Heavy-particle studies with silicon detectors
Response of lithium-drifted silicon detectors for radiobiologic applications
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Response of lithium-drifted silicon detectors for radiobiologic applications
Data illustrating the radiation response of emerging high gain, low noise detectors are presented. Ionizing dose testing of silicon internal discrete avalanche photodiodes, and 51-MeV proton testing of InGaAs/InAlAs avalanche photodiodes operated in Geiger mode are discussed.
Well shielded ceramic capillary spark source, thermocouple radiation detector and silicon p-n junction diode testing
Thick lithium drifted semiconductor silicon detectors for investigation of fluctuations of energy loss by high and intermediate energy particles
Superconducting magnet spectrometer using lithium drifted silicon detectors for measurement of electron spectra
Silicon surface barrier detector beta gauge for density measurements in liquid hydrogen
Response of lithium-drifted silicon detectors to high energy alpha and proton beam and radiobiologic application
Reports on radiobiology studies, pion studies with silicon detectors, immunology, ultracentrifuge rotor temperature and speed measurement by radio telemetry, and radiosensitivity investigations
Fabrication methods for lithium drifted surface barrier silicon detectors, discussing lithium diffusion, stain etching, preparation for and final etch
Most probable energy loss in silicon for pions with energies from 365 to 50 mev, examining pion beam behavior through different absorption material thicknesses
Silicon surface damage, discussing low energy gamma irradiation effect on bulk lifetime and recombination velocity
Activities directed toward the development of methods of measurement for semiconductor materials, process control, and devices are described. Accomplishments include the determination of the reasons for differences in measurements of transistor delay time, identification of an energy level model for gold-doped silicon, and the finding of evidence that it does not appear to be necessary for an ultrasonic bonding tool to grip the wire and move it across the substrate metallization to make the bond. Work is continuing on measurement of resistivity of semiconductor crystals; study of gold-doped silicon; development of the infrared response technique; evaluation of wire bonds and die attachment; measurement of thermal properties of semiconductor devices, delay time, and related carrier transport properties in junction devices, and noise properties of microwave diodes; and characterization of silicon nuclear radiation detectors.
Multichannel system employing a radioisotope radiation source, strontium-90, radiation detector, and a silicon surface barrier detector, measures the local density of liquid hydrogen at various levels in a storage tank. The instrument contains electronic equipment for collecting the density information, and a data handling system for processing this information.
A filter for electromagnetic radiation including one or more dielectric spacer regions and one or more reflective regions integrated on a semiconductor substrate, the semiconductor substrate including a semiconductor photodetector, such that the filter transmits ultraviolet radiation to the semiconductor photodetector, the ultraviolet radiation having a range of wavelengths, and the filter suppresses transmission of electromagnetic radiation, having wavelengths outside the range of wavelengths, to the semiconductor photodetector.
Totally depleted silicon diodes are discussed which are used as nuclear particle detectors in investigations of galactic and solar cosmic radiation and trapped radiation. A study of radiation and chemical effects on the diodes was conducted. Work on electron and proton irradiation of surface barrier detectors with thicknesses up to 1 mm was completed, and work on lithium-drifted silicon devices with thicknesses of several millimeters was begun.
Alpha particles radiation damage effects in silicon surface barrier detector
Space radiation dosimetry measurements have been made on board the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD)" utilizing silicon semi-conductor detectors and others are conventional detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. Using the RRMD detector, the first attempt of real-time monitoring of space radiation has been achieved successfully for a continuous period of 251.3 h, giving the temporal variations of LET distribution, particle count rates, and rates of absorbed dose and dose equivalent. The RRMD results indicate that a clear enhancement of the number of trapped particles is seen at the South Atlantic Anomaly (SAA) without clear enhancement of dose equivalent, while some daily periodic enhancements of dose equivalent due to high LET particles are seen at the lower geomagnetic cutoff regions for galactic cosmic ray particles (GCRs). Therefore, the main contribution to dose equivalent is seen to be due to GCRs in this low altitude mission (300 km). Also, the dose equivalent rates obtained by TLDs and CR-39 ranged from 146.9 to 165.2 microSv/day and the average quality factors from 1.45 to 1.57 depending on the locations and directions of detectors inside the Space-lab at this highly protected orbit for space radiation with a small inclination (28.5 degrees) and a low altitude (300 km). The LET distributions obtained by two different detectors, RRMD and CR-39, are in good agreement in the region of 15-200 keV/mm and difference of these distributions in the regions of LET < 15 keV/mm and LET > 200 keV/mm can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks.