Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SILVER IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effect of 100 MeV swift heavy ions [silver (Ag{sup 8+})] on morphological and electrical properties of polypyrrole

Polypyrrole (PPY) films were prepared by the electrochemical polymerization technique. The fully undoped samples were irradiated with different fluences ranging from 10{sup 10} to 10{sup 12} ions/cm{sup 2} of 100 MeV silver (Ag{sup 8+}) ions. In order to explain the effect of these radiations, a comparative study of samples before and after irradiation was performed by using various techniques such as surface electron microscopy, atomic force microscopy, and X-ray diffraction. With an increase in fluence, the surface structure of PPY films becomes smoother, and the conductivity increases by two orders, which has been explained in light of reordering of polymer chains. The temperature dependence of the dc conductivity of irradiated as well as unirradiated samples has been investigated at 77-300 K. The charge transport properties before and after irradiation are retained although conductivity increases. It has been proposed that swift heavy ion irradiation affects the interchain conductivity. The conductivity of irradiated samples is stable under atmospheric conditions for more than 9 months. The present investigations open up the scope for the applicability of irradiated conducting polymers as microstructures with defined conductivity for sensor applications.

36 MATERIALS SCIENCE↗

Formation of Porous Germanium Layers by Silver-Ion Implantation

We propose a method for the formation of porous germanium (P-Ge) layers containing silver nanoparticles by means of high-dose implantation of low-energy Ag{sup +} ions into single-crystalline germanium (c-Ge). This is demonstrated by implantation of 30-keV Ag{sup +} ions into a polished c-Ge plate to a dose of 1.5 × 10{sup 17} ion/cm{sup 2} at an ion beam-current density of 5 μA/cm{sup 2}. Examination by high-resolution scanning electron microscopy (SEM), atomic-force microscopy (AFM), X-ray diffraction (XRD), energy-dispersive X-ray (EDX) microanalysis, and reflection high-energy electron diffraction (RHEED) showed that the implantation of silver ions into c-Ge surface led to the formation of a P-Ge layer with spongy structure comprising a network of interwoven nanofibers with an average diameter of ∼10–20 nm Ag nanoparticles on the ends of fibers. It is also established that the formation of pores during Ag{sup +} ion implantation is accompanied by effective sputtering of the Ge surface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Hypoxia inducible factor-1 (HIF-1)–flavin containing monooxygenase-2 (FMO-2) signaling acts in silver nanoparticles and silver ion toxicity in the nematode, Caenorhabditis elegans

In the present study, nanotoxicity mechanism associated with silver nanoparticles (AgNPs) exposure was investigated on the nematode, Caenorhabditis elegans focusing on the hypoxia response pathway. In order to test whether AgNPs-induced hypoxia inducible factor-1 (HIF-1) activation was due to hypoxia or to oxidative stress, depletion of dissolved oxygen (DO) in the test media and a rescue effect using an antioxidant were investigated, respectively. The results suggested that oxidative stress was involved in activation of the HIF-1 pathway. We then investigated the toxicological implications of HIF-1 activation by examining the HIF-1 mediated transcriptional response. Of the genes tested, increased expression of the flavin containing monooxygenase-2 (FMO-2) gene was found to be the most significant as induced by AgNPs exposure. We found that AgNPs exposure induced FMO-2 activation in a HIF-1 and p38 MAPK PMK-1 dependent manner, and oxidative stress was involved in it. We conducted all experiments to include comparison of AgNPs and AgNO{sub 3} in order to evaluate whether any observed toxicity was due to dissolution or particle specific. The AgNPs and AgNO{sub 3} did not produce any qualitative differences in terms of exerting toxicity in the pathways observed in this study, however, considering equal amount of silver mass, in every endpoint tested the AgNPs were found to be more toxic than AgNO{sub 3}. These results suggest that Ag nanotoxicity is dependent not only on dissolution of Ag ion but also on particle specific effects and HIF-1–FMO-2 pathway seems to be involved in it. - Highlights: • HIF-1 signaling was investigated in C. elegans exposed to AgNPs and AgNO{sub 3}. • HIF-1 and PMK-1 were needed for AgNPs- and AgNO{sub 3}-induced fmo-2 gene expression. • PMK-1–HIF-1–FMO-2 pathway was dependent on oxidative stress. • AgNPs and AgNO{sub 3} did not produce any qualitative differences in HIF-1 signaling. • AgNPs were more toxic than an equal amount of silver mass contained in AgNO{sub 3}.

60 APPLIED LIFE SCIENCES↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces

Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due interactions with the metal storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+ loss. In this work, we investigate the performance of two unusual polymers, Teflon AF 2400 and parylene-AF4, as barrier coatings under immersion in 400 ppb Ag+. We show that 25 m-thick parylene-AF4 is a promising coating with Ag+ losses similar to PTFE. Key challenges with this material include maintenance of adhesion under long-term immersion and control of deposition during the internal coating of high-aspect ratio tubing. Solutions to these problems may including surface structuring of substrates for mechanical anchoring or an alternative parylene-C chemistry (with more stable adhesion), and dynamic spatio-temporal control of substrate temperature, respectively.

water↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part II

“Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due to interactions with the metal storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+loss.”1In this work, we continue our investigation of vapor-deposited parylene (AF4, and now C) polymers as conformal barrier coatings under long-term (ca. 1-year) immersion in ca. 400 ppb Ag+. The performanceof internal coatings in tubing/two-ferrule fitting systems is characterized. We report successful “aging” and high concentration Ag+pretreatment of parylene coatings for quantitative reduction of Ag+loss rates. In addition, we observe long-term blister-free adhesion of mechanically anchored parylene-AF4 on nano-structured Ti-6Al-4V alloy and chemically bonded parylene-C on 316L stainless steel. Finally, we report preliminary experiments with mechanical and chemical anchoring of laboratory-deposited parylene-C on 316L.

Silver↗

200 MeV silver ion irradiation induced structural modification in YBa{sub 2}Cu{sub 3}O{sub 7-y} thin films at 89 K: An in situ x-ray diffraction study

We report in situ x-ray diffraction (XRD) study of 200 MeV Ag ion irradiation induced structural modification in c-axis oriented YBa{sub 2}Cu{sub 3}O{sub 7-y} (YBCO) thin films at 89 K. The films remained c-axis oriented up to a fluence of 2x10{sup 13} ions cm{sup -2}, where complete amorphization sets in. The amorphous ion tracks, the strained region around these tracks, and irradiation induced point defects are shown to control the evolution of the structure with ion fluence. Secondary electrons emanating from the ion paths are shown to create point defects in a cylindrical region of 97 nm radius, which corresponds to their maximum range in the YBCO medium. The point defects are created exclusively in the CuO basal planes of fully oxygenated YBCO, which has not been possible, by other techniques including low energy ion irradiation and thermal quenching. The point defects led to a faster decrease in the integral intensity of XRD peaks at very low fluences of irradiation (PHI<=3x10{sup 10} ions cm{sup -2}) than what can be expected from amorphous tracks. The radius of amorphous ion tracks, estimated from the fluence dependence of integral XRD peak intensity beyond this fluence, was found to be 1.9 nm. Both point defect and the strained region around amorphous ion tracks are shown to contribute to the increase in the c-parameter at 89 K. The full width at half maximum (FWHM) of XRD peaks arising mostly due to the strained region around the ion tracks showed an incubation effect up to 10{sup 12} ions cm{sup -2}, before increasing at higher fluences. Fluence dependence of FWHM gives the cross section of the strained region as 37.9 nm{sup 2}, which is more than three times the cross section of the amorphous ion tracks.

36 MATERIALS SCIENCE↗

Humidity Effect on Nanoscale Electrochemistry in Solid Silver Ion Conductors and the Dual Nature of Its Locality

Scanning probe microscopy (SPM) is a powerful tool to investigate electrochemistry in nanoscale volumes. While most SPM-based studies have focused on reactions at the tip-surface junction, charge and mass conservation requires coupled and intrinsically non-local cathodic and anodic processes that can be significantly affected by ambient humidity. Here, we explore the role of water in both cathodic and anodic processes, associated charge transport, and topographic volume changes depending on the polarity of tip bias. The first-order reversal curve current-voltage technique combined with simultaneous detection of the sample topography, referred to as FORC-IVz, was applied to a silver solid ion conductor. We found that the protons generated from water affect silver ionic conduction, silver particle formation and dissolution, and mechanical integrity of the material. This work highlights the dual nature (simultaneously local and non-local) of electrochemical SPM studies, which should be considered for comprehensive understanding of nanoscale electrochemistry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Enhancement in electron field emission in ultrananocrystalline and microcrystalline diamond films upon 100 MeV silver ion irradiation

Enhanced electron field emission (EFE) behavior was observed in ultrananocrystalline diamond (UNCD) and microcrystalline diamond (MCD) films upon irradiation with 100 MeV Ag{sup 9+}-ions in a fluence of 5x10{sup 11} ions/cm{sup 2}. Transmission electron microscopy indicated that while the overall crystallinity of these films remained essentially unaffected, the local microstructure of the materials was tremendously altered due to heavy ion irradiation, which implied that the melting and recrystallization process have occurred along the trajectory of the heavy ions. Such a process induced the formation of interconnected nanocluster networks, facilitating the electron conduction and enhancing the EFE properties for the materials. The enhancement in the EFE is more prominent for MCD films than that for UNCD films, reaching a low turn-on field of E{sub 0}=3.2 V/mum and large EFE current density of J{sub e}=3.04 mA/cm{sup 2} for 5x10{sup 11} ions/cm{sup 2} heavy ion irradiated samples.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Preliminary Testing of Electrolytic Silver Ion Generation for Spacecraft Potable Water Systems

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of imparting biocidal silver into potable water on exploration spacecraft. This method of water disinfection is used commercially in hospitals and marine vessels, but the spacecraft application poses unique challenges such as low water conductivity, increased importance of electrode longevity, and an interface with other systems that may be sensitive to any particles released in the electrolysis process. Testing has shown that due to the low conductivity of the water, the electroactive area of the cell can be scaled linearly to achieve a target electrolysis current despite the general non-linearity of electrochemical systems. More importantly, however, the low conductivity dictates that a large electroactive area and minimal electrode gap be employed in the design. Furthermore, thermodynamic considerations suggest that a low applied voltage is necessary to avoid undesired electrode reactions that could negatively impact long-term performance. Preliminary testing of long-term electrode health suggests that anodic oxide formation may not present as significant a challenge as anticipated; however, further testing in a system closed to the atmosphere is required to rule out the influence of atmospheric CO2 on the pH of the process water. Comparison of filtered and unfiltered silver concentration measurements indicates that release of particles larger than 0.2 μm was negligible in this preliminary test. A test article has been developed to facilitate further testing of silver electrolysis, which continues to be a candidate technology for spacecraft potable water disinfection.

silver↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part IV

Ionic silver (Ag+) biocide is a leading candidate to provide residual microbial control in spacecraft potable water systems, but suffers from rapid concentration loss due to interactions with the metallic storage containers and tubing. One approach to resolve this problem is the coating of metal surfaces with an inert barrier film. In previous reports, we have described our investigations addressing Ag+ loss mitigation and adhesion performance of parylene barrier coatings on coupons of several metal alloys and 316Ltubing under static immersion. In such conditions, parylene-C and -AF4 coatings have shown excellent Ag+loss mitigation and mixed long-term adhesion performance, depending on parylene species and substrate surface chemistry/structure. In Part IV of this series, we report on our work to investigate the performance of parylene-C barrier coatings, under more challenging and realistic conditions, in order to evaluate potential suitability for use. The resilience and associated Ag+ loss with Parylene-C coating on½” (12.7 mm)316L tubing and fittings under medium-term immersion and repeated fitting dis/reassembly were investigated. Potential mechanical challenges to barrier coatings in spacecraft potable water systems were investigated, with two main focuses being identified: liquid flow/pressure cycling in tubing and cyclic operation of bellows in positive-expulsion storage tanks. Two corresponding testbeds for experimental characterization of coating performance were developed. In the Flow/Pressure Testbed System, Ag+ solution will be pumped through internally coated 316L tubing, with optional pressure cycling. In the Bellows Tank Testbed System, an internally coated edge-welded 316L bellows containing Ag+ solution will be cyclically extended and compressed, analogous to the operation of bellows tanks used for potable water storage and delivery on the International Space Station. The design and operation of these testbeds are described. Finally, the Ag+ adsorption and saturation behaviors of Kalrez and Viton, for potential use as seal materials in fittings and other connections, were characterized in limited experiments.

mitigation↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part IV

“Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due to interactions with the metallic storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+ loss.” In previous reports, we have described our investigations addressing Ag+ loss mitigation and adhesion performance of parylene barrier coatings on coupons of several metal alloys and 316L tubing under static immersion. In such conditions, parylene-C and AF4 coatings have shown excellent Ag+ loss mitigation performance, and mixed long-term adhesion performance, depending on parylene species and substrate surface chemistry/structure. In Part IV of this series, we begin to address the performance of parylene-C barrier coatings under more challenging and realistic conditions, in order to evaluate potential suitability in flight systems. Using two testbeds, we characterized coating performance under dynamic mechanical operation. In the Flow/Pressure Testbed System, Ag+ solution is pumped through internally coated 316L tubing, with optional pressure cycling. In the Bellows Tank Testbed System, an internally coated edge-welded 316L bellows containing Ag+ solution is cyclically extended and compressed, analogous to the operation of bellows tanks used for potable water storage and delivery on the International Space Station. Periodic determinations of Ag+ loss with testbed cycling/time and visual observation of the parylene-C coatings were conducted. In addition, we characterized parylene-C coating resilience and Ag+ loss with 316L tubing and multiple fitting types under long-term immersion and repeated fitting dis/reassembly.

Lance Dean Delzeit↗

Preliminary flight prototype silver ion monitoring system, addendum

A number of electrode fabrication techniques are investigated, to achieve an electrode meeting shuttle mission requirements for functional life and stability as well as accuracy and precision of measurement. The instability of a silver bromide column when employed in a closed loop calibration scheme is discussed.

Wilson, R. I.↗

The Effect of Silver Ion Occupancy on Hollandite Lattice Structure

The effect of tunnel cations on tunnel size in α-MnO 2 structured (hollandite, cryptomelane) materials has long been of interest, as the tunnel size effects catalytic and transport properties. Previous research on the tunnel size has focused on potassium cryptomelane (K x Mn 8 O 16 ). This paper uses synthetic control of silver content in Ag x Mn 8 O 16 to investigate the effect that tunnel silver occupancy has on the lattice parameters. Materials with silver (x) content between 1.14 and 1.66 were synthesized, synchrotron diffraction and Rietveld Refinement was used to determine lattice parameters. The lattice parameters were found to contract as silver content increases (from 9.774 Å to 9.738 Å), in contrast to previous investigations of other tunnel cations.

36 MATERIALS SCIENCE↗

Effect of exposure environment on surface decomposition of SiC-silver ion implantation diffusion couples

SiC is a promising material for nuclear applications and is a critical component in the construction of tristructural isotropic (TRISO) fuel. A primary issue with TRISO fuel operation is the observed release of 110m Ag from intact fuel particles. The release of Ag has prompted research efforts to directly measure the transport mechanism of Ag in bulk SiC. Recent research efforts have focused primarily on Ag ion implantation designs. The effect of the thermal exposure system on the ion implantation surface has been investigated. Results indicate the utilization of a mated sample geometry and the establishment of a static thermal exposure environment is critical to maintaining an intact surface for diffusion analysis. In conclusion, the nature of the implantation surface and its potential role in Ag diffusion analysis are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis of Thick Hg x Cd 1– x Se Nanoplatelets by Cation Exchange Catalyzed by Silver Ions, Showing Amplified Spontaneous Emission

II-VI semiconductor nanoplatelets have emerged as promising candidates for various applications, owing to their tunable optical properties dictated by their thickness and compositions. In the realm of infrared technology, mercury chalcogenides stand out as particularly promising materials for optoelectronic applications. However, the direct synthesis of 2D particles in this category remains challenging, thus prompting the exploration of alternative methods such as cation exchange. Here, we demonstrate that the cation exchange process from cadmium to mercury can be effectively catalyzed by monovalent Ag + cations. Further, this catalysis facilitates the formation of alloyed Hg x Cd 1-x Se nanoplatelets with tunable optical properties, with the photoluminescence peak ranging from 1.23 eV for the thinnest three-monolayer (ML) nanoplatelets to 0.92 eV for the thickest 7 ML nanoplatelets. The Ag + ions reduce the activation energy of the cation exchange process by a factor of 2, enabling enhanced penetration of mercury atoms deep into the native CdSe nanoplatelets. Moreover, these nanoplatelets exhibit optical gain in the infrared spectrum, including the 1.3 μm telecommunication band, with a fluence threshold at 80 K of 50 μJ∙cm -2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Electron Mobility and Disorder Induced by Silver Ion Migration Lead to Good Thermoelectric Performance in the Argyrodite Ag 8 SiSe 6

Superionic chalcopyrites have recently attracted interest in their use as potential thermoelectric materials because of extraordinary low thermal conductivities. To overcome long-term stability issues in thermoelectric generators using superionic materials at evaluated temperatures, materials need to be found that show good thermoelectric performance at moderate temperatures. Here, we present the structural and thermoelectric properties of the argyrodite Ag 8 SiSe 6 , which exhibits promising thermoelectric performance close to room temperature.

36 MATERIALS SCIENCE↗