Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SLAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Upgrade of the SLAC SLED II Pulse Compression System Based on Recent High Power Tests

In the Next Linear Collider (NLC) it is expected that the high power rf components be able to handle peak power levels in excess of 400 MW. We present recent results of high power tests designed to investigate the RF breakdown limits of the X-band pulse compression system used at SLAC. (SLED-II). Results of these tests show that both the TE{sub 01}-TE{sub 10} mode converter and the 4-port hybrid have a maximum useful power limit of 220-250 MW. Based on these tests, modifications of these components have been undertaken to improve their peak field handling capability. Results of these modifications will be presented. As part of an international effort to develop a new 0.5-1.5 TeV electron-positron linear collider for the 21st century, SLAC has been working towards a design, referred to as 'The Next Linear Collider' (NLC), which will operate at 11.424 GHz and utilize 50-75 MW klystrons as rf power sources. One of the major challenges in this design, or any other design, is how to generate and efficiently transport extremely high rf power from a source to an accelerator structure. SLAC has been investigating various methods of 'pulse compressing' a relatively wide rf pulse ({ge} 1 {mu}s) from a klystron into a narrower, but more intense, pulse. Currently a SLED-II pulse compression scheme is being used at SLAC in the NLC Test Accelerator (NLCTA) and in the Accelerator Structures Test Area (ASTA) to provide high rf power for accelerator and component testing. In ASTA, a 1.05 {mu}s pulse from a 50 MW klystron was successfully pulse compressed to 205 MW with a pulse width of 150 ns. Since operation in NLC will require generating and transporting rf power in excess of 400 MW it was decided to test the breakdown limits of the SLED-II rf components in ASTA with rf power up to the maximum available of 400 MW. This required the combining of power from two 50 MW klystrons and feeding the summed power into the SLED-II pulse compressor. Results from this experiment demonstrated that two of the key components of SLED-II; the Magic Tee and the 'Flower Petal' mode converter (converts between TE{sub 10} rectangular and TE{sub 01} circular modes), were not robust enough at higher power levels. Because of this, a major effort is underway to upgrade the existing devices to operate stably at the higher power levels, and also to investigate new components, which have inherently low field enhancement in their design and therefore more robust.

43 PARTICLE ACCELERATORS↗

High Frequency, High Gradient Dielectric Wakefield Acceleration Experiments at SLAC and BNL

Given the recent success of >GV/m dielectric wakefield accelerator (DWA) breakdown experiments at SLAC, and follow-on coherent Cerenkov radiation production at the UCLA Neptune, a UCLA-USC-SLAC collaboration is now implementing a new set of experiments that explore various DWA scenarios. These experiments are motivated by the opportunities presented by the approval of FACET facility at SLAC, as well as unique pulse-train wakefield drivers at BNL. The SLAC experiments permit further exploration of the multi-GeV/m envelope in DWAs, and will entail investigations of novel materials (e.g. CVD diamond) and geometries (Bragg cylindrical structures, slab-symmetric DWAs), and have an over-riding goal of demonstrating >GeV acceleration in {approx}33 cm DWA tubes. In the nearer term before FACET's commissioning, we are planning measurements at the BNL ATF, in which we drive {approx}50-200 MV/m fields with single pulses or pulse trains. These experiments are of high relevance to enhancing linear collider DWA designs, as they will demonstrate potential for efficient operation with pulse trains.

36 MATERIALS SCIENCE↗

SLAC All Access: Laser Labs

From supermarket checkouts to video game consoles, lasers are ubiquitous in our lives. Here at SLAC, high-power lasers are critical to the cutting-edge research conducted at the laboratory. But, despite what you might imagine, SLAC's research lasers bear little resemblance to the blasters and phasers of science fiction. In this edition of All Access we put on our safety goggles for a peek at what goes on inside some of SLAC's many laser labs. LCLS staff scientist Mike Minitti and SLAC laser safety officer Mike Woods detail how these lasers are used to study the behavior of subatomic particles, broaden our understanding of cosmic rays and even unlock the mysteries of photosynthesis.

47 OTHER INSTRUMENTATION↗

Transport of LCLS-II 1.3 Ghz cryomodule to SLAC

In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These include a prototype built and delivered by each Lab. Another two 3.9 GHz cryomodules will be built, tested and transported by Fermilab to SLAC. Each assembly will be transported over-the-road from Fermilab or Jefferson Lab using specific routes to SLAC. The transport system consists of a base frame, isolation fixture and upper protective truss. The strongback cryomodule lifting fixture is described along with other supporting equipment used for both over-the-road transport and local (on-site) transport at Fermilab. Initially, analysis of fragile components and stability studies will be performed in order to assess the risk associated with over-the-road transport of a fully assembled cryomodule.

43 PARTICLE ACCELERATORS↗

SLAC All Access: FACET

SLAC's Facility for Advanced Accelerator Experimental Tests, or FACET, is a test-bed where researchers are developing the technologies required for particle accelerators of the future. Scientists from all over the world come to explore ways of improving the power and efficiency of the particle accelerators used in basic research, medicine, industry and other areas important to society. In this video, Mark Hogan, head of SLAC's Advanced Accelerator Research Department, offers a glimpse into FACET, which uses part of SLAC's historic two-mile-long linear accelerator.

43 PARTICLE ACCELERATORS↗

TES X-ray Spectrometer at SLAC LCLS-II

We are building a transition edge sensor (TES) X-ray spectrometer for the Linac Coherent Light Source (LCLS-II) at SLAC National Accelerator Laboratory (SLAC) to coincide with new upgrades for this free electron laser facility. This new X-ray spectrometer will have 1000 TES pixels with 0.5 eV energy resolution for soft X-rays below 1 keV. Multiplexing will be done with microwave SQUID resonators and new specialized electronic hardware developed at SLAC. This spectrometer will use a dilution refrigerator to achieve lower operating temperatures than previous TES spectrometers and will be coupled to the liquid jet endstation at LCLS-II. The spectrometer is designed to operate at much higher count rates than previous TES X-ray spectrometers to take advantage of the high repetition rate of the LCLS-II. Science applications will utilize the high photon collection efficiency and throughput, high energy resolution, as well as its ability to simultaneously measure its full calibrated energy range.

47 OTHER INSTRUMENTATION↗

SLAC Cosmic Ray Telescope Facility

SLAC does not have a test beam for the HEP detector development at present. We have therefore created a cosmic ray telescope (CRT) facility, which is presently being used to test the FDIRC prototype. We have used it in the past to debug this prototype with the original SLAC electronics before going to the ESA test beam. Presently, it is used to test a new waveform digitizing electronics developed by the University of Hawaii, and we are also planning to incorporate the new Orsay TDC/ADC electronics. As a next step, we plan to put in a full size DIRC bar box with a new focusing optics, and test it together with a final SuberB electronics. The CRT is located in building 121 at SLAC. We anticipate more users to join in the future. This purpose of this note is to provide an introductory manual for newcomers.

43 PARTICLE ACCELERATORS↗

SLAC Disk Loaded Waveguide (DLWG) Accelerator Structure

This drawing package is for the SLAC s-band DLWG accelerator structures used in the original linac. These structures are still operating to this day serving in the SLAC LCLS-I and FACET linacs. For access to the drawings, contact the SLAC Office of Research Partnerships & Technology Commercialization (IPRP@slac.stanford.edu).

Tremaine, Aaron↗

Preliminary Conceptual Design Report for the FACET-II Project at SLAC National Accelerator Laboratory

Plasma wakefield acceleration has the potential to dramatically shrink the size and cost of particle accelerators. Research at the SLAC National Accelerator Laboratory has demonstrated that plasmas can provide 1,000 times the acceleration in a given distance compared with current technologies. Developing revolutionary and more efficient acceleration techniques that allow for an affordable high-energy collider is the focus of FACET, a National User Facility at SLAC. The existing FACET National User Facility uses part of SLAC’s two-mile-long linear accelerator to generate high-density beams of electrons and positrons. FACET-II is a new test facility to develop advanced acceleration and coherent radiation techniques with high-energy electron and positron beams. It is the only facility in the world with high energy positron beams. FACET-II provides a major upgrade over current FACET capabilities and the breadth of the potential research program makes it truly unique. It will synergistically pursue accelerator science that is vital to the future of both advanced acceleration techniques for High Energy Physics, ultra-high brightness beams for Basic Energy Science, and novel radiation sources for a wide variety of applications. The design parameters for FACET-II are set by the requirements of the plasma wakefield experimental program. To drive the plasma wakefield requires a high peak current, in excess of 10kA. To reach this peak current, the electron and positron design bunch size is 10μ by 10μ transversely with a bunch length of 10μ. This is more than 200 times better than what has been achieved at the existing FACET. The beam energy is 10 GeV, set by the Linac length available and the repetition rate is up to 30 Hz. The FACET-II project is scheduled to be constructed in three major stages. Components of the project discussed in detail include the following: electron injector, bunch compressors and linac, the positron system, the Sector 20 sailboat and W chicanes, and experimental area and infrastructure.

43 PARTICLE ACCELERATORS↗

Recent Progress in Electron Scattering at SLAC

Since the last meeting in this conference series in Paris in 1981, there has been major progress in electron scattering at SLAC on several fronts. A new experiment on ep elastic scattering at large momentum transfer, Experiment El36, has recently completed data taking. A new measurement of deep inelastic electron scattering from nuclear targets, Experiment El39, has been completed and preliminary results are available. A new program of experiments has begun, called Nuclear Physics at SLAC (NPAS), that will use a new injector on the SLAC linac to provide high intensity beams in the energy range from 0.5 to 6 GeV.

43 PARTICLE ACCELERATORS↗

High Power S-Band Vacuum Dry Loads for SLAC Linac

In the beginning of LCLS-1 commission era, an unstable termination mode of the residual RF power on all vacuum dry loads of the SLAC linac was found. The S-Band loads on the current SLAC linac RF system were designed, in some cases, 50+ years ago to terminate stably only 2-3 MW peak power into a thin layer of coated Kanthal material as the high power absorber. The technology of the load design was based on a old flame-sprayed Kanthal wire method onto a base material. During SLAC linac upgrades, the RF power sources dramatically increased from 24 MW peak klystrons to 240 MW peak (with new klystrons and SLED cavities). As a result, the residual RF power on the loads was increased accordingly. The original RF loads were overstressed and cannot stably terminate the residual RF power in the present RF linac layout.

43 PARTICLE ACCELERATORS↗

Annual Site Environmental Report: 2020 (ASER) for the SLAC National Accelerator Laboratory

To satisfy the requirements of the United States Department of Energy (DOE) SLAC Site Office approved Site Compliance Plan for DOE Order 231.1B (Change 1, 2012, “Environment, Safety and Health Reporting,” the Environment, Safety and Health Division (ES&H) of the SLAC National Accelerator Laboratory prepares an annual report describing its environmental programs and activities. This Annual Site Environmental Report: 2020 summarizes the SLAC National Accelerator Laboratory compliance with standards and requirements, describes the management and monitoring systems in place, and highlights significant accomplishments for the year.

54 ENVIRONMENTAL SCIENCES↗

Annual Site Environmental Report: 2019 (ASER) for the SLAC National Accelerator Laboratory

To satisfy the requirements of the United States Department of Energy (DOE) SLAC Site Office approved Site Compliance Plan for DOE Order 231.1B, “Environment, Safety and Health Reporting,” the Environment, Safety and Health Division (ES&H) of the SLAC National Accelerator Laboratory prepares an annual report describing its environmental programs and activities. This Annual Site Environmental Report: 2019 summarizes the SLAC National Accelerator Laboratory compliance with standards and requirements, describes the management and monitoring systems in place, and highlights significant accomplishments for the year.

54 ENVIRONMENTAL SCIENCES↗

Annual Site Environmental Report: 2018 (ASER) for the SLAC National Accelerator Laboratory

To satisfy the requirements of the United States Department of Energy (DOE) SLAC Site Office approved Site Compliance Plan for DOE Order 231.1B, “Environment, Safety and Health Reporting,” the Environment, Safety and Health Division (ES&H) of the SLAC National Accelerator Laboratory prepares an annual report describing its environmental programs and activities. This Annual Site Environmental Report: 2018 summarizes the SLAC National Accelerator Laboratory compliance with standards and requirements, describes the management and monitoring systems in place, and highlights significant accomplishments for the year.

54 ENVIRONMENTAL SCIENCES↗

Recent Upgrade of the Klystron Modulator at SLAC

The SLAC National Accelerator Laboratory employs 244 klystron modulators on its two-mile-long linear accelerator that has been operational since the early days of the SLAC establishment in the sixties. Each of these original modulators was designed to provide 250 kV, 262 A and 3.5 {mu}S at up to 360 pps using an inductance-capacitance resonant charging system, a modified type-E pulse-forming network (PFN), and a pulse transformer. The modulator internal control comprised of large step-start resistor-contactors, vacuum-tube amplifiers, and 120 Vac relays for logical signals. A major, power-component-only upgrade, which began in 1983 to accommodate the required beam energy of the SLAC Linear Collider (SLC) project, raised the modulator peak output capacity to 360 kV, 420 A and 5.0 {mu}S at a reduced pulse repetition rate of 120 pps. In an effort to improve safety, performance, reliability and maintainability of the modulator, this recent upgrade focuses on the remaining three-phase AC power input and modulator controls. The upgrade includes the utilization of primary SCR phase control rectifiers, integrated fault protection and voltage regulation circuitries, and programmable logic controllers (PLC) -- with an emphasis on component physical layouts for safety and maintainability concerns. In this paper, we will describe the design and implementation of each upgraded component in the modulator control system. We will also report the testing and present status of the modified modulators.

43 PARTICLE ACCELERATORS↗

Initial Testing of the Mark-0 X-Band RF Gun at SLAC

A new X-band RF gun (Mark-0) has been assembled, tuned and was tested in the ASTA facility at SLAC. This gun has been improved from an earlier gun used in Compton-scattering experiments at SLAC by the introduction of a racetrack dual-input coupler to reduce quadrupole fields. Waveguide-to-coupler irises were also redesigned to reduce surface magnetic fields and therefore peak pulse surface heating. Tests of this photocathode gun will allow us to gain early operational experience for beam tests of a new gun with further improvements (Mark-1) being prepared for SLAC's X-Band Test Area (XTA) program and the LLNL MEGa-ray program. Results of current testing up to {approx} 200 MV/m peak surface Electric fields are presented.

43 PARTICLE ACCELERATORS↗

S-Band Loads for SLAC Linac

The S-Band loads on the current SLAC linac RF system were designed, in some cases, 40+ years ago to terminate 2-3 MW peak power into a thin layer of coated Kanthal material as the high power absorber [1]. The technology of the load design was based on a flame-sprayed Kanthal wire method onto a base material. During SLAC linac upgrades, the 24 MW peak klystrons were replaced by 5045 klystrons with 65+ MW peak output power. Additionally, SLED cavities were introduced and as a result, the peak power in the current RF setup has increased up to 240 MW peak. The problem of reliable RF peak power termination and RF load lifetime required a careful study and adequate solution. Results of our studies and three designs of S-Band RF load for the present SLAC RF linac system is discussed. These designs are based on the use of low conductivity materials.

36 MATERIALS SCIENCE↗

Coincident learning for beam-based rf station fault identification using phase information at the SLAC linac coherent light source

Anomalies in radio-frequency (rf) stations can result in unplanned downtime and performance degradation in linear accelerators such as SLAC’s Linac Coherent Light Source (LCLS). Detecting these anomalies is challenging due to the complexity of accelerator systems, high data volume, and scarcity of labeled fault data. Prior work identified faults using beam-based detection, combining rf amplitude and beam position monitor data. Due to the simplicity of the rf amplitude data, classical methods are sufficient to identify faults, but the recall is constrained by the low-frequency and asynchronous characteristics of the data. In this work, we leverage high-frequency, time-synchronous rf phase data to enhance anomaly detection in the LCLS accelerator. Due to the complexity of phase data, classical methods fail, and we instead train deep neural networks within the Coincident Anomaly Detection (CoAD) framework. We find that applying CoAD to phase data detects nearly 3 times as many anomalies as when applied to amplitude data, while achieving broader coverage across rf stations. Furthermore, the rich structure of phase data enables us to cluster anomalies into distinct physical categories. Through the integration of auxiliary system status bits, we link clusters to specific fault signatures, providing additional granularity for uncovering the root cause of faults. We also investigate interpretability via Shapley values, confirming that the learned models focus on the most informative regions of the data and providing insight for cases where the model makes mistakes. This work demonstrates that phase-based anomaly detection for rf stations improves both diagnostic coverage and root cause analysis in accelerator systems and that deep neural networks are essential for effective analysis.

Accelerator Physics (physics.acc-ph)↗