Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

Experimental Study of Acceptor Removal in UFSD

The performance of the Ultra-Fast Silicon Detectors (UFSD) after irradiation with neutrons and protons is compromised by the removal of acceptors in the thin layer below the junction responsible for the gain. In this study, the effect is tested both with capacitance–voltage, C–V, measurements of the doping concentration and with measurements of charge collection, CC, using charged particles. We find a perfect linear correlation between the bias voltage to deplete the gain layer determined with C–V and the bias voltage to collect a defined charge, measured with charge collection. An example for the usefulness of this correlation is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instrumentation and Techniques in High Energy Physics

This book provides an introduction of some of the technology and techniques of modern particle physics. Each chapter is a deep dive into the relevant subject, which includes silicon pixel detectors, plastic scintillator in a high radiation environment, Cerenkov detectors, particle jet identification, noble gas neutrino detectors, and machine learning. The target audience is graduate students and more senior researchers who wish to learn a new technology or technique. The text pedagogical in nature and each chapter is a standalone treatment of a specific topic. The coverage focuses on state-of-the-art techniques, rather than describing the technology's history. Written by acknowledged experts in the subject matter, Instrumentation and Techniques in High Energy Physics, is an important addition to the library of any particle physicist.

Lincoln, Don↗

Characterization of the Cherenkov Photon Background for Low-noise Silicon Detectors in Space

Future space observatories that seek to perform imaging and spectroscopy of faint astronomical sources will require ultra-low-noise detectors that are sensitive over a broad wavelength range. Silicon charge-coupled devices (CCDs), such as EMCCDs, skipper CCDs, multi-amplifier sensing CCDs, and single-electron sensitive read out CCDs have demonstrated the ability to detect and measure single photons from X-ray energies to near the silicon band gap (∼1.1 μm), making them candidate technologies for this application. Here, in this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic cosmic rays traversing a silicon detector. We present a model for Cherenkov photon production and absorption that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low-noise silicon detectors in space. We study how the Cherenkov background rate depends on detector thickness, variations in solar activity, and the contribution of heavy cosmic ray species (Z > 2). We find that for thick silicon detectors, such as those required to achieve high quantum efficiency at long wavelengths, the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds. We apply our Cherenkov background model to simulated spectroscopic observations of extra-solar planets, and we find that thick detectors continue to outperform their thinner counterparts at longer wavelengths despite a larger Cherenkov background rate. Furthermore, we find that minimal masking of cosmic-ray tracks continues to maximize the signal-to-noise ratio of very faint sources despite the existence of extended halos of Cherenkov photons.

Astronomical detectors↗

Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R&D program, aiming at using 3D pixel silicon sensors in the innermost barrel layer of the detector, has been carried out by CMS in collaboration with the FBK (Trento, Italy) and CNM (Barcelona, Spain) foundries. The sensors will feature a pixel cell size of 25 × 100 µm 2 , with a centrally located electrode connected to the readout chip. The sensors are read out by the RD53A and CROCv1 chips, developed in 65 nm CMOS technology by the RD53 Collaboration, a joint effort between the ATLAS and CMS groups. This paper reports the results achieved in beam test experiments before and after irradiation, up to a fluence of approximately 2 . 6 × 1 0 16 n eq /cm 2 . Measurements of assemblies irradiated to a fluence of 1 × 10 16 n˙eq/cm 2 show a hit detection efficiency higher than 96% at normal incidence, with fewer than 2% of channels masked, across a bias voltage range greater than 50 V . Even after irradiation to a higher fluence of 1.6 × 10 16 n˙eq/cm 2 , similar performance is maintained over a bias voltage range of 30 V , remaining well within CMS requirements.

3D pixel↗

Design optimization of MAPS-based detectors using a data-driven fast simulation approach

A parametric simulation tool for pixel sensors is presented. A realistic pixel response is simulated purely based on measurement input, without requiring detailed knowledge of the underlying manufacturing process. As such, it provides an efficient alternative to the use of Technology Computer-Aided Design simulations, which typically depend on proprietary process information. Due to its parametric approach, the package is fast and thus particularly useful for larger detector systems and high hit rate environments. This work presents measurements, simulation and its validation for the MALTA2 sensor. It is a small collection electrode monolithic active pixel sensor produced in the Tower 180 nm complementary metal-oxide-semiconductor imaging process. Modifications to the sensor’s periphery, mainly in the hit merger, are studied in order to optimize the performance for tracking and calorimetry. This optimization is of special interest as part of the MALTA3 sensor redesign in the 65 nm Tower Partners Semiconductor Co. process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light-tight Skipper-CCDs for X-Ray Detection in Space

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising technology for space-based X-ray astronomy. In this scenario, optical and near-infrared photons may saturate the sensor, distorting the reconstructed signal. We present a light-tight shield for skipper-CCDs to suppress optical backgrounds while preserving X-ray detection efficiency. We deposited thin aluminum layers on the CCD surface using an e-beam evaporator and evaluated their blinding performance across wavelengths from 650 to 1000 nm using a monochromator, as well as the X-ray transmission using an 55 Fe source. We find that 50 and 100 nm layers provide >99.6% light suppression, with no efficiency loss for 5.9 and 6.4 keV X-rays. In addition, we used Geant4 simulations to extend these results to a broader energy range and quantify the efficiency loss for different aluminum thicknesses. Results show that thin aluminum coatings are an effective, low-cost solution for optical suppression in skipper-CCDs intended for X-ray detection and space instrumentation.

79 ASTRONOMY AND ASTROPHYSICS↗

ATLAS ITk strip sensor quality control procedures and testing site qualification

Abstract The high-luminosity upgrade of the Large Hadron Collider, scheduled to become operational in 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker. Radiation hard n + -in-p micro-strip silicon sensors were developed by the ATLAS Inner Tracker strip collaboration and are produced by Hamamatsu Photonics K.K. Production of the total amount of 22000 strip sensors has started in 2020 and will continue until 2025. The ATLAS strip sensor collaboration has the responsibility to monitor the quality of the fabricated devices by performing detailed measurements of individual sensor characteristics and by comparing the obtained results with the tests done by the manufacturer. Dedicated Quality Control procedures were developed to check whether the delivered large-format sensors adhere to the ATLAS specifications. The institutes performing the Quality Control testing of the pre-production and production ATLAS ITk strip sensors had to initially be qualified for multiple high-throughput tests by successfully completing the Site Qualification process. The Quality Control procedures and the qualification process are described in this paper.

Instruments & Instrumentation↗

First measurements of energetic protons in Mega Amp Spherical Tokamak Upgrade (MAST-U)

First proton production rates from the d(d,p)t reaction in the Mega Amp Spherical Tokamak Upgrade (MAST-U) are measured. The data were taken during the MAST-U experimental campaign with an upgraded version of the proton detector (PD) previously used in MAST. The new detector array consists of three collimated silicon surface barrier detectors with a depletion depth of 300 μm and a collimated 120 μm thick diamond detector, mounted on the MAST-U reciprocating probe arm. This array measures the energies of unconfined energetic 3 MeV protons and 1 MeV tritons mainly produced by beam-thermal DD reactions during neutral beam injection heating. Diamond detectors have the potential to be uniquely suited to detect charged fusion products as they promise to be much more radiation resistant and much less sensitive to temperature variations compared to silicon-based detectors. Using silicon and diamond-based detectors simultaneously allowed us to directly compare the performance of these two detector types. PD particle rates measured during different plasma scenarios are presented and compared to neutron rates measured using the neutron camera upgrade and TRANSP predictions.

Instruments & Instrumentation↗

Using Quantum Sensors to Probe the Quasiparticle Excess in Quantum Circuits due to Ionizing Radiation

This project quantified natural ionizing radiation as a source of excess quasiparticles in superconducting quantum circuits. Thermal Kinetic Inductance Detectors (TKIDs) were developed and deployed to measure event‑by‑event energy deposition in silicon substrates at millikelvin temperatures. Measurements and radiation transport simulations showed strong agreement across keV–MeV energies, providing validated background models and design guidance to mitigate radiation‑induced decoherence in superconducting qubits and detectors.

97 MATHEMATICS AND COMPUTING↗

Advanced silicon tracking detector developments for the future Electron-Ion Collider

The proposed Electron-Ion Collider (EIC) will operate high-luminosity high-energy electron+proton and electron+nucleus collisions at the collision energies from 20 GeV to 141 GeV to solve several fundamental questions in the high energy and nuclear physics fields. Its instantaneous luminosity can reach 10 33-34 cm -2 s -1 and the bunching crossing rate is around 10 ns. The EIC project has received CD1 approval from the US DOE in 2021 and moves toward the machine design and preparation for construction. To realize various particle measurements with high precision at the future EIC, a low material-budget and high-granularity silicon vertex and tracking detector with fine spatial and momentum resolutions and nearly 4π solid angle coverage is desired. The Monolithic Active Pixel Sensor (MAPS) and AC Coupled Low Gain Avalanche Diode (AC-LGAD) technologies stand out of several advanced technology options for the EIC silicon vertex and tracking detector subsystems. The MAPS technology has advanced features of low material budget, low power consumption, good radiation resistance and fine spatial resolution. The AC-LGAD technology can achieve fast timing resolution. Latest studies and progress of the EIC silicon vertex and tracking detector conceptual design, performance validations in simulation and ongoing MAPS and AC-LGAD R&D will be shown. Furthermore, schedule and plan of the EIC project detector development will be discussed as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Ultra-Fast 4H-SiC LGAD With Etched Termination and Field Plate

The design, fabrication, and demonstration of a novel Silicon Carbide Low Gain Avalanche Detector (4HSiC LGAD), exhibiting an ultra-fast time response and excellent time resolution, are reported. Here, the use of field plates is proposed to suppress the high electric field caused by the negative bevel-etched angle in 4H-SiC LGADs based on TCAD simulations. Experimental measurements confirm that the field plate significantly increases the breakdown voltage of the 4H-SiC LGADs. Gain and time resolution are measured by using the ultraviolet transient current technique (UV-TCT) showing that 4H-SiC LGADs possess excellent timing performance, with a time resolution better than 35 ps for the injected laser signal with single minimum ionizing particle (MIP) charges generation at room temperature. Additionally, the gain suppression effect in a 4H-SiC LGAD is observed for the first time.

43 PARTICLE ACCELERATORS↗

A Comparative Study of Straight-Strip and Zigzag-Interleaved Anode Patterns for MPGD Readouts

Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring strips. However, to effectively extract the inherent positional information, the lateral spacing of the straight strips must be comparable to or preferably smaller than the full extent of the incident charge cloud. In contrast, highly interleaved anode patterns, such as zigzags, can adequately sample the incident charge with a pitch appreciably larger than the charge cloud.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents

Non-ionizing energy loss causes bulk damage to the silicon sensors of the ATLAS pixel and strip detectors. This damage has important implications for data-taking operations, charged-particle track reconstruction, detector simulations, and physics analysis. This paper presents simulations and measurements of the leakage current in the ATLAS pixel detector and semiconductor tracker as a function of location in the detector and time, using data collected in Run 1 (2010-2012) and Run 2 (2015-2018) of the Large Hadron Collider. The extracted fluence shows a much stronger |z|-dependence in the innermost layers than is seen in simulation. Furthermore, the overall fluence on the second innermost layer is significantly higher than in simulation, with better agreement in layers at higher radii. These measurements are important for validating the simulation models and can be used in part to justify safety factors for future detector designs and interventions.

47 OTHER INSTRUMENTATION↗

Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

Here, our Compton profile measurements of Ti and TiH 2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH 2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.