Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SLICING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Impact of Different CT Slice Thickness on Clinical Target Volume for 3D Conformal Radiation Therapy

The purpose of this study was to present the variation of clinical target volume (CTV) with different computed tomography (CT) slice thicknesses and the impact of CT slice thickness on 3-dimensional (3D) conformal radiotherapy treatment planning. Fifty patients with brain tumors were selected and CT scans with 2.5-, 5-, and 10-mm slice thicknesses were performed with non-ionic contrast enhancement. The patients were selected with tumor volume ranging from 2.54 cc to 222 cc. Three-dimensional treatment planning was performed for all three CT datasets. The target coverage and the isocenter shift between the treatment plans for different slice thickness were correlated with the tumor volume. An important observation from our study revealed that for volume < 25 cc, most of the cases were underdosed by 18% with 5-mm slice thickness and 27% with 10-mm slickness. For volume > 25 cc, the target underdosage was less than 6.7% for 5-mm slice thickness and 8% for 10-mm slice thickness. For 3D conformal radiotherapy treatment planning (3DCRT), a CT slice thickness of 2.5 mm is optimum for tumor volume < 25 cc, and 5 mm is optimum for tumor volume > 25 cc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerating Parallel Applications in Cloud Platforms via Adaptive Time-Slice Control

Cloud platforms can provide flexible and cost-effective environments for parallel applications. However, the resource over-commitment issues, i.e., cloud providers often provide much more executable virtual CPUs than available physical CPUs, still impede the synchronization operations of parallel applications, causing severe performance degradation. Existing methods optimize parallel applications by promoting the priorities of involved VMs. They cannot fully explore the performance of parallel applications, because they ignore the time-slice requirements of different phases of parallel applications. Furthermore, non-parallel applications experience unsatisfied performance because of low scheduling priorities. Given empirical analysis on time-slices of virtual machines (VMs), we find that shortening time-slices can mitigate synchronization overhead which incurs during communication phases, while over-short time-slices cause frequent cache misses in computation phases. Accordingly, we propose an Adaptive Time-slice Control (ATC) mechanism. ATC first detects the phases of parallel applications based on lock latency or cache misses. Then, ATC shortens time-slices during communication phases and prolongs time-slices during computation phases for parallel applications, and sets a uniform time-slice for non-parallel applications. Finally, we evaluate ATC using seven well-known benchmarks with 25+ applications. Experiments show that ATC obtains 1.5-75x performance gain for running parallel applications than state-of-the-art solutions, with nearly unaffected impact on non-parallel applications.

97 MATHEMATICS AND COMPUTING↗

Enhancing Security and Resiliency in Operational Technology Environments Through Network Slicing and Federated Learning

The growing convergence of Information Technology (IT) and Operational Technology (OT) within Industry 4.0 environments has introduced new demands on industrial network infrastructure. As cyber-physical systems become increasingly interconnected, ensuring the secure, timely, and efficient exchange of critical data is essential. This thesis explores how network slicing, a method of creating isolated virtual network segments, can be applied within OT environments to address challenges such as latency, security, and resource allocation. The first research question addressed in this thesis is: How can OT networks take advantage of NFV and SDN technology to become cyber resilient? This study examines the operational, security, and architectural implications of introducing network slicing into traditionally static OT infrastructures such as Industrial Control Systems (ICS) and SCADA. Through simulated deployments and case studies, the research demonstrates how slicing enables better isolation between critical and non-critical services, thereby improving response time, throughput, and security in sensitive environments. The second question considers: How to dynamically implement network slicing and take advantage of network resources towards integrating decentralized machine learning? In response, this thesis proposes a framework that combines Software-Defined Networking (SDN), Network Function Virtualization (NFV), and Federated Learning (FL) to enable real-time analytics while maintaining data locality. The proposed approach reduces the burden on centralized infrastructure and minimizes privacy risks by supporting on-site training of models across distributed OT nodes, coordinated through dynamically allocated network slices. The third focus explores: How slicing helps to increase the resiliency of OT networks through the orchestration of a dynamic DMZ? To answer this, the thesis presents a method for creating and managing Dynamic Demilitarized Zones (DMZs) using network slicing. This enables flexible and automated isolation of sensitive subsystems during threat scenarios or high-risk operations. Coupled with intelligent orchestration and containerized security services, the dynamic DMZ significantly enhances the system's ability to respond to cyber incidents without halting production. Ultimately, this thesis contributes a comprehensive architecture that blends network slicing with machine learning, secure segmentation, and automation, paving the way for resilient, adaptive, and intelligent OT environments. Performance evaluations across multiple scenarios show improvements in system reliability, threat response time, model accuracy, and resource utilization, providing a strong foundation for future industrial automation systems.

Rodiles Delgado, Brian G↗

Characteristics and mathematical modeling of apple slice drying in an electrohydrodynamic system with a needle‐plate electrode

Abstract The drying of apple slices in an electrohydrodynamic (EHD) system with a needle‐plate electrode was characterized and mathematically modeled at voltages of 30, 40, and 50 kV and with distances between needles of 5, 6, and 7 cm. The results showed that the drying rate, effective water diffusion coefficient, and rehydration ratio of the apple slices, and specific energy consumption of drying, all increased with increasing voltage. Initially, there was a period when the drying rate was approximately constant in the low‐voltage EHD, but not in the high voltage conditions. At the same voltage, the drying rate was highest when the distance between needles was 6 cm. The voltage and distance between needles had a significant ( p < .05) interactive effect on the effective water diffusion coefficient and specific energy consumption, but not on the rehydration ratio. General mathematical models for drying can be used to represent the drying behavior of apple slices. The Midilli and Kucuk model and the Logarithmic model had the best fits, with correlation coefficients of 0.998803 and 0.998267, respectively. Predictive functions for the moisture ratio of apple slices based on voltage and distance between needles were established and verified. The results indicated that the Logarithmic model could more accurately predict the moisture ratio of apple slices dried using the EHD method. Practical Applications As a new drying technology, electrohydrodynamic (EHD) drying has unequaled advantages. According to the results, using the appropriate voltage and distance between needles improves not only drying efficiency, but also the rehydration ratio of apple slices, which reflects the quality of dried products. The Logarithmic model can accurately predict the EHD drying behavior of apple slices, which is of great significance in optimizing actual production.

Li, Bowen↗

SU-E-I-10: Investigation On Detectability of a Small Target for Different Slice Direction of a Volumetric Cone Beam CT Image

Purpose: To investigate the detectability of a small target for different slice direction of a volumetric cone beam CT image and its impact on dose reduction. Methods: Analytic projection data of a sphere object (1 mm diameter, 0.2/cm attenuation coefficient) were generated and reconstructed by FDK algorithm. In this work, we compared the detectability of the small target from four different backprojection Methods: hanning weighted ramp filter with linear interpolation (RECON 1), hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON 3), and ramp filter with Fourier interpolation (RECON4), respectively. For noise simulation, 200 photons per measurement were used, and the noise only data were reconstructed using FDK algorithm. For each reconstructed volume, axial and coronal slice were extracted and detection-SNR was calculated using channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels. Results: Detection-SNR of coronal images varies for different backprojection methods, while axial images have a similar detection-SNR. Detection-SNR{sup 2} ratios of coronal and axial images in RECON1 and RECON2 are 1.33 and 1.15, implying that the coronal image has a better detectability than axial image. In other words, using coronal slices for the small target detection can reduce the patient dose about 33% and 15% compared to using axial slices in RECON 1 and RECON 2. Conclusion: In this work, we investigated slice direction dependent detectability of a volumetric cone beam CT image. RECON 1 and RECON 2 produced the highest detection-SNR, with better detectability in coronal slices. These results indicate that it is more beneficial to use coronal slice to improve detectability of a small target in a volumetric cone beam CT image. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Program (NIPA-2014-H0201-14-1002) supervised by the NIPA (National IT Industry Promotion Agency). Authors declares that s/he has no conflict of Interest in relation to the work in this abstract.

60 APPLIED LIFE SCIENCES↗

Different CT slice thickness and contrast‐enhancement phase in radiomics models on the differential performance of lung adenocarcinoma

Abstract Background To investigate the effects of computed tomography (CT) reconstruction slice thickness and contrast‐enhancement phase on the differential diagnosis performance of radiomic signature in lung adenocarcinoma. Methods A total of 187 patients who had been pathologically confirmed with lung adenocarcinoma and nonadenocarcinoma were divided into a training cohort ( n = 149) and validation cohort ( n = 38). All the patients underwent contrast‐enhanced CT and the images were reconstructed with different slice thickness. The radiomic features were extracted from different slice thickness and scan phase. The logistic regression (LR) algorithm was used to build a machine learning model for each group. The area under the curve (AUC) obtained from the receiver operating characteristic (ROC) curve and DeLong test was used to evaluate its discriminating performance. Results Finally, 34 image features and five semantic features were selected to establish a radiomics model. Based on the three contrast‐enhanced CT phases and four reconstruction slice thickness, 12 groups of radiomics models showed good discrimination ability with the AUCs range from 0.9287 to 0.9631, sensitivity range from 0.8349 to 0.9083, specificity range from 0.825 to 0.925 in the training group. Similar results were observed in the validation group. However, there was no statistical significance between the different CT scan phase groups and different slice thickness ( p > 0.05). Conclusions The radiomic analysis of contrast‐enhanced CT can be used for the differential diagnosis of lung adenocarcinoma. Moreover, different slice thickness and contrast‐enhanced scan phase did not affect the discriminating ability in the radiomics models.

Wang, Yang↗

TU-A-12A-07: CT-Based Biomarkers to Characterize Lung Lesion: Effects of CT Dose, Slice Thickness and Reconstruction Algorithm Based Upon a Phantom Study

Purpose: Radiogenomics promises the ability to study cancer tumor genotype from the phenotype obtained through radiographic imaging. However, little attention has been paid to the sensitivity of image features, the image-based biomarkers, to imaging acquisition techniques. This study explores the impact of CT dose, slice thickness and reconstruction algorithm on measuring image features using a thorax phantom. Methods: Twentyfour phantom lesions of known volume (1 and 2mm), shape (spherical, elliptical, lobular and spicular) and density (-630, -10 and +100 HU) were scanned on a GE VCT at four doses (25, 50, 100, and 200 mAs). For each scan, six image series were reconstructed at three slice thicknesses of 5, 2.5 and 1.25mm with continuous intervals, using the lung and standard reconstruction algorithms. The lesions were segmented with an in-house 3D algorithm. Fifty (50) image features representing lesion size, shape, edge, and density distribution/texture were computed. Regression method was employed to analyze the effect of CT dose, slice of thickness and reconstruction algorithm on these features adjusting 3 confounding factors (size, density and shape of phantom lesions). Results: The coefficients of CT dose, slice thickness and reconstruction algorithm are presented in Table 1 in the supplementary material. No significant difference was found between the image features calculated on low dose CT scans (25mAs and 50mAs). About 50% texture features were found statistically different between low doses and high doses (100 and 200mAs). Significant differences were found for almost all features when calculated on 1.25mm, 2.5mm, and 5mm slice thickness images. Reconstruction algorithms significantly affected all density-based image features, but not morphological features. Conclusions: There is a great need to standardize the CT imaging protocols for radiogenomics study because CT dose, slice thickness and reconstruction algorithm impact quantitative image features to various degrees as our study has shown.

60 APPLIED LIFE SCIENCES↗

A fast, efficient direct slicing method for slender member structures

We describe a method for quickly and efficiently slicing structures consisting of a large number of slender members called struts connected at node positions called joints. Previous research on periodic lattice structures shows these structures are highly mechanically efficient with exceptionally high stiffness- and strength-to-weight ratios. Additive manufacturing technologies allow the construction slender member structures with complicated macroscale shapes. These structures could consist of thousands or millions of geometric primitives describing the struts. Structures with large numbers of geometric objects cause the conventional methods for manipulating, storing, and slicing the geometry of these parts via STL files to be highly inefficient. This work describes an alternate design process for slender member structures using efficient methods for manipulating, storing, and slicing the geometry of the part. These new methods, in particular a fast, efficient direct slicing method, enable printing slender member structures with over one hundred thousand struts. The slicing algorithm is nearly perfectly parallel so it could extend to handle structures with over one million struts, helping to facilitate the adoption of slender member structures for engineering-scale applications.

36 MATERIALS SCIENCE↗

Low-energy high-brightness electron beam dynamics based on slice beam matrix method

Preserving the phase space quality has been of crucial importance to high-brightness electron beam transport. Any driving source of beam performance limitations in such a transport system must be carefully examined in order to preserve the beam phase space quality. It is found that in the low beam energy, high bunch charge regime, space charge effect on the charged particle beam evolution can be complicated. It may be insufficient to analyze the beam properties through the envelope or lower order moments for the mere bulk of the beam. In this work we will study the space-charge-dominated, low-energy, high-brightness electron beam dynamics based on the slice beam matrix method. The slice beam matrix method, extended from the existing bulk beam analysis, is applicable to an arbitrary longitudinal bunch distribution and can thus take the nonlinear RF curvature into account. The semi-analytical sliced beam space charge model is constructed and assumes an axisymmetric beam in the presence of perfect conducting cylindrical pipe with circular cross section. We present in this paper the theoretical formulation, starting from single-particle dynamics, space charge field calculation, followed by the moment description of a collection of particles, based on beam sigma matrix and longitudinal slice decomposition. We prove the equivalence between the beam matrix method and the envelope formalism in the presence of space charge effect, in both the transverse and longitudinal dimensions. Two examples are then demonstrated, one for a unit cell of superconducting radio-frequency (RF) cavity and the other for a 1.5-cell RF gun system. The semi-analytical results from beam matrix calculation are discussed and compared with particle tracking simulation using ASTRA. In conclusion, we expect that the analysis based on the slice beam matrix method shall serve as an efficient and advanced tool to further investigate the low-energy high-brightness electron beam dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(Non-adiabatic) string creation on nice slices in Schwarzschild black holes

Nice slices have played a pivotal role in the discussion of the black hole information paradox as they avoid regions of strong spacetime curvature and yet smoothly cut through the infalling matter and the outgoing Hawking radiation, thus, justifying the use of low energy field theory. To avoid information loss it has been argued recently, however, that local effective field theory has to break down at the horizon. To assess the extent of this breakdown in a UV complete framework we study string-theoretic effects on nice slices in Schwarzschild black holes. Here, our purpose is two-fold. First, we use nice slices to address various open questions and caveats of [1] where it was argued that boost-enhanced non-adiabatic string-theoretic effects at the horizon could provide a dynamical mechanism for the firewall. Second, we identify two non-adiabatic effects on nice slices in Schwarzschild black holes: pair production of open strings near the horizon enhanced by the presence of the infinite tower of highly excited string states and a late-time non-adiabatic effect intrinsic to nice slices.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantification of fat and skeletal muscle tissue at abdominal computed tomography: associations between single-slice measurements and total compartment volumes

Purpose: Body composition is of great prognostic value in several severe diseases, including different types of cancer as well as cardiometabolic disorders. We aimed to investigate the correlations of skeletal muscle mass and abdominal adipose tissue compartments between volumetric and single-slice measurements to study the usefulness of several anatomical landmarks for estimation of total compartment volumes using abdominal CT-scans. Methods: In this retrospective study volumetric quantifications of paraspinal skeletal muscles (SM) and adipose tissue compartments (visceral adipose tissue, VAT; subcutaneous adipose tissue, SAT) were performed in 50 consecutive patients (26 male; mean age, 63 ± 15 years) who underwent abdominal multislice-CT for diagnostic purposes using an in-house software. Associations between total volumes of SM, VAT, and SAT with single-slice measurements at eight predefined anatomical landmarks (median intervertebral disk spaces T12/L1 to L5/S1; level of the umbilicus (U); level of the radix of the superior mesenteric artery (SMA)) were studied using correlation coefficients. Results: Statistical analysis revealed a strong association between single-slice measurements of adipose tissue compartments with total VAT and SAT volume (VAT: all r > 0.89, P < 0.001; SAT: all r > 0.95, P < 0.001). The strongest associations with total SM volume were found for single-slice measurements obtained at L3/4 (r = 0.94, P < 0.001) and were further improved by normalization to height (r = 0.98, P < 0.001). Conclusions: Single-slice measurements of SM, VAT, and SAT at several anatomical landmarks are strongly associated with total compartment volumes and therefore allow for easy and simultaneous assessment of skeletal muscle mass and adipose tissue compartment volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of monomethylarsonic and monomethylarsonous acid on evoked synaptic potentials in hippocampal slices of adult and young rats

Arsenite and its metabolites, dimethylarsinic or dimethylarsinous acid, have previously been shown to disturb synaptic transmission in hippocampal slices of rats (Krueger, K., Gruner, J., Madeja, M., Hartmann, L.M., Hirner, A.V., Binding, N., Mu{beta}hoff, U., 2006a. Blockade and enhancement of glutamate receptor responses in Xenopus oocytes by methylated arsenicals. Arch. Toxicol. 80, 492-501, Krueger, K., Straub, H., Binding, N., Mu{beta}hoff, U., 2006b. Effects of arsenite on long-term potentiation in hippocampal slices from adult and young rats. Toxicol. Lett. 165, 167-173, Krueger, K., Repges, H., Hippler, J., Hartmann, L.M., Hirner, A.V., Straub, H., Binding, N., Mu{beta}hoff, U., 2007. Effects of dimethylarsinic and dimethylarsinous acid on evoked synaptic potentials in hippocampal slices of young and adult rats. Toxicol. Appl. Pharmacol. 225, 40-46). The present experiments investigate, whether the important arsenic metabolites monomethylarsonic acid (MMA{sup V}) and monomethylarsonous acid (MMA{sup III}) also influence the synaptic functions of the hippocampus. In hippocampal slices of young (14-21 days-old) and adult (2-4 months-old) rats, evoked synaptic field potentials from the Schaffer collateral-CA1 synapse were measured under control conditions and during and after 30 and 60 min of application of the arsenic compounds. MMA{sup V} had no effect on the synapse functions neither in slices of adult nor in those from young rats. However, MMA{sup III} strongly influenced the synaptic transmission: it totally depressed the amplitudes of fEPSPs at concentrations of 50 {mu}mol/l (adult rats) and 25 {mu}mol/l (young rats) and LTP amplitudes at concentrations of 25 {mu}mol/l (adult rats) and 10 {mu}mol/l (young rats), respectively. In contrast, application of 1 {mu}mol/l MMA{sup III} led to an enhancement of the LTP amplitude in young rats, which is interpretable by an enhancing effect on NMDA receptors and a lack of the blocking effect on AMPA receptors at this concentration (Krueger, K., Gruner, J., Madeja, M., Hartmann, L.M., Hirner, A.V., Binding, N., Mu{beta}hoff, U., 2006a. Blockade and enhancement of glutamate receptor responses in Xenopus oocytes by methylated arsenicals. Arch. Toxicol. 80, 492-501). These effects are probably not mediated by changes in cell excitability or in presynaptic glutamate release rates, since antidromically induced population spikes and paired-pulse facilitation failed to show any MMA{sup III} effect. The impairment of the excitatory CA1 synapse is more likely caused by the action of MMA{sup III} on postsynaptic glutamatergic receptors and may be jointly responsible for dysfunctions of cognitive effects in arsenic toxicity.

60 APPLIED LIFE SCIENCES↗

Gene expression analysis of precision-cut human liver slices indicates stable expression of ADME-Tox related genes

In the process of drug development it is of high importance to test the safety of new drugs with predictive value for human toxicity. A promising approach of toxicity testing is based on shifts in gene expression profiling of the liver. Toxicity screening based on animal liver cells cannot be directly extrapolated to humans due to species differences. The aim of this study was to evaluate precision-cut human liver slices as in vitro method for the prediction of human specific toxicity by toxicogenomics. The liver slices contain all cell types of the liver in their natural architecture. This is important since drug-induced toxicity often is a multi-cellular process. Previously we showed that toxicogenomic analysis of rat liver slices is highly predictive for rat in vivo toxicity. In this study we investigated the levels of gene expression during incubation up to 24 h with Affymetrix microarray technology. The analysis was focused on a broad spectrum of genes related to stress and toxicity, and on genes encoding for phase-I, -II and -III metabolizing enzymes and transporters. Observed changes in gene expression were associated with cytoskeleton remodeling, extracellular matrix and cell adhesion, but for the ADME-Tox related genes only minor changes were observed. PCA analysis showed that changes in gene expression were not associated with age, sex or source of the human livers. Slices treated with acetaminophen showed patterns of gene expression related to its toxicity. These results indicate that precision-cut human liver slices are relatively stable during 24 h of incubation and represent a valuable model for human in vitro hepatotoxicity testing despite the human inter-individual variability.

60 APPLIED LIFE SCIENCES↗

Energy enhancement of quasi-monoenergetic proton bunches using a slice-cone target

A slice-cone target is proposed for the generation of quasi-monoenergetic proton bunches. In this new target structure, two symmetrical solid slices are adjoined obliquely to the tip of a hollow cone. Two-dimensional particle-in-cell simulations show that a large number of hot electrons are pulled out from the solid slices and accelerated forward by direct laser acceleration. Compared with the hollow cone target, a stronger electrostatic field at the rear surface of the slice-cone tip is set up by the hot electrons from the cone and the slices. As a result, the energy of the quasi-monoenergetic proton bunch produced through the target-normal sheath acceleration mechanism can be improved by 75%. It shows that the proton energy scales proportional to the square root of the laser intensity. For the incident laser with the focused intensity about 5 x 10{sup 20 }W/cm{sup 2}, one can obtain proton bunches with central energy 165 MeV and energy spread 13%.

43 PARTICLE ACCELERATORS↗

Slicing with deep learning models at ProtoDUNE-SP

DUNE is a cutting-edge experiment aiming to study neutrinos in detail, with a special focus on the flavor oscillation mechanism. The prototype of the DUNE Far Detector Single Phase TPC (ProtoDUNE-SP) was built and operated at CERN with a full set of reconstruction tools. To implement these reconstruction tools, Pandora, a multi-algorithm framework, has been developed. A large number of these algorithms, some of them being exploiting traditional clustering, detector physics and deep learning approaches, have been applied to images to gradually build up a picture out of singular events. One of such algorithms is the Pandora slicing algorithm which aims to partition the detector hits of an event in sets called slices. Each slice represents a single interaction in the detector and should identify all the hits related to the interacting particle and its subsequent decay products. We expect the order of tens of slices per event in ProtoDUNE-SP. In this paper we present a deep learning approach to the problem, designing a model able to outperform the state-of-the-art slicing algorithm which is currently implemented within Pandora. We assess the performance of our tool in terms of efficiency and accuracy, while exploiting hardware accelerating setups. The ultimate goal is to incorporate this deep learning approach in the Pandora reconstruction tool.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Control of the Lasing Slice by Transverse Mismatch in an X-Ray Free-Electron Laser

We demonstrated selective slice-dependent lasing by controlling the matching to the undulator of different slices within an electron bunch. The slice-dependent mismatch was realized through quadrupole wakefield generated in a corrugated structure. A deterministic procedure based on empirical beam transport and phase space information is used to match selected slices by turns to lase in the undulator while keeping all other slices from lasing, thus staying fresh. Measurements of time-resolved electron bunch energy loss by a transverse deflecting cavity confirmed the predicted behavior.

43 PARTICLE ACCELERATORS↗

Short pulse generation by laser slicing at NSLSII

We discuss an upgrade R&D project for NSLSII to generate sub-pico-second short x-ray pulses using laser slicing. We discuss its basic parameters and present a specific example for a viable design and its performance. Since the installation of the laser slicing system into the storage ring will break the symmetry of the lattice, we demonstrate it is possible to recover the dynamical aperture to the original design goal of the ring. There is a rapid growth of ultrafast user community interested in science using sub-pico-second x-ray pulses. In BNL's Short Pulse Workshop, the discussion from users shows clearly the need for a sub-pico-second pulse source using laser slicing method. In the proposal submitted following this workshop, NSLS team proposed both hard x-ray and soft x-ray beamlines using laser slicing pulses. Hence there is clearly a need to consider the R&D efforts of laser slicing short pulse generation at NSLSII to meet these goals.

43 PARTICLE ACCELERATORS↗

Resolving 500 nm axial separation by multi-slice X-ray ptychography

Multi-slice X-ray ptychography offers an approach to achieve images with a nanometre-scale resolution from samples with thicknesses larger than the depth of field of the imaging system by modeling a thick sample as a set of thin slices and accounting for the wavefront propagation effects within the specimen. Here, we present an experimental demonstration that resolves two layers of nanostructures separated by 500 nm along the axial direction, with sub-10 nm and sub-20 nm resolutions on two layers, respectively. Fluorescence maps are simultaneously measured in the multi-modality imaging scheme to assist in decoupling the mixture of low-spatial-frequency features across different slices. The enhanced axial sectioning capability using correlative signals obtained from multi-modality measurements demonstrates the great potential of the multi-slice ptychography method for investigating specimens with extended dimensions in 3D with high resolution.

36 MATERIALS SCIENCE↗