Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL STABILIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Large-signal Stability Analysis of Grid-forming Inverters with Equivalent-circuit Models

Here, this paper proposes an energy function-based direct method for large-signal stability assessment of grid-forming (GFM) inverters leveraging an equivalent-circuit representation of all involved control- and physical-layer dynamics. Three different primary controls, a standard inner-current outer-voltage cascaded-control architecture, output LCL filter, and reference-current saturation limiting are featured in the modeling and analysis framework. A composite energy function for the GFM inverter is obtained by summing up individual energy contributions gleaned from the circuit representation. The approach can readily be generalized to different primary controls, output-filter arrangements, and current limiters since it is based on a circuit-theoretic foundation. Numerical simulations validate the efficacy of the approach in estimating the critical clearing time following a large-signal disturbance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Small-Signal Stability Analysis of Grid-Forming and Grid-Following Inverters in Low-Inertia Power Systems: Preprint

Inverter-based resources (IBRs) are gradually replacing conventional fossil energy in modern power systems, which could make the system susceptible due to insufficient inertia, especially when moving towards a 100% inverter-based power grid. Grid-forming (GFM) and grid-following (GFL) controls are two common inverter control algorithms. However, the corresponding stability issues along with a comparative study on low-inertia power systems should still be investigated. This paper focuses on small-signal stability and conducts a comprehensive analysis of GFM and GFL controls, with emphases on the interactions between synchronous generators and IBRs. The detailed modeling of GFM and GFL inverters, and synchronous generators (SGs) are established. The coupling mechanism of IBRs and SGs is then conducted through participation factor analysis. The impacts of critical parameters on system stability are finally identified. The theoretical analyses are validated through time-domain simulation in MATLAB/Simulink.

grid-following↗

A Comparative Study of Two Widely Used Grid-Forming Droop Controls on Microgrid Small Signal Stability

Throughout history, two similar grid-forming droop controls are widely reported in literature—the single-and multi-loop droop controls. Although being very similar, the authors find that the dynamic performance and stability characteristics of each control method are very different in a microgrid. Compared with single-loop droop control, the multi-loop droop control is prone to be less damped and loses stability more easily under some circumstances. This paper provides a novel insight into the different dynamic responses of the two basic controls. It points out that the two similar controls adjust the angular frequency and voltage magnitude at different locations within the inverter, resulting in different coupling reactances that impact the dynamic response and stability of microgrids differently. The use of single-loop droop control results in a larger coupling reactance, which helps to improve dynamic response and stability. This novel insight is verified through full-order small signal analysis, offline electromagnetic transient simulation, and real-time hardware-in-the-loop simulation experiments. Results show that the microgrid has a larger small signal stability boundary when using single-loop droop control, and this difference increases as the value of an inverter’s inner filter inductance increases.

42 ENGINEERING↗

Partitioning of Large-Scale Power Electronics-Based Power Systems for Small-Signal Stability Analysis

The nodal admittance matrix (NAM)-based approach is suitable for analyzing the small-signal stability of large-scale power electronics-based power systems (PEPSs) as it preserves the system structure by utilizing the admittance matrix. Previously, NAM-based area partition has been proposed, which divides the system into various subareas and interconnections for easier analysis of the low-dimension matrix compared to the entire system-based high-dimension matrix. However, no partition algorithm has been presented for the NAM-based area partition method. This paper focuses on implementing the spectral partitioning algorithm for partitioning large-scale PEPSs into a low-dimension matrix to reduce the computation complexity of the analysis. These spectral components facilitate data transformation into a new space, enabling the application of traditional clustering methods like k-means. To evaluate the performance of the partitioning method, the subareas and interconnections obtained from the spectral clustering algorithm are incorporated into the NAM-based area partition method for a large system with 140 buses. The computational times of the original method, where the NAM-based criterion is directly applied to the entire system, are compared with those of the NAM-based partition method in MATLAB. PSCAD simulations of the whole system and the obtained subareas are conducted to validate the effectiveness of the proposed algorithm.

Nupur, Nupur↗

Spectral Clustering-Based Partitioning of Large-Scale Power Electronics-Based Power Systems for Small-Signal Stability Analysis

The nodal admittance matrix (NAM)-based approach is well-suited for small-signal stability analysis of large-scale power electronics-based power systems (PEPSs), as it preserves the system structure through its admittance matrix. Previous studies have explored partitioning such systems into subareas and interconnections to reduce computational burden; however, they lacked a formal algorithmic procedure for determining feasible partitions. While several grid partitioning methods, such as those based on graph theory or machine learning, exist in the literature, they cannot be directly applied to NAM-based analysis due to differing objectives and constraints. Here, this paper addresses this gap by presenting a systematic, step-by-step procedure for applying a spectral partitioning algorithm that yields a division of the system into subareas suitable for NAM-based analysis. The computational complexity of the proposed method is also derived to demonstrate its efficiency and justify the practicality of the resulting subarea decomposition. The performance of the partitioning method is evaluated by applying the spectral clustering-derived subareas and interconnections to the NAM-based partitioning approach on a 140-bus system. Computational times for the full-system and partitioned NAM analyses are compared using MATLAB. Additionally, PSCAD simulations of the complete system and partitioned subareas are carried out to verify the effectiveness of the proposed method.

Nupur [Univ. of Tennessee, Knoxville, TN (United S↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytical small-signal stability analysis of low-inertia power system frequency response considering secondary frequency regulation

Modern power systems are increasingly vulnerable to frequency instability as inverter-based resources (IBRs) replace synchronous machines and reduce system rotational inertia. Existing small-signal frequency stability assessment methods are either computationally intensive, relying on simulation-driven approaches, or lack analytical stability regions that explicitly account for secondary frequency response (SFR). This paper introduces new analytical frameworks that enable evaluation small-signal frequency stability while explicitly incorporating tunable IBR and SFR parameters. Using Kharitonov’s theorem with an overbounding approach, explicit small-signal stability criteria are derived. In addition, based on Białas’ criterion and Hurwitz matrix, analytical stability regions are established to reveal feasible design spaces for SFR and IBR parameters tuning. Extensive Matlab/Simulink-based simulations validate the accuracy and computational efficiency of the proposed methods, demonstrating that coordinated tuning of SFR and IBR parameters can substantially enhance system resilience. By bridging analytical rigor with practical tunability, this work provides an analytical framework for assessing small-signal frequency stability in low-inertia grids, supporting the real-time, scalable, and resilient operation of sustainable power systems.

14 SOLAR ENERGY↗

Improved signal stability in inductively coupled plasma–atomic emission spectrometry through use of tandem spray chambers and surfactant addition

A search for causes of intermittent mid-term (about two hours) instability in emission signals from an inductively coupled plasma led to adoption of a tandem spray-chamber arrangement and subsequently to use of a surfactant (Triton X-100) to mitigate the remaining and newly found instabilities. Through a series of investigations, abrupt signal excursions in the tandem setup were traced to droplet coagulation and drainage inside the glass tube that connected the two spray chambers. However, the signal shifts were not the result of sample-solution release directly but rather to the influence of the underlying factors on plasma behavior. Experiments tailored to the study included not only examination of temporal signal behavior but also collection of long-term videos and measurement of radiofrequency characteristics of the plasma. The addition of a surfactant, Triton X-100, for signal-stability improvement is applicable not only to systems that employ tandem spray chambers but also to conventional single Scott-type chamber arrangements. Further, use of the surfactant was unsuccessful in overcoming “acid effects”, either of the steady-state or transient nature, and did not alter plasma background or analyte signals significantly.

Inductively coupled plasma–atomic emission spectro↗

Rapid Small-Signal Stability Assessment and Enhancement Following Changes in Topology

The paper proposes a scalable and tractable algorithm for dynamic topology optimization of power systems involving changes in branch on/off status, while respecting small-signal stability (SSS) constraints. A procedure for fast updates of the system matrices (in descriptor form) and without additional full matrix inversions is proposed. To additionally reduce the computation time, only critical eigenvalues (right-most or those in a specified damping ratio and frequency range) are calculated. A quadratic optimization approach is proposed for optimized generation re-dispatch to satisfy SSS constraints. The approach is applied to two (medium- and large-scale) real-world test power systems.

Saric, AT↗

Small-Signal Stability Constrained Optimal Power Flow of Inverter-Dominated Power Systems with Flexible Operation Mode Selection

Given the intermittence and low inertia nature of inverter-based resources (IBRs), modern power systems with high penetration of IBRs challenge the conventional optimal power flow (OPF) analysis and the system may experience unexpected failures if stability constraints are not incorporated. This study proposes a small-signal stability-constrained OPF (SSSC-OPF) with flexible operation mode selection between grid-forming (GFM) and grid-following (GFL) modes for IBRs to address these challenges. The approach aims to maintain system stability with a sufficient stability margin while minimizing operation costs. The effectiveness of the proposed method is validated through extensive case studies on the IEEE 14-bus system. The results demonstrate that the proposed method is able to support system-level power flow analysis, reduce generation costs, and ensure stability under various disturbances.

grid-following↗

Small-Signal Stability Impacts of Load and Network Dynamics on Grid-Forming Inverters

This paper presents several stability analyses for grid-forming inverters and synchronous generators considering the dynamics of transmission lines and different load models. Load models are usually of secondary importance compared to generation source models, but as the results show, they play a crucial role in stability studies with the introduction of inverter-based resources. Given inverter control time scales, the implications of considering or neglecting electromagnetic transients of the network are very relevant in the stability assessments. In this paper, we perform eigenvalue analyses for inverter-based resources and synchronous machines connected to a load and explore the effects of multiples models under different network representations. We explore maximum loadability of inverter-based resources and synchronous machines, while analyzing the effects of load and network dynamic models on small-signal stability. The results show that the network representation plays a fundamental role in the stability of the system of different load models. The resulting stability regions are significantly different depending on the source and load model considered.

grid forming inverters↗

Large-Signal Stability of Phase-Balanced Equilibria in Single-Phase Grid-Forming Inverter Systems

This article explores the setup where large numbers of single-phase grid-forming inverters with droop control across distribution networks self-organize into a stable and balanced system with 120° phase offsets across aggregates in the absence of balanced three-phase generating resources or external communication. A suite of circuit- and system-theoretic notions are leveraged to derive a dynamical model for phase-angle differences across aggregates of inverters connected in the three phases. Focusing on this model, large-signal stability is established and the region of attraction of the phase-balanced equilibria is determined with the aid of a Lyapunov function. Experimental validation for a bench-top prototype network is included to support the analytical developments. Altogether, the effort supports the vision of facilitating balanced operation of distribution networks with grid-forming inverters during service disruptions at the bulk transmission network.

Droop control↗

Large-Signal Stability Improvement of Parallel Grid-Forming Inverter-Driven Black Start: Preprint

With the rapid increase of inverter-based resources in modern grids, advanced grid-forming (GFM) inverter capa- bilities, such as system restoration and operation under faults, are urgently needed to realize power electronics-dominant grids at scale. One such capability is inverter-driven black start using GFM inverters. This paper analyzes the ability of two recently proposed advanced GFM controls to help GFM inverters sustain system-wide, off-nominal conditions and remain synchronized until they can overcome the momentary overloading as more GFMs join the process without generator sequence coordination or communications and finally stabilize the grid. Through an extensive set of 1,200 full-order electromagnetic transient simu- lations, we evaluate the black-start process while employing the various GFM inverter controls. The results show that the GFM current limiter and primary control have a significant impact on the stability of the system during dynamic operating conditions and thus impact the success of inverter-driven system restoration.

current limit↗

Small-Signal Stability Analysis of Low-Inertia Power Grids with Inverter-Based Resources and Synchronous Condensers: Preprint

With the potential environmental impacts of conventional fossil fuels and the technology advances of grid interactive power electronics, inverter-based resources (IBRs) are playing a crucial role in modern power grids. However, due to the lack of physical inertia, IBRs are vulnerable to system disturbances. Further, conventional grid-following (GFL) inverters cannot actively establish the frequency and voltage, which could not be a appropriate solution for 100% inverter-based power grids. Grid-forming (GFM) control, as an emerging inverter control function, has drawn great attention in recent years, while it is still under development and pre-mature for large-scale field deployment. A potential solution for gradually transitioning into a 100% inverter-based power grid is to combine both IBRs and synchronous machines into a mixed generation portfolio. More importantly, synchronous machines can be operated as synchronous condensers (SCs) until they are retired. It is also worth mentioning that the stability analysis is of great importance to ensure the smooth transition from existing power grids to 100% inverter-based system, which is the main focus of this work with detailed modeling and modal analysis.

100% renewable↗

Temporal signal stability of KCl:Eu{sup 2+} storage phosphor dosimeters

Purpose: Current KCl:Eu{sup 2+} prototype dosimeters require a wait time of 12 h between irradiation and dosimetric readout. Although irradiating the dosimeters in the evening and reading on the following day works well in the clinical schedule, reducing the wait time to few hours is desirable. The purposes of this work are to determine the origin of the unstable charge-storage centers and to determine if these centers respond to optical or thermal excitation prior to dosimetric readout. Methods: Pellet-style KCl:Eu{sup 2+} dosimeters were fabricated in-house for this study. A 6 MV photon beam was used to irradiate the dosimeters. After x ray irradiation, dosimeters were subjected to external excitation with near-infrared (NIR) light, ultraviolet (UV) light, or thermal treatment. Photostimulated luminescence (PSL) signal's temporal stability was subsequently measured at room temperature over a few hours using a laboratory PSL readout system. The dosimeters were also placed in a cryostat to measure the temperature dependence of the temporal stability down to 10 K. Results: Strong F-band was present in the PSL stimulation spectrum, indicating that F-centers were the electron-storage centers in KCl:Eu{sup 2+} where an electron was stored at a chlorine anion vacancy. Due to deep energy-depth (2.2 eV), F-centers were probably not responsible for the fast fading in the first a few hours post x ray irradiation. In addition, weak NIR bands were present. However, there was no change in PSL stabilization rate with intense NIR excitation, suggesting that the NIR bands played no role in the PSL fading. At temperatures lower than 77 K there was almost no signal fading with time. Noticeable PSL was observed for undoped KCl samples at room temperature, suggesting that Cl{sub 2}{sup -} V{sub k} centers served as hole-storage centers for both undoped and doped KCl where a hole was trapped by a chlorine molecular ion. V{sub k} centers were stable at low temperature and became mobile at room temperature, probably causing the observed PSL fading with time. On the other hand, V{sub k} center could be stabilized by Eu{sup 2+} activator or oxygen in the lattice, leading to the stable component in the PSL. A thermal process at elevated temperatures (60 Degree-Sign C or higher) was able to significantly accelerate the migration process resulting in a fast stabilization of PSL. However, this could not be accomplished using intense UV excitation. Conclusions: Thermal treatment enables KCl:Eu{sup 2+} prototypes to be ready for readout in 1 h without the need of applying a large time-dependent correction factor. However, this cannot be achieved using optical preexcitation.

36 MATERIALS SCIENCE↗