTC)

The operation of the BBA Real Time Combiner (RTC) is discussed and its performance investigated in detail. It is shown that each channel of the RTC can be modelled by a simple block diagram in the z-transform domain from which all pertinent transient and steady state behavioral characteristics can be determined. In particular, the characteristic equation of the tracking loop and its equivalent noise bandwidth are found and used to evaluate the closed loop transient response and steady state mean squared timing jitter. The impact of the totality of these loop jitter contributions on the combiner output SNR is evaluated and illustrated numerically. These results show that for parameters of interest to various space missions, the RTC is capable of providing significant SNR improvement relative to a single receiving antenna.

Simon, M. K.↗

Increased sensitivity of a vidicon optical multichannel analyzer with a detachable electrostatic image intensifier

A substantial gain in sensitivity is reported through the addition of a commercially available electrostatic image intensifier to a silicon-intensified target vidicon system. This comparatively low cost modification allows cooled or room temperature operation, CW or pulsed detection, and ease of removal or attachment. A 40-mm, first-generation technology image intensifier was used in a configuration in which the photocathode end was at negative high voltage and the phosphor end was at ground. Cooling the vidicon detector did not result in improved SNR; more generally, a 50-fold sensitivity increase was observed for the image intensifier/vidicon system.

Snow, J. B.↗

1.3-micron Ku-band fiberoptic transmission system for satellite communications and antenna remoting

Microwave fiberoptic transmission system provides numerous advantages for satellite communications terminals and antenna remoting. This paper described a 1.3-micron, 6-15 GHz, 1-km fiberoptic system design and performance. The microwave characteristics of the laser diode photodetector are discussed in detail. The preliminary measured system signal-to-noise ratio (SNR) are 110-120 dB/Hz in the frequency range of 6-15 GHz. A 20 to 30 dB SNR improvement is achievable when coherent detection and PD impedance matching are employed.

Pan, J. J.↗

Remote sensing science for the Nineties; Proceedings of IGARSS '90 - 10th Annual International Geoscience and Remote Sensing Symposium, University of Maryland, College Park, May 20-24, 1990. Vols. 1, 2, & 3

Various papers on remote sensing (RS) for the nineties are presented. The general topics addressed include: subsurface methods, radar scattering, oceanography, microwave models, atmospheric correction, passive microwave systems, RS in tropical forests, moderate resolution land analysis, SAR geometry and SNR improvement, image analysis, inversion and signal processing for geoscience, surface scattering, rain measurements, sensor calibration, wind measurements, terrestrial ecology, agriculture, geometric registration, subsurface sediment geology, radar modulation mechanisms, radar ocean scattering, SAR calibration, airborne radar systems, water vapor retrieval, forest ecosystem dynamics, land analysis, multisensor data fusion. Also considered are: geologic RS, RS sensor optical measurements, RS of snow, temperature retrieval, vegetation structure, global change, artificial intelligence, SAR processing techniques, geologic RS field experiment, stochastic modeling, topography and Digital Elevation model, SAR ocean waves, spaceborne lidar and optical, sea ice field measurements, millimeter waves, advanced spectroscopy, spatial analysis and data compression, SAR polarimetry techniques. Also discussed are: plant canopy modeling, optical RS techniques, optical and IR oceanography, soil moisture, sea ice back scattering, lightning cloud measurements, spatial textural analysis, SAR systems and techniques, active microwave sensing, lidar and optical, radar scatterometry, RS of estuaries, vegetation modeling, RS systems, EOS/SAR Alaska, applications for developing countries, SAR speckle and texture.

Source record↗