Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SLABS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Quantitative Evaluations of Surface Cleanliness in IF Steel Slabs at Unsteady Casting

Macro-inclusions in the surface layer of slabs are mainly responsible for the sliver defects in IF steel sheets. In the present work, macro-inclusions in six kinds of unsteady cast IF steel slabs involving four unsteady states (casting start, ladle change, nozzle change and casting end) in one casting sequence were quantitatively characterized using an automatic inclusion analyzer with a total detection area of 238,048 mm{sup 2}. The cleanliness of corresponding normal slabs was also evaluated as the benchmark study, and the number density (ND) of inclusions > 50 µm was used to describe the surface slab cleanliness. Generally, alumina-based and mold powder inclusions were detected, and the former type was further subdivided into alumina clusters, alumina associated with bubbles, refractory-related alumina, Al-Ti complex oxides and CaO-Al{sub 2}O{sub 3}-MgO. Several large-sized alumina-based inclusions were detected in the normal slabs with an average ND of 0.31 N/cm{sup 2}, although they had very low total oxygen (TO) contents (10~13 ppm). No mold powder inclusions were found in normal slabs. For all the unsteady slabs, alumina-based and mold powder inclusions were both observed, and the percentage of the former kind was ≥ 90 pct. The average density of macro-inclusions for the first slab was 1.621 N/cm{sup 2}, whose cleanliness was much worse than any of the other unsteady slabs. The first slab should be downgraded. For the second slab, the ND of macro-inclusions was 0.385 N/cm{sup 2}, which was still larger than the normal slabs because of the lasting effect of the re-oxidation. For the penultimate, cap-off and SEN changed slabs, the density of macro-inclusions fluctuated from 0.25~0.35 N/cm{sup 2}, which was close to the average level of normal slabs. However, mold flux-originated inclusions were frequently observed in these slabs because of flow pattern variations due to the casting speed change. In terms of the slab during the ladle change process, mold powder inclusions were frequently detected even though the casting speed remained constant. A mold powder entrapment mechanism was proposed, which showed the entrapment occurred owing to the flow pattern change induced by forming/dropping of SEN clogs due to re-oxidation by FeO in the ladle slag and tundish steel temperature variations during the ladle change practice. The severity of powder entrapment and re-oxidation was also given for different kinds of unsteady slabs, which provides a direct guide to treating these slabs in the steel plant.

36 MATERIALS SCIENCE↗

Evolution of attached and detached slabs and their associated mantle dynamics

Over the two years of the NASA grant, this project has produced a significant amount of research results related to the plate subduction process and the surface crustal deformation at convergent boundaries (i.e., above subduction zones). While some research objectives are completely accomplished, other research tasks remain active and continue to be investigated at present. A steady state analytic thermal model for subducting slabs was used to examine the torques acting on a descending slab. It is found that gravitational torque vanishes when a slab is dipping either vertically or horizontally, unlike previous studies indicating that the magnitude of gravitational torque decreases as dip angle increases. Subsequently, a new time-dependent, analytic thermal model for a subducting slab was developed. The new model enables us to study transient phenomena associated with plate subduction analytically. On the basis of this model, the nature of slab dip angles was evaluated. Slab dip angles are found to be transient features. As they penetrate into the mantle and increase their lengths, the associated gravitational torque also increases resulting in a downward pulling of the slab to the steeper dip angle. This is especially true once a slab penetrates the olivine-spinel phase boundary at about 400 km depth. However, if the phase transformation does not follow the equilibrium condition, the gravitational torque may have a different behavior. This problem was investigated. Except for fast descending slabs, non-equilibrium phase transformation can only slow down the transient increase of slab dip angles discussed earlier. Its effect is not sufficiently strong to reverse the downward pulling for most of the slabs. However, when slabs subducting at 10 cm/yr or faster, a sufficient amount of metastable olivine can exist beneath 400 km. Because of its low density compared with the surrounding spinel, an upward buoyancy is produced resulting in an upward bending of the slab and possibly an upward rotation of the slab such that smaller dip angles are formed. Seismic studies of the Japanese Slab seem to support this interpretation. The development of oroclinal geometries at convergent boundaries was also examined to study plate obduction which is an important ingredient to the initiation of plate subduction. Although the study suggests that surface features are better modeled by block models, the large scale deformation can be adequately studied by viscous models. Such a model is now under development to complete our original objective to study the initiation of plate subduction. Finally, a three-dimensional, finite element, spherical convective model is developed to study dynamic plate subductions. The model development is now complete and it is being tested to ensure its proper operation. The model is able to generate convection results with a viscosity contrast of about 100. Our research continues to push the viscosity contrast to a level that is appropriate for a subducting slab.

Hsui, Albert T.↗

Punching behavior of BubbleDeck type reinforced concrete slabs

Abstract The BubbleDeck type slab (BD) is a reinforced concrete (RC) flat slab that includes recycled plastic hollow spheres (RPHS) in its core for decreasing its dead weight. However, punching capacity of BD slabs can be a critical aspect, thereby this work is devoted to assess experimentally its punching behavior. An experimental program composed of four real scale prototypes, representative of RC flat slabs in punching loading conditions, was carried out. Two of these slabs are of BD type, while the other two do not include the RPHS system, herein denominated as RC solid slab (SS). The test results show that all the tested slabs failed in punching after the occurrence of yield initiation of the flexural reinforcement. The punching capacity and the deflection at failure of BD type slab has decreased up to 14% and up to 44%, respectively, when compared to the corresponding SS type slab. A relatively small ductility index was obtained (between 1.51 and 2.65). In BD type slabs, the punching failure surface had tendency to propagate through the RPHS, at an inclination angle of about 45°.

Nicácio, Wanderley G.↗

Propagation of surface waves and waveguide modes guided by a dielectric slab inserted in a sculptured nematic thin film

Wave propagation guided by a dielectric slab inserted in a sculptured nematic thin film (SNTF) was studied theoretically. Two types of guided waves can be identified: (i) surface (Dyakonov-Tamm) waves guided by one or both of the two planar interfaces of the dielectric slab and the SNTF, and (ii) waveguide modes in the dielectric waveguide formed by the slab with the SNTF as the cladding. As the thickness of the dielectric slab is increased, the number of waveguide modes increases. If the slab thickness is less than twice the e-folding distance into the dielectric slab, the Dyakonov-Tamm waves propagate coupled to both interfaces; the coupling decreases and eventually vanishes as the slab thickness increases, so that Dyakonov-Tamm waves are guided by the individual dielectric-SNTF interfaces independently. The chosen structure supports the propagation of Dyakonov-Tamm waves in all directions, in contrast to the restricted range of propagation supported by a single SNTF-dielectric interface. Propagation of both Dyakonov-Tamm waves and waveguide modes should occur in practice with negligible attenuation, in contrast to that of surface-plasmon-polariton waves that are guided when the dielectric slab is replaced by a metal slab.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mantle circulation and the lateral migration of subducted slabs

The geometry of transverse migration of subducted lithospheric slabs is examined, and the way in which this influences the flow in the mantle is studied. The migration of subducted slabs generally appears to be retrograde (at rates of 10-25 mm/yr), so that the descent of material is actually steeper than the slab dip. Retrograde slab migration is probably caused by the tendence of negatively buoyant slabs to sink in the surrounding mantle. The properties of the flow driven by such retrograde slab migration are explored in simple two-dimensional models. The results are used as a guide to infer the contribution of retrograde slab motion to the more complex mantle flow and to examine some consequences of the additional component of mantle flow. It is shown that slab migration is an important factor that causes mantle flow to be geometrically complex and time dependent.

Garfunkel, Z.↗

Determination of a natural basis function set on thick, structured slabs using Prony's method

The calculation of currents on a thick, structured slab such as a thick slab of honeycomb is discussed. Unfortunately, for certain applications, the slab can be on the order of several wavelengths, so that the straightforward application of the method of moments using subdomain basis functions is too expensive. The authors discuss how to apply Prony's method to the currents calculated for a thin, structured slab to obtain a natural set of basis functions to represent the currents in the interior of a thick slab. Prony's method represents the currents as a series of complex exponential functions. The thick slab problem is then solved by the method of moments using subdomain basis functions near the slab interfaces and one or two of the complex exponentials as basis functions within the slab.

Jorgenson, Roy E.↗

Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida

During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floors according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida

During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floors according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

THE PERIOD RATIO FOR STANDING KINK AND SAUSAGE MODES IN SOLAR STRUCTURES WITH SIPHON FLOW. I. MAGNETIZED SLABS

In the applications of solar magneto-seismology, the ratio of the period of the fundamental mode to twice the period of its first overtone, P{sub 1}/2P{sub 2}, plays an important role. We examine how field-aligned flows affect the dispersion properties, and hence the period ratios, of standing modes supported by magnetic slabs in the solar atmosphere. We numerically solve the dispersion relations and devise a graphic means to construct standing modes. For coronal slabs, we find that the flow effects are significant for the fast kink and sausage modes alike. For the kink ones, they may reduce P{sub 1}/2P{sub 2} by up to 23% compared with the static case, and the minimum allowed P{sub 1}/2P{sub 2} can fall below the lower limit analytically derived for static slabs. For the sausage modes, while introducing the flow reduces P{sub 1}/2P{sub 2} by typically {approx}< 5% relative to the static case, it significantly increases the threshold aspect ratio only above which standing sausage modes can be supported, meaning that their detectability is restricted to even wider slabs. In the case of photospheric slabs, the flow effect is not as strong. However, standing modes are distinct from the coronal case in that standing kink modes show a P{sub 1}/2P{sub 2} that deviates from unity even for a zero-width slab, while standing sausage modes no longer suffer from a threshold aspect ratio. We conclude that transverse structuring in plasma density and flow speed should be considered in seismological applications of multiple periodicities to solar atmospheric structures.

79 ASTRONOMY AND ASTROPHYSICS↗

Building America Case Study: Impact of Slab-Foundation Heat Transfer on Space-Conditioning Energy Use in Florida, Cocoa, Florida

Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new home floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Impact of Slab-Foundation Heat Transfer on Space-Conditioning Energy Use in Florida, Cocoa, Florida

Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new home floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.

BAPIRC↗

First-principles calculations of metal surfaces. I. Slab-consistent bulk reference for convergent surface properties

The first-principles computation of the surfaces of metals is typically accomplished through slab calculations of finite thickness. The extraction of a convergent surface formation energy from slab calculations is dependent upon defining an appropriate bulk reference energy. I describe a method for an independently computed, slab-consistent bulk reference that leads to convergent surface formation energies from slab calculations that also provides realistic uncertainties for the magnitude of unavoidable nonlinear divergence in the surface formation energy with slab thickness. In conclusion, the accuracy is demonstrated on relaxed, unreconstructed low-index aluminum surfaces with slabs with up to 35 layers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Combustion of solid fuel slabs with gaseous oxygen in a hybrid motor analog

Using a high-pressure, two-dimensional hybrid motor, an experimental investigation was conducted on fundamental processes involved in hybrid rocket combustion. HTPB (Hydroxyl-terminated- Polybutadiene) fuel cross linked with diisocyanate was burned with GOX under various operating conditions. Large amplitude pressure oscillations were encountered in earlier test runs. After identifying the source of instability and decoupling the GOX feed line system and combustion chamber, the pressure oscillations were drastically reduced from +/- 20% of the localized mean pressure to an acceptable range of +/- 1.5%. Embedded fine-wire thermocouples indicated that the surface temperature of the burning fuel was around 1000 K depending upon axial locations and operating conditions. Also, except near the leading-edge region, the subsurface thermal wave profiles in the upstream locations arc thicker than those in the downstream locations since the solid-fuel regression rate, in general, increases with distance along the fuel slab. The recovered solid fuel slabs in the laminar portion of the boundary layer exhibited smooth surfaces, indicating the existence of a liquid melt layer on the burning fuel surface in the upstream region. After the transition section, which displayed distinct transverse striations, the surface roughness pattern became quite random and very pronounced in the downstream turbulent boundary-layer region. Both real time X-ray radiography and ultrasonic pulse-echo techniques were used to determine the instantaneous web thicknesses and instantaneous solid-fuel regression rates over certain portions of the fuel slabs. Globally averaged and axially dependent but time-averaged regression rates were also obtained and presented. Several tests were conducted using, simultaneously, one translucent fuel slab and one fuel slab processed with carbon black powder. The addition of carbon black did not affect the measured regression rates or surface temperatures in comparison to the translucent fuel slabs.

Chiaverini, Martin J.↗

Combustion of solid fuel slabs with gaseous oxygen in a hybrid motor analog

Using a high-pressure, two-dimensional hybrid motor, an experimental investigation was conducted on fundamental processes involved in hybrid rocket combustion. HTPB (Hydroxyl-terminated Polybutadiene) fuel cross-linked with diisocyanate was burned with gaseous oxygen (GOX) under various operating conditions. Large-amplitude pressure oscillations were encountered in earlier test runs. After identifying the source of instability and decoupling the GOX feed-line system and combustion chamber, the pressure oscillations were drastically reduced from plus or minus 20% of the localized mean pressure to an acceptable range of plus or minus 1.5%. Embedded fine--wire thermocouples indicated that the surface temperature of the burning fuel was around 1000 K depending upon axial locations and operating conditions. Also, except near the leading edge region, the subsurface thermal wave profiles in the upstream locations are thicker than those in the downstream locations since the solid-fuel regression rate, in general, increases with distance along the fuel slab. The recovered solid fuel slabs in the laminar portion of the boundary layer exhibited smooth surfaces, indicating the existence of a liquid melt layer on the burning fuel surface in the upstream region. After the transition section, which displayed distinct transverse striations, the surface roughness pattern became quite random and very pronounced in the downstream turbulent boundary-layer region. Both real-time X-ray radiography and ultrasonic pulse echo techniques were used to determine the instantaneous web thicknesses and instantaneous solid-fuel regression rates over certain portions of the fuel slabs. Globally averaged and axially dependent but time-averaged regression rates were also obtained and presented. Several tests were conducted using, simultaneously, one translucent fuel slab and one fuel slab processed with carbon black powder. The addition of carbon black did not affect the measured regression rates or surface temperatures in comparison to the translucent fuel slabs.

Chiaverini, Martin J.↗

A Numerical Method for Obtaining Monoenergetic Neutron Flux Distributions and Transmissions in Multiple-Region Slabs

This method is investigated for semi-infinite multiple-slab configurations of arbitrary width, composition, and source distribution. Isotropic scattering in the laboratory system is assumed. Isotropic scattering implies that the fraction of neutrons scattered in the i(sup th) volume element or subregion that will make their next collision in the j(sup th) volume element or subregion is the same for all collisions. These so-called "transfer probabilities" between subregions are calculated and used to obtain successive-collision densities from which the flux and transmission probabilities directly follow. For a thick slab with little or no absorption, a successive-collisions technique proves impractical because an unreasonably large number of collisions must be followed in order to obtain the flux. Here the appropriate integral equation is converted into a set of linear simultaneous algebraic equations that are solved for the average total flux in each subregion. When ordinary diffusion theory applies with satisfactory precision in a portion of the multiple-slab configuration, the problem is solved by ordinary diffusion theory, but the flux is plotted only in the region of validity. The angular distribution of neutrons entering the remaining portion is determined from the known diffusion flux and the remaining region is solved by higher order theory. Several procedures for applying the numerical method are presented and discussed. To illustrate the calculational procedure, a symmetrical slab ia vacuum is worked by the numerical, Monte Carlo, and P(sub 3) spherical harmonics methods. In addition, an unsymmetrical double-slab problem is solved by the numerical and Monte Carlo methods. The numerical approach proved faster and more accurate in these examples. Adaptation of the method to anisotropic scattering in slabs is indicated, although no example is included in this paper.

Schneider, Harold↗

Thermal Lens Measurement in Diode-Pumped Nd:YAG Zig-Zag Slab

A major advantage that solid state zig-zag slab lasers have over conventional rod-based designs is that a much weaker thermal lens is produced in the slab when side-pumped with Quasi-CW laser diode arrays, particularly if the pump radiation is kept well away from the Brewster-cut ends. This paper reports on a rather strong thermal lens produced when diode pump radiation is collimated into a narrow portion of the zig-zag slab. The collimation of multi-bar pump packages to increase brightness and improve overlap is a direct consequence of designs which seek to maximize performance and efficiency. Our slab design employed a 8.1 cm x 2.5 mm x 5 mm slab with opposing Brewster end faces. It was pumped through the 2.5 mm direction by seven laser diode array packages, each housing four 6OW diode bars, 1 cm in width. The pump face, anti-reflection (AR) coated at 809 nm, was 6.8 cm in width and the 8.1 cm opposing side, high-reflection (HR) coated at 809 nm, reflected the unabsorbed pump beam for a second pass through the slab.

Smoak, M. C.↗

An Empirical Algorithm to Map Perennial Firn Aquifers and Ice Slabs Within the Greenland Ice Sheet Using Satellite L-band Microwave Radiometry

Perennial firn aquifers are subsurface meltwater reservoirs consisting of a meters-thick water-saturated firn layer that can form on spatial scales as large as tens of kilometers. They have been observed within the percolation facies of glaciated regions experiencing intense seasonal surface melting and high snow accumulation. Widespread perennial firn aquifers have been identified within the Greenland Ice Sheet (GrIS) via field expeditions, airborne ice-penetrating radar surveys, and satellite microwave sensors. In contrast, ice slabs are nearly continuous ice layers that can also form on spatial scales as large as tens of kilometers as a result of surface and subsurface water-saturated snow and firn layers sequentially refreezing following multiple melting seasons. They have been observed within the percolation facies of glaciated regions experiencing intense seasonal surface melting but in areas where snow accumulation is at least 25 % lower as compared to perennial firn aquifer areas. Widespread ice slabs have recently been identified within the GrIS via field expeditions and airborne ice-penetrating radar surveys, specifically in areas where perennial firn aquifers typically do not form. However, ice slabs have yet to be identified from space. Together, these two ice sheet features represent distinct, but related, sub-facies within the broader percolation facies of the GrIS that can be defined primarily by differences in snow accumulation, which influences the englacial hydrology and thermal characteristics of firn layers at depth. Here, for the first time, we use enhanced-resolution vertically polarized L-band brightness temperature () imagery (2015–2019) generated using observations collected over the GrIS by NASA's Soil Moisture Active Passive (SMAP) satellite to map perennial firn aquifer and ice slab areas together as a continuous englacial hydrological system. We use an empirical algorithm previously developed to map the extent of Greenland's perennial firn aquifers via fitting exponentially decreasing temporal L-band signatures to a set of sigmoidal curves. This algorithm is recalibrated to also map the extent of ice slab areas using airborne ice-penetrating radar surveys collected by NASA's Operation IceBridge (OIB) campaigns (2010–2017). Our SMAP-derived maps show that between 2015 and 2019, perennial firn aquifer areas extended over 64 000 km2, and ice slab areas extended over 76 000 km2. Combined together, these sub-facies are the equivalent of 24 % of the percolation facies of the GrIS. As Greenland's climate continues to warm, seasonal surface melting will increase in extent, intensity, and duration. Quantifying the possible rapid expansion of these sub-facies using satellite L-band microwave radiometry has significant implications for understanding ice-sheet-wide variability in englacial hydrology that may drive meltwater-induced hydrofracturing and accelerated ice flow as well as high-elevation meltwater runoff that can impact the mass balance and stability of the GrIS.

Julie Z Miller↗